• 제목/요약/키워드: impedance responses

검색결과 111건 처리시간 0.026초

PZT-고분자 3-3형 복합압전체 소자로 제작된 초음파 트랜스듀서의 펄스에코 응답특성 (Pulse-echo response of ultrasonic transducer fabricated with PZT-polymer 3-3 type composite)

  • 박정학;최헌일;손무현;사공건
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권10호
    • /
    • pp.1053-1059
    • /
    • 1996
  • The pulse-echo response of the piezoceramics PZT-polymer 3-3 type composite transducers with various PVA additions were investigated. The PZT powder was prepared by the molten salt synthesis method. The porous PZT specimens will be used as a filler to make 3-3 type comosite were prepared from a mixture of PZT and polyvinylalcohol(PVA) sphere by utilizing BURPS(Bumout Plastic Sphere) technique. It was shown that the transmitting and receiving sensitivity of 3-3 type piezoelectric composite transducers could be improved than that of solid PZT transducers. The reason is that 3-3 type piezoelectric composite have low dielectric constant, density and acoustic impedance. The distance between transducer and reflector was in good agreement with the distance calculated from the longitudinal velocity of the specimens and receiving time observed pulse-echo responses on the ultrasonic transducer analyzer.

  • PDF

Seismic attributes for characterization of a heavy-oil shaly-sand reservoir in the Muglad Basin of South Sudan

  • Deng, William A.;Kim, Taeyoun;Jang, Seonghyung
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.1027-1039
    • /
    • 2018
  • Seismic attributes are often used to identify lithology and evaluate reservoir properties. However, interpretation based only on structural attributes and without knowledge of the Vp/Vs ratio can limit the ability to evaluate changes in heavy oil reservoirs. These limitations are often due to less obvious impedance differences. In order to investigate pieces of evidence of a heavy-oil shaly-sand reservoir from seismic data, besides geochemistry, we studied seismic attributes and characterized the reservoir using seismic stack data and well logging data. The study area was the Muglad rift basin in South Sudan. We conducted a seismic complex analysis to evaluate the target reservoir. To delineate the frequency responses of the different lithological units, we applied the spectral decomposition method to the target reservoir. The most unexpected result was continuous bands of strong seismic reflectors in the target reservoir, which extended across the borehole. Spectral decomposition analysis showed that the low-frequency zone of 25 Hz dominant frequency was consistent with instantaneous attributes. This approach can identify lithology, reveal frequency anomalies, and filter the stacked section into low- and high-frequency bands. The heavy-oil reservoir zones exhibited velocity attenuation and the amplitude was strongly frequency dependent.

Preparation of Pseudotetragonal $ZrO_{0.75}S$ and Its Electric Responses on Temperature and Frequency Related to Microstructural Relaxation

  • 로영아;김성진;이유경;김자형
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권11호
    • /
    • pp.1231-1235
    • /
    • 2001
  • Pseudotetragonal ZrO0.75S whose space group is P212121 was synthesized and the cell dimensions were a=5.110(2) $\AA$, b=5.110(7) $\AA$, and c=5.198(8) $\AA.$ The space group P212121 seems to be resulted from lowering the symmetry of cubic ZrOS structure with P213 space group by lattice distortion due to the oxygen defects. In the distorted structure, bond shortening between metal-nonmetal by reduction of cell volume and alternation of Zr-Zr distance were observed. Dielectric constant and loss data of the bulk material in temperature range -170 to 20 $^{\circ}C$ and frequency range 50 Hz to 1 MHz showed that there was dielectric transition at around -70 $^{\circ}C$ originated from the relaxation of Zr-S segment. Comparing with ZrO2 exhibited the dielectirc constants, 9.0 at room temperature, ZrO0.75S showed high dielectric constant, k = 200.2 at 100 kHz. The activation energy of relaxation time due to dielectric relaxation of Zr-S was 0.47 eV (11.3 kcal/mole). According to the impedance spectra, ZrO0.75S showed more parallel circuit character between the resistance and capacitance components at the temperature (-70 $^{\circ}C)$ that the Zr-S dielectric relaxation was observed.

복합평판구조물의 고주파수 대역 유체/구조 연성 소음진동예측을 위한 에너지흐름유한요소해석 (Energy Flow Finite Element Analysis for High Frequency Acoustic and Vibrational Prediction of Complicated Plate Structures Considering Fluid-Structure Interaction)

  • 윤태흠;박영호
    • 대한조선학회논문집
    • /
    • 제60권1호
    • /
    • pp.20-30
    • /
    • 2023
  • In this paper, the Energy Flow Finite Element Analysis (EFFEA) was performed to predict the acoustic and vibrational responses of complicated plate structures considering improved Fluid-Structure Interaction (FSI). For this, a new power transfer relationship was derived at the area junction where two different fluids are in contact on both sides of the plate. In order to increase the reliability of EFFEA of complicated plate structures immersed in a high-density fluid, the corrected flexural wavenumber and group velocity considering fluid-loading effect were derived. As the specific acoustic impedance of the fluid in contact with the plate increases, the flexural wavenumber of the plate increases. As a result, the flexural group velocity is reduced, and the spatial damping effect of the flexural energy density is increased. Additionally, for the EFFEA of arbitary-shaped built-up structures, the energy flow finite element formulation for the acoustic tetrahedral element was newly performed. Finally, for validation of the derived theory and developed software, numerical applications of complicated plate structures submerged in seawater or air were successfully performed.

MT 자료 역산과정에서 반복적인 Tensor Stripping을 통한 해양효과 보정 (Correction of the Sea Effect in the Magnetotelluric (MT) Data Using an Iterative Tensor Stripping During Inversion)

  • 양준모;이춘기;유해수
    • 지구물리와물리탐사
    • /
    • 제11권4호
    • /
    • pp.286-301
    • /
    • 2008
  • 해양과 인접한 지역에서 MT탐사 자료를 해석하는 경우, 해양은 심부 구조의 반응을 왜곡시키는 역할을 한다. 본 연구에서는 해저면 MT탐사에서 해저 지형의 영향을 제거하는 지형보정 기법을 바탕으로, 반복적으로 해양효과를 보정하는 기법을 개발하였다. 제안된 기법은 우선 관측 MT 반응에서 주변 해양의 영향을 보정하고, 그 후 해양이 없는 모델공간에서 역산을 수행한다. 주변 해양과 지하구조와의 상호결합 때문에 이 과정은 반복적으로 수행되며, 보정 결과의 변화가 미미할 때 반복과정이 종료된다. 제안된 기법의 검증을 위해 해양을 포함하는 3차원 순산 모델링을 통하여 합성 자료를 생성하였고, 1차원 및 2차원 구조에서 보정기법을 적용하였다. 대체적으로 제안된 해양효과 보정 기법은 $2{\sim}3$회의 반복단계를 거친 후 해양이 없는 경우의 지하구조를 성공적으로 복원하였다. 실제 MT 자료와 유사한 자료를 획득하기 위해 1차원 구조로 잘 알려져 있는 제주도에 대한 3차원 모델링을 수행하여 유사 현장 자료를 생성하였다. 제주도 모델의 경우, 해양효과는 약 1 Hz 이하에서 나타나기 시작하였으며 측선의 위치 때문에 해안선과 수직한 전기장 성분에서 상대 적으로 왜곡이 심하게 나타났다. 이러한 왜곡은 3회의 해양효과 보정과정을 통해 성공적으로 제거되었으며, 1차원 및 2 차원 역산은 모델링 시 가정한 제주도의 지하구조를 성공적으로 복원하였다.

Electrical Characterization of Ultrathin Film Electrolytes for Micro-SOFCs

  • Shin, Eui-Chol;Ahn, Pyung-An;Jo, Jung-Mo;Noh, Ho-Sung;Hwang, Jaeyeon;Lee, Jong-Ho;Son, Ji-Won;Lee, Jong-Sook
    • 한국세라믹학회지
    • /
    • 제49권5호
    • /
    • pp.404-411
    • /
    • 2012
  • The reliability of solid oxide fuel cells (SOFCs) particularly depends on the high quality of solid oxide electrolytes. The application of thinner electrolytes and multi electrolyte layers requires a more reliable characterization method. Most of the investigations on thin film solid electrolytes have been made for the parallel transport along the interface, which is not however directly related to the fuel cell performance of those electrolytes. In this work an array of ion-blocking metallic Ti/Au microelectrodes with about a $160{\mu}m$ diameter was applied on top of an ultrathin ($1{\mu}m$) yttria-stabilized-zirconia/gadolinium-doped-ceria (YSZ/GDC) heterolayer solid electrolyte in a micro-SOFC prepared by PLD as well as an 8-${\mu}m$ thick YSZ layer by screen printing, to study the transport characteristics in the perpendicular direction relevant for fuel cell operation. While the capacitance variation in the electrode area supported the working principle of the measurement technique, other local variations could be related to the quality of the electrolyte layers and deposited electrode points. While the small electrode size and low temperature measurements increaseed the electrolyte resistances enough for the reliable estimation, the impedance spectra appeared to consist of only a large electrode polarization. Modulus representation distinguished two high frequency responses with resistance magnitude differing by orders of magnitude, which can be ascribed to the gadolinium-doped ceria buffer electrolyte layer with a 200 nm thickness and yttria-stabilized zirconia layer of about $1{\mu}m$. The major impedance response was attributed to the resistance due to electron hole conduction in GDC due to the ion-blocking top electrodes with activation energy of 0.7 eV. The respective conductivity values were obtained by model analysis using empirical Havriliak-Negami elements and by temperature adjustments with respect to the conductivity of the YSZ layers.

중저온형 SOFC를 위한 PSCF3737(Pr0.3Sr0.7Co0.3Fe0.7O3) 공기극 물질의 특성 및 최적화께 관한 연구 (Study of Optimization and Characteristics of PSCF3737(Pr0.3Sr0.7Co0.3Fe0.7O3) for IT-SOFC)

  • 박광진;이창보;김정현;백승욱;배중면
    • 전기화학회지
    • /
    • 제10권3호
    • /
    • pp.207-212
    • /
    • 2007
  • IT-SOFC(중저온형 고체산화물 연료전지)의 공기극으로 적합한 PSCF3737의 물질 특성을 파악하고 그 특성을 이용하여 낮은 ASR을 갖기 위한 소결 온도 및 두께 최적화에 관한 연구를 수행하였다. 분말 사이즈 및 상형성을 고려할 때 GNP 방법으로 합성된 분말의 하소 온도는 $1000^{\circ}C$가 적합함을 알 수 있었다. 산소 분압에 따른 ASR 변화 실험을 통하여 PSCF3737의 저항 성분을 전극 자체의 특성과 관련된 중간 주파수 대역(${\sim}10^2Hz$)과 산소의 확산에 영향 받는 낮은 주파수 대역(${\sim}10^{-1}Hz$) 2가지로 분류할 수 있었다. 공기극의 특성 실험을 통하여 소결 온도는 $1200^{\circ}C$가 가장 적합하며 공기극의 두께는 2번 스크린 프린팅 된 $27\;{\mu}m$가 가장 적합함을 알 수 있었다. 이를 토대로 EIS 측정을 하면 $700^{\circ}C$에서 $0.115\;{\Omega}cm^2$의 낮은 ASR값을 얻을 수 있었다.

진동수 영역에서 기기-구조물 상호작용을 고려한 층응답스펙트럼의 작성 (Generation of Floor Response Spectra including Equipment-Structure Interaction in Frequency Domain)

  • 최동호;이상훈
    • 한국지진공학회논문집
    • /
    • 제9권6호
    • /
    • pp.13-19
    • /
    • 2005
  • 원자력발전소의 기기, 배관 시스템과 같은 부속구조물의 동적 응답을 먼기 위해 사용되는 층응답스펙트럼은 일반적으로 주구조물과 부속구조물의 동적 상호작용이 반영되지 않고 만들어진다. 본 연구에서는 기기와 구조물의 동적 상호작용이 고려된 해석을 통해 층응답스펙트럼을 생성시키는 해석법을 기술하였다. 이 방법은 기기를 모사하는 단자유도계와 기기가 놓여있는 구조물의 임피던스로 분할되는 부분구조 해석법을 적용하여 기기의 응답을 구한다. 단자유도계의 진동수, 감쇠비 및 질량 특성을 변화시키면서 최대 동적 응답을 계산함으로써 일련의 층응답스펙트럼을 작성한다. 전형적인 원자력발전소의 원자로 구조물에서 본 방법을 고려한 층응답스펙트럼과 기기를 포함한 전체 해석으로부터 작성된 층응답스펙트럼과 비교함으로써 본 연구의 타당성을 확인하였다. 기기-구조물 상호작용 효과를 확인하기 위하여 구조물 질량의 1% 이내인 기기에 대하여 기술된 방법과 기존 방법을 각각 적용하여 최대 응답값을 비교하였다. 그 결과 지배 진동수 부근에서 기기-구조물 상호작용을 고려한 응답이 그렇지 않은 경우인 기존방법의 응답에 비하여 저감되는 현상을 보였다.

서열환경하에서 체지방률에 따른 오전과 오후의 체온조절반응 (Thermoregulatory Responses of AM & PM with Body Fat Rate at a Hot Environment)

  • 김성숙;이정숙;김희은
    • 한국의류산업학회지
    • /
    • 제7권3호
    • /
    • pp.315-320
    • /
    • 2005
  • With regard to the fact that temperature of human body remains almost constant at $37^{\circ}C$, changes by circadian variation, this study intended to investigate the effect of circadian rhythm on physiological responses of human body according to body fat rate. Fifteen healthy adult women were recruited for this study and were measured body fat as a method of bio impedance. We organized subjects into three groups ; low body fat group(group L-less than 20% of body fat), medium body fat group(group M-20%~30% of body fat) and high body fat group(group H-more than 30% of body fat). The experiment was carried out in a climate chamber of $32^{\circ}C$, 60% RH with the repeat of 'Exercise' and 'Rest' period. Subjects participated in two experiments, one is morning experiment(called 'AM'), the other is afternoon experiment (called 'PM'). The results of this study are as follows ; As to the variation of rectal temperature, group L and M had a significant difference in the time of the day between AM and PM, but group H had almost the same rectal temperature in the two kinds of experimental time. The reason why group H had a smaller difference in the circadian rhythm of rectal temperature in this study is estimated at the Budd et al.(1991)'s results that body fat had effects on reduction in thermogenesis, radiation, mean skin temperature, and increase in insulation of the tissues. Group M had the highest mean skin temperature in the 'PM'. All the 3 groups didn't have stable values in 'AM'. But it showed more stable in 'PM' than 'AM'. Sweat rate was the highest in group H in both 'AM' and 'PM'. Group M had larger sweat rate in 'PM' than 'AM'. but in group L and H, sweat rate was almost the same in two kinds of time of the day. This result suggests that who have more or less body fat have larger difference in sweat rate between morning and afternoon than who have normal body fat.

적분방정식을 이용한 3차원 지자기 지전류 모델링 (Three-Dimensional Magnetotelluric Modeling Using Integral Equations)

  • 김희준;이동성
    • 자원환경지질
    • /
    • 제27권2호
    • /
    • pp.191-199
    • /
    • 1994
  • 층상대지속에 있는 3차원 물체에 의한 지자기 지전류 (MT)응답을 계산하기 위하여 적분방정식을 이용한 수치모델링법을 개발하였다. 이 방법에서는 3차원 이상체를 몇 개의 세포로 분할하여 펄스기조함수로 근사할 수 있는 전류분포로 치환한다. 층상대지를 표현하는 전기 텐서그린함수를 쓰면 행렬방정식을 유도할 수 있으며 이를 각 세포의 벡터전류에 대하여 푼다. 결국 미지의 산란장은 산란전류에 관한 전기 및 자기 텐서그린함수를 적분함으로써 얻어진다. 지표면 근처에 3차원 전도성물체가 존재할 때 2차원의 TE모드 모델링으로는 깊은 곳에 가짜의 저 비저항을 가정해야 한다. 이는 TE모드 모델링에서는 경계면 전하의 영향을 고려할 수 없기 때문이다. 그러나 긴 3차원 직방체의 가운데를 가로지르는 단연은 2차원 TM모드 아르고리즘으로 정확히 모델화할 수 있으며, 이는 정식화과정에서 경계면 전하가 고려되어 있기 때문이다. 다중 주파수에 관한 수치계산 결과 겉보기 비저항과 위상은 상호보완적인 변수라는 것이 밝혀졌다. 따라서 이들 변수는 주파수영역 MT 해석시 함께 취급되는 것이 바람직하다.

  • PDF