• 제목/요약/키워드: implant impression

검색결과 110건 처리시간 0.032초

Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions

  • Ozcan Akkal;Ismail Hakki Korkmaz;Funda Bayindir
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권4호
    • /
    • pp.179-188
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS. A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS. While the Primescan (PS) impression group had the highest accuracy with 38 ㎛, the values of 104 ㎛ and 171 ㎛ were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively (P = .001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners (P < .001). While the lowest angular deviation was obtained with the PS impression group with 0.185°, the values of 0.499° and 1.250° were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values (P > .05). CONCLUSION. A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group.

Open and Closed Mouth Impression Techniques for Mandibular Implant Overdenture: Two Cases Report

  • Ha-Jin, Yoon;Jung-Yoon, Bae
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.152-161
    • /
    • 2022
  • Mandibular implant overdenture is a good treatment option for complete edentulous patients with restoring removable prosthesis. Mandibular implant overdenture with two implants and locator attachments is widely used. It is tissue-supported overdenture that is made with the concept of conventional complete denture fabrication. There are two patients who provided impressions by open mouth technique and closed mouth technique in each case. In both cases, mandibular implant overdentures were restored with functionally and aesthetically satisfying results.

새로운 인상용 코핑을 이용한 임플란트 인상법의 정확성에 대한 3차원적 비교 연구 (Three Dimensional Comparative Study On The Accuracy Of Impression Technique Using New Impression Coping)

  • 김세라;김인수;박성재;이병옥;고석민
    • 구강회복응용과학지
    • /
    • 제26권3호
    • /
    • pp.323-337
    • /
    • 2010
  • 본 연구는 임플란트 상부 구조물 제작을 위한 pick-up 인상 채득시 flag type의 새로운 인상용 코핑을 이용하여 제작된 모형과 기존에 사용되고 있는 인상용 코핑에 의해 제작된 모형의 정확성을 3차원적으로 비교하여 새로운 형태의 인상용 코핑을 사용한 인상법의 유용성을 알아보고자 하였다. 아크릴릭 레진 블록으로 좌측은 전부 무치악, 우측은 제 2 소구치가 상실된 상악 기준 모형을 제작하였다. 상악 우측 제 2소구치, 좌측 중절치, 좌측 견치, 좌측 제 2 소구치, 좌측 제 2 대구치 부위에 외부 육각 연결 방식의 임플란트 고정체를 식립하였다. 기준 모형에 사용된 인상용 코핑 및 코핑 간에 연결 여부에 따라 세 가지 실험군으로 분류하였다; 임플란트 고정체에 flag type 의 인상용 코핑을 체결한 경우 (실험군 I), 기존 형태인 원통형의 인상용 코핑을 체결한 후 인상용 코핑을 자가 중합 아크릴릭 레진으로 연결한 경우 (실험군 Ii), 원통형 인상용 코핑을 체결한 후 자가 중합 레진으로 연결하지 않은 경우 (실험군 III). 총 15개의 모형을 제작하여 인상 채득하여 작업 모형을 제작한 후 기준 모형 및 작업 모형을 5번씩 측정하여 통계 처리하였다. flag type의 인상용 코핑을 이용하여 인상 채득한 군, 기존의 인상용 코핑을 자가 중합 레진으로 splinting하여 인상 채득한 군, 기존의 인상용 코핑을 splinting 하지 않고 인상 채득한 군의 작업 모형에서 각 임플란트 유사체 간 거리 차이는 통계적으로 유의하지 않았다(P >.05). 또한 동일 수평면에 대한 수직적 거리를 비교한 결과 flag type의 인상용 코핑을 사용하여 제작한 작업 모형이 Point 2에서는 기준 모형에 가장 근접한 수치를 보였고 Point 3에서는 오차가 가장 컸으며 이는 통계적으로 유의하였다(P <.05). 그 외 Point에서는 세 가지 방법 간에 통계적으로 유의한 차이는 없었다(P >.05). 새로운 인상용 코핑을 사용한 인상법은 기존의 인상용 코핑을 사용한 인상법과 비교적 유사한 정확성을 보여주었다.

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Lee, Sang-Jik;Cho, Sung-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.177-185
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

스캔이 가능한 치유지대주를 이용한 구치부 단일 임플란트 수복 증례 (Posterior single implant prosthesis using scannable healing abutment)

  • 김성민;이규복
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.432-438
    • /
    • 2019
  • 임플란트 보철 치료의 성공에 정확한 인상 채득은 매우 중요한 과정이다. 이러한 임플란트 보철의 인상을 채득하는 방법에는 임프레션 코핑과 인상재를 이용한 전통적인 방법과 구강 스캐너와 디지털 인상 코핑(scanbody)을 이용한 디지털 인상채득법이 있다. 하지만 인상용 코핑과 scanbody는 모두 구강 내 치유 지대주(healing abutment)를 제거하고 장착해야 한다. 때문에 술자는 치유 지대주와 임프레션 코핑 또는 scanbody를 여러 번 체결하고 제거하는 과정을 반복해야 한다. 뿐만 아니라 임프레션 코핑 또는 scanbody는 교합면보다 높게 솟아 있어 환자는 지속적으로 개구 상태를 유지해야 하는 불편을 주기도 한다. 이러한 기존의 방법을 극복하고자 최근에는 치유 지대주에 scanbody의 스캔 가능 부분(scannable part)을 부여하여 치유 지대주를 제거할 필요 없이 구강 내에서 직접 구강 스캐너로 스캔이 가능한 치유지대주(scannable healing abutment)가 소개되었다. 스캔이 가능한 치유지대주를 이용하여 구치부 단일 임플란트를 수복한 증례를 소개하고자 한다.

임상적 방법을 이용한 내부연결 임플랜트에서 고정체수준 인상법의 정확도 평가 (EVALUATION OF THE ACCURACY OF FIXTURE-LEVEL IMPRESSION TECHNIQUE FOR INTERNAL CONNECTION IMPLANT USING CLINICAL METHODS)

  • 최정한
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.421-431
    • /
    • 2006
  • Statement of problem : Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression technique in internal connection implant system. Purpose: This study evaluated the accuracy of splinted fixture-level impression technique using clinical methods and the effect of internal hex on fit of superstructure in internal connection implant system (Astra Tech). Material and method : Two metal master frameworks made from two abutments (Cast-to Abutment ST) each for parallel and divergent conditions and a corresponding. passively fitting, dental stone master cast with four future replicas (Fixture Replica ST) were fabricated. Ten dental stone casts were made with vinyl polysiloxane impressions from the master cast by acrylic resin splinted fixture-level impression technique. To evaluate the accuracy of impression technique, the fit of master frameworks for test models was evaluated using screw resistance test (SRT) and one-screw test. The results of SRT were recorded as SRT values from grade 1 to grade 5 by 1/4 turn. And to evaluate the effect of hex on fit of superstructure, the same tests were performed after removing hexes of master frameworks. Results: 1. There was only one case (2.5%) showing SRT value of test model below ade 2 in total before and after removing hexes of master frameworks. And, by removing hexes. SRT values decreased in only one test model (5%) and did not change in 17 test models (85%). 2. SRT values of the 1$^{st}$ screws were grade 2 in 80% of cases before, and grade 1 in 80% of cases after removing hexes. And, by removing hexes, SRT values decreased in 72.5% of cases. 3. SRT values of the 2$^{nd}$ screws were grade 3 in 85% of cases before, and grade 3 in 95% of cases after removing hexes. And, by removing hexes, SRT values did not change in 85% of cases. 4. There were only 2 cases regarded as acceptable fit by one-screw test, and SRT values of 2$^{nd}$ screws of both cases were grade 2. Conclusion. Within the limitations of this study, future-level impression of internal connection implant system is considered to obtain inaccurate working cast, even using acrylic resin splinted impression technique. And, it is considered to be unable improve the fit to remove the hexes of implant restoration.

심한 하악 치조제 흡수를 가진 환자에서 임플란트를 이용한 가철성 국소의치로 수복한 증례 (Implant-assisted removable partial denture for severely atrophied mandible)

  • 최바다;김연주;이재훈
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.171-175
    • /
    • 2019
  • 치조제가 심하게 흡수된 하악의 정확한 해부학적 구조를 채득하는 것은 매우 어렵다. 이 경우 보다 정확한 인상을 채득하기 위하여 수정모형 제작법을 통한 기능 인상 채득이 추천된다. 이를 위해서는 양측에 2개의 임플란트 크라운을 이용하여 적절한 고정원을 얻을 필요가 있다. 이를 통해 임플란트 피개의치에서는 불가능하였던 수정모형 제작법을 시행할 수 있다. 본 증례에서는 하악의 치조제가 심하게 흡수된 80세 여환을 하악 양측 견치 부위의 임플란트 크라운을 지대치로 한 가철성 국소의치를 이용하여 수복하였다. 가철성 국소의치의 금속구조물을 이용하여 개인 트레이를 제작하고 수정모형 제작을 위한 이차 인상을 채득하였다. 환자는 앞선 2회의 피개의치 실패 후 제작된 최종 보철물에 만족하였다. 치료 초기에 행해진 피개의치 치료에서는 부정확한 인상법에 따른 부적절한 보철물로 인해 술자와 환자 모두 만족하지 못했지만, 2개의 임플란트를 적절한 고정원으로 이용함으로써 성공적인 수복이 가능하였다.

Accuracy of a proposed implant impression technique using abutments and metal framework

  • Lee, Hyeok-Jae;Lim, Young-Jun;Kim, Chang-Whe;Choi, Jung-Han;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권1호
    • /
    • pp.25-31
    • /
    • 2010
  • PURPOSE. This study compared the accuracy of an abutment-framework (A-F) taken with open tray impression technique combining cement-on crown abutments, a metal framework and resin cement to closed tray and resin-splinted open tray impression techniques for the 3-implant definitive casts. The effect of angulation on the accuracy of these 3 techniques was also evaluated. MATERIAL AND METHODS. Three definitive casts, each with 3 linearly positioned implant analogs at relative angulations 0, 30, and 40 degrees, were fabricated with passively fitted corresponding reference frameworks. Ten impressions were made and poured, using each of the 3 techniques on each of the 3 definitive casts. To record the vertical gap between reference frameworks and analogs in duplicate casts, a light microscope with image processing was used. Data were analyzed by two-way analysis of variance and the Tukey test. RESULTS. The open tray techniques showed significantly smaller vertical gaps compare to closed tray technique (P < .05). The closed tray and the resin-splinted open tray technique showed significantly different vertical gaps according to the angulation of implant (P < .05), but the A-F impression technique did not (P > .05). CONCLUSION. The accuracy of the A-F impression technique was superior to that of conventional techniques, and was not affected by the angulation of the implants.

인상채득법이 임플랜트 주모형의 정확성에 미치는 영향 (EFFECT OF IMPRESS10N TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS)

  • 김영오;양홍서;방몽숙;박상원;박하옥;이재봉
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.63-72
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and Method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on future level (Group FIX-D), 2) Indirect method on fixture level(Group FIX-I), 3) Modified indirect method on fixture level(Group FD(-M), 4) Direct method on abutment level(Group AB-D) and 5) Indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^(R)$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results: The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2 In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error.

임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교 (Comparative accuracy of implant impression techniques with different splinting materials)

  • 홍기윤;신수연
    • 구강회복응용과학지
    • /
    • 제39권1호
    • /
    • pp.9-20
    • /
    • 2023
  • 목적: 하악 부분 무치악 모형에서 pick-up type 인상용 코핑을 사용한 개방형 인상 채득법과 transfer type 인상용 코핑을 사용한 폐쇄형 인상 채득법, 개방형 인상 채득법에서 pick-up type 인상용 코핑 고정 재료에 따른 인상 채득 정확성을 비교 하고자 하였다. 연구 재료 및 방법: 하악 부분 무치악 모형의 좌측 구치부에 직경 4.5 mm, 길이 11.5 mm의 임플란트 고정체 두 개 식립 후 3D 프린터를 이용하여 개방형 개인 트레이 30개 폐쇄형 개인 트레이 10개를 제작하였다. 제작한 개인 트레이를 이용하여 PN군: 개방형 인상 채득법(non-splint), PG군: 개방형 인상 채득법(splint GC pattern resin), PH군: 개방형 인상 채득법(splint Herifix), TN군: 폐쇄형 인상 채득법으로 나누어 각 군당 10회씩 총 40회의 인상 채득을 진행하였다. 인상채득 후 석고 모형을 제작하여 모델 스캐너로 스캔 후 역설계 프로그램으로 스캔오차를 측정하여 95% 유의수준으로 평가 하였다. 결과: 폐쇄형 인상 채득법 TN군이 개방형 인상 채득법 PN군 보다 더 낮은 오차값을 보였다. 개방형 인상 채득법(splint)에 사용된 인상용 코핑 고정 재료 간의 비교 결과에서는 PH군에서 가장 낮은 오차값을 보였으며 PN군, PG군 순으로 정확한 인상 채득 정확성을 보여주었다. 결론: 임플란트 인상 채득 방법이나 인상용 코핑의 연결 고정 유무에 따른 각 군 간의 정확성에 유의한 차이는 없다.