• Title/Summary/Keyword: impression technique

Search Result 178, Processing Time 0.029 seconds

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Restless Legs Syndrome and Quality of Life in Hemodialysis Patients (혈액투석을 받는 만성신부전 환자에서 하지불안증후군과 삶의 질)

  • Choi, Hyun-Seok;Kang, Seung-Gul;Boo, Chang-Su;Lee, Heon-Jeong;Cho, Won-Yong;Kim, Hyoung-Kyu;Kim, Leen
    • Sleep Medicine and Psychophysiology
    • /
    • v.14 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Objective: Restless legs syndrome (RLS) is known to be associated with chronic renal failure (CRF) patients on hemodialysis, however the prevalence of RLS in CRF patients on hemodialysis is variable due to different diagnostic criteria or dialysis technique. A few reports have indicated the association between RLS symptom and lower life quality in CRF patients on hemodialysis. This study aims to investigate the prevalence of RLS and its association with the quality of life in CRF patients of a single dialysis unit in Korea. Methods: A total of 83 Korean CRF patients on hemodialysis in the Korea University Hospital were examined. International Restless Legs Syndrome Study Group (IRLSSG) criteria and International Restless Legs Scale (IRLS) were used to determine the diagnosis and severity of RLS. Questionnaires including Athens Insomnia Scale (AIS), Epworth sleepiness scale (ESS), and Medical Outcome Study Form-36 (SF-36) were administered to all the patients for the assessment of sleep and quality of life. Hamilton Depression Rating Scale (HDRS) and Clinical Global Impression (CGI) were also measured for depression and status of mental illness by psychiatrist. Results: Of the 83 patients, 31 (37.3%) patients were found to have RLS and 43 (51.8%) patients met at least one of the RLS diagnostic criteria. The AIS (t=2.40, p=0.019), ESS (t=2.41, p=0.018), HDRS (t=3.85, p<0.001) and CGI (t=3.52, p=0.001) were higher in the subjects with RLS compared to other subjects. The SF-36 scores were significantly lower in the patients with RLS except physical functioning and bodily pain. Total (p=0.005), physical component (p=0.019), and mental component scores (p=0.019) of SF-36 were significantly lower in patients with more severe RLS symptoms. Conclusion: There was significant relationship between RLS and poor quality of sleep and life. More severe RLS symptom was proven to be an important factor to make a quality of life worsen.

  • PDF

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

The efficacy of ultrasonic irrigation technique on debris removal during root canal treatment (근관치료 시 초음파 세정 기술을 이용한 잔사 제거의 효율성)

  • Kim, Jeong-Hyeon;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.97-105
    • /
    • 2017
  • Purpose: The purpose of this study was comparing the efficacy of passive irrigation (PI) and passive ultrasonic irrigation (PUI) for ability to remove debriment of canals. Materials and Methods: Mandibular premolars were decoronated and standardized to 16 mm length. After root canal enlargement and half separating longitudinally, standardized groove of 4 mm length, 0.2 mm width and 0.5 mm depth were formed on the dentin wall of one half. Three depressions in the canal wall of the opposite half, 0.3 mm in diameter and 0.5 mm in depth, were formed. After each groove and depression was filled with dentin debris, two sections of each half were reassembled using impression putty material. In group 1 the canals were irrigated with 2.5% NaOCl by PI. In group 2 the canals were irrigated with 2.5% NaOCl by PUI. Before and after root canal irrigation, the root canal wall of the section was taken with a microscope and a digital camera as images. The amount of dentin debris remaining in grooves and depressions was assessed using a scoring system. Results: There was no significant difference between PI and PUI except for the middle 1/3 of the root canal (P = 0.004). Conclusion: At the middle 1/3 of the root canal, PUI removed more dentine debris than PI. But the removal efficiency of dentin debris is not significantly different between the PUI and PI at the apical area of root canal in mandibular premolars.

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.

Fabrication of suction denture by using the individual tray duplicated an existing denture through scan and milling process: A case report (스캔 및 밀링을 통해 기존 의치를 복제한 개인트레이를 이용한 흡착식 의치 제작 증례)

  • Park, Minhyuk;Kee, Wonjin;Yang, Hongso;Park, Sang-Won;Yun, Kwi-Dug;Park, Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.221-227
    • /
    • 2020
  • In the case of complete edentulous patients, as the mandibular alveolar bone absorption progresses, the maintenance and stability of the existing dentures, which had satisfactory functions in the past, are deteriorated. Despite of the need to fabricate new dentures, they often hesitate due to physical burdens on the duration and intensity of future treatment progress due to the effects of aging and systemic diseases. In the case of these completely edentulous patients, it is necessary to consider the treatment goals that can reduce the number of visits and the adaptation period for new dentures before starting the treatment. This case is a case of producing complete dentures of elderly patients with deteriorated physical ability. In addition to producing suction dentures through preliminary and definitive closed mouth functional impression suggested by Sato, CAD / CAM technique was used to transfer occlusal functional information of existing dentures to facilitate adaptation to new dentures.

A Study on th e Creation of Floral Art Works Applying th e Meth ods of th e Narration and Visualization of the Experiences (경험의 서사화와 시각화 방법을 적용한 화예작품 창작의 연구)

  • Han, Yujeong;Yoo, Taeksang
    • Journal of the Korean Society of Floral Art and Design
    • /
    • no.43
    • /
    • pp.39-56
    • /
    • 2020
  • This study is on the creation of floral art works based on the intuitive insight acquired by methodological process of ruminating the experienced meaningful events of the artists utilizing sensible perception. The researcher used the narration and visualization techniques. The narration process adopted the writing technique of subjective impression, emotion, stream of consciousness to capture sensations of subconscious state, which were applied in three steps of 'the exploration of experiences', 'the concretion of experiences', and 'the creation of meaning out of experiences'. The visualization process adopted collection, selection, classification, and interpretation of related images, which were applied in three methods of 'the creation of images', 'the utilization of intuition', and 'the perception through remembering'. Finally 5 art works of 'Hammock is Good', 'At the Rooftop with Warm Sunshine', 'Standing at the Waterside Alone', 'Dizziness at Hot Sand Field', and 'Having Good Time at a Botanical Garden'were created through the combination of these two methods mentioned above and complementary research and writing. The meaningfulness of this research lies in presenting methodological approaches of utilizing narration and visualization of experiences in art creation process.

Development of Hair Accessory Designs Using Royal Hair Ornaments (왕실 머리장식을 응용한 헤어 액세서리 디자인 개발)

  • Jinyoung Ryu;Jiyeon Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.83-90
    • /
    • 2023
  • The recent trend in younger generations of wearing traditional costumes or incorporating fusion hanbok into daily wear necessitates the development of modern hair accessories to complement hanbok. The purpose of this study is to develop practical and modern hair accessory designs inspired by royal women's hair ornaments that complement hanbok, and therefore expand the scope of fashion content development utilizing hanbok culture as well as meeting the demand for various experiences of traditional culture. This research studied the literature on traditional hairstyles and accessories of Queen Yeong and constructed models of these accessories for the purpose of empirical research. The production process first required creating a basic foundation of nylon mesh reflecting the silhouette of a traditional hairstyle, and then grafting a digital textile printed fabric using majestic and extravagant royal relics on top, thus employing the trompe l'oeil technique to ultimately give the impression of wearing traditional jewelry. As a result, a total of six hair accessory designs were completed, produced with hairbands, hair pins, and hair ties. In addition, the accessories are designed to be easily worn regardless of the wearer's hair style, and the stiff yet flexible nylon mesh effectively expresses the shape of a voluminous hairstyle and creates an optical illusion, blending into the hair. These research results present a unique aesthetic and cultural experience to the greater public seeking both daily entertainment and value from rarity.

Effect of digital competence on scan time and scan error in intraoral scanning (디지털 역량이 구강스캐너의 스캔 시간 및 스캔 오차에 미치는 영향)

  • Yun-Woo Kim;Do-Seon Lim;Hee-Jung Lim;Im-Hee Jung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.271-280
    • /
    • 2024
  • Objectives: This study aimed to test whether the digital competence of dental hygienists can affect their intraoral scanning potential in terms of scan time and error. Methods: Dental hygienists and dental hygiene students who had never used an intraoral scanner were surveyed to determine their digital competence. Individual data collected using an intraoral scanner was compared with reference data collected using a model scanner to identify scanning errors, and participants' scanning times were measured. Results: A significant decrease in scanning time was observed as the overall level of digital competence increased. The increase in digital skills and digital knowledge led to a decrease in scanning time by 3.73 and 3.98 minutes, respectively. Conclusions: This study found that digital competence was associated with reduced scan times, but less so with scan errors. This may be due to recent advances in scanning software, and future studies may need to develop a digital competence assessment tool that is more appropriate for the dental field.