• 제목/요약/키워드: impressed potential

검색결과 40건 처리시간 0.022초

Al-황동의 응력부식균열 특성에 미치는 인가전위의 영향 (Effect of Impressed Potential on the SCC of Al-Brass)

  • 정해규;임우조
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.69-74
    • /
    • 2004
  • In general, the protection method of Shell and Tube Type heat exchanger for a vessel has been applied as a sacrificial anode, which is attached at the inner side of the shell. However, this is an insufficient protection method for tube. Therefore, a more suitable method, such as the impressed current cathodic protection for tube protection, is required. Al-brass is the raw material of tubes for heat exchanger of a vessel where seawater is used for cooling the water. It has a high level of heat conductivity, excellent mechanical properties, and a high level of corrosion resistance, due to a cuprous oxide (Cu$_2$O) layer against th seawater. However, in actuality, it has been reported that Al-brass tubes for heat exchanger of a vessel can produce local corrosion, such as stress corrosion cracking (SCC). This paper studied the effect of impressed potential on the stress corrosion cracking of Al-brass for impressed current cathodic protection in 3.5% NaCl +0.1% NH$_4$OH solution, under flow by a constant displacement tester. Based on the test results, the latent time of SCC, stress corrosion crack propagation, and the dezincification phase of Al-brass are investigated.

가스보일러용 STS 304의 부식특성에 미치는 용수의 비저항의 영향 (Effect of the Specific Resistance of Water on Corrosion Characteristics of STS 304 for Gas Boiler)

  • 임우조;김환식;윤병두
    • 수산해양교육연구
    • /
    • 제19권3호
    • /
    • pp.323-328
    • /
    • 2007
  • This paper was studied on the effect of the specific resistance of water on corrosion characteristics of STS 304 for gas boiler. The electrochemical polarization test of STS 304 for gas boiler was carried out. And the polarization resistance, uniform corrosion, corrosion behavior by impressed potential and corrosion sensitivity of STS 304 with specific resistance were considered. The main results are as following: 1) With being low the specific resistance of water, the polarization resistance and corrosion potential of STS 304 decreases, while corrosion current density increases. 2) Under constant impressed potential, the corrosion sensitivity of STS 304 is large with being low the specific resistance due to synergy effect of Cl ion.

The effect of temperature and relative humidity on concrete slab specimens with impressed current cathodic protection system

  • Jeong, Jin-A;Jin, Chung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권3호
    • /
    • pp.260-265
    • /
    • 2013
  • Impressed current cathodic protection (ICCP) system is one of the most promising corrosion protection methods. The Effect of ICCP system can be changed at diverse conditions. Particularly, temperature and relative humidity plays a crucial role in CP (Cathodic Protection) effect. Thus, in this study, the influence of temperature and relative humidity on concrete specimens was investigated. Specimens were concrete slab type with a base of $400mm{\times}400mm$ and height of 70mm. To enhance the effect of CP system, seawater was used as an electrolyte. Used anode for ICCP system was mixed metal oxide (MMO) titanium. Test factors were natural potential, CP potential, CP current, and 4-hour depolarization potential. From this study, it could be confirm that CP potential and current were highly influenced by temperature and relative humidity.

콘크리트 중의 철근 부식 억제를 위한 외부전원법의 효과 (Effect of Impressed Current System for Corrosion Protection of Rebars in Concrete)

  • 문한영;김성수;김홍삼
    • 콘크리트학회지
    • /
    • 제11권2호
    • /
    • pp.221-230
    • /
    • 1999
  • 콘크리트 구조물에 균열이 생겨 물과 산소의 침투확산이 용이해 지거나 또는 외부로부터 염소이온과 같은 염화물이 침투확산되어 콘크리트 중의 철근까지 도달할 경우 및 콘크리트의 중성화가 철근위치까지 진행될 경우 철근의 부동태 피막은 파괴되어 부식이 급진전 되며 콘크리트의 박리 및 탈락현상이 수반될 뿐만 아니라 구조물의 내구성이 크게 저하된다. 본 연구에서는 콘크리트 중의 철근부식을 억제하기 위한 한 방안으로 적용되는 전기방식의 이론적인 고찰과 콘크리트 내부에 다량의 염화물을 함유시키거나 또는 균열을 발생시킨 시험체에 대하여 외부전원법을 활용한 실내실험을 실시하여 철근의 방식효과에 대해 고찰하였다. 외부전원법에 의한 전기방식을 실시하여 복극량을 측정한 결과 대상 시험체 모두 NACE의 방식기준을 만족하였으며, 부식면적율의 측정결과 34 ~84%, 단면감소의 경우 84 ~ 86%의 방식효과를 확인하였다.

콘크리트 중의 철근부식 방지를 위한 외부전원법의 적용 (The Application of Impressed Current System for the Corrosion Control of Reinforcing Steel in Concrete)

  • 문한영;김성수;김홍삼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.197-202
    • /
    • 1997
  • Recently the interest in the reinforcing steel corrosion due to the use of sea-sand and deicing salt, marine environment, and carbonation in RC structures is increasing, therefore the studies on the corrosion control of reinforcing steel in concrete are vigorously proceeding. In this study, from the viewpoint of electrochemical process of steel corrosion in concrete we applied the impressed current system among the cathodic protections to reinforcing steel in concrete and ascertained the protection effect by half-cell potential, corrosion rate, and depolarization.

  • PDF

역 문제에 의한 파이프의 결함위치 평가 (Estimation of Defect Position on the Pipe Line by Inverse Problem)

  • 박성완
    • 한국생산제조학회지
    • /
    • 제20권2호
    • /
    • pp.139-144
    • /
    • 2011
  • This paper presents a boundary element application to determine the optimal impressed current densities at defect position on the pipe line. In this protection paint, enough current must be impressed to lower the potential distribution on the metal surface to the critical values. The optimal impressed current densities are determined in order to minimize the power supply for protection. This inverse problem was formulated by employing the boundary element method. Since the system of linear equations obtained was ill-conditioned, including singular value decomposition, conjugate gradient method were applied and the accuracies of these estimation. Several numerical examples are presented to demonstrate the practical applicability of the proposed method.

가스 냉온수기용 STS 304 배관 용접부의 부식특성에 관한 연구 (The Study on the Corrosion Characteristics of STS 304 Pipeline Steel Weldment for Gas Cooling & Heating System)

  • 김환식;임우조
    • 한국가스학회지
    • /
    • 제11권2호통권35호
    • /
    • pp.31-36
    • /
    • 2007
  • 가스 냉온수기용 STS 304 배관 용접부의 부식특성을 연구하기 위하여, 0.5M $H_2SO_4+0.01M$ KSCN 수용액 중에서 전기화학적 분극시험, 금속조직시험 과 경도시험을 실시하여 STS 304배관 용접부의 양극분극거동, 인가전위에 따른 부식거동, 용접부의 금속조직 및 경도거동를 고찰하였다. 다음과 같은 결론을 얻었다. 1) 임계양극전류밀도는 모재보다 용접열영향부에서 많이 배류되고, 기본부동태전위는 모재보다 용접열영향부에서 더 높게 된다. 2) 부동태전류밀도는 모재보다 용접열영향부에서 더 많이 배류되고, 부동태영역은 용접열영향부보다 모재가 더 크게 된다. 3)인가전압에 의한 용접열영향부의 전류밀도는 모재의 전류밀도보다 더 많이 배류된다.

  • PDF

A New Protection Strategy of Impressed Current Cathodic Protection for Ship

  • Oh, Jin-Seok;Kim, Jong-Do
    • Journal of Mechanical Science and Technology
    • /
    • 제18권4호
    • /
    • pp.592-596
    • /
    • 2004
  • Corrosion is never avoided in the use of materials with various environments. The underwater hull is normally protected against rusting by several coatings of anti-corrosive paint. The purpose of ICCP(Impressed Current Cathodic protection) system is to eliminate the rusting or corrosion, which occurs on metal immersed in seawater. The anode of ICCP system is controlled by an external DC source with converter. The function of anode is to conduct the protective current into seawater. The proposed algorithm includes the harmonic suppression control strategy and the optimum protection strategy and has tried to test the requirement current density for protection, the influence of voltage, the protection potential. This paper was studied the variation of potential and current density with environment factors, time and velocity, and the experimental results will be explained.

EFFECT OF POST-WELD HEAT TREATMENT OF MARINE STRUCTURE STEEL DURING CATHODIC PROTECTION

  • Kim, Seong-Jong;Masazumi Okido;Kim, Jin-Gyeong;Moon, Kyung-Man
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.273-275
    • /
    • 2002
  • The effect of post-weld heat treatment (PWHT) of marine structures steel was investigated at electrochemical viewpoint. In addition, slow strain rate test (SSRT) was carried out to investigate both electrochemical and mechanical properties by PWHT effect during impressed current cathodic protection. The optimum cathodic protection potential by SSRT was -770 mV(SCE). At the applied cathodic protection potential of -770 mV -850 mV(SCE), the fracture morphology was dimple pattern with ductile fracture, while it was transgranular pattern (Q.C: quasi cleavage) under -875 mV(SCE).

  • PDF

Numerical analysis results of the cathodic protection for the underground steel pipe by anode installation method

  • Jeong, Jin-A;Choo, Yeon-Gil;Jin, Chung-Kuk;Park, Kyeong-Wan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1212-1216
    • /
    • 2014
  • This study aims to find out the best anode location for buried pipelines. Numerical simulation program known as CATPRO (Elsyca, Belgium) were used for confirming the best location of anodes and the effects of impressed current cathodic protection system. Applied conditions for numerical simulation were similar to on-site environmental conditions for optimal application of cathodic protection system. Used criterion of cathodic protection was NACE SP 0169, which describes that minimum requirement for cathodic protection is -850mV vs. CSE. Various layouts for anodes' installation were applied, which were distance between anodes, anode installation location, and applied current. The areas where cathodic protection potential was lower than -850mV vs. CSE was limited up to 50m from anode installation locations. It was founded numerical analysis obtain cost-effective and efficient cathodic protection methods before design and application the impressed cathodic protection system to on-site environment.