• Title/Summary/Keyword: impedance(Z)

Search Result 189, Processing Time 0.031 seconds

Impedance Properties of Phase-Pure Titanium Dioxide Ceramics Sintered at Different Temperatures

  • Cui, Liqi;Niu, Ruifeng;Wang, Weitian
    • Korean Journal of Materials Research
    • /
    • v.32 no.4
    • /
    • pp.181-185
    • /
    • 2022
  • In this study, phase-pure titanium dioxide TiO2 ceramics are sintered using standard high-temperature solid-state reaction technique at different temperatures (1,000, 1,100, 1,200, 1,300, 1,400 ℃). The effect of sintering temperature on the densification and impedance properties of TiO2 ceramics is investigated. The bulk density and average grain size increase with the increase of sintering temperature. Impedance spectroscopy analysis (complex impedance Z* and complex modulus M*), performed in a broad frequency range from 100 Hz to 10 MHz, indicates that the TiO2 ceramics are dielectrically heterogeneous, consisting of grains and grain boundaries. The complex impedance Z* -plane indicates the resistance of grains of the TiO2 ceramics increases with increasing sintering temperature, while that of grain boundaries develops in the opposing direction. The complex modulus M*-plane shows a grain capacitance that seems to be independent of the sintering temperature, while that of the grain boundaries decreases with increasing sintering temperature. These results suggest that different sintering temperatures have effects on the microstructure, leading to changes in the impedance properties of TiO2 ceramics.

Microstrip Filter by Means of Hi-Z Low-Z Having Short Length Transmission Lines (짧은 길이 전송선로를 가지는 Hi-Z Low-Z에 의한 마이크로스트립 필터)

  • 이봉수;이사원
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.3
    • /
    • pp.107-112
    • /
    • 1998
  • In this paper, filter designed and produced to use hi-Z low-Z filter which is easy to produce microstrip line and uses space less than used stub filter. This filter has very short electrical length of lines, that is Bl<$\pi$/4, lowpass prototype series inductor replaced high impedance line section and shunt capacitance replaced low impedance line section. Replaced each section designed microstrip lines and effective permittivity of the given microstrip calculated and each section width and length calculated dna filter used design. Designed filter compared the theory value of touchstone with the experiment value of real produced filter and an analyzed response charictristic.

  • PDF

초광대역전송선형 FM 변별기에 관한 연구

  • 이충웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.2 no.1
    • /
    • pp.10-13
    • /
    • 1965
  • 본논문은 단종된 전송선과 개방된 전송선 및 2개의 결합저항기로 구성된 초광대역전송선형 FM변별기의 동적인 해석(dynamic analysis)을 취급하였다. 변별기의 출력파형의 Harmonic Distortion과 입력신호의 최대허용주파수변위와의 제관계를 Fourier transfrom으로 상세하게 해석하였다. 결합저항계수r(Fig 1 참조)는 변별기의 감도와 입력신호의 전주파수변위에 걸쳐 입력 Impedance가 일정하다는 견지에서 일로 놓아야 된다는 것이 판명되었다. 이론상으로는 100%의 주파수변위를 가진 FM신호라도 본변별기로 불과 2.6% Harmonic distortion으로 검파할 수 있으며 또한 검파시에 변별기의 입력 Impedance는 전종선의 특성 Impedance Z0로 일정하게 유지된다. 이론적인 결과를 뒷받침하기 위하여 실험결과를 첨부하였다. 본실험에서는 변별기의 특성곡선이 중심주파수 85.5Mc를 중심으로 40%의 주파수변위에 대하여 Linear하며, 또한 이때의 변별기의 입력 Impedance의 변화율은 이상치 Z0의 ±14% 이내이다.

  • PDF

Charicteristics of Stationary and Transient Ground Impedance of Large-Scale Grounding Piles (임펄스 전류에 대한 대규모 접지시스템의 정상상태 및 과도상태의 접지임피던스 특성)

  • Lee, B.H.;Lee, S.C.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2296-2298
    • /
    • 1999
  • The stationary ground resistance and the transient ground impedance of grounding system are very important parameters in the field of lightning and surge protection. But, it is very difficult to obtain correct values of them in large-scale grounding system. In this paper, the stationary and transient ground impedances of a large-scale grounding system have been measured and analyzed under impulse currents. In order to obtain correct values of them, we have described Z-v(impedance vs ground potential rise) distributions and Z-t waveforms. The transient ground impedance of 36 [m] long three-parallel grounding piles have showed the inductive aspects and the hysterisis region under impulse currents.

  • PDF

Designing Impedance Network at Quasi Z-Source Inverters by Considering ESR in the Capacitor (커패시터의 ESR을 고려한 Quasi Z-소스 인버터의 임피던스 네트워크 설계)

  • Yang, Jong-Ho;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.453-460
    • /
    • 2012
  • This paper proposes the method to design the parameters of an impedance network at three-phase QZSI(quasi Z-source inverter) by considering an equivalent series resistance (ESR) in the capacitor. The equations of both two capacitor voltages and two inductor currents are derived at three operating modes of the QZSI. The capacitor voltage ripples caused by the ESR in the capacitor at the transition state of operating modes are calculated. Based on the ripples of both the capacitor voltages and inductor currents, the optimal values of capacitor and inductor are designed. The simulation studies using PSIM and experimental results with DSP are carried out to verify the performance of design method.

Characteristics of Transient Grounding Impedance under Surge Currents (서지전류에 대한 과도접지임피던스의 특성)

  • Lee, Deok-Hui;Park, Jong-Sun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.11
    • /
    • pp.717-723
    • /
    • 1999
  • The transient characteristics of grounding systems play a major role in the protection of power equipments, electronic circuits and info-communication facilities against surges which arise from lightning or ground faults. Electronic devices are very weak against lightning surges injected from grounding systems and can be damaged. The malfunction and damage of electronic circuits bring about bad operation performances, a lot of economical losses, and etc. Therefore, in order to obtain the effective protection measure of electronic devices from overvoltages and lightning surges, the analysis of the transient grounding impedances in essential. One of this work is to examine the transient behaviors of grounding impedances under steplike currents for various grounding systems. And the other of this work is to evaluate the transient behaviors of a grid with rods under impulse currents and to investigate the effect of grounding lead wire. Transient grounding impedances of a grid with rods under impulse current waves have been measured as a parameter of the length of the grounding leads. Z-t, Z-i and V-i curves of transient grounding impedance under impulse current waveforms have been measured and analyzed. It was found that the grounding impedance gives the inductive, resistive and capacitive aspects under steplike current. Transient grounding impedance characteristics were very different with shapes, geometries of ground electrodes. Also, they were dependent on the waveform and magnitude of impulse current.

  • PDF

Studies on the fabrication of transmission line with high and low $Z_0$ using BCB layer (BCB를 이용한 High & Low$Z_0$전송선로 제작에 대한 연구)

  • 한효종;이성대;전영훈;윤관기;김삼동;황인석;이진구;류기현
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.57-60
    • /
    • 2002
  • In this paper, transmission lines with low and high characteristic impedance (Z$_{0}$) are fabricated and analyzed. The transmission lines are fabricated on the benzo-cyclo-butene (BCB) films of a low dielectric constant. For the low Z$_{0}$, two types of coplanar waveguide (CPW) structures are fabricated, which include bottom-ground and double-ground type. Measurement shows that Z$_{0}$ values for each CPW type are 7.3 and 9.4$\Omega$, respectively, at a signal line width of 100 #m. Whit the ratio between the spacing of bottom-ground and the signal line with becomes greater than 2.5, the Z$_{0}$ is nearly saturated. In addition, thin film microstrip lines fabricated using the BCB insertion layers show very low Z$_{0}$ of 25.5$\Omega$, and this impedance is ~64 % of the values obtained from the BCB-based CPW structures of the same line width. Measurement result of CPW on BCB layer is 100.5 Ω.s 100.5 Ω.

  • PDF

Contingency Ranking Algorithm Using Voltage Stability (전압안정성를 고려한 전력계통의 상정사고 선택 앨고리즘)

  • Park, Kyu-Hong;Cho, Yang-Haeng;Jung, Leen-Hark
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.105-107
    • /
    • 2002
  • This paper presents a algorithm for contingency ranking using the real power ratio. The fundamemtal cause of voltage collapse is considered due to excessive power trnsfer through the line. To obtain contingency ranking, maximum real power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. This algorithm is verified by simulation on a 6-bus test system.

  • PDF

Contingency Ranking Algorithm Using Voltage Stability (전압안정성를 고려한 전력계통의 상정사고 선택 엘고리즘)

  • Park, Kyu-Hong;Cho, Yang-Haeng;Jung, Ieen-Hark
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.146-148
    • /
    • 2002
  • This paper presents a algorithm for contingency ranking using the real power ratio, The fundamemtal cause of voltage collapse is considered due to excessive power trnsfer through the line To obtain contingency ranking, maximum real power tansferred to the load is obtained when load $impedance^{Z_r}$ equal to line $impedance^{Z_s}$, This algorithm is verified by simulation on a 6-bus test system.

  • PDF

Contigency Ranking Technique Using Line Capacity Calculation Method (선로용량 산정법을 이용한 상정사고 선택)

  • Park, Kyu-Hong;Jung, Jai-Kil;Hyun, Seung-Bum;Lee, In-Yong;Jung, In-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.285-288
    • /
    • 2000
  • This paper presents a technique for contingency ranting using line capacity calculation method and outage distribution factors(LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranting, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. ( $Z_r$/ $Z_s$=1) The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF