• 제목/요약/키워드: implant fixture

검색결과 328건 처리시간 0.026초

임프란트 식립을 위한 상악동 거상술의 임상적 연구 (A CLINICAL STUDY OF MAXILLARY SINUS LIFT FOR DENTAL IMPLANT)

  • 이성재;장현석;이부규;권종진;임재석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권4호
    • /
    • pp.376-381
    • /
    • 1999
  • A variety of materials and procedures such as sinus floor elevation, sinus-lift graft, inlay bone graft using Le Fort I osteotomy, and onlay graft have been used to create adequate bone volume in the maxillary sinus for placement of endosseous implants in the posterior atrophic maxilla. Because of the frequent lack of bone in the posterior maxilla, sinus lift procedure has become a commonly practiced treatment modality. The 138 endosseous implants of 36 patients with sinus augmentation procedures performed in Korea University Hospital from January 1991 to December 1998 were summarized and analysed. The result of this study were as follows: 1. Age ranged from 39 to 57, with a mean of 50.7. 2. The mean survival rate for 138 implants with maxillary sinus lift procedure was 80.4%. 3. There was no corelationship between the fixture length, width and the survival rate. 4. The result showed that the healing period for 8-12 months was necessary if the residual alveolar bone height was less than 5mm. 5. Autogenous iliac corticocancellous block graft showed the most favorable survival rate(95%).

  • PDF

Surface alterations following instrumentation with a nylon or metal brush evaluated with confocal microscopy

  • Kim, Young-Sung;Park, Jun-Beom;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • 제49권5호
    • /
    • pp.310-318
    • /
    • 2019
  • Purpose: Surface alterations of titanium discs following instrumentation with either a nylon brush or a metal brush were evaluated. Methods: A total of 27 titanium discs with 3 surface types (9 discs for each type), including machined (M) surfaces, sandblasted and acid-etched (SA) surfaces, and surfaces treated by resorbable blast media (RBM), were used. Three discs were instrumented with a nylon brush, another 3 discs were instrumented with a metal brush, and the remaining 3 discs were used as controls for each surface type. Surface properties including the arithmetic mean value of a linear profile (Ra), maximum height of a linear profile (Rz), skewness of the assessed linear profile (Rsk), arithmetic mean height of a surface (Sa), maximum height of a surface (Sz), developed interfacial area ratio (Sdr), skewness of a surface profile (Ssk), and kurtosis of a surface profile (Sku) were measured using confocal microscopy. Results: Instrumentation with the nylon brush increased the Ra, Sa, and Sdr of the M surfaces. On the SA surfaces, Ra, Sa and Sdr decreased after nylon brush use. Meanwhile, the roughness of the RBM surface was not affected by the nylon brush. The use of the metal brush also increased the Ra, Sa, and Sdr of the M surface; however, the increase in Sdr was not statistically significant (P=0.119). The decreases in the Rz, Sz, Ra, Sa, and Sdr of the SA surfaces were remarkable. On the RBM surfaces, the use of the metal brush did not cause changes in Ra and Sa, whereas Rz, Sz, and Sdr were reduced. Conclusions: Titanium surfaces were altered when instrumented either with a nylon brush or a metal brush. Hence, it is recommended that nylon or metal brushes be used with caution in order to avoid damaging the implant fixture/abutment surface.

다수치아를 상실한 엇갈린 교합 환자에서 임플란트와 $Locator^{(R)}$ attachment를 이용한 가철성 국소의치 증례 (Removable partial denture restoration using single implant supported with $Locator^{(R)}$ attachment in a crossed occlusion patient: a case report)

  • 신운철;방몽숙;양홍서;박상원;임현필;윤귀덕
    • 대한치과보철학회지
    • /
    • 제51권2호
    • /
    • pp.113-118
    • /
    • 2013
  • 다수 잔존치를 상실한 경우 잔존치간의 관계가 역학적으로 불리한 상황에 놓일 수 있다. 환자가 의치에 관한 거부감이 없을 때, 이러한 경우 피개의치를 고려할 수 있지만, 무치악 부위에 임플란트를 이용함으로써 역학적인 불리함을 극복하고 국소의치의 지지, 안정, 유지를 향상시킬 수 있다. 본 증례는 소수 잔존치간에 엇갈린 교합을 보이는 환자로 상악 치아에 대합되는 하악의 무치악 부위에 단일 임플란트를 식립하고 $Locator^{(R)}$ attachment를 연결하여 상하악 국소의치로 치료하였다. 기존의 기울어진 교합평면을 이상적으로 재설정하여 환자의 심미적 만족도를 향상시켰다. 치료 이후 6개월간의 임상 관찰에서 환자는 심미적, 기능적으로 만족하고 안정적으로 유지되었기에 보고하고자 한다.

내측 연결 임플란트에서 지대주 내부길이가 나사 풀림에 미치는 영향 (Influence of internal connection length on screw loosening in internal connection implants)

  • 김지선;박영범;최현민;김성태;김현철;김선재;문홍석;이재훈
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.251-257
    • /
    • 2017
  • 목적:본 연구에서는 long internal connection 형태의 임플란트 지대주를 내부 연결 길이에 변화를 주어 임플란트-지대주 결합부의 안정성을 비교 평가해 보고자 하였다. 재료 및 방법: Long internal connection의 임플란트(Replus system, $4.7{\times}11.5mm$)를 각각 지대주의 길이에 따라 4개의 군(1, 2, 3, 4 mm 군)으로 나누었고 총 20개의 시편을 사용하였다. 시편을 레진에 매몰하여 고정시키고 100 N의 힘으로 임플란트 장축에 대해 30도의 각도에서 $1.0{\times}10^6$ 번의 반복하중을 가한 후 하중 전 후의 풀림회전력의 차이를 계산하여 95% 유의수준에서 Kruskal-Wallis 검정 방법을 통해 통계 분석하였다. 결과:지대주 내부 길이에 따른 풀림 회전력의 통계적 유의성은 나타나지 않았으며 (P > .05) 어떤 시편에서도 완전한 나사 풀림이나 나사 파절은 관찰되지 않았다. 결론: 내측 연결 임플란트에서 지대주 내부길이에 따른 나사 풀림의 정도는 차이가 나지 않았다.

골내 임플랜트의 종류에 따른 광탄성 응력 분석 (PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY DIFFERENT TYPE ENDOSSEOUS IMPLANTS)

  • 정재헌;장두익
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.661-678
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of endosseous implants. This investigation evaluated the stress patterns in rectangular photoelastic models produced by four different types of dental implants such as $Br\ddot{a}nemark$, screw type of Steri-Oss, blade type of Steri-Oss, IMZ with IMC and resin tooth using the techniques of quasi-three dimensional photoelasticity. All prostheses were casted in the same nonprecious alloy and were cemented or screwed on their respective implants and abutments. 20 kg of vertical load was applied on the central fossa of casted crown and 16 kg of inclined had was applied on the top third of distal surface of casted crown respectively. The results were as follows : 1. Under the vertical load, screw implants of Steri-Oss and $Br\ddot{a}nemark$ showed increasing stress condition between and around the screw threads along the implant lateral surface and cylindrical implant of IMZ showed the less stress condition along the lateral surface with concentration of stress mostly near the root apex. 2. Under the vertical load, the stress of Steri-Oss blade was distributed uniformly at the alveolar bone under the broad blade. 3. Under the inclined load, the stress concentration of Steri-Oss screw and $Br\ddot{a}nemark$ was developed highly around the mesiocervical bone area on the contralateral side to force application. The stress of $Br\ddot{a}nemark$ with flexible gold glod was more concentrated in the cervical bone area than that of Steri-Oss with stiff screw. 4. Under the inclined load, the stress of Steri-Oss blade broadly was distributed around the mesioceivical bone area and the lower and mesial bone area of the blade. 5. Under the Inclined load, IMZ implant showed the gap between c개wn and fixture due ta deformation of the IMC and IMZ was lower in stress concentration developed around the mesiocervical bone area than $Br\ddot{a}nemark$ and Steri-Oss screw. 6. Under the inclined load, the stress magnitude induced in the mesiocervical bone area of implants was in order of $Br\ddot{a}nemark$, Steri-Oss strew, IMZ and Stsri-Oss blade. 7. Tilting forces as compared to axial forces exerted greater magnitude of stress in the cervical bone area of the implant. 8. In respect of stress distribution, Steri-Oss blade was superior than any other implants and in respect of the stability by horizontal lone, IMB and $Br\ddot{a}nemark$ was inferior than any other implants.

  • PDF

Minimal invasive horizontal ridge augmentation using subperiosteal tunneling technique

  • Kim, Hyun-Suk;Kim, Young-Kyun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.41.1-41.6
    • /
    • 2016
  • Background: The goal of this study was to retrospectively evaluate the prognosis of minimal invasive horizontal ridge augmentation (MIHRA) technique using small incision and subperiosteal tunneling technique. Methods: This study targeted 25 partially edentulous patients (10 males and 15 females, mean age $48.8{\pm19.7years$) who needed bone graft for installation of the implants due to alveolar bone deficiency. The patients took the radiographic exam, panoramic and periapical view at first visit, and had implant fixture installation surgery. All patients received immediate or delayed implant surgery with bone graft using U-shaped incision and tunneling technique. After an average of 2.8 months, the prosthesis was connected and functioned. The clinical prognosis was recorded by observation of the peri-implant tissue at every visit. A year after restoration, the crestal bone loss around the implant was measured by taking the follow-up radiographs. One patient took 3D-CT before bone graft, after bone graft, and 2 years after restoration to compare and analyze change of alveolar bone width. Results: This study included 25 patients and 39 implants. Thirty eight implants (97.4 %) survived. As for postoperative complications, five patients showed minor infection symptoms, like swelling and tenderness after bone graft. The other one had buccal fenestration, and secondary bone graft was done by the same technique. No complications related with bone graft were found except in these patients. The mean crestal bone loss around the implants was 0.03 mm 1 year after restoration, and this was an adequate clinical prognosis. A patient took 3D-CT after bone graft, and the width of alveolar bone increased 4.32 mm added to 4.6 mm of former alveolar bone width. Two years after bone graft, the width of alveolar bone was 8.13 mm, and this suggested that the resorption rate of bone graft material was 18.29 % during 2 years. Conclusions: The bone graft material retained within a pouch formed using U-shaped incision and tunneling technique resulted with a few complications, and the prognosis of the implants placed above the alveolar bone was adequate.

불량 적합 임플란트 보철물의 광탄성 응력 분석 (A photoelastic Stress Analysis of Implant Prosthesis According to Fitness of Super structure)

  • 임현필;허신옥;김홍주;박상원
    • 구강회복응용과학지
    • /
    • 제26권1호
    • /
    • pp.39-46
    • /
    • 2010
  • 임플란트 보철물에 의도적으로 불량 적합을 부여하고, 수직 하중을 가한 후 주변골에 발생되는 응력의 분포를 광탄성 모델을 이용하여 비교 하는 것이다. 광탄성 레진블록 3개를 제작하고 각각에 3개의 Restore$^{(R)}$ $4.0{\times}10$ mm 임플란트를 식립하였다. 대조군은 부적합이 없도록 제작하였고, 실험군은 각각의 금관을 절단하여 $100{\mu}m$의 부적합을 부여한 후 광탄성 응력분석을 시행하였다. 대조군의 경우 하중을 가하지 않으면 응력 집중을 보이지 않았으며, 하중을 가하더라도 그 부위만 응력 집중을 보였고, 중간에 하중을 가하면 전후방으로 응력이 분산되는 양상을 보였다. 의도적으로 부적합을 부여한 경우 하중을 가하지 않더라도 나사를 조이면 고정체 주위에 응력이 발생했고, 하중을 가한 경우 하중을 가한 부위를 포함하여 주변 임플란트에도 응력이 집중되었다. 특히, UCLA로 제작된 보철물이 원추형 중간 지대주를 사용한 경우에 비해 더욱 응력이 집중되었는데, 치근단에서 시작하여 치축을 따라 치경부까지 집중되었다. 보철물의 적합도가 좋지 않은 경우 하중을 가하지 않더라도 응력이 집중되며, 하중을 가할 경우 더욱 심한 응력 집중 양상을 보인다는 점은 정확한 보철물 제작의 중요성을 말하고 있다.

골유착 고정성 보철물 하에서 하중조건에 따른 삼차원 유한요소법적 분석 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE BONE ANCHORED FIXED PROSTHESIS ACCORDING TO THE LOAD CONDITION)

  • 양순익;정재헌
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.780-806
    • /
    • 1995
  • The purpose of this study was to describe the application of 3D finite element analysis to determine resultant stresses on the bone anchored fixed prosthesis, implants and supporting bone of the mandible according to fixture numbers and load conditions. 4 or 6 fixtures and the bone anchored fixed prosthesis were placed in 3D finite element mandibular arch model which represents an actual mandibular skull. A $45^{\circ}$ diagonal load of 10㎏ was labiolingually applied in the center of the prosthesis(P1). A $45^{\circ}$ diagonal load of 20㎏ was buccolingually applied at the location of the 10mm or 20mm cantilever posterior to the most distal implant(P2 or P3). The vertical distribution loads were applied to the superior surfaces of both the right and the left 20mm cantilevers(P4). In order that the boundary conditions of the structure were located to the mandibular ramus and angle, the distal bone plane was to totally fixed to prevent rigid body motion of the entire model. 3D finite element analysis was perfomed for stress distribution and deflection on implants and supporting bone using commercial software(ABAQUS program. for Sun-SPARC Workstation. The results were as follows : 1. In all conditions of load, the hightest tensile stresses were observed at the metal lates of prostheses. 2. The higher tensile stresses were observed at the diagonal loads rather than the vertical loads 3. 6-implants cases were more stable than 4-implants cases for decreasing bending and torque under diagonal load on the anterior of prosthesis. 4. From a biomechanical perspective, high stress developed at the metal plate of cantilever-to-the most distal implant junctions as a consequence of loads applied to the cantilever extension. 5. Under diagonal load on cantilever extension, the 6-implants cases had a tendency to reduce displacement and to increase the reaction force of supporting point due to increasing the bendign stiffness of the prosthesis than 4-implants cases. 6. Under diagonal load on cantilever extension, the case of 10mm long cantilever was more stable than that of 20mm long cnatilever in respect of stress distribution and displacement. 7. When the ends of 10mm or 20mm long cantilever were loaded, the higher tensile stress was observed at the second most distal implant rather than the first most distal implant. 8. The 6-implants cases were more favorable about prevention of screw loosening under repeated loadings because 6-implants cases had smaller deformation and 4-implants cases had larger deformation.

  • PDF

백서에서 난소절제가 티타늄 임플랜트의 골 유착에 미치는 영향 (THE EFFECTS OF OVARIECTOMY ON TITANIUM IMPLANT OSSEOINTEGRATION IN RAT'S TIBIA)

  • 김병민;성일용;박봉수;신상훈;김종렬
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권6호
    • /
    • pp.397-406
    • /
    • 2003
  • The purpose of this study was to observe the titanium implant osseointegration in the osteoporosis-induced animal model. Seventy rats, 11 weeks of age, were divided into two groups : an ovariectomized group and a control group. Titanium screw implants(diameter, 2.0mm; length, 3.5mm) were placed into left tibias of 70 rats, 35 in the control group and 35 in the experimental group. The rats were sacrificed at different time interval (1, 2, 3, 4, 6, 8, and 12 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with fibronectin and CD34 antibody. The results obtained from this study were as follows: 1. Histopathologically findings, newly formed bone was seen at 3 weeks and became lamellar bone at 8 weeks, and mature trabecullar bone was seen at 12 weeks control group. In experimental group, thickness of regenerated bone increased till 8 weeks gradually and mature trabecullar bone was seen at 12 weeks. 2. By histomorphometric analysis, marrow bone density and contact ratio of marrow bone to implant decreased significantly from 8 to 12 weeks in experimental group compared to control group and also total bone to implant contact ratio decreased significantly from 8 to 12 weeks in experimental group. 3. Fibronectin immunoreactivity was strong at 3 weeks control group and reduced after 8weeks gradually. But it was continuously strong from 3 to 8 weeks in experimental group. 4. CD34 immunoreactivity was very strong in the newly formed osteoblasts from 3 to 8 weeks control group. But it reacted minimally later. While in experimental group, it reacted continuously strong from 3 to 12 weeks. The results of this study suggest that osteoporosis is not an absolute contraindication to dental implantation if sufficient period suggested after fixture installation till second stage surgery.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중 및 조임회전각에 미치는 영향 (Influence of Tungsten Carbide/Carbon Coating on the Preload and Tightening Torque of Implant Abutment Screws)

  • 신현모;조욱;정창모
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.53-59
    • /
    • 2009
  • 본 연구는 external butt joint 연결 형태를 가진 임플랜트 시스템에서 티타늄 합금 나사와 텅스텐 카바이드와 탄소로 코팅한 나사의 압축력 및 조임 회전각 측정을 통해 동일한 전하중을 얻는 데 있어 코팅나사 사용이 갖는 임상적 효율성을 간접적으로 비교해 보고자 하였다. 본 연구에서는 Osstem Implant의 US II 시스템 고정체(${\phi}=4mm$)와 Cemented abutment를 사용하여 티타늄 합금(Ta) 지대주 나사 및 텅스텐 카바이드와 탄소로 표면 처리한(WC/CTa) 지대주 나사에 30Ncm의 조임 회전력을 적용한 후 압축력 및 조임 회전각을 측정하였다. 다음 WC/CTa 지대주 나사에서 측정된 압축력의 평균값을 계산하고 이를 Ta 지대주 나사에 적용하여 동일한 압축력이 가해질 때의 조임 회전력 값을 측정하였다. 그리고 실험결과 측정된 조임 회전력의 평균값을 Ta 나사에 적용한 후 조임 회전각을 측정하여 비교해 본 결과 다음과 같은 결론을 얻었다. 30Ncm의 조임 회전력에서 텅스텐 카바이드/탄소 코팅 나사가 티타늄 합금 나사보다 압축력과 회전각이 더 높게 나타났다. 텅스텐 카바이드/탄소 코팅 나사에 30Ncm의 조임 회전력을 적용하여 발생한 압축력을 얻기 위해서는 티타늄 합금 나사의 경우 55.6Ncm의 조임 회전력이 필요하였으며, 회전각에는 두 나사 간에 차이가 없었다.