• Title/Summary/Keyword: impeller pump

Search Result 340, Processing Time 0.04 seconds

Performance Prediction of a Turbopump System (유동해석을 이용한 터보펌프 성능 예측)

  • Choe, Chang-Ho;Hong, Sun-Sam;Kim, Jin-Han;No, Jun-Gu;Kim, Dae-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.70-75
    • /
    • 2006
  • The performance of a turbopump system composed of an inducer, an impeller, a volute and seals has been computationally analyzed. To save the computational time, only one flow passage of the inducer and impeller is considered for the computations. A steady mixing-plane method is used on the impeller/volute interface for simulating the unsteady interaction phenomena. The axial thrust is predicted from the turbopump calculation in its entirety, which is necessary for such estimation. Moreover, the effects of each component on the pump performance are investigated at a design condition through the analysis of flow structures. The predicted performance is in good agreement with experimental data in terms of head rise, efficiency and volute wall pressure distributions despite of highly complex flow structures being present. The computational results also show that the axial and radial thrusts are within the design limit although corresponding experimental measurements were not taken.

Study on the Radial Diffuser of Multistage High Pressure Pump (고압 다단 펌프의 레이디얼 디퓨저에 대한 연구)

  • Kim, Deok Su;Mamatov, Sanjar;Park, Warn Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.11
    • /
    • pp.727-736
    • /
    • 2016
  • In this study, a high-pressure multistage pump used in the combined cycle power plants is analyzed. The pump performance characteristics (differential head and efficiency) are numerically analyzed for different shapes of the radial diffuser. The design variables selected for the radial diffuser are, number of vanes, diameter ratio ($D_4/D_3$), return channel outlet angle(${\alpha}_6$), and pressure recovery factor ($C_p$). The numerical analysis results showed that the differential head and efficiency are the highest when the diameter ratio is the highest. Further, it was observed that the differential head was lower when the return channel outlet angle was $60^{\circ}$ than when it was $90^{\circ}$, because of pre-swirl at the diffuser outlet.

A Study on the Pump System Design Optimization for Regional Water Supply Facilities (광역상수도용 펌프의 규격 최적결정방법에 관한 연구)

  • Roh, Hyung-woon;Suh, Sang-Ho;Kim, Kyung-Yup;Kim, Sung-Won;Kim, Il-Soo;Park, Jong-Moon;Park, HeeKyung;Park, No-Suk;Lee, Bong-Joo;Lee, Jeung-Woo;Lee, Young-Bum;Lee, Young-Ho;Kim, Sang-Gyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.159-164
    • /
    • 2001
  • An extensive range of pumping facilities are employed in the regional water supply system in metropolitan areas, and optimization and the systematic combination of the pump facilities have direct bearing on the stability and economy of the water supply system concerned. These systems must be able to guarantee stability, efficiency and offer high reliability. Preparation of metropolitan area regional water supply system construction project must include a basic plan which takes into account the suitability of pumping facilities to be used, the environment in which facilities will be installed, man-power requirements and basic operational and management policies. This paper contains over-all analysis of the management of metropolitan area regional water supply systems and highlights the cause of Inefficiency and energy waste and puts forward a remedial plan of action. In addition, pump/motor specification programs were developed using Visual Basic to assist selection of the same.

  • PDF

Experimental Investigation of the Development of a Rotor Type Slurry Pump (로터형 슬러리 펌프 개발을 위한 실험적 연구)

  • Park, Sang-Kyoo;Yun, Jae-Geun;Yangr, Hei-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.456-462
    • /
    • 2015
  • The objective of this study was to develop an advanced pump technology using tornado and axial pumping principles without priming water. The developed rotor type slurry pump consisted of an electric motor, driving shaft and coupling, a rotor, an impeller, suction and discharge pipes. For the clean water test, the experimental results are presented for the discharge flowrate, electric power input and vacuum pressure with the rotor design parameters as a function of the motor rpm. The slurry discharge characteristics with the solid concentration of the cement slurry was performed. As the rotor diameter and height increase, the discharge flowrate and electric power input increase while the vacuum pressure in the suction pipe decreases. The rotor thickness had no significant effect on the discharge flowrate and electric power input. Slurries with more than 18 % solid concentration, which is the development factor, can be pumped.

Cavitation in Pump Inducer with Axi-asymmetrical Inlet Plate Observed by Multi-cameras

  • Kim, Jun-Ho;Atono, Takashi;Ishizaka, Koichi;Watanabe, Satoshi;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.2
    • /
    • pp.122-128
    • /
    • 2010
  • The attachment of inducer in front of main impeller is a powerful method to improve cavitation performance; however, cavitation surge oscillation with low frequency occurs with blade cavity growing to each throat section of blade passage simultaneously. Then, one conceptual method of installing suction axi-asymmetrical plate has been proposed so as to keep every throat passage away from being unstable at once, and the effect on suppression of the oscillation were investigated. In the present study, cavitation behaviors in the inducer is observed with distributing multi-cameras circumferentially, recording simultaneously and reconstructing multi-photos on one plane field as moving a linear cascade. Observed results are utilized for discussion with other measuring results as casing wall pressure distribution. Then the suppression mechanism of oscillation by installing axi-asymmetrical inlet plate will be clarified in more details.

Fundamental Study on Cathodic Protection and Material Development as Erosion-Control Methods of Oceanic Centrifugal Pump(2) (해상용 원심펌프 임펠러의 침식억제법으로 음극방식 및 재료개발에 관한 기초연구(2))

  • Lee, Jin Yeol;Im, U Jo;O, In Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.92-92
    • /
    • 1996
  • Recently, with the rapid development in the oceanic systems such as the oceanic structures and vessel, there occurs much interest in the impingement erosion-corrosion. In this paper, Cu-metal was tested by using of erosion apparatus with water-jet type and was investigated under the behaviour of impingement erosion-corrosion according to various environmental conditions, and the properties of Cu-metal were evaluated through the measurement by weight loss, weight loss rate, protective efficiency. The results were compared with those obtained using Cu-metal applied to cathodic protection and Cu-alloys added to Zn or Al-metal. As a basis of those results, the best protective efficiencies could be taken as using cathodic protection method and Cu-alloy with Al & Zn material addings, and will be suggested as the fundamental data of the anti-impingement erosion-corrosion on Cu-metal of impeller material for oceanic centrifugal pump.

Fundamental Study on Cathodic Protection and Material Development as Erosion - Control Methods of Oceanic Centrifugal Pump(2) (해상용 원심펌프 임펠러의 침식억제법으로 음극방식 및 재료개발에 관한 기초연구 (2))

  • 이진열;임우조;오인호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.24-31
    • /
    • 1996
  • Recently, with the rapid development in the oceanic systems such as the oceanic structures and vessel, there occurs much interest in the impingement erosion-corrosion. In this paper, Cu-metal was tested by using of erosion apparatus with water-jet type and was investigated under the behaviour of impingement erosion-corrosion according to various environmental conditions, and the properties of Cu-metal were evaluated through the measurement by weight loss, weight loss rate, protective efficiency. The results were compared with those obtained using Cu-metal applied to cathodic protection and Cu-alloys added to Zn or Al-metal. As a basis of those results, the best protective efficiencies could be taken as using cathodic protection method and Cu-alloy with Al & Zn material addings, and will be suggested as the fundamental data of the anti-impingement erosion-corrosion on Cu-metal of impeller material for oceanic centrifugal pump.

  • PDF

Diagnostics of nuclear reactor coolant pump in transition process on performance and vortex dynamics under station blackout accident

  • Ye, Daoxing;Lai, Xide;Luo, Yimin;Liu, Anlin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2183-2195
    • /
    • 2020
  • A mathematical model for the flowrate and rotation speed of RCP during idling was established. The numerical calculation method and dimensionless method were used to analyze the flow, head, torque and pressure and speed changes under idle conditions. Regularity, using the Q criterion vortex identification judgment method combined with surface flow spectrum morphology analysis to diagnose the vortex dynamic characteristics on RCP blade. On impeller blade, there is two oscillations in the pressure ratio on pressure surface in blade outlet region. The velocity on the suction surface is two times more oscillating than the inlet of blade, and there is an intersection with the velocity ratio curve on pressure surface. On blade of guide vane, the pressure ratio increases along the inlet to outlet direction, and the speed ratio decreases with the increase of idle time. There is a vortex that rotates counterclockwise on the suction surface, and the streamline on the suction surface of blade is subjected to the entrainment and blocking action of the vortex creates a large reverse flow in the main flow region. There are two vortices at the outlet of guide vane suction side and the vortices are in opposite directions.

Cavitation Surge Suppression of Pump Inducer with Axi-asymmetrical Inlet Plate

  • Kim, Jun-Ho;Ishzaka, Koichi;Watanabe, Satoshi;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.1
    • /
    • pp.50-57
    • /
    • 2010
  • The attachment of inducer in front of main impeller is a powerful method to improve cavitation performance. Cavitation surge oscillation, however, often occurs at partial flow rate and extremely low suction pressure. As the cavitation surge oscillation with low frequency of about 10 Hz occurs in a close relation between the inlet backflow cavitation and the growth of blade cavity into the throat section of blade passage, one method of installing an axi-asymmetrical plate upstream of inducer has been proposed to suppress the oscillation. The inlet flow distortion due to the axi-asymmetrical plate makes different elongations of cavities on all blades, which prevent the flow from becoming simultaneously unstable at all throat sections. In the present study, changes of the suppression effects with the axial distance between the inducer inlet and the plate and the changes with the blockage ratios of plate area to the cross-sectional area of inducer inlet are investigated for helical inducers with tip blade angles of $8^{\circ}$ and $14^{\circ}$. Then a conceivable application will be proposed to suppress the cavitation surge oscillation by installing axi-asymmetrical inlet plate.

Study on the Decontamination of Primary Cooling Pump in HANARO (하나로 1차 냉각펌프 제염에 대한 고찰)

  • An Jung-Sug;Lee Kyung-Ho;Kim Kwang-Dug;Park Young-Chul
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.21-29
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Recently, ten years after the initial operation of the HANARO, one of the two primary cooling pumps was decontaminated for overhaul maintenance in 2004. Before decontamination exposure doserate and surface contamination level of primary cooling pump measured at 4 points. After final decontamination exposure doserate and surface contamination level of primary cooling pump remeasured by same method done before. It is easy to decontaminate the out side exposed surfaces of the pump, but it is difficult to approach the inside surface due to double volute installed in the casing. Therefore, a new decontamination facility has been developed to solve this problem. A concentrated de-contaminant (DX-300) is rotated in the closed pump casing by the impeller actuated by a temporary motor. Nuclide particles are removed by the emulsification effect of the de-contaminant and the surface contaminants are chemically removed from the pump by the corrosion and dissolution effect. The inside surfaces of the primary cooling pump have been decontaminated by using the facility. As results, the contamination level of the inside surfaces was maintained below the surface contamination limit.

  • PDF