TiN/Ti 다층막 코팅된 생체용 Ti-30Ta-xZr 합금의 부식특성 (Corrosion Characteristics of TiN/Ti Multilayer Coated Ti-30Ta-xZr Alloy for Biomaterials)

  • 김영운;조주영;최한철
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.162-169
    • /
    • 2009
  • Pure titanium and its alloys are drastically used in implant materials due to their excellent mechanical properties, high corrosion resistance and good biocompatibility. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus than cortical bone. Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. For this reason, Ti-30Ta-xZr alloy systems have been studied in this study. The Ti-30Ta containing Zr(5, 10 and 15 wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24 hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and Ti coating and then coated with TiN, respectively, by using DC magnetron sputtering method. The analyses of coated surface were carried out by field emission scanning electron microscope(FE-SEM). The electrochemical characteristics were examined using potentiodynamic (- 1500 mV~+ 2000 mV) and AC impedance spectroscopy(100 kHz~10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The equiaxed structure was changed to needle-like structure with increasing Zr content. The surface defects and structures were covered with TiN/Ti coated layer. From the polarization behavior in 0.9% NaCl solution, The corrosion current density of Ti-30Ta-xZr alloys decreased as Zr content increased, whereas, the corrosion potential of Ti-30Ta-xZr alloys increased as Zr content increased. The corrosion resistance of TiN/Ti-coated Ti-30Ta-xZr alloys were higher than that of the TiN-coated Ti-30Ta-xZr alloys. From the AC impedance in 0.9% NaCl solution, polarization resistance($R_p$) value of TiN/Ti coated Ti-30Ta-xZr alloys showed higher than that of TiN-coated Ti-30Ta-xZr alloys.

전 슬관절 치환 성형술에 사용되는 초고분자량 폴리에틸렌 삽입물의 접촉응력에 관한 유한요소해석 (Finite Element Analysis for the Contact Stress of Ultra-high Molecular Weight Polyethylene in Total Knee Arthroplasty)

  • 조철형;최재봉;최귀원;윤강섭;강승백
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권1호
    • /
    • pp.37-44
    • /
    • 1999
  • 인공 슬관절에 사용되는 초고분자량 폴리에틸렌(Ultra-high molecular weight polyethylene : UHMWPE)의 마모는 삽입물의 수명을 결정하는 주요 요인으로 작용한다. UHMWPE의 마모로 입자가 발생하여 조직반응을 일으키고 이에 따른 일련의 반응으로 골용해가 일어나 인공관절의 실패의 원인으로 작용한다. 여러 보고들에 의하면 관절 운동시 발생하는 접촉응력은 UHMWPE의 마모에 영향을 미치는 주요한 인자 중 하나로 알려져 있다. 그러나 이러한 보고들은 관절 접촉면에서의 접촉 조건만을 고려했고 UHMWPE 삽입물을 지지하고 있는 금속 지지판과의 접촉면에서의 접촉 조건은 고려하지 않았다. 본 연구에서는 이러한 접촉 조건들을 고려하여 UHMWPE의 모양, 두께, 마찰, 굴곡 정도 그리고 구성 요소들에 대한 UHMWPE 표면과 내부에서의 응력해석을 통해 이들 변수가 UHMWPE의 마모현상에 미치는 영향을 알아보았다. UHMWPE의 모양에 따른 관절의 일치정도(conformity)에 대한 영향의 경우, 일치정도가 높은 모델이 응력을 줄여줄 수 있는 유형으로 나타났으며, 금속 지지판과의 접촉면에서 접촉조건을 준 경우가 완전히 결합된 것으로 가정한 경우보다 UHMWPE 내부에서의 최대 응력이 1-2mm 더 아래에서 나타났다. 또한 UHMWPE로만 된 유형이 금속 지지판이 있는 유형보다 낮은 응력분포를 보여줌으로써 높은 응력으로 인한 UHMWPE의 마모와 균열을 줄이기 위해서는 UHMWPE로만 된 유형의 삽입물의 사용이 좋을 것으로 사료되었다.

  • PDF