• Title/Summary/Keyword: implantable electrode

Search Result 19, Processing Time 0.026 seconds

Development of 3-Dimensional Polyimide-based Neural Probe with Improved Mechanical Stiffness and Double-side Recording Sites (증가된 기계적 강도 및 양방향 신호 검출이 가능한 3차원 폴리이미드 기반 뉴럴 프로브 개발)

  • Kim, Tae-Hyun;Lee, Kee-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1998-2003
    • /
    • 2007
  • A flexible but implantable polyimide-based neural implant was fabricated for reliable and stable long-term monitoring of neural activities from brain. The developed neural implant provides 3-dimensional (3D) $3{\times}3$ structure, avoids any hand handling, and makes the insertion more efficient and reliable. Any film curvature caused by residual stress was not observed in the electrode. The 3D flexible polyimide electrode penetrated a dense gel whose stiffness is close to live brain tissue, because a ${\sim}1{\mu}m$ thick nickel was electroplated along the edge of the shank in order to improve the stiffness. The recording sites were positioned at both side of the shank to increase the probability of recording neural signals from a target volume of tissue. Impedance remained stable over 72 hours because of extremely low moisture uptake in the polyimide dielectric layers. At electrical recording test in vitro, the fabricated electrode showed excellent recording performance, suggesting that this electrode has the potential for great recording from neuron firing and long-term implant performance.

Caudal Neuromodulation with the Transforaminal Sacral Electrode (InterStim): Experience in a Pain Center Regarding 12 Implants

  • Guardo, Laura Alonso;Gala, Carlos Cano;Poveda, David Sanchez;Juan, Pablo Rueda;Sanchez Montero, Francisco Jose;Garzon Sanchez, Jose Carlos;Lamas, Juan Ignacio Santos;Sanchez Hernandez, Miguel Vicente
    • The Korean Journal of Pain
    • /
    • v.29 no.1
    • /
    • pp.23-28
    • /
    • 2016
  • Background: Sacral nerve stimulation is a therapeutic option with demonstrated efficacy for conditions presenting with perineal pain caused by different etiologies. We aimed to assess whether a sacral electrode ($Interstim^{(R)}$, Medtronic, Minneapolis, MN, USA) inserted through the caudal pathway is able to offer an acceptable level of sacral stimulation and rate of catheter migration. Methods: We present 12 patients with pelvic pain who received sacral neuromodulation via the sacral hiatus with the InterStim electrode. We evaluated patient satisfaction as well as migration and removal of the electrode, if necessary. Results: Our experience included 12 patients, 10 women and two men, with a mean age of 60 years. In eight of the 12 patients, the initial therapy was effective, and the final system implantation was performed. During subsequent follow-up, patient satisfaction was good. To date, there have been no cases of electrode displacement or migration. Conclusions: The caudal insertion of the InterStim electrode, with its own fixation system, and initially designed for transsacral insertion, appears in our experience to be a satisfactory option which can minimize electrode displacements, achieving similar results in therapeutic efficacy and causing no difficulties in removal.

BIocompatible Reduced Graphene Oxide Multilayers for Neural Interfaces

  • Kim, Seong-Min;Ju, Pil-Jae;An, Guk-Mun;Kim, Byeong-Su;Yun, Myeong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.278.1-278.1
    • /
    • 2013
  • Among the prerequisites for stable neural interfacing are the long-term stability of electrical performance of and the excellent biocompatibility of conducting materials in implantable neural electrodes. Reduced graphene oxide offers a great potential for a variety of biomedical applications including biosensors and, particularly, neural interfaces due to its superb material properties such as high electrical conductivity, decent optical transparency, facile processibility, and etc. Nonetheless, there have been few systematic studies on the graphene-based neural interfaces in terms of biocompatibility of electrode materials and long term stability in electrical characteristics. In this research, we prepared the primary culture of rat hippocampal neurons directly on reduced graphene oxide films which is chosen as a model electrode material for the neural electrode. We observed that the viability of primary neuronal culture on the present structure is minimally affected by nanoscale graphene flakes below. These results implicate that the multilayer films of reduced graphene oxides can be utilized for the next-generation neural interfaces with decent biocompatibility and outstanding electrical performance.

  • PDF

Electrochemical Properties of Indium Tin Oxide Electrodes Immersed in a Cell Culture Medium with Fetal Bovine Serum (Fetal Bovine Serum을 포함한 세포 배양액에 담근 Indium Tin Oxide 전극 계면의 전기화학적 특성)

  • Choi, Won Seok;Cho, Sungbo
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.34-39
    • /
    • 2013
  • For the biocompatibility test of implantable devices or for the sensitivity evaluation of biomedical sensors, it is required to understand the mechanism of the protein adsorption and the interaction between the adsorbed proteins and cells. In this study, the adsorption of proteins in a cell culture medium with fetal bovine serum onto an indium tin-oxide electrode was characterized by using linear sweep voltammetry and impedance spectroscopy. We immersed the fabricated ITO electrodes in the culture medium for 30, 60, or 90 min, and then measured the electrochemical properties of electrodes with 10 mM $Fe(CN){_6}^{3-/4-}$ and 0.1 M KCl electrolyte. With an increase of contacting time, the anodic peak current was decreased and the charge transfer resistance was increased. However, both parameters were recovered to the values before contact with the medium after the treatment of Trypsin/Ethylenediaminetetraacetic acid hydrolyzing proteins.

Development of Enzyme Immobilization Method to Remove Interference by Physiological Chemicals for Implantable Glucose Sensors (이식형 혈당 센서의 생리활성 물질에 의한 방해 효과를 제거하기 위한 새로운 효소고정법 개발)

  • Chung, T.D.;Kim, H.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.72-73
    • /
    • 1998
  • A new method for enzyme immobilization has been developed to remove interference by potential interferents in body fluids. Instead of using electron mediators, we chose direct hydrogen peroxide measurement route. Extremely hydrogen peroxide-selective polymer was coated as an inner membrane to exclude interferents and then glucose oxidase(GOx) was entrapped by electropolymerization of inert monomers. There was no solvent casting step throughout the whole fabrication procedure but all membranes on Pt-Ir electrode were formed by electropolymerization. Thus, membrane thickness, quantity of enzyme loaded and can be controlled by electrochemical parameters. As a result, reproducibility of biosensor characteristics becomes remarkably improved in terms of mass production.

  • PDF

Atrial pacemaker implantation through left subclavian vein puncture (쇄골하정맥을 이용한 J 형의 전극도자를 가진 심방 Pacemaker 이식치험 2예)

  • Lee, Du-Yeon;Hong, Seung-Rok;Lee, Ung-Gu
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.190-198
    • /
    • 1983
  • The management of cardiac arrhythmias by cardiac pacing has increased greatly since the treatment of complete heart block with an external transcutaneous pacemaker in 1952, followed by the use of myocardial wires connected to an external pulse generation, by external transvenous pacing, and then by transvenous pacing with implantable components in thoracic wall.By now, the three bases of modern cardiac pacing for bradyarrhythmias had been established [1] an implantable device [2] the transvenous approach [3] the ability of the pacemaker to sense cardiac activity and modify its own function accordingly. In transvenous implantation of a pacemaker, any one of four vessels at the root of the neck is suitable for passage of the electrode - cephalic vein, external jugular vein, internal jugular vein, costo-axillary branch of the axillary vein. The new technique of direct puncture of the subclavian vein, either percutaneously or after skin incision only has been made, is invaluable & is used routinely. We have experienced one 25 years old patient who had rheumatic mitral stenosis & minimum aortic regurgitation with sinus bradycardia associated with premature atrial tachycardia & another 54 years old female patient who was suffered from sick sinus syndrome with sinus bradycardia & sinus arrest. The 1st patient was taken open mitral commissurotomy & aortic valvuloplasty and then was taken atrlal pace-maker implantation through If subclavian puncture method in post-op 14 days, and the second patient was taken atrial pacemaker implantation through If subclavian puncture method. Their postop course was in uneventful & were discharged, without complication. Their condition have been good to now.

  • PDF

Synthesis of Li2PtO3 Thin Film Electrode by an Electrostatic Spray Deposition Technique

  • Oh, Heung-Min;Kim, Ji-Young;Lee, Kyung-Keun;Chung, Kyung-Yoon;Kim, Kwang-Bum
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.45-49
    • /
    • 2010
  • $Li_2PtO_3$ thin film electrodes, which might be possible candidate for the cathode materials for implantable batteries, were synthesized using an electrostatic spray deposition (ESD) technique onto a platinum foil substrate. Single phase $Li_2PtO_3$with a structure similar to layered $LiCoO_2$ structure were synthesized by spraying a precursor solution of $CH_3CO_2Li2H_2O$ in ethanol onto a Pt substrate at temperatures ranging from 200 to $400^{\circ}C$ followed by annealing at above $600^{\circ}C$. Lithium carbonate was the only major phase at temperatures up to $500^{\circ}C$. The X-ray diffraction (XRD) peaks of the Pt foil substrate and lithium carbonate disappeared at temperatures >$600^{\circ}C$. The volumetric capacity of the $Li_2PtO_3$ thin film synthesized using the ESD technique was approximately 817 mAh/$cm^3$, which exceeded that of $LiCoO_2$ (711 mAh/$cm^3$).

Development of Micro Wired pH Electrode for Real-Time Monitoring for Gastroesophageal Reflux (위식도 역류 실시간 모니터링 마이크로 와이어 pH 전극 개발)

  • Kim, Eung-Bo;Lee, Kyu-Jin;So, Sang-Kyun;Joung, Yeun-Ho;Park, Jung Ho;Kim, Nam Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents an implantable pH measurement electrode for wireless gastroesophageal reflux measurement. Usually, gastroesophageal reflux is diagnosed by a catheter-type wire connection between the esophagus and the diagnostic device which brings many side effects such as restriction of daily living, pain, and discomfort in the nasal cavity and pharynx of patients. In order to solve these issues, researchers have been studied a wireless measurement method and a micro-sized pH electrode for human body insertion is necessary. Commercial glass packaged pH meter is formed by a sensing and a reference electrodes in a KCl solution. However, if the glass meter is inserted into the human body, there are risks of leakage of the solution, breakage of the glass package, injury of the body elements. Therefore, the solution should be solidified on the micro-sized noble metal wire which has a characteristic of biocompatible. After solidified wire fabrication, the designed meter was tested for feasibility of measurement and the result was well agreed with pH values of commercial pH meter. Potentials in pH 1 to 12 solution was measured to obtain the sensitivity of the sensor with linearity. And we have designed a simulation of gastroesophageal reflux with symptom frequency, interval, and duration time in pH 2 solution. The proposed sensor has capable to get the same potential for 24 measurements in 3 days, and it has sensed same pH values of 2 for one hour with every 10 minutes. Furthermore, the sensor was survived for 48 hours with reasonable potentials in the acid solution.

Skeletal Muscle Ventricle Mechanics (골격근 심실의 역학)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.428-432
    • /
    • 1999
  • Background: It has been shown that low-grade electrical stimulus can transform fatigue resistant muscles which then can be used to protect the heart. The bulky and cumbersome power sources of the artificial heart or implantable ventricular assist devices are still in need of solution; however, on the other hand, the implantable ventricular assist devices using the resistant muscles as the power source have the advantages of using its own muscle contractions. The purpose of this study was to determine the possibility of a clinical application of the skeletal muscle ventricle. Material and Method: Latissimus dorsi muscles (LDM) of 8 canines were used for skeletal muscle ventricle. A latex chamber was wrapped one and a half times with LDM. The chamber was attached to a pressure transducer via Tygon tube. An electrode stimulator was placed around the thoracodorsal nerve and LDM was stimulated in cyclic bursts of 0.31 sec on time and 6.0 sec off time using 3.0 volt Itrel stimulator. The preload volume was added to the system in 25cc increments. Ejection volumes, pressures, and peak power outputs were measured. Result: Ejection volume was 76.3cc with 0cc of preload. Ejection volumes were less than 70ml with increments of preload over 75cc Pressures were more than 107 mmHg when the preloads were less than 75cc and less than 100 mmHg when the preloads were more than 100cc. Peak power output of 16.6 W/kg was observed at 50cc preload. Conclusion: Depending on the changes of preload, the volumes ejected from skeletal muscle ventricle and pressures from the skeletal muscle contraction surpassed those of the normal heart. These data suggest that there are clinical applications for skeletal muscle ventricular assist system.

  • PDF