• Title/Summary/Keyword: implant choice

Search Result 77, Processing Time 0.03 seconds

VERTICAL DISTRACTION OSTEOGENESIS FOR IMPLANT INSTALLATION ON THE RECONSTRUCTED MANDIBLE WITH FREE FIBULAR FLAP (하악골 재건시 사용된 유리비골피판에서 임플란트 식립을 위한 수직적 골신장술)

  • Paeng, Jun-Young;Lee, Jin-Yong;Myoung, Hoon;Hwang, Soon-Jung;Seo, Byoung-Moo;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.579-585
    • /
    • 2006
  • Introduction: The fibular free flap is now considered as the first choice for long mandibular discontinuity defect. In spite of its good bone quality for implant installation, its diameter is too narrow to rehabilitate the masticatory function with implant installation. In this report, distraction osteogenesis was used for the augmentation of bone to install the dental implant in the mandible which was reconstructed with a vascularized fibular free flap. Patients and Methods: Three patients undertook the vertical augmentation of grafted fibular bone and dental implants were installed. On the day 8 post-surgery, the activation of the distractor was started at the rate of 1 mm twice a day. The total amount of distraction was 15 mm in two patients and 12.5 mm in one patient. Twelve implants were installed in three patients. Dental implants were simultaneously installed during removal of the distraction device in two patients. In one patient, the implant installation was delayed after device had been removed. All three patients showed the symptoms of mild to severe postoperative infection during the activation and consolidation. However, the distracted site showed undisturbed bone regeneration. Conclusion: The distraction osteogenesis showed the reliable results for the vertical augmentation of fibular bone which was used for the mandibular reconstruction. However, the great tendency of postoperative infection must be considered and clinically controlled.

A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS (Titanium Implant의 Removal Torque에 관한 연구)

  • Lee, June-Seok;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

Linked (Semi-constrained) Total Elbow Arthroplasty (연결형(반구속형) 주관절 인공 관절 치환술)

  • Jung, Hong Jun;Jeon, In-Ho;Chun, Jae-Myeung;Lee, Tae Kyoon
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.170-177
    • /
    • 2013
  • Total elbow arthroplasty is still in its infancy compared with other arthroplasties, such as knee or hip arthroplasties. Implant design has been evolving with clinical experiences; however, there are only limited data on the long-term clinical outcome of elbow arthroplasty in the literature. The design of total elbow prostheses can be divided into three categories: linked (constrained or semi-constrained), unlinked (unconstrained), and convertible types. The choice between an unlinked (unconstrained) implant and a linked (semi-constrained) implant depends on joint stability and adequacy of the bone stock. Linked elbow arthroplasty has provided high patient satisfaction, and pain relief thanks to proper patient selection, advancement of implant design, improvement in cement techniques, meticulous surgical technique, and appropriate postoperative rehabilitation. Concerns remain about the use of this implant in young or high-demand patients. This article focuses on the linked (semi-constrained) prostheses, which provides an overview of the current state of linked total elbow arthroplasty.

Giant sialolithiasis of the submandibular gland: a case report (악하선에서 발생한 거대 타석증: 증례 보고)

  • Choi, Woo-Sung;Yoon, Hyun-Joong;Lee, Sang-Hwa
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.141-144
    • /
    • 2010
  • Sialolithiasis is the common pathology of salivary gland. The size of sialoliths vary from 1 mm to a few cm, but most of that are less than 10 mm. Large sialoliths (larger than 15 mm) are extremely rare. It is called Giant sialolithiasis or megalith. Symptom of the giant sialolithiasis is similar to that of regular sialolithiasis. First choice of treatment is removal of the stone. Many literatures reported various methods to remove the sialoliths. For this case report, we accidentally found the giant sialolith on the computed tomography taken for dental implant, and successfully removed the stone by minimal invasive surgical approach. Base on this result, we report this case with literature reviews.

Implants in conjunction with removable partial denture (임플란트를 이용한 국소의치 수복)

  • Kim, Seong-Kyun;Yoo, Soo-Yeon;Park, In-Phil;Lee, Joo-Hee
    • The Journal of the Korean dental association
    • /
    • v.49 no.2
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.

Effectiveness of the ultrasonography in the evaluation following orbit wall reconstruction (안와벽 재건술 시행 후 평가방법으로서 초음파의 효용성)

  • Kim, Chang Yun;Yang, Jeong Yeol;Cheon, Ji Seon;Moon, Jae won
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.428-431
    • /
    • 2009
  • Purpose: Blow out fracture resulting from facial trauma is of high frequency among facial bone fractures, and can cause severe complications. So, proper management and close observation after operation are needed. So far, Computed tomography has been the best choice in the evalution following orbit wall reconstruction. However, cost - effectiveness, accessibility to patients and hazard of radiation exposure of computed tomography require supplementary measure for the evaluation following orbit wall reconstruction. This study was performed to describe the effectiveness of ultrasonography in the evalution following orbit wall reconstruction. Methods: A retrospective study was performed on 40 patients who underwent orbit wall reconstruction from June, 2008 to July, 2008. The patients' ages ranged from 13 to 65 years (mean 27.5 years), and this group was compsoed of 27 male and 13 female patients. The follow up period ranged from 2 weeks to 28 weeks (mean 11weeks). Preoperatively, all fractures were diagnosed using computed tomography. Ultrasonography for all cases, and computed tomography for 2 cases were performed for evaluation following orbit wall reconstruction. Results: Reduction of herniated orbital soft tissue and orbit implant was identified by using ultrasonography in 38 cases out of 40 cases. In other cases which we could not identify the orbit implant, computed tomography was performed. Con clusion: Compared to computed tomography, ultrasonography is simple, inexpensive and convenient method. Ultrasonography can be used as supplementary measure to computed tomography in the evaluation following orbit wall reconstruction for elective patients.

Long-term evaluation of autotransplanted third molars (제 3대구치를 이용한 자가치아이식술의 장기적 예후 관찰)

  • Shin, Dong-Seok;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.4
    • /
    • pp.431-435
    • /
    • 2009
  • Purpose: The purpose of this study is to evaluate the long term clinical and radiographic outcome and stability after transplantation of third molar with complete root formation. Methods: The subjects were 31 teeth (male 17, female 14, aged 22-55, average 39.9 yr old) of 31 patients who visited the department of periodontics and passed more than two years after autotransplantation procedure and still under regular check up. Modified success criteria of Chamberlin and Goerig was applied to determine the success of autotransplantation. Results: Three out of 31 teeth failed and resulted 90.3% of success rate. When compared according to sex, 15 out of 17 teeth had succeeded in male, 13 out of 14 succeeded in female. When compared the success rate according to cause of extraction, tooth loss due to caries and root fracture had all succeeded but 3 out of 24 had failed in tooth loss due to periodontal disease. When compared according to donor teeth, 12 out of 14 maxillary third molars and 16 out of 17 mandibular third molars had succeeded. Conclusions: In long term evaluation over two years, if appropriate surgical procedure and proper case selection is made, autotransplantation of the third molar with complete root formation can be the alternative choice that substitutes prosthetic or implant treatment and it is a functionally acceptable procedure.

Case report: Laminate prosthesis with orthodontic treatment for achieve anterior esthetics and functional occlusion (심미와 기능 회복을 위한 교정- 라미네이트 수복 치료 증례)

  • Lee, Han Na
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.80-85
    • /
    • 2014
  • Orthodontic treatment is obviously the first choice to get aligned teeth cause of conservative treatment. But it is impossible to get highly esthetic result only orthodontic treatment in case of peg lateralis, discrepancy tooth size, discolored teeth or fractured teeth. As all treatment does, especially in esthetic treatment it is always required interdisciplinary diagnosis and treatment plan; orthodontics, periodontology, prothetics, implant therapy. As also, the treatment should be maintained long-term treatment with stable and harmonious state by esthetic satisfaction and functional occlusion those who needs various dental care as interdisciplinary treatment. This case is the laminate treatment with the orthodontic treatment on 37 ages/ Female patient who has cross bite at anteriors and premolar area and abrasion on centralis at right maxilla. By orthodontic treatment aligned teeth positions, it makes functional occlusion. As laminate treatment with minimum teeth preparation is able to release anterior esthetics. Follow up check for 2 years has been performed since the final prosthetics delivery to the patient. No sign of relapse, fracture of laminate were detected.

Evisceration and Intrascleral Silicone Ball Prosthesis with Penetrating Keratoplasty on Perforated Corneal Ulcer Secondary to KCS in a Shih Tzu Dog (개의 건성각결막염에 의한 각막천공을 안구내용물적출술과 실리콘볼 삽입 후 각막이식을 적용하여 치료한 증례)

  • Kim, Jong Min;Kim, Jongyeol;Kim, Hwangmin;Jang, Se Wng;Jeong, In Seong;Choi, Seok Hwa
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.356-358
    • /
    • 2015
  • When severely large corneal perforation occurs, penetrating keratoplasty is a treatment of choice alternative to enucleation. A twelve-year-old male Shih Tzu was referred with perforated corneal ulcer secondary to keratoconjunctivitis sicca (KCS). Perforated cornea was directly sutured using 10-0 non-absorbable suture material, and rotational conjunctival flap was performed. However, re-perforation of cornea by wound dehiscence was observed at 1 month after operation. The yellowish lens escaped outside the orbit during corneal re-perforation, the diagnosis was re-perforated corneal ulcer, moderate corneal edema, moderate KCS (STT; 6 mm) and endophthalmitis caused by escaped lens outside orbit. Accordingly, penetrating keratoplasty (PK) and evisceration through corneal recipient site and intrascleral silicone ball prosthesis were carried out as the planned treatment, and resulted in good cosmetic improvement compared to enucliation. However, exposure of silicone ball occurred at the 9 months after the surgery due to the irritation of implant, thus enucleation was performed. In perforated large corneal ulcer with severe intraocular damage, evisceration with silicone ball insertion with PK would be alternative treatment choice to improve the cosmetic appearance.

THE MORPHOLOGICAL OBSERVATION OF HUMAN GINGIVAL FIBROBLASTS ATTACHMENT AND SPREADING ON THE MECHANICAL TREATED TITANIUM PLASMA SPRAYED IMPLANT SURFACE (기계적 표면 처리된 TITANIUM PLASMA SPRAYED IMPLANT에 대한 치은섬유아세포전개양상의 형태학적 관찰)

  • Whang, Yun-Hi;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.741-755
    • /
    • 1995
  • Currently titanium is the material of choice for implants because of its biological acceptance. This high degree of biocompatibility is thought to result, in part, from the protective and stable oxide layer that presumably aids in the bonding of the extracellular matrix at the implant-tissue interface. Endosseous dental implants are interfaced with bone, connective tissue, and epithelium when implanted into the jaw bone. The soft tissue interface including connective tissue and epithelium is one of the most critical factors in the determination of implant maintenance and prognosis. For maintenance of failing or failed implants, it is essential to treat the implant fixture surface to remove bacterial endotoxins and make a surface tolerated by surrounding soft and hard tissues. In this study, the effect of mechanical treatment on titanium plasma sprayed implant on adhesiveness and proliferation of human gingival fibroblasts and changed surface characteristics were studied. titanium plasma sprayed discs manufactured by Friedrichsfeld company were treated with loaw speed stone bur, a rubber point and a jetpolisher. Its surface components were analyzed with Energy dispersive X-ray spectroscopy to evaluate whether the surface characteristics were altered or not. To observe the spreading pattern of the human gingival fibroblasts which attached to the all specimens author used the scanning electron microscope. The results were as follows : Pure titanium and plasma sprayed titanium, stone polished titanium showed titanium peak and small amout of aluminum, so there was no alteration on surface characteristics. Under the scanning electron microscopic examination in the initial attachment of human gingival fibroblast, there was a slight enhancement in pure titanium, stone polished titanium than plasma sprayed titanium. After 6 hours, the pure titanium and stone polished titanium showed human gingival fibroblasts were elongated and connected with numerous processes. Human gingival fibroblasts were more intimately attached on the pure titanium discs than on the other discs. The human gingival fibroblasts attached on the plasma sprayed titanium by thin and elongated processes. After 24 hours, the human gingival fibroblasts connected with each other via numerous processes and compeletly covered the pure titanium and stone polshed titanium discs. Human gingival fibroblasts had multiple point contacts with more long and thin lamellopodia and showed a little bare surface on plasma sprayed titanium discs.

  • PDF