• Title/Summary/Keyword: impact transient response

Search Result 65, Processing Time 0.031 seconds

A Study on the Structure for the Improvement of Vibration Characteristics of a Vehicle Seatbelt (자동차 시트벨트의 진동특성 개선을 위한 구조에 관한 연구)

  • Kim, Chang-Hee;Oh, Chea-Eun;Kim, Tea-Woo;Song, Chul-Woo;Lee, Seok-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.97-102
    • /
    • 2020
  • To prevent vibration of a vehicle's interior parts due to external impacts, the vehicle should be designed to reduce vibration and increase rigidity. In this paper, we conducted a vehicle test in which the vibration characteristics of a seatbelt resulting from the impact of a person closing a car door were measured and analyzed. A correlation analysis was performed using the finite analysis method. Based on this, a sensitivity analysis was performed, and an improved model was designed. We compared the natural frequencies and mode shapes of the improved and the initial models, which confirmed that the natural frequency of the improved model was more than 10 Hz higher than that of the initial model. Moreover, the response frequency of the improved model was three times higher than the input frequency applied in the vehicle test.

INTEGRITY ANALYSIS OF AN UPPER GUIDE STRUCTURE FLANGE

  • LEE, KI-HYOUNG;KANG, SUNG-SIK;JHUNG, MYUNG JO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.766-775
    • /
    • 2015
  • The integrity assessment of reactor vessel internals should be conducted in the design process to secure the safety of nuclear power plants. Various loads such as self-weight, seismic load, flow-induced load, and preload are applied to the internals. Therefore, the American Society of Mechanical Engineers (ASME) Code, Section III, defines the stress limit for reactor vessel internals. The present study focused on structural response analyses of the upper guide structure upper flange. The distributions of the stress intensity in the flange body were analyzed under various design load cases during normal operation. The allowable stress intensities along the expected sections of stress concentration were derived from the results of the finite element analysis for evaluating the structural integrity of the flange design. Furthermore, seismic analyses of the upper flange were performed to identify dynamic behavior with respect to the seismic and impact input. The mode superposition and full transient methods were used to perform time-history analyses, and the displacement at the lower end of the flange was obtained. The effect of the damping ratio on the response of the flange was also evaluated, and the acceleration was obtained. The results of elastic and seismic analyses in this study will be used as basic information to judge whether a flange design meets the acceptance criteria.

Active Control of Isolation Table Using $H_\infty$ Control ($H_\infty$ 제어를 이용한 방진대의 능동제어)

  • Kim, Kyu-Young;Yang, Hyun-seok;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3079-3094
    • /
    • 1996
  • Recently, the high-precision vibration attenuation technology becomes the essence fo the seccessful development of high-integrated and ultra-precision industries, and is expected to continue playing a key role in the enhancement of manufacturing technology. Vibration isolation system using an air-spring is widely employed owing to its excellent isolation characteristics in a wide frequency range. It has, however, some drawbacks such as low-stiffness and low-damping features and can be easily excited by exogenous disturbances, and then vibration of table is remained for a long time. Consequently, the need for active vibration control for an air-spring vibration isolation system becomes inevitable. Furthermore, for an air-spring isolation table to be successfully employed in a variety of manufacturing sites, it should have a guaranteed robust performance not only to exogenous disturbances but also to uncertainties due to various equipments which might be put on the table. In this study, an active vibration suppression control system using H.inf. theory is designed and experiments are performed to verify its robust performance. An air-spring vibration isolation table with voice-coil-motors as its actuators is designed and built. The table is modeled as 3 degree-of-freedom system. An active control system is designed based on $H_\infty$control theory using frequency-shaped weighting functions. Analysis on its performance and frequency responce properties are done through numerical simulations. Robust characteristics of$H_\infty$ control on disturbances and model uncertainties are experimentally verified through (i) the transient response to the impact excitation of the table, (ii) the steady-state response to the harmonic excitation, and (iii) the response to the mass change of the table itself. An LQG controller is also designed and its performance is compared with the $H_\infty$ controller.

Application Method and EMTP-RV Simulation of Series Resonance Type Fault Current Limiter for Smart Grid based Electrical Power Distribution System (스마트 그리드 배전계통을 위한 직렬 공진형 한류기 적용 방법 및 EMTP-RV 시뮬레이션 연구)

  • Yun-Seok Ko;Woo-Cheol Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.2
    • /
    • pp.361-370
    • /
    • 2024
  • In this paper, a method was studied for applying a series resonant type fault current limiter that can be manufactured at low cost to the smart grid distribution system. First, the impact of the harmonic components of the short-circuit fault current injected into the series resonance circuit of the fault current limiter on the peak value of the transient response was analyzed, and a methodology for determining the steady-state response was studied using percent impedance-based fault current computation method. Next, the effectiveness of the method was verified by applying it to a test distribution line. The test distribution system using the designed current limiter was modeled using EMTP_RV, and a three-phase short-circuit fault was simulated. In the fault simulation results, it was confirmed that the steady-state response of the fault current accurately followed the design target value after applying the fault current limiter. In addition, by comparing the fault current waveform before and after applying the fault current limiter, it was confirmed that the fault current was greatly suppressed, confirming the effect of applying the series resonance type current limiter to the distribution system.

EDISON Co-rotational Plane Beam Transient analysis solver를 이용한 위험 Gust profile 역-추적 알고리즘 개발

  • Jeong, Ji-Seop;Kim, Se-Il;Sin, Sang-Jun
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.259-269
    • /
    • 2017
  • Gust load is a very important load factor in designing various structures of an aircraft and judging its stability. This is because the blast effect on the aircraft in operation increases the risk of damage to the structure of the aircraft and causes a negative impact such as shortening the fatigue life by generating vibration. Particularly in the case of wing, a change in angle of attack is caused by gust load, and an additional lift acts on the wing, thereby being exposed to various excitational environments. Severe structural damage to the aircraft may occur if the natural frequencies of the aircraft wing are close to or coincident with the frequencies of the gust load applied to the wing. Recent trends of research include flight dynamics analysis considering discontinuous gusts or structural optimization of the blades under gust load. A number of studies have been conducted to interpret gust load response in consideration of irregularities in gusts. In this paper, we tried to imagine the situation of the aircraft subjected to the gust load as realistic as possible, and proposed an algorithm to track back the critical gust profile according to given aircraft characteristics from the viewpoint of preliminary engineering prediction.

  • PDF

The Simulation of Transmission Line Fault-Induced Noise Signals. (선로고장시 발생되는 잡음의 시뮬레이션)

  • Shin, Myung-Chul;Kim, Mu-Woong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.454-456
    • /
    • 1987
  • A more specialized area of transient evaluations is transmission line fault-detecting and protection system. During the first cycle or two following a power system fault, a high-speed protective relay is expected to make a decision as to the severity or location of the fault, usually based on 60 Hz information, i.e. the phase and magnitude of 60 Hz voltage or current signals. It is precisely at this time however that the signal is badly corrupted by noise, in the form of a de offset or frequencies above 50 Hz. One of several possible sources of transients in protection measuring signals is in the primary system for which protection is required in its response to the impact of short circuit fault on-set. Other sources are in the primary voltage and current transducers from which protection signals are derived, and, often of particular importance, in the interface circuits between the transducer secondaries and the comparator and measuring elements of the protection system. However, the noise signals that will be described in this paper are due to the main power system only and do not include errors due to current or voltage transducers.

  • PDF

Improvement of PLL Method for Voltage Control of Dynamic Voltage Restorer (동적전압보상기의 전압제어를 위한 PLL 방식의 개선)

  • Kim, Byong-Seob;Choi, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.936-943
    • /
    • 2009
  • Dynamic voltage restorer(DVR) is now more preferable enhancement than other power quality enhancement in industry to reduce the impact of voltage faults, especially voltage sags to sensitive loads. The main controllers for DVR consists of PLL(phase locked loop), compensation voltage calculator and voltage compensator. PLL detects the voltage faults and phase. Compensation voltage calculator calculates the reference voltage from the source voltage and phase. With calculated compensation voltage from PLL, voltage compensator restores the source voltage. If PLL detect ideal phase, compensation voltage calculator calculates ideal compensation voltage. Therefore, PLL for DVR is very important. This paper proposes the new method of PLL in DVR. First, the power circuit of DVR system is analyzed in order to compensate the voltage sags. Based on the analysis, new PLL for improving transient response of DVR is proposed. The proposed method uses band rejection filter(BRF) at q-axis in synchronous flame. In order to calculate compensation voltage in commercial instruments, the PQR theory is used. Proposed PLL method is demonstrated through simulation using Matlab-Simulink and experiment, and by checking load voltage, confirms operation of the DVR

Application of Tabu Search in Design of Fuzzy Controller for Firing Angle of TCSC Improving Transient Stability (과도 안정도 향상을 위한 TCSC의 점호각 제어용 퍼지제어기의 설계에 Tabu 탐색법의 적용)

  • Kim, U-Geun;Hwang, Gi-Hyeon;Kim, Hyeong-Su;Park, Jun-Ho;Park, Jung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.12
    • /
    • pp.561-567
    • /
    • 2001
  • This paper describes the application of Fuzzy Logic Controller (FLC) to Thyristor Controlled Series Capacitor (TCSC) which can have significant impact on power system dynamics. The function of the FLC is to control the firing angle of the TCSC. We tuned the scaling factors of the FLC using Tabu Search. The proposed FLC is used for damping the low frequency oscillations caused by disturbances such as the sudden changes of small or large loads or the outages in the generators or transmission lines. To evaluate usefulness of the proposed FLC, we performed the computer simulation fur single-machine infinite system. The response of FLC is compared with that of PD controller optimized using Tabu Search. Simulation results that the FLC shows better control performance than PD controller.

  • PDF

Control Strategies for Landing Quadcopters on Ships with Legged Platform Based on Impedance Control (선박 위 착륙을 위한 임피던스 제어기반 쿼드콥터 족형 랜딩플랫폼 제어 전략)

  • Hwang, Seonghyeon;Lee, Seunghyeon;Jin, Seongho;Lee, Inho
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.1
    • /
    • pp.48-57
    • /
    • 2022
  • In this paper, we propose a legged landing platform for the quadcopter taking off and landing in the ship environment. In the ship environment with waves and winds, the aircraft has risks being overturned by contact impact and excessive inclination during landing on the ship. This landing platform has four landing legs under the quadcopter for balancing and shock relief. In order to make the quadcopter balanced on ships, the position of each end effector was controlled by PID control. And shocks have mainly happened when quadcopter contacts the ship's surface as well as legs move fast. Hence, impedance control was used to cope with the shocks. The performance of the landing platform was demonstrated by a simulation and a prototype in three sea states based on a specific size of a ship. During landing and tracking the slope of the ship's surface, oscillations of rotation and translation from the shock were mitigated by the controller. As a result, it was verified that transient response and stability got better by adding impedance control in simulation models and prototype experiments.

DYNAMIC 3-DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR FRACTURE MECHANISM (충격하중(衝擊荷重)과 하악골(下顎骨) 골절발생(骨折發生) 기전(機轉)의 유한요소법적(有限要素法的) 연구(硏究))

  • Oh, Seung-Hwan;Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.470-487
    • /
    • 1996
  • The purpose of this study was to investigate the dynamic response of the mandible to impact and provide insight into the fracture mechanism of the mandible, by 3-dimensional finite element method. The finite element model of the mandible was developed and calculated using NASTRAN/XL (MSC co. U.S.A.) and the linear dynamic transient analysis was performed according to the impulsive force direction, force type and impulse time to the mandible. At first, the load was applied on the mandibular symphysis, body, angle and subcondylar area in the horizontal mandibular plane and the computed stress-time histories at 14 locations of the mandible were obtained. Secondly, the impulsive force was directed to the symphyseal area with changing the force magnitude and impulse time, and calculated the node displacement at 8 locations of mandible. The conclusions from from this study were as follows. 1. The appearance of impulsive energy transmission was different to the direction of impulse to the mandible. 2. The impulsive stress and deformation were larger in lingual or medial side than buccal or lateral in the mandible. 3. The velocity, appearance of energy transmission and the fracture pattern in mandible were affected rather impulse time than force. 4. The horizontal impact to the one side of mandible did not have effect on the stress and displacement of contralateral mandible. From the above results, fracture pattern in symphysis can be showed as simple or comminuted, multiple or associated in body and angle and solitary in subcondyle area.

  • PDF