• Title/Summary/Keyword: implant fixture

Search Result 328, Processing Time 0.028 seconds

Maxillary Sinus Augmentation Using Macroporous Biphasic Calcium Phosphate ($MBCP^{TM}$) : Three Case Report With Histologic Evaluation (합성골 이식재인 Macroporous biphasic calcium phosphate를 이용한 사람의 상악동 거상술-증례 보고)

  • Lee, Ji-Hyun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.567-577
    • /
    • 2006
  • Background Several bone grafting materials have been used in sinus augmentation procedures. Macroporous Biphasic Calcium Phosphate($MBCP^{TM}$) consists of the mixture of 60% HA and 40% ${\beta}-TCP$. Therefore, it can provide good scaffold for the new bone to grow owing to HA, in the other hand, it can have bioactivity for bone remodeling owing to ${\beta}-TCP$. The purpose of this study was to evaluate bone formation following maxillary sinus augmentation using $MBCP^{TM}$ by means of histologic analysis. Material and Method $MBCP^{TM}$ was placed as a primary bone substitute for maxillary sinus augmentation. Three patients were selected after evalaution of their medical dental examination. $MBCP^{TM}$ only, $MBCP^{TM}$ combined with Irradicated cancellous bone and $MBCP^{TM}$ combined with autogenous bone were used for each patient. After about eight months, bone biopsies were harvested for histologic evaluation and fixtures installed. Results Eight months after surgery we observed new vital bone surrounding $MBCP^{TM}$ particle and the amount of new bone was about 30% even though there were discrepancies between specimens. This case report documents that $MBCP^{TM}$ when used as a grafting material for sinus floor augmentation whether combined other bone graft material or not, may lead to the predictable results for dental implants on posterior maxillary area with insufficient vertical height for fixture installation.

The accuracy evaluation of digital surgical stents according to supported type (디지털 수술용 가이드의 지지타입에 따른 정확도 평가)

  • Lee, Junyoun;Yoon, Minho;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.8-16
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the accuracy of surgical stent according to the supported type. Materials and methods: 5 sets of dental models which have tooth supported edentulous area and tooth-tissue supported edentulous area were made. Dental model were scanned with model scanner, and CBCT was taken. CT data and model scan data were overlapped using In2Guide software, implant were virtually planned in the software. Surgical stents are fabricated by 3D printing. The implant fixture were installed using the surgical stent, CBCT were retaken. CBCT before surgery and after surgery were overlapped, and the differences (angle difference, coronal difference, apical difference) were evaluated using statistical analysis. Results: In the assessment of the accuracy of surgical guides according to arch type, there are no statistically significant differences between maxilla and mandible. In the case of support type, tooth supported stents showed lower angle difference and length difference than tooth-tissue supported stents, which are statistically significant. Conclusion: Arch type does not affect the accuracy of surgical stents. But tooth support stents are more accurate than tooth-tissue support stents in the case of angle and length difference.

Influence of Implant Abutment Systems on Detorque Value and Screw Joint Stability (임플랜트 지대주 종류가 나사풀림력과 연결부의 안정성에 미치는 영향)

  • Bae, Byung-Ryong;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.97-109
    • /
    • 2010
  • Purpose : This study was designed to evaluate the influence of implant abutment materials on detorque value and screw joint stability before and after dynamic fatigue test. Materials & Methods : The external hexagonal fixture and three different groups of abutment (titanium abutments, zirconia abutments, and UCLA abutments) were used. The detorque value before loading and after loading (cyclic loading up to $10^5$ cycles) of the abutment screw were measured. Result : 1. There was no significant difference in detorque value before loading among the each group. 2. There was no significant difference in detorque value after loading among the each group. 3. Detorque values before and after cyclic loading in each group were not significantly different. 4. There was no significant difference in loss percentage of removal torque before loading among the each group. 5. There was no significant difference in loss percentage of removal torque after loading among the each group. 6. There was no significant difference in loss percentage of removal torque according to loading among the each group. Conclusion : Short term screw loosening of three types of abutment was not significantly different. When bite force was applied, there was no significant difference in screw loosening between before loading and after loading.

Effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized implants coated with heparin for improving alveolar ridge augmentation in beagle dogs: Radiographic observations (양극산화 임플란트 표면에 적용된 헤파린과 골형성단백질(rhBMP-2)이 치조골 증대에 미치는 효과: 방사선학적 평가)

  • Lee, So-Hyoun;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.307-314
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized titaum implants coated with heparin to enhance the vertical alveolar ridge augmentation in the supraalveolar peri-implant defect region. Materials and methods: 18 pure titanium implants (7.0 mm in length, 3.5 mm in diameter) were manufactured for this study. All implants were anodized and designed insertion reference line marked with laser at the apical 2.5 mm from the fixture platform. Implantation of 6 noncoated anodized implants (Control group), 6 anodized implants physically adsorbed with rhBMP-2 by dip and dry method (BMP group) and 6 anodized implants chemically immobilized 3,4-dihydroxyphenylalanine (DOPA)-heparin/ rhBMP-2 (Hep-BMP group) was performed in the both mandibular of three male adult beagle dogs using split-mouth design. Radiologic examinations were performed immediately after implant placement and 4 and 8 weeks after implant placement. The amount of mesio-distal bone augmentation was evaluated by measuring the vertical distance from the platform to the marginal bone. Statistical analysis was performed using one-way analysis of variance (SPSS version 18.0) and multiple comparison analysis of The Kruskal-Wallis test and the Mann-Whitney U test. Statistical significance was established at the 5% significant level. Results: At the 4 weeks vertical alveolar ridge augmentation of Control group, BMP group and Hep-BMP group is $0.09{\pm}0.22mm$, $1.02{\pm}0.72mm$, and $1.29{\pm}0.51mm$, At the 8 weeks $0.11{\pm}1.26mm$, $1.11{\pm}0.58mm$, $1.59{\pm}0.79mm$ according to radiographic observations. The two experimental groups showed a significantly increasing in vertical bone height compared with the control group (P<.05). However, there is no significant difference between the BMP group and Hep-BMP group (P>.05). Conclusion: The rhBMP-2 coated implants were enhanced the vertical bone growth in the supraalveolar peri-implant defect area. However, there is no significant difference between chemically and physically coating method.

The influence of intentional mobilization of implant fixtures before osseointegration (골유착전 임플란트 고정체의 의원성 동요가 골결합에 미치는 영향)

  • Cho, Jin-Hyun;Jo, Kwang-Heon;Cho, Sung-Am;Lee, Kyu-Bok;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the influence of mobilization on bone-implant interface prior to osseointegration of fixtures. Materials and methods: The experimental implants (3.75 mm in diameter, 4.0 mm in length) were made of commercially pure (Grade IV) titanium, and were treated with RBM ($MegaGen^{(R)}$: Ca-P). The 80 implants (two in each tibia) were inserted into the monocortical tibias of 20 rabbits which each weighed more than 3.5 kg (Female, New Zealand White). According to the removal torque interval, the groups were divided into 10 groups, Group I (6 wks), Group II (4 days+6 wks), Group III (4 days+1 wk+6 wks), Group IV (1 wk+6 wks), Group V (1 wk+1 wk+6 wks), Group VI (2 wks+6 wks), Group VII (2 wks+ 1 wk+6 wk), Group VIII (3 wks+6 wks), Group IX (3 wks+1 wk+6 wks) and Group X (10 wks). The control groups were Group I and X, the removal torque was measured at 6 wks and 10 wks with a digital torque gauge (Mark-10, USA). In the experimental groups, the removal torque was given once or twice before the final removal torque and the value was measured each time. After which, the implants were put back where they had been except the control groups. All the experimental groups were given a final healing time (6 wks) before the final removal torque test, in which values were compared with the control groups and the 1st and/or 2nd removal torque values in each experimental group. Results: In the final removal torque tests, the removal torque value of Group X (10 wks) was higher than that of Group I (6 wks) in the control groups but not statistically different. There were no significant differences between the experimental groups and control groups (P>.05). In the first removal torque comparison, the experimental groups (4 days or 1 wk) values were significantly lower than the other experimental groups (2 wks or 3 wks). In the comparison of each experimental group according to healing time, the final removal torque value was significantly higher than the 1st torque test value. Conclusion: Once or twice mobilization of fixture prior to osseointegration did not deter the final bone to implant osseointegration, if sufficient healing time was given.

Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment (임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교)

  • Choi, Jae-Won;Chae, Sung-Ki;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.173-180
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the retentive characteristics of the additional attachments used with implant bar attachment under repeated insertion/removal cycles. Materials and methods: The newly developed attachment and the commercially available attachment were investigated: ADD-Lock (AL), Locator blue (LB). Two fixtures were placed parallel to each other on the custom lower mounting, and patrix of each attachment was fixed to the fixture. Also, the matrix of each attachment was placed on the opposing upper mounting. A universal testing machine was used to measure the retentive force during initial, 100, 250, 500, 1000, 2000, and 2500 repeated insertion/removal cycles. Wear and deformation of the attachment s were observed by scanning electron microscopy (SEM). Mann-Whitney U test (α=.05) and wilcoxon signed-rank test (α=.05) were performed to compare retentive force between each group and before and after 2500 repeated insertion/removal cycles. Results: In terms of initial retentive force and retentive force after 2500 repeated insertion/removal cycles, the AL group (15.24 ± 1.46 N and 9.74 ± 1.16 N) showed significantly smaller values than the LB group (43.53 ± 12.39 N and 22.99 ± 4.77 N) (P<.05). Also, in the loss of retentive force, the AL group (5.50 ± 1.08 N, 36.08%) showed a smaller value than the LB group (20.54 ± 11.89 N, 47.19%) (P<.05). Based on SEM analysis, The AL group showed noticeable wear and deformation in the patrix and the LB group in the matrix. Conclusion: Locator showed a higher initial retentive force than newly developed attachment, while the loss of retentive force was also higher. Both additional attachments are considered to have sufficient retentive force after repeated insertion/removal cycles.

A BIOLOGIC STUDY ON TOOTHASH - PLASTER OF PARIS MIXTURE WITH ABSORBABLE COLLAGEN MEMBRANE IN THE TREATMENT OF PERI-IMPLANT DEFECTS (임플란트 주위염 치료시 치아회분말과 치과용 연석고의 혼합 매식의 골재생 효과)

  • Choi, Hee-Yeon;Kim, Hak-Kyun;Kim, Su-Gwan;Moon, Seong-Yong;Kim, Sang-Yeol;Park, Kwang-Bum;Kim, Young-Min;Lim, Seong-Chul;Kim, Eun-Seok;Lee, Jeong-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.2
    • /
    • pp.142-149
    • /
    • 2008
  • The purpose of this study was to evaluate histomorphometrically a toothash - plaster of Paris mixture associated with collagen membrane ($Bio-Gide^{(R)}$), regarding new bone formation in the peri-implantitis defects in dogs. Three mandibular molars were removed from 1-year-old mongrel dogs. After 2 months of healing, 2 titanium implants with sandblasted with large grit and acid etched (SLA) surface were installed in each side of the mandible. Experimental peri-implantitis was induced with ligatures after successful osseointegration. Ligatures were removed after identification of bone defect beneath the level of 5th thread of fixture on radiographic image. The mucoperiosteal flaps were elevated and the contaminated fixtures were treated with chlorhexidine and saline. The bone defects were assigned to one of the following treatments: no guided bone regeneration (GBR) procedure (group 1), GBR with Bio-$Oss^{(R)}$ and Bio-$Gide^{(R)}$ (group 2), or GBR with toothash - plaster of Paris mixture (TPM) and Bio-$Gide^{(R)}$ (group 3). The dogs were sacrificed after 8 or 16 months. The mean percentages of new bone formation within the limits of the 5 most coronal threads were $17.83{\pm}10.69$ (8 weeks) and $20.13{\pm}13.65$ (16 weeks) in group 1, $34.25{\pm}13.32$ (8 weeks) and $36.33{\pm}14.21$ (16 weeks) in group 2, and $46.33{\pm}18.39$ (8 weeks) and $48.00{\pm}17.78$ (16 weeks) in group 3, respectively. The present study confirmed statistically considerable new bone formation within the threads in group 3 compared with group 1 at 8 and 16 weeks (P<0.05). Although, data analysis did not reveal significant differences between group 2 and 3, the latter showed better results during the period of 8 or 16 weeks. Our findings support the effectiveness of TPM as a GBR material in the treatment of peri-implantitis bone defect.

A three-dimensional finite element analysis of osseointegrated implant on stress distribution in different abutment designs and fixture diameters (각종 지대주 및 고정체 종류에 따른 골유착성 임플랜트의 응력 분포에 관한 삼차원 유한요소분석적 연구)

  • Kwon, Ho-Beom;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.699-721
    • /
    • 1996
  • 브로네마르크가 골유착성 임플랜트를 소개한 이래로, 현재 골유착성 임플랜트에 의한 치료는 안전하고 안정적인 방법으로 여겨지고 있다. 골유착성 임플랜트를 이용한 초기의 치료는 무치악 환자의 저작기능 회복에 중점을 두어 왔다. 그러나 현재는 환자와 시대의 요구에 따라서 심미성이 주요한 관심사가 되었다. 그래서 표준 지대주보다 더 심미적인 지대주 시스템들이 개발되었다. 다양한 직경의 임플랜트 고정체에 관한 임상가들의 요구에 의해 직경 이 큰 고정체가 생산되기 시작했으며, 5mm의 직경을 갖는 고정체가 그 예이다. 골유착성 임플랜트를 사용하여 보철치료를 할 때, 골과 고정체의 계면은 보철물과 지대주에 가해지는 교합력을 인접골에 전달하게 되며, 이것은 계면에 생물학적인 반응을 야기할 수 있다. 임플랜트의 형태는 골흡수와 같은 바람직하지 않은 반응을 일으키지 않도록 고안되어야 하며, 임플랜트 자체가 교합력을 견딜 수 있어야 한다. 그러므로 골유착성 임플랜트 시스템을 임상에 사용하려고 할 때 이것의 생역학적 분석은 반드시 필요하다. 본 연구에서는 삼차원 유한요소분석적 방법을 사용하여 3.75mm직경을 갖는 고정체에 표준 지대주, 이세티콘 지대주, 마이러스콘 지대주를 연결한 모델과 5mm 직경을 갖는 고정체에 표준 지대주를 연결한 모델에 각각 수직하중, 경사하중, 수평하중을 가했을 때의 응력분포를 비교하였다. 본 연구의 결과는 다음과 같다. 1. 모든 모델에서 금나사의 경부, 금원주, 지대주에 응력의 집중이 일어났다. 2. 임플랜트 고정체에서는 고정체 상방 2/3, 그리고 지대주와 접촉하는 고정체 상면에서 응력의 집중이 관찰되었다. 3. 골에서는 상부 피질골에 응력의 집중이 관찰되었으며, 해면골에서는 두드러진 응력의 집중을 보인 부위는 없었으나 고정체의 근단부 주위 해면골에서의 응력값이 비교적 높았다. 4. 5mm 직경의 고정체를 사용하지 않은 모델 중에서, 표준 지대주를 사용한 경우가 가장 응력분산에 유리하였으며 마이러스콘 지대주를 사용한 경우가 가장 불리하였다. 5. 3가지 하중 조건하에서 수평하중과 경사하중의 경우가 수직하중의 경우보다 더 높은 응력값이 관찰되었다. 6. 응력값은 골에서보다 임플랜트 내부에서 훨씬 높았다.

  • PDF