• Title/Summary/Keyword: implant impression

Search Result 109, Processing Time 0.025 seconds

Sinus floor elevation and implant-supported fixed dental prosthesis in the posterior area, with full-digital system: a case report (완전 디지털 시스템을 이용한 상악동 거상술 및 구치부 임플란트 고정성 보철 수복 증례)

  • Gang Soo Park;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.157-164
    • /
    • 2024
  • A variety of digital technologies are being used throughout the entire implant treatment process of diagnosis, surgery, impression, design, and fabrication of prostheses. In this case, using a digital surgical guide, sinus floor elevation was performed without complications, and the implants were placed in the planned position. After the healing period for osseointegration, CAD-CAM (Computer-aided design-Computer-aided manufacturing) customized abutments and provisional prostheses were delivered. While using the provisional prosthesis, occlusal change was observed. To transfer the intermaxillary relationship and abutment position that reflect occlusal change and axial displacement, double scanning and abutment-level digital impressions were taken. Abutment superimposition was used to capture the subgingival margin without gingival retraction. Then, the definitive prosthesis was designed and fabricated with digital system. We report a case applying digital system, to achieve the predictable result as well as the efficient treatment process from implant surgery to fabricating prosthesis in the posterior area.

Different Bone Graft Materials in Intrabony Defects (치조골내낭에 수종의 골이식재 이식후 혈소판 유래 성장인자의 분포에 관한 면역조직화학적 연구)

  • Um, Heung-Sik;Han, Soo-Boo;Lee, Jae-Il;Kim, Hyun-Jong;Chang, Beom-Sek
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.45-59
    • /
    • 1997
  • Platelet-derived growth factor(PDGF) has been shown to play an important role in periodontal regeneration. The purpose of the present study was to examine the distribution of PDGF in experimentally created periodontal intrabony defects after flap surgery with various bone graft materials. Six healthy mongrel dogs were used in this study. Three-wall bony defects were created in maxillary and mandibular premolars, inflammation induced by wire ligation and injection of impression material into the defects. Eight weeks later, the experimental lesions thus obtained were treated by plain flap surgery(control group), flap surgery plus autogenous bone graft(autogenous bone group), flap surgery plus Biocoral graft(Biocoral group), or flap surgery plus bioglass graft(bioglass group), which were randomly assigned to the defects. After 4, H, and 12 weeks postoperatively, 2 dogs were sacrificed at each time and 1he specimens were taken for histological examinations and immunohistochemical examinations for PDGF. In the control defects the amount of new bone formation was minimal. In the autogenous bone and Biocoral group new bone was deposited around implanted particles and the amount of new bone was increased with time. A large number of bioglass particles exibited a central excabation and bone formation could be observed in the central excabation as well as around the particles. The expression of PDGF was low in the control group. The expression of PDGF in Biocoral group was increased at 1, H week, but decreased at 12 week. The increased PDGF expression in autogenous bone and bioglass group was maintained to the end of the experiment.

  • PDF

Treatment Protocol for Cleft Lip and/or Palate Children in Kyushu University Hospital

  • Suzuki, Akira
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.15 no.2
    • /
    • pp.69-82
    • /
    • 2012
  • Our Team Approach consists of following five stages; (1) Peri-natal care until lip repair After ultrasound diagnosis, some obstetricians recommend the mother with CL/P fetus to undergo prenatal counseling in our CLP clinic. On the day the CL/P baby was born, our oral surgeon, nurse, and pedodontist visit the maternity clinic, and take counseling and take impression for a feeding plate. The cheiloplasty is performed in three months old. (2) From lip repair to palatal repair At one year of age, Otorhinolaryngologist checks middle-ear disease. Palatoplasty is carried out at 1.5 - 2 years old. (3) In deciduous and early mixed dentitions Speech is the most important issue in social life for the CL/P subjects, therefore the training of velopharyngeal function is essential. Orthodontist monitors dentofacial development from 5 years of age. In the case of severe maxillary under-growth or severe collapse, maxillary protractor or lateral expansion is indicative, respectively. In early mixed dentition, upper central incisor on the cleft area erupts with some torsion, and then the traumatic occlusion with tooth torsion must be corrected. (4) In mixed dentition Right before the eruption of upper canines, secondary bone grafting is performed. One year prior to the operation, maxillary fan-type expansion is carried out to correct the collapse of maxillary segments. Following the surgical operation, the erupted canine will be moved into the transplanted bone to avoid alveolar resorption. (5) In permanent dentition Final tooth alignment is carried out after eruption of second molars. Some cases may require orthognathic surgery after physical maturation. Prosthetic oral rehabilitation including the dental-implant is carried out after age eighteen.

  • PDF

Geometric Features Detection of 3D Teeth Models using Approximate Curvatures (근사 곡률을 이용한 3차원 치아 모델의 기하학적 특징 검출)

  • Jang, Jin-Ho;Yoo, Kwan-Hee
    • The KIPS Transactions:PartA
    • /
    • v.10A no.2
    • /
    • pp.149-156
    • /
    • 2003
  • In the latest medical world, the attempt of reconstructing anatomical human body system using computer graphics technology awakes people's interests. Actually, this trial has been made in dentistry too. There are a lot of practicable technology fields using computer graphics in dentistry For example, 3D visualization and measurement of dental data, detection of implant location, surface reconstruction for restoring artificial teeth in prostheses and relocation of teeth in orthodontics can be applied. In this paper, we propose methods for definitely detecting the geometric features of teeth such as cusp, ridge, fissure and pit, which have been used as most important characteristics in dental applications. The proposed methods are based on the approximate curvatures that are measured on a 3D tooth model made by scanning an impression. We also give examples of the geometric features detected by using the proposed methods. Comparing to other traditional methods visually, the methods are very useful in detecting more accurate geometric features.

Biological stability of Zirconia/Alumina composite ceramic Implant abutment (지르코니아/알루미나 복합 지대주의 생물학적 안정성에 관한 연구)

  • Bae, Kyu-Hyun;Han, Jung-Suk.;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Cho, Ki-Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.555-565
    • /
    • 2006
  • The purpose of the present study is to evaluate the biological stability of the zirconia/alumina composite abutment by histologic and radiographic examination in clinical cases. 17 partially edentulous patients (5 men and 12 women, mean age 47) were treated with 37 implants. The implants were placed following the standard two-stage protocol. After a healing period of 3 to 6 months, zirconia/alumina composite abutments were connected. All radiographs were taken using paralleling technique with individually fabricated impression bite block, following insertion of the prosthesis and at the 3-, 6-, 12 month re-examinations. After processing the obtained images, the osseous level was calculated using the digital image in the mesial and distal aspect in each implant. An ANOVA and t-test were used to test for difference between the baseline and 3-, 6-, 12 months re-examinations, and for difference between maxilla and mandible. Differences at P <0.05 were considered statistically significant. For histologic examination, sample was obtained from the palatal gingiva which implant functioned for 12 months. Sections were examined under a light microscope under various magnifications. Clinically, no abutment fracture or crack as well as periimplantitis was observed during the period of study. The mean bone level reduction(${\pm}standard$ deviation) was 0.34 rom(${\pm}\;0.26$) at 3-months, 0.4 2mm(${\pm}\;0.30$) at 6-months, 0.62 mm(${\pm}\;0.28$) at 12-months respectively. No statistically significant difference was found between baseline and 3-, 6-, 12-months re-examinations (p > 0.05). The mean bone level reduction in maxilla was 0.33(${\pm}0.25$) at 3-months, 0.36(${\pm}0.33$) at 6-months, 0.56(${\pm}0.26$) at 12-months. And the mean bone level reduction in mandible was 0.35(${\pm}0.27$) at 3-months, 0,49(${\pm}0.27$) at 6-months, 0.68(${\pm}0.30$) at 12-months. No statistical difference in bone level reduction between implants placed in the maxilla and mandible. Histologically, the height of the junctional epithelium was about 2.09 mm. And the width was about 0.51 mm. Scattered fibroblasts and inflammatory cells, and dense collagen network with few vascular structures characterized the portion of connective tissue. The inflammatory cell infiltration was observed just beneath the apical end of junctional epithelium and the area of direct in contact with zirconia/alumina abutment. These results suggest the zirconia/alumina composite abutment can be used in variable intraoral condition, in posterior segment as well as anterior segment without adverse effects.

Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique (다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구)

  • Kim, Dong-Wook;Choi, Yu-Sung;Jo, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.343-358
    • /
    • 2011
  • As implant treatment has become popular, lots of different shapes and materials of the implant upper component have been supplied. And there are also diverse reports about failures including loosening of the abutment screw which is one of the most common reason. Purpose : The purpose of this study is to find out how different screw tightening orders and methods influence on screw loosening according to the different connection systems. The upper component was fabricated by casting method. After fabricating master models that are precisely attached to the upper component, 5 experimental models each for the external connection system and internal connection system were fabricated using splinting impression technique. First, to find out the influence of the screw tightening order, screws were tightened in 3 orders; 1-2-3-4, 2-3-1-4, 2-4-3-1. After tightening, removal torque values (RTV) of each group was measured. And also to find out the influence of screw tightening method, a model with 2-3-1-4 screw tightening order was tightened with 30 Ncm at one time(1-step method) and the RTV was compared with the same order group (2-3-1-4) in the 2 step method. In the external connection system, RTV appeared significantly lower in group 2-3-1-4 than group 2-4-3-1 (p<0.05). And also in the internal connection system, the RTV of group 2-3-1-4 appeared significantly lower than that of group 2-4-3-1 and 1-2-3-4 (p<0.05). When comparing the tightening number of the screw without considering the screw tightening order, the first tightened screw appeared significantly higher RTV than the second one in the external connection system (p<0.05), however there was no significant difference from the first tightened screw to the last tightened screw in the internal connection system. And there was no statistically significant difference between the two screw tightening methods in both internal and external connection system. In the comparison of external and internal connection system, each RTV appeared 16.27 Ncm and 14.25 Ncm and appeared as a statistically significant difference (p<0.05). There was a significant difference in RTV measured according to the screw tightening order. The lowest RTV appeared in the groups started tightening from the middle. There was also a significant difference in RTV between the two connection system groups. A further study is needed to find out the influence factors in RTV and also a study is required related to the load condition.

The treatment of an edentulous patient with DENTCA$^{TM}$ CAD/CAM Denture (CAD/CAM Denture를 이용한 완전 무치악 환자 수복 증례)

  • Park, Joon-Ho;Cho, In-Ho;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.

Effects of platelet-derived growth factor loaded bioresorbable membrane on periodontal regeneration (혈소판유래 성장인자 함유 흡수성 차폐막이 치주조직의 재생에 미치는 영향)

  • Ku, Young;Kim, Jeong-Eun;Han, Soo-Boo;Chung, Chong-Pyoung;Park, Yoon-Jeong;Lee, Seung-Jin;Kwon, Youg-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.61-78
    • /
    • 1997
  • PDGF-BB has been recognized as a highly potential growth factor for guided tissue regeneration in periodontal defect. This study carried out histologic and histometric evaluation of $200ng/cm^2$ PDGF-BB loaded bioresorbable membrane made from polyglycolic and polylactic acid. It was tested for its biocompatibility, ability to prevent epithelial downgrowth and amount of periodontal regeneration. Without membrane and PDGF-BB unloaded bioresorbable membrane were used as control. Healthy six beagle dogs were used. Each dog was anesthetized and buccal flaps were reflected in the mandibular and maxillary premolar areas. Buccal alveolar bone between the mesiobuccal and distobuccal line angles was surgically removed on the lower 2nd and 4th premolar in mandible, 2nd premolar in maxilla, to a level 4mm apical to the cementoenamel junction with creating a Class II buccal furcation defect for available space. Care was taken not to remove the root cementum layer and rubber impression materials were placed over each surgically created defect. Flaps were repositioned and sutured. Reconstructive surgery was performed 1 month after defect preparation. PDGF-BB loaded membranes and controls were randomly placed on maxillary 2nd premolars and mandibular 2nd and 4th premolars. Plaque control regimen was instituted with daily brushing with a 0.1% chlorhexidine digluconate during experimental periods. The animals were sacrificed 2 and 5 weeks after surgery and undecalcified specimens were prepared for histologic evaluation. The degree of coronal regrowth of new bone, new cementum and the amonut of new bone areas formed on the defected area of the PDGF-BB loaded membrnae turned superior to without membrane and drug unloaded membrane. Experimental membrane could prevent the epithelial downgrowth irrespective of drug loaded or not and showed good biocompatiblity, These results implicated that PDGF-BB loaded bioresorbable membrane could be highly useful tool for guided tissue regeneration of periodontal defects.

  • PDF

Difference of perception of the duties of dental hygienist between dentists and dental hygiene students in an area (일개 지역 치과의사와 치위생학과 학생 간 치과위생사의 업무에 대한 인식의 차이)

  • Hwang, Soo-Jeong;Koong, Hwa-Soo;Lee, Sang-Hoon
    • Journal of Korean Academy of Dental Administration
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • Although dental hygienists have performed chair-side assisting and other dental cares as well as preventive dental cares in Korea, medical technician law confines duties of dental hygienists as closed narrative. The aim of this study was to investigate difference in perception of duties of dental hygienists in dental clinic between dentists and dental hygiene students. A total of 245 copies of questionnaires were distributed to dentists and students by post-mail. Only 42 dentists and 30 students in an area replied these questionnaires about the present and future duties of dental hygienists after providing written consent. Both groups agreed that intra and extra oral X-ray taking, education about oral health behavior, instruction after dental treatment, chair-side assisting, consulting for patients, scaling, initial impression taking, management of dental materials and equipment, sterilization of equipment, and receiving dental bills are duties of dental hygienists. However, they had different perceptions about various dental treatments as duties of dental hygienists even if they were under instructions of a dentist, including infiltration anesthesia, filling in cavity, intramuscular injection, FC change, canal irrigation, orthodontic treatment including separating, ligature bracket bonding and removing, setting crown and bridge, making individual, removing implant screw, and so on. These findings demonstrated that there were different perceptions about duties of dental hygienists between dentists and dental hygiene students, especially on dental treatment.