• 제목/요약/키워드: impressions

검색결과 425건 처리시간 0.02초

Alginate와 Agar-Agar에 의한 연합인상법의 촌법정도에 관한 임상적 연구 (A Clinical Study on the Dimensional Accuracy of the Combined Impression (Alginate & Agar-Agar))

  • 하주태;이정만;최부병
    • 대한치과의사협회지
    • /
    • 제17권9호통권124호
    • /
    • pp.701-708
    • /
    • 1979
  • A series of combined impressions, alginate impressions and rubber base impression made of the lower left quadrant of one subject having a cast gold crown with six reference marks on lower let 1st molar. the combined impressions of hydrocolloid were removed from the mouth at 2.5min, after the insertion of the tray. The alginate impressions were removed from the mouth at 2min, after the insertion of the tray. The rubber base impressions were removed from the mouth at 10min. The effect on the accuracy of the combined impressions, alginate impressions and rubber base impressions was obtained following results by comparing the distances between the reference marks in indirect stone cast with the standard measurements of the cast gold crown prior to cementation. The findings through this study could be summarized as follows; 1. The accuracy of combined impression was superior to that of alginate impression, but it was inferior to that of rubber base impressions. 2. Combined impressions produced a little distortion of the mesio-distal length, alginate impressions produced the largest distortion, ut rubber base impressions produced the least distortion.

  • PDF

PSYCHOLOGICAL EVALUATION AND THE APPLICABILITY OF THE IMPRESSION TRANSFER VECTOR METHOD FOR SYNTHESIZING HIGHER-ORDER FACIAL IMPRESSIONS

  • Sakuta, Yuiko;Ishi, Hanae;Akamatsu, Shigeru;Gyoba, Jiro
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.689-694
    • /
    • 2009
  • We developed a facial image generating technique that can manipulate facial impressions. The present study applied this impression transferring method to higher-order impressions such as "elegance" or "attractiveness" and confirmed the psychological validity of this method using the semantic differential method. Subsequently, we applied this method to two types of cognitive experiments. First, we examined the contributions of texture and shape on the facial impressions by using those face images for which the impressions have already been quantitatively manipulated based on this method. Second, we used such stimuli to examine the effect of facial impressions and attractiveness on the "mere exposure effect." Thus, we concluded that the impression transfer vector method is an effective tool to quantitatively manipulate the facial impressions in various cognitive studies.

  • PDF

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

  • Jiang, Tingting;Lee, Sang-Mi;Hou, Yanan;Chang, Xin;Hwang, Hyeon-Shik
    • 대한치과교정학회지
    • /
    • 제46권3호
    • /
    • pp.129-136
    • /
    • 2016
  • Objective: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods: Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results: All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions: The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

얼굴 인상과 물리적 특징의 관계 구조 분석 (The analysis of relationships between facial impressions and physical features)

  • 김효선;한재현
    • 인지과학
    • /
    • 제14권4호
    • /
    • pp.53-63
    • /
    • 2003
  • 얼굴 인상과 얼굴의 물리적 특징 사이의 관계를 분석하고 인상이 얼굴의 유사성 판단에 미치는 영향을 조사하였다. 얼굴 데이터베이스로부터 선정한 79개의 얼굴에 대해 '순하다-사납다', '영리하다-우둔하다', '여성스럽다-남자답다', '앳되다-성숙하다'의 네 개 차원에 대한 인상 평정값과 41개의 물리적 특징의 측정값을 수집하였다. 두 가지 값을 대상으로 한 중다 회귀 분석 결과, 얼굴의 물리적 구조가 인상과 밀접한 관계가 있는 것으로 나타났다. 얼굴의 유사성 판단 실험을 통해서 인상이 얼굴 정보 처리 과정에서의 사용 가능성을 확인하였다. 실험 결과, 사람들은 물리적 특징 조건이 비슷할 때 중성 인상의 얼굴보다 동일한 인상의 얼굴들을 더 유사하게 지각하는 것으로 나타났다. 이러한 결과들은 인상이 얼굴 생김새를 표상하는 심리적인 구조로 사용되며 인상 정보가 얼굴 처리 과정에 포함될 가능성이 있음을 시사한다.

  • PDF

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

과학자에 대한 청소년의 인상 (이미지)

  • 김학수;홍혜현;박성철
    • 기술혁신연구
    • /
    • 제11권2호
    • /
    • pp.41-69
    • /
    • 2003
  • The main purpose of this study is to investigate the Korean youths' impressions of the scientist. The concept of impression is assumed to reflect our significant view of an object better than that of image. That is, the basic assumption is that we tend to behave toward an object, based on its impression which is conceived to be "significant". In late August and early September 2002, a national survey for 1,204 youth (406 for 5th grad; 381 for 8th grade; and 417 for 11th grade) was conducted to find the Korean youths' impressions of the scientist. Our major finding is that the Korean youths' most impressions of the scientist were re his or her activities such as inventing, experimenting, researching, etc. And the major sources of those impressions were found to be television, book, and class. Other findings were about youths' impressions of the science teacher and opinions of the scientist as a profession. Finally, some policy-related implications based on survey results were presented at the end.

  • PDF

Constructing Impressions with Multimedia Ringtones and a Smartphone Usage Tracker

  • Lee, KangWoo;Choo, Hyunseung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권5호
    • /
    • pp.1870-1880
    • /
    • 2015
  • In this paper, we studied facial impression construction with smartphones in a series of experiments with two smartphone applications: SmartRing and SystemSens+. In the first experiment, impressions of faces associated with different music genres (trot vs. classical) were compared to impressions formed from a facial image alone along the social warmth and intelligence dimensions. In the second experiment, the effect of similarity attraction was investigated by manipulating the extroversion of facial images. Results indicated that impressions of faces cannot only be constructed along the social warmth and intelligence dimensions, but can also be made more or less attractive based on their similarity to the viewer's personality. Our experiments provide interesting insights into facial impressions formed in a smartphone environment.

Chemical enhancement of footwear impressions in urine on the surface of tiles

  • Kim, Sung Jin;Hong, Sungwook
    • 분석과학
    • /
    • 제32권3호
    • /
    • pp.113-119
    • /
    • 2019
  • Enhancement of footwear impressions in urine on the surface of tiles by using p-dimethylaminocinnamaldehyde (DMAC), which react with urea, and ninhydrin, 1,8-diazafluoren-9-one (DFO), 1,2-indanedione/zinc (1,2-IND/Zn), which react with amino acid, was studied. As a result of comparing the application methods of reagents, the ninhydrin and the 1,2-IND/Zn were suitable for application with spray method, which is spray directly on footwear impression, DFO and DMAC were suitable for application with dry contact method, which is applying heat with press to DMAC impregnated paper on footwear impression. In addition, DMAC applied with dry contact method showed best contrast and enhancement result in both white and black colored tiles by comparing of the sensitivity by different dilution ratio of urine and the aging time of footwear impressions in urine. And the result of applied with DMAC (with dry contact method) on the floor tiles collected at various places in a building's men's and women's bathrooms, it can be successfully enhanced that footwear impressions in urine. So it is believed that the method can be used to recover footwear impressions in urine from real crime scenes.

A simple and effective method for addition silicone impression disinfection

  • Azevedo, Maria Joao;Correia, Ines;Portela, Ana;Sampaio-Maia, Benedita
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권3호
    • /
    • pp.155-161
    • /
    • 2019
  • PURPOSE. Although dental impression disinfection is determinant to reduce the cross-infection risk, some studies have shown that, in real practice, the disinfection procedures vary considerably. Thus, the aim of this study was to evaluate the antimicrobial effectiveness and the impact on the dimensional stability of addition silicone' impressions of water wash and the most clinically used disinfection solutions: 3% hydrogen peroxide, commercial disinfectant MD520 (Durr) and 1% and 5.25% sodium hypochlorite. MATERIALS AND METHODS. For this investigation, dental impressions were taken on 16 volunteer dental students. The antimicrobial effectiveness of each procedure was evaluated by pour plate method. The dimensional stability was evaluated using a standardized stainless-steel model, according to ANSI/ADA nº19 specification. RESULTS. The study results showed that water wash does not alter the dimensional stability of addition silicone impressions but doesn't reduce the microbial load of the material (P>.05). On the other hand, addition silicone disinfection by immersion with 3% hydrogen peroxide, MD520 (Durr), or sodium hypochlorite at 1% and 5.25% does not alter the dimensional stability significantly but reduces > 99.9% of the microbial load of the impressions (P<.001). CONCLUSION. Addition silicone impressions should always be disinfected after water wash in order to reduce effectively the cross-infection risk. All disinfectants tested showed high antimicrobial efficiency without significant changes in three-dimensional shape of impressions. Hydrogen peroxide and sodium hypochlorite are of particular importance because are easily accessible in dental setting. The less explored hydrogen peroxide could be a valuable alternative for silicone impressions disinfection.

디지털 인상법과 전통적 인상법의 정확도 비교: 체계적 고찰 (Comparison of the accuracy of digital impressions and traditional impressions: Systematic review)

  • 김경록;서권수;김선재
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.258-268
    • /
    • 2018
  • 목적: 본 연구는 보철물의 적합 및 인상의 정확성에 관한 문헌들을 체계적으로 고찰하여 구강 내 스캐너를 이용한 디지털 인상법이 전통적인 인상법을 대체할 만한 정확도를 보이는지 알아보고자 한다. 재료 및 방법: 1997년 8월 1일부터 2017년 7월 31일까지 출판된 영어로 쓰여진 연구를 대상으로 디지털 인상법의 정확성에 대한 문헌을 MEDLINE/PubMed 전자 검색 및 수기탐색을 시행하였다. 조건에 따라 선택된 연구의 데이터를 스프레드 시트에 2명의 검토자가 독립적으로 정리하였다. 결과: 총 35개의 연구가 선택되었고, 26개의 연구는 보철물의 적합성을 비교하였고 9개의 연구는 보철물 없이 스캔 데이터를 통해 인상의 정확성을 비교하였다. 대부분의 연구가 보철물을 이용해 인상법의 정확성을 비교하였다. 결론: 본 고찰에 따르면 자연치열에서 디지털 인상법으로 단일관이나 근원심으로 길이가 짧은 보철물을 제작하는 것은 임상적으로 충분히 신뢰할만한 하다. 그러나 디지털 인상법으로 길이가 긴 보철물을 제작하는 것은 연구가 적어 아직 한계가 있다. 임플란트 보철물 제작에 있어서 구내스캐너를 이용한 디지털 인상법으로 전통적인 인상법을 완전히 대체하기는 아직 어렵다.