• 제목/요약/키워드: implant dentistry

검색결과 3,855건 처리시간 0.024초

다양한 유사체액과 인공타액에서 치과용 임플란트의 전기화학적 특성 (Electrochemical Characteristics of Dental Implant in the Various Simulated Body Fluid and Artificial Saliva)

  • 김태한;박근형;손미경;김원기;장승현;최한철
    • 한국표면공학회지
    • /
    • 제41권5호
    • /
    • pp.226-231
    • /
    • 2008
  • Titanium and its alloy have been widely used in dental implant and orthopedic prostheses. Electrochemical characteristics of dental implant in the various simulated body fluids have been researched by using electrochemical methods. Ti-6Al-4V alloy implant was used for corrosion test in 0.9% NaCl, artificial saliva and simulated body fluids. The surface morphology was observed using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The electrochemical stability was investigated using potentiosat (EG&G Co, 263A). The corrosion surface was observed using scanning electron microscopy (SEM). From the results of potentiodynamic test in various solution, the current density of implant tested in SBF and AS solution was lower than that of implant tested in 0.9% NaCl solution. From the results of passive film stability test, the variation of current density at constant 250 mV showed the consistent with time in the case of implant tested in SBF and AS solution, whereas, the current density at constant 250mV in the case of implant tested in 0.9% NaCl solution showed higher compared to SBF and AS solution as time increased. From the results of cyclic potentiodynamic test, the pitting potential and |$E_{pit}\;-\;E_{corr}$| of implant tested in SBF and AS solution were higher than those of implant tested in 0.9% NaCl solution.

External vs internal implant : 각각의 장점과 고려사항 (External vs internal connection implant system)

  • 성동재;홍성진;하승룡
    • 대한치과의사협회지
    • /
    • 제54권3호
    • /
    • pp.184-190
    • /
    • 2016
  • The osseointegration of titanium implants has been examined over the past 50 years. Many implant systems have been introduced and have become popular to the implant dentistry. The designs of the connection between implant fixture and abutment are divided into external vs internal connection. From beginning, the $Br{\aa}nemark$ system was characterized by an external hexagon. Internal connection has been developed to reduce stress transferred to the bone. These differences may have impact on the clinical procedures and protocols, laboratory and components costs, and incidence of complications. Therefore, the clinician has to know the different biomechanical features and understand their implications to produce successful implant-supported prosthesis with an external or an internal connection system.

  • PDF

Diagnosis and Clinical Management of Retrograde Peri-Implantitis Associated with Adjacent Apical Periodontitis: a Case Report

  • Lee, Kwan-Joo;Song, Young Woo;Jung, Ui-Won;Cha, Jae-Kook
    • 대한치과의사협회지
    • /
    • 제58권6호
    • /
    • pp.336-345
    • /
    • 2020
  • Peri-apical implant lesion, also known as 'retrograde peri-implantitis' can occur with multifactorial etiological factors. The purpose of this case report is to demonstrate resolution of periapical implant lesion by removal of causative factors and saving implant by regenerative therapy. A 54-year old male patient with mild dull pain around implant on the right mandibular second premolar area due to persistent peri-apical infection of the adjacent first premolar was treated. Extraction of tooth with symptomatic apical periodontitis and regenerative therapy on the buccal fenestration area of the implant and extraction site were performed. After 6-month reentry, notable regenerated bone tissue around implant was found, and implant placement on the previous extraction site was performed. After 14-month follow-up from the regenerative therapy, neither biological nor mechanical complication could be found around the implant, evidenced by high implant stability, normal clinical probing depth, and absence of discomfort spontaneously and during masticatory function. In conclusion, surgical intervention including regenerative therapy using bone graft and barrier membrane on periapical implant lesion can be suggested as one of the treatment options considering the extent of periapical lesion.

  • PDF

($Xive^{(R)}$)임플란트 식립시 환자 유형 및 식립부 분포와 생존율에 대한 후향적 연구 (A Retrospective study of the type of patients, the distribution of implant and the survival rate of $Xive^{(R)}$ implant)

  • 명우천;이중석;채경준;정의원;김창성;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.523-534
    • /
    • 2007
  • This study is an analysis of types of patients and distribution of implant site and survival rate of $Xive^{(R)}$ implant. The following results on patient type, implant distribution and survival rate were compiled from 324 implant cases of 140 patients treated at the periodontal dept. of Yonsei University Hospital and G dental clinic between February 2003 and April 2006. 1. There are no dissimilarities between men and women, with patients in their 30, 40, 50s accounting for 80% of patients and accounted for 82% of implant treatments; the largest share of patients and implant treatments. 2. Mn, posterior area. accounted for 57% of implant treatments followed by Mx. posterior area(29%), Mx, anterior area(8%) and Mn, anterior area(6%). 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 96% and fully edentulous patient accounted for the remaining 4%. 4. The major cause of tooth loss is periodontal disease, followed by dental canes, trauma and congenital missing. 5, The distribution of bone quality for maxillae was 54,2% for type III, followed by 30.8% for type II, 15% for type IV and 0% for type I. As for mandible, the distribution was 63% for type II, followed by 34% for type III, 2,5% for type I and 0,5% for type IV. 6. The distribution of bone quantity for maxillae was 55% for type C, followed by 35% for type B, 8% for type D and 2% for type A. As for mandible, the distribution was 60% for type B, followed by 32% for type C, 7% for type A and 0% for type D. 7. The majority of implants were those of 9.5-13 mm in length(95%) and regular diameter in width(82%). 8. The total survival rate was 98%. The survival rate was 97% in the maxillae region and 99% in the mandible region. 9. The survival rate in type I was 83%, in type II was 99%, in type III was 97% and in type IV was 100%. As for the bone quantity, the survival rate in type A and D(100%) was most, followed by type B(99%) and type C(96%). The results showed that $Xive^{(R)}$ implant could be used satisfactorily compare for the other implant system. But we most to approach carefully in certain extreme condition especially with poor bone quality and quantity.

Free Design Blade Implant를 이용한 교의치 (A Fixed Bridge with Free Design Blade Implant)

  • 최목균;이봉원;김승기
    • 대한치과의사협회지
    • /
    • 제19권11호통권150호
    • /
    • pp.975-979
    • /
    • 1981
  • In May 1981, the author placed Free Design Blade Implant into a 24-year old female patient with missing teeth of lower left molars, who did not want a removable partial denture. The bone available was good enough and in apparent general good health. The implant bridge was mad by four units, from 1st premolar to implant head, which is now in good esthetics and function.

  • PDF

The evaluation of implant stability measured by resonance frequency analysis in different bone types

  • Sargolzaie, Naser;Samizade, Sarah;Arab, Hamidreza;Ghanbari, Habibollah;Khodadadifard, Leila;Khajavi, Amin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권1호
    • /
    • pp.29-33
    • /
    • 2019
  • Objectives: Bone density seems to be an important factor affecting implant stability. The relationship between bone density and primary and secondary stability remains under debate. The aim of this study was to compare primary and secondary stability measured by resonance frequency analysis (RFA) between different bone types and to compare implant stability at different time points during 3 months of follow-up. Materials and Methods: Our study included 65 implants (BioHorizons Implant Systems) with 3.8 or 4.6 mm diameter and 9 or 10.5 mm length in 59 patients. Bone quality was assessed by Lekholm-Zarb classification. After implant insertion, stability was measured by an Osstell device using RFA at three follow-up visits (immediately, 1 month, and 3 months after implant insertion). ANOVA test was used to compare primary and secondary stability between different bone types and between the three time points for each density type. Results: There were 9 patients in type I, 18 patients in type II, 20 patients in type III, and 12 patients in type IV. Three implants failed, 1 in type I and 2 in type IV. Stability values decreased in the first month but increased during the following two months in all bone types. Statistical analysis showed no significant difference between RFA values of different bone types at each follow-up or between stability values of each bone type at different time points. Conclusion: According to our results, implant stability was not affected by bone density. It is difficult to reach a certain conclusion about the effect of bone density on implant stability as stability is affected by numerous factors.

임플란트 가이드 수술을 위한 Planning 방식에 대한 고찰 (A procedure for the computer-guided implant planning: A narrative review)

  • 김종은;김남훈;박지현;심준성
    • 대한치과의사협회지
    • /
    • 제54권2호
    • /
    • pp.108-122
    • /
    • 2016
  • Prosthetic-driven implant placement is a concept considering the dental implant restoration first based on the final form of that prosthesis to be restored. The latest development of the imaging technology and digital dentistry was able to be obtained the high quality images of CBCT with low radiation exposure and it has also enabled the process to reconstruct the intraoral state in three dimensions due to the development of the intraoral, model and impression scanner. Computer-guided implant placement simulations and template production was able to be more widely used in this context. In this narrative review, the features and the types of implant surgical guides will be introduced. It will also be described the diagnosis and treatment plan using computerguided implant software to reduce the number of visit and to increase the accuracy of the implant surgery through the top-down approach based on the shape and location of the final prosthesis.

  • PDF

불량한 치조제에서의 임플랜트 시술증례 (IMPLANT REHABILITATION IN THE UNFAVORABLE ALVEOLAR RIDGE)

  • 박재범;안상헌;정수일;조병완;안재진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제19권1호
    • /
    • pp.35-44
    • /
    • 1997
  • The most critical factor in determining which type of implant to be used would be the available bone of the patient. Usually a minimum of 5mm in the bone width and 8mm in the bone height is necessary to ensure primary implant stability and maintain the integrity of bone contact surface. Placement of implant is limited by the several anatomic strutures such as maxillary sinus, floor of the nose, inferior alveolar neurovascular bundle and nasopalatine foramen, etc. When severe resorption of alveolar ridge is encountered, implant placement would be a problematic procedure. A number of techniques to improve the poor anatomic situations have been proposed. This article reports 4 cases of patients using surgical procedures such as blade implant technique, cortical split technique in the anterior maxillary area, sinus lifting and lateral repositioning of inferior alveolar nerve, We treated dental implant candidates with unfavorable alveolar ridge utilizing various surgical techniques, resulted in successful rehabilitation of edentulous ridge.

  • PDF

치과 임플란트 실패와 합병증의 후향적 연구 (Dental implant failures and complications - Retrospective study)

  • 박주희;조찬우;우재만;감세훈
    • 대한치과의사협회지
    • /
    • 제57권7호
    • /
    • pp.372-378
    • /
    • 2019
  • The dental implants in modern dentistry brought out a new era in everyday dental practice. Increasing of dental implants usage, various failures and complications has occurred. Failures and complications of dental implant treatments that can happen in implant surgery, in mechanical or prosthetic problem and in biological aspect. The aim of this study was to assess implant failures for 6 years as well as find out how to overcome implant failure. In Jeju National University hospital, 26 dental implants in 17 patients were removed by implant failure through 2013.1.1.-2018.12.31. Each implant failure case was analyzed in report form with various informations about failure retrospectively. The present study showed 26 failed dental implants of 17 patients were removed. 13 implants(50%) of 8 patients(47.06%) were failed before functional loading and 13 implants(50%) of 9 patients(52.94%) were failed after functional loading. 11 implants(42.31%) of 7 patients(41.18%) with medical disease were extracted. 6 implants(23.08%) of 5 patients(29.41%) with additive bone graft were failed. We discuss with 26 failed dental implants of 17 patients about their causes, solutions and prevention retrospectively for 6 past years. Precise diagnosis and treatment planning are needed. Medically compromised patients and patients with implants and additive bone grafts should be cautiously treated with high failing possibilities.

  • PDF

하악에 식립된 Xive implant 환자의 분포 및 식립부 유형과 생존율 (The distribution of Xive implant patients and the type of implant site and survival rate in mandible)

  • 장인권;정의원;김창성;심준성;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제35권2호
    • /
    • pp.437-448
    • /
    • 2005
  • This study is an analysis of distribution of patients who installed Xive implant in Yonsei University Hospital and types of implant site for about 2 years recall check and cumulative survival rate. 41 implant were used in this study. It shows the conclusion below. 1. Patients at the age of 40s and 50s were 60% of all implant cases and average number of implant was 2.4(man), and 1.9(woman). All cases were operated on mandible, 3 implants on anterior region and 38 implants on posterior region. 2. The major cause of tooth loss is dental caries(48.8%), followed by periodontal disease. 3. Most distribution of bone qaulity for mandibular implant site was type II(65.8%) and bone quantity was type B(75.6%). 4. The majority of implants were those of 11, 13mm in length(95%) and regular diameter in width (64%). 5. The 41(19 persons) Xive implants that were placed in the mandibular anterior and posterior region were all survival and showed a 100% 2 year cumulative survival rate. The results provided us with basic data on patient type, implant distribution, bone condition, and survival rate. We wish that our results coupled with other research data helps assist in the further study for better implant success rates, etc.