• Title/Summary/Keyword: impedance measurement tool

Search Result 23, Processing Time 0.023 seconds

New Techniques for Impedance Characteristics Measurement of Islanded Microgrid based on Stability Analysis

  • Hou, Lixiang;Zhuo, Fang;Shi, Hongtao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1163-1175
    • /
    • 2016
  • In recent years, microgrids have been the focus of considerable attention in distributed energy distribution. Microgrids contain a large number of power electronic devices that can potentially cause negative impedance instability. Harmonic impedance is an important tool to analyze stability and power quality of microgrids. Harmonic impedance can also be used in harmonic source localization. Precise measurement of microgrid impedance and analysis of system stability with impedances are essential to increase stability. In this study, we introduce a new square wave current injection method for impedance measurement and stability analysis. First, three stability criteria based on impedance parameters are presented. Then, we present a new impedance measurement method for microgrids based on square wave current injection. By injecting an unbalanced line-to-line current between two lines of the AC system, the method determines all impedance information in the traditional synchronous reference frame d-q model. Finally, the microgrid impedances of each part and the overall microgrid are calculated to verify the measurement results. In the experiments, a simulation model of a three-phase AC microgrid is developed using PSCAD, and the AC system harmonic impedance measuring device is developed.

The Controlled Impedance Measurement on the PCB

  • Park, Min-Ju;Lee, Jae-Kyung;Yoon, Dal-Hwan;Min, Seung-Gi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.113-117
    • /
    • 2003
  • The digital systems include the noise in power supply, ground and packaging due to a simultaneous switching of signal, signal reflections and distortions on single and multiple transmission lines. The requirement for the controlled impedance on a PCB can be both a critical success factor and a design challenge. So, the invented tool simulates the tracks controlled impedance with the test coupon. It can saves the design time and supports the economical PCB design.

  • PDF

Development of Pneumography Impedance Based Respiration Measurement System Using Kalman Filter (칼만 필터를 이용한 흉곽 임피던스법 기반의 호흡 신호 계측시스템 개발)

  • Nam, Eun-Hye;Choi, Chang-Hyun;Kim, Yong-Joo;Shin, Dong-Ryeol
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.326-332
    • /
    • 2008
  • A respiration measurement system for vital signs was developed. Respiration signals were measured, processed, and analyzed. Four electrodes, attached on the surface of the skin, were used to monitor respiration signals by impedance pneumography. The measured signals were amplified, detrended, filtered, and transferred toan embedded module. The Kalman filter was used to remove motion artifact from the respiration signals. Experiments were conducted at stable condition and walking condition to evaluate the performance of the system. Respiration rates of five males and five females were measured and analyzed at each condition. The referenced respiration signal was determined by temperature of nose surroundings. The results showed that the respiration rates at the walking condition had more motion artifacts than the stable condition. The accuracies of the respiration measurement system with Kalman filter were found as 96% at the stable condition and 95% at the walking condition. The results showed that the Kalman filter was an effective tool to remove the motion artifact from the respiration signal.

Solid medium integrated impedimetric biosensor for detection of microorganisms (미생물 검침을 위한 고체 배지 임피던스 센서)

  • Choi, Ah-Mi;Park, Jae-Sung;Jung, Hyo-Il
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1629-1632
    • /
    • 2008
  • Rapid, real-time detection of pathogenic microorganisms is an emerging and quickly evolving field of research, especially with regard to microorganisms that pose a major threat to public health. Herein, a new method that uses bioimpedance and solid culture medium for the real-time detection of microorganisms is introduced. We fabricated a new impedimetric biosensor by integrating solid media and two plane electrodes attached on two facing sides of an acryl well. During bioelectrical impedance analysis, the solid medium showed the characteristics of a homogenous conductive material. In a real-time impedance measurement, our solid-medium biosensor could monitor bacterial growth in situ with a detection time of ${\sim}4$ hrs. Our data indicate that the solid-medium biosensor is useful for detecting airborne microorganisms, thereby providing a new analytical tool for impedance microbiology.

  • PDF

Implementation of Multi-layer PCB Design Simulator for Controlled Impedance (제어된 임피던스용 다층 PCB 설계 시뮬레이터 구현)

  • Yoon, Dal-Hwan;Cho, Myun-Gyun;Lin, Chi-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.12
    • /
    • pp.73-81
    • /
    • 2011
  • As high speed digital systems continue to use components with faster edge rate and clock speeds, transmission of the digital information, it can bring about many troubles. The increasing requirement for controlled impedance PCBs becomes both a critical success factor and a design challenge to implement a system. Especially, the noise sources in high frequency digital systems include the noise in power supply, ground and packaging, and they destroy the fidelity of signals. Therefore PCB design with impendence matching is needed to improve fidelity of signal in H/W. In this paper, we have developed an impedance control and analysis tool for multi-layer PCB design, and simulates the tracks controlled impedance with the test coupon. So, it can save the design time and support the economical PCB design.

A monitoring apparatus for pulse shape of human heartbeats by magnetic impedance sensors (자기 임피던스 센서를 이용한 맥박 측정 장치)

  • Kim, Cheong-Worl;Gu, Bon-Ju;Kim, Jong-Seong
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • A monitoring apparatus for pulse shapes of human heartbeats has been developed using an amorphous MI(Magnetic Impedance) sensor. The pulse shapes are successfully obtained from voltage signals due to the variations of magnetic impedance in the amorphous MI sensor, which is attached to a patient's wrist. This voltage signal was fed into a signal processing module to extract the pulse shapes of heartbeats. The signal processing module, which is proposed to detect a weak variations of impedance in MI sensor under a noisy measurement environment, consists of a high frequency current source, an amplifier stage and a synchronous detection circuit. To evaluate the characteristics of a newly developed apparatus, various experiments were performed. The experimental results show that the developed apparatus could be used as a diagnosis tool for traditional Korean medicine with further systematic clinical studies.

Development of the Measurement Tool and Impedance Test Method for the Signal fidelity in PCB Tracks (PCB 트랙의 신호충실성을 위한 임피던스 계산 방법 및 측정 툴 개발)

  • 라광열;유재현;김철기;이재경;남지현;윤달환
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.51-54
    • /
    • 2002
  • As digital systems continue to use components with faster edge rate and clock speeds, transmission of the digital information can take place many troubles. The increasing requirement for controlled impedance PCBs becomes both a critical success factor and a design challenge. Especially, the noise sources in digital system include the noise in power supply, ground and packaging due to simultaneous switching of signal, signal reflections and distortions on single and multiple transmission lines. This paper simulates the tracks controlled impedance with the test coupon. So, it can saves the design time and supports the economical PCB design.

  • PDF

Novel Impedance Method for Analyzing Truncal Obesity (중심성 비만 분석을 위한 새로운 임피던스 해석법)

  • Lim, Taek-Gyun;Seo, Kwang-Seok;Jeong, In-Cheol;Jun, Suk-Hwan;Noh, Yeon-Sik;Kim, Eung-Seok;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.849-856
    • /
    • 2009
  • Truncal obesity associated with insulin resistance and metabolic syndrome increase the likelihood of hypertension, various cardiovascular diseases, hyperlipidemia and coronary heart diseases. International Diabetes Federation (IDF) experts recognized that it is necessary to develop the simple diagnostic tool which is applicable to diagnose truncal obesity worldwide, and proposed the method using a waist circumference but there is a limit to estimate subcutaneous fat distribution. However, waist line is also influenced by total fat capacity less than the intra abdominal fat. The more having severe obesity, the more correlation coefficient between waist line and intra abdominal fat is low. Therefore, this thesis defines a new abdominal impedance measurement position and impedance-index to analysis central obesity. This proposes the new model to estimate abdominal obesity using the abdominal impedance-index and CT images acquired fro 160 Korean subjects. The proposed model shows that the abdominal fat distribution has a higher correlation than waist line. (Adj R2=0.809, 0.667 and 0.687 with abdominal fat area, visceral fat area and subcutaneous fat area respectively).

Adaptor for Impedance measurement of plasma chamber (플라즈마 챔버 임피던스 측정용 Adaptor 개발)

  • 이의용;박성진;설용태
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.247-249
    • /
    • 2003
  • 본 연구에서는 RF 전력을 사용하는 플라즈마 식각/증착 장비에서의 플라즈마 챔버 내의 임피던스를 정확하게 측정하기 위한 Adaptor를 개발하였다. 개발된 Adaptor는 RF Matcher와 결합되며 RS-232 통신포트를 통하여 PC와 연결하여 챔버내의 임피던스 변화를 스미스 차트로 표시하여 실시간 관측이 가능하다. 이러한 Tool을 이용하여 수집된 데이터는 최적의 공정조건 구축에 활용이 가능하며 반도체 생산 라인에서의 생산성 향상에 기여할 수 있다.

  • PDF

A Characteristics of Impedance Propagation by the Unsteady Flow in a Hydraulic Pipeline (유압관로의 비정상유동에 따른 임피던스 전달특성)

  • Mo Yang-Woo;Yoo Young-Tae;Na Gee-Dae;Kim Ji-Hwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.48-55
    • /
    • 2004
  • Design for quite operation of fluid power system requires the understanding of noise and vibration characteristics of the system. This paper presents a dynamic response of design of hydraulic circuit. Experimental investigations on the attenuation of pressure ripple in automotive power steering hydraulic pipe line is examined. Also, a mathematical model of hydraulic pipe is p개posed to support a design of the hydraulic circuit. and the impedance characteristics of pressure ripple is analyzed. It is experimentally shown that power steering hydraulic pipe attenuates pressure ripple with high frequency.