• 제목/요약/키워드: implant overdenture

검색결과 171건 처리시간 0.031초

Open and Closed Mouth Impression Techniques for Mandibular Implant Overdenture: Two Cases Report

  • Ha-Jin, Yoon;Jung-Yoon, Bae
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.152-161
    • /
    • 2022
  • Mandibular implant overdenture is a good treatment option for complete edentulous patients with restoring removable prosthesis. Mandibular implant overdenture with two implants and locator attachments is widely used. It is tissue-supported overdenture that is made with the concept of conventional complete denture fabrication. There are two patients who provided impressions by open mouth technique and closed mouth technique in each case. In both cases, mandibular implant overdentures were restored with functionally and aesthetically satisfying results.

하악 임플랜트 유지형 피개의치의 안정성과 하악골 응력분포에 대한 3차원 유한요소법적 연구 (3D FINITE ELEMENT ANALYSIS OF OVERDENTURE STABILITY AND STRESS DISTRIBUTION ON MANDIBULAR IMPLANT-RETAINED OVERDENTURE)

  • 홍해룡;최대균;백진;권긍록
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.633-643
    • /
    • 2007
  • Statement of problem: Recently there are on an increasing trend of using implants-especially in edentulous mandible of severly alveolar bone recessed. Purpose: The aim of this study was to analyze the displacement and stress distribution of various mandibular implant-retained overdenture models supported by two implants in interforaminal region under the occlusion scheme load. Material and method: FEA models were made by the 3D scanning of the edentulous mandibular dentiform. The three models were named as Model M1, M2, and M3 accord ing to the position of implants: M1, Lt. incisor area, M2, Canine area, and M3, 1st Premolar area. Inter-implant angulation model was named as M4. Conventional complete denture was named M5 and used as a control group. Ball implant and Gold matrice were used as a retentive anchors. The occlusion type loads were applied horizontally over each tooth. Results: 1. In mandibular implant retained overdenture Canine Protected Occlusion type load resulted in higher levels of stress to the implants and female matrices than other types of loads. 2. The overdenture model M1, with implants in lateral incisor areas resulted in lower stress concentration to the implants and female matrices than other models. 3. In mandibular implant retained overdenture the stresses of the implant and female matrice were lower in mesially inclined implant than these of parallel installed implant. Conclusion: Lateral incisor areas could be the best site for the implants in mandibular implant-retained overdenture. The mandibular implant retained overdenture models mentioned above showed to the lowest stress to the implants and female matrices.

임플란트의 수와 어태치먼트의 종류에 따른 하악 임플란트 지지 오버덴춰의 삼차원 광탄성 응력분석 (A THREE DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS OF IMPLANT-SUPPORTED MANDIBULAR OVERDENTURE ACCORDING TO IMPLANT NUMBER AND ATTACHMENT TYPE)

  • 한상훈;태윤섭;진태호;조혜원
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.577-608
    • /
    • 1997
  • The purpose of this study is to evaluate the stress distribution in the bone around dental implants supporting mandibular overdenture according to the number of implant and the type of attachment. Two or four implants were placed in an edentulous mandibular model and three dimensional photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure and also to calculate principal stress components at cervical area of each implant. The attachments tested were rigid and resilient type of Dolder bar, Round bar, Hader bar and Dal-Ro attchment. The results were as follows ; 1. In 2-implant supported overdenture using Round bar, Hader bar, and Dal-Ro attachment, compressive stress pattern was observed on the supporting structure of implant on loaded side, while tensile stress pattern in unloaded side. 2. In 2-implant supported overdenture using Dolder bar, the rigid Dolder bar shared the occlusal loads between 2 implants in a more favorable manner than was exhibited by the resilient type, while the resilient type placed a more stress on the distocervical area of the implant on the loaded side. But compressive stress pattern was observed in both the loaded and unloaded sides in either case. 3. In 2-implant supported overdenture, rigid and resilient type of Dolder bar exhibited more cross arch involvement than the Round bar, Hader bar, or Dal-Ro attachment. 4. In 4-implant supported overdenture using resilient Dolder bar and Hader bar, stress turned out to be distributed evenly among the implants between loaded and unloaded side, but thor was no reduction in the magnitude of the stress in the surrounding structure of implant contratry to 2-implant supported overdenture. 5. The stress pattern at cervical area of implant was different with the number of implant or the type of attachment but the overload, harmful to surrounding structure of implant, was not observed.

  • PDF

Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws

  • Carlsson, Gunnar E.
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.245-252
    • /
    • 2014
  • PURPOSE. To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. MATERIALS AND METHODS. Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. RESULTS. Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. CONCLUSION. In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results.

Restoration of Mandibular Edentulous Patient By Dental Implant: Case Report

  • Kwon, Ji-Yung;Kim, Yung-Soo
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.360-365
    • /
    • 2000
  • The completely edentulous patient has few treatment options in conventional dentistry. When implants are considered, treatment plans range from a 2-implant overdenture to a completely implant-supported prosthesis. Fixed prosthesis is often the preferred selection of the edentulous patient. fixed full-arch cert amo-metal restorations can be a predictable implant treatment modality for the edentulous patient. Implant-supported fixed prosthesis has several advantages: predictability, fixedness, retrievability, improved function, lower maintenance of prosthesis, long-term published success. Edentulous patients with a severely resorbed mandible often experience problems with their dentures. Treatment concepts involving two to four implants for the support of an overdenture have been proposed. There seems to be no need to insert more than two endosteal implants to support an overdenture, however, long-term prospective studies are needed to support this notion. Using short endosseous implants and an overdenture in the extremely resorbed mandible is a justified treatment option because of the relative simplicity and low morbidity of this treatment strategy. Implant-supported overdenture has several advantages: Cost, retrievability, hygiene access, profile and contour control, increased retention and stability, implant installed in a predicted region(ant. mandible).

  • PDF

Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient

  • Ha, Seung-Ryong;Kim, Sung-Hun;Song, Seung-Il;Hong, Seong-Tae;Kim, Gy-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.254-258
    • /
    • 2012
  • Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar$^{(R)}$ is prefabricated and can be adjustable at chairside. Therefore, laboratory procedures such as soldering and welding are unnecessary, which leads to fewer errors and lower costs. A 67-year-old female patient presented, complaining of mobility of lower anterior teeth with old denture. She had been wearing complete denture in the maxilla and removable partial denture in the mandible with severe bone loss. After extracting the teeth, two implants were placed in front of mental foramen, and SFI-Bar$^{(R)}$ was connected. A tube bar was seated to two adapters through large ball joints and fixation screws, connecting each implant. The length of the tube bar was adjusted according to inter-implant distance. Then, a female part was attached to the bar beneath the new denture. This clinical report describes two-implant-supported overdenture using the SFI-Bar$^{(R)}$ system in a mandibular edentulous patient.

이중관 구조 하악 임플랜트 피개의치의 응력 분포에 관한 유한요소법적 분석 (Finite Element Analysis of Stress Distribution on Telescopic System for Mandibular Implant Supported Overdenture)

  • 오정란;우이형;이성복;백진
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.359-371
    • /
    • 2008
  • 연구목적: 본 연구에서는 하악의 동일한 부위에 4개의 임플랜트를 식립하여 임플랜트 피개의치를 설계하는 경우, 바 구조와 이중관 구조 간의 응력분포에 대해 비교 분석하고자 하였다. 연구재료 및 방법: 하악골, 하악골에 식립한 4개의 임플랜트, 일차고정의 바 연결 상부구조, 이차고정의 이중관 상부구조를 삼차원 유한요소 모델링하였고, 상부 구조물에 최대 교두 감합위를 재현하는 수직하중과 측방운동시 작업측의 군기능을 재현하는 경사하중을 가하고, 최대 응력과 응력분포를 하악골, 임플랜트 지대주, 임플랜트 상부 구조물에서 분석하였다. 결과: 1. 악골에서의 최대 응력값은 경사하중을 제외하고 수직하중과 작업측 경사하중에서 이중관 구조가 바 구조에 비해 다소 적은 응력값을 보였다. 이중관 구조가 바 구조에 비해 비교적 악골 전체에 고르게 응력이 분포되었다. 2. 지대주에서는 모든 하중 조건에서 이중관 구조가 바 구조에 비해 낮은 응력값을 보였다. 응력 분포 양상은 두 구조에서 모두 비슷한 양상을 나타내었으며, 최후방 지대주의 원심면에 응력이 집중되었다. 3. 상부구조물에서는 모든 하중 조건에서 이중관 구조가 바 구조에 비해 높은 응력값을 나타냈다. 그러나, 바 구조에서는 바의 각 중심부와 지대주와의 연결부위, 지대주의 치경부에 응력이 집중된 반면, 이중관 구조에서는 상부 구조물 전체에 비교적 고른 응력 분포를 보였다. 결론: 본 연구 결과 이중관 구조가 바 구조보다 악골과 지대주에서는 더 낮은 응력을, 상부 구조물에서는 더 큰 응력을 나타냈다. 상부 구조물에 비교적 크게 전달되는 응력을 견딜 수 있는 상부구조물의 설계와 재료 선택만 이루진다면, 응력분포 면에서 이차고정을 하는 이중관 구조가 일차 고정하는 바 구조에 비해 유리하리라 생각된다.

두 개의 수술용 가이드와 Milled-bar를 이용한 임플란트 피개 의치 수복 증례 (Implant-supported milled bar overdenture with two implant surgical guides)

  • 윤필상;김선재;표세욱;장재승
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.55-62
    • /
    • 2023
  • 완전 무치악 환자에게서 잔존 치조골의 흡수가 심할 경우 의치의 저작효율과 안정성 향상을 위해 임플란트로부터 지지를 얻는 피개의치를 고려해볼 수 있다. 임플란트 식립 위치를 선정할 때 디지털 진단 프로그램을 이용하면 환자의 해부학적 요소와 최종보철물의 형태를 고려한 수술용 가이드를 만들어 임플란트 수술의 정확도를 높일 수 있다. 임플란트 지지 피개의치에서 다양한 부착장치 중 milled bar 경우 임플란트간의 연결고정 효과뿐만 아니라 견고한 지지를 얻을 수 있는 이점이 있다. 이에 본 증례에서는 치조골 삭제 전, 후의 상황을 가정한 두 개의 수술용 가이드를 이용하여 임플란트를 식립한 후 milled bar를 이용한 임플란트 피개의치를 장착해주어 기능적이고 심미적인 결과를 얻었다.

Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysis

  • Hussein, Mostafa Omran
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.333-340
    • /
    • 2013
  • PURPOSE. This study was accomplished to assess the biomechanical state of different retaining methods of bar implant-overdenture. MATERIALS AND METHODS. Two 3D finite element models were designed. The first model included implant overdenture retained by Hader-clip attachment, while the second model included two extracoronal resilient attachment (ERA) studs added distally to Hader splint bar. A non-linear frictional contact type was assumed between overdentures and mucosa to represent sliding and rotational movements among different attachment components. A 200 N was applied at the molar region unilaterally and perpendicular to the occlusal plane. Additionally, the mandible was restrained at their ramus ends. The maximum equivalent stress and strain (von Mises) were recorded and analyzed at the bone-implant interface level. RESULTS. The values of von Mises stress and strain of the first model at bone-implant interface were higher than their counterparts of the second model. Stress concentration and high value of strain were recognized surrounding implant of the unloaded side in both models. CONCLUSION. There were different patterns of stress-strain distribution at bone-implant interface between the studied attachment designs. Hader bar-clip attachment showed better biomechanical behavior than adding ERA studs distal to hader bar.

하악 임플란트지지 오버덴춰에서 바 어태치먼트의 유지력이 임플란트의 축력에 미치는 영향 (EFFECTS OF OVERDENTURE RETENTION ON THE AXIAL LOAD OF IMPLANT IN THE MANDIBULAR IMPLANT-SUPPORTED OVERDENTURE)

  • 조혜원
    • 대한치과보철학회지
    • /
    • 제38권1호
    • /
    • pp.98-107
    • /
    • 2000
  • Three linear strain gauges (KFR-02N-120-C1-23, Kyowa, Japan) were placed around the abutment of implant future and the maximum axial loads on the mandibular implants supporting over dentures were registered in experimental model when the overdenture was removed. The overdenture attachments used in this study were Round bar Hader bar, Dolder bar with and with out spacer. The retention of bar attachment was measured using universal testing machine while being con-trolled by Activating set and Deactivator except in case of the Hader bar. Simultaneously strains were recorded with the strain smart program in strain P-6000 series (Measurement group, Raleigh, USA). The maximum axial load was calculated and compared with each other. The results were as follows: 1. The amount and the timing of the maximum axial loads were different between the right and left implant in all attachment systems. 2. The retention of bar attachment except Hader bar could be adjusted but the controllability was different among the attachment systems. 3. The more the axial load, the higher the retention with Hader bar and Dolder bar without spacer. but the tendency of increase was not shown with round bar and Dolder bar with spacer.

  • PDF