• Title/Summary/Keyword: impact imaging

Search Result 265, Processing Time 0.024 seconds

Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials

  • de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Cavalcanti, Yuri Wanderley;de Lima, Elisa Diniz;Bento, Patricia Meira;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.141-151
    • /
    • 2020
  • Purpose: This study aimed to quantify the influence of tooth position within the field-of-view (FOV) on cone-beam computed tomography (CBCT) imaging artifacts' intensity when assessing teeth restored with various intracanal materials. Materials and Methods: Seventy single-rooted teeth were divided into 7 groups (10 teeth per group): NiCr post (NC), AgPd post (AP), metal core fiberglass post (MCFG), fiberglass post (FG), anatomical fiberglass post (AFG), fiberglass post cemented with core build-up cement (FGCo), and anatomical fiberglass post cemented with core build-up cement (AFGCo). All posts were cemented using a regular dual-curing resin cement (Allcem), except FGCo and AFGCo which were cemented with a core build-up dual-curing resin cement (AllcemCore). Each tooth was scanned on a CS9000 in 5 positions within the FOV: a central position, anterior horizontal peripheral, peripheral superior, peripheral inferior, and posterior horizontal peripheral position. Hyperdense, hypodense, remaining teeth areas and ROI areas were quantitatively analyzed using ImageJ software. Results: Posterior horizontal peripheral position increased the intensity of artifacts on FGCo and AFGCo post groups (P<0.05), and specifically the hypodense artifact intensity on FG and AFG post groups (P<0.05). NC and AP groups presented greater intensity of artifacts than any other post groups(P<0.05). Conclusion: Artifact intensity increases in the presence of high atomic number materials and when the object is not centered within the FOV. The impact of positioning within the FOV on artifact was greater for fiberglass posts cemented with core build-up dual-curing cement than for metal posts and fiberglass posts cemented with regular dual-curing cement.

The Potential of Diffusion-Weighted Magnetic Resonance Imaging for Predicting the Outcomes of Chronic Subdural Hematomas

  • Lee, Seung-Hwan;Choi, Jong-Il;Lim, Dong-Jun;Ha, Sung-Kon;Kim, Sang-Dae;Kim, Se-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.1
    • /
    • pp.97-104
    • /
    • 2018
  • Objective : Diffusion-weighted magnetic resonance imaging (DW-MRI) has proven useful in the study of the natural history of ischemic stroke. However, the potential of DW-MRI for the evaluation of chronic subdural hematoma (CSDH) has not been established. In this study, we investigated DW-MRI findings of CSDH and evaluated the impact of the image findings on postoperative outcomes of CSDH. Methods : We studied 131 CSDH patients who had undergone single burr hole drainage surgery. The images of the subdural hematomas on preoperative DW-MRI and computed tomography (CT) were divided into three groups based on their signal intensity and density : 1) homogeneous (iso or low) density on CT and homogeneous low signal intensity on DW-MRI; 2) homogeneous (iso or low) density on CT and mixed signal intensity on DW-MRI; and 3) heterogeneous density on CT and mixed signal intensity on DW-MRI. On the basis of postoperative CT, we also divided the patients into 3 groups of surgical outcomes according to residual hematoma and mass effect. Results : Analysis showed statistically significant differences in surgical (A to B : p<0.001, A to C : p<0.001, B to C : p=0.129) and functional (A to B : p=0.039, A to C : p<0.001, B to C : p=0.108) outcomes and treatment failure rates (A to B : p=0.037, A to C : p=0.03, B to C : p=1) between the study groups. In particular, group B and group C showed worse outcomes and higher treatment failure rates than group A. Conclusion : CSDH with homogeneous density on CT was characterized by signal intensity on DW-MRI. In CSDH patients, performing DW-MRI as well as CT helps to predict postoperative treatment failure or complications.

Neural Substrates of Posttraumatic Stress Disorder : Functional Magnetic Resonance Imaging Study Using Negative Priming Task (외상 후 스트레스 장애의 신경기반 : 부적점화과제와 기능자기공명영상 연구)

  • Lee, Byeong-Taek;Ryu, Jeong;Lee, Dong Hoon;Sohn, Myeong-Ho;Kang, Nae Hee;Ham, Byung-Joo;Choi, Nam Hee
    • Korean Journal of Biological Psychiatry
    • /
    • v.15 no.2
    • /
    • pp.110-117
    • /
    • 2008
  • Objectives : Posttraumatic stress disorder(PTSD) has been primarily associated with emotional problems. Recently, however, the impact of PTSD on cognitive processes has interested a growing number of researchers. The current study is aimed at investigating the cognitive aspects of PTSD at both behavioral and neurological levels. Methods : We recruited individuals with PTSD who survived the Daegu subway explosion in 2003 as well as non-PTSD individuals as a control group. To evaluate the inhibitory processes and the neural mechanisms, we had these individuals perform the negative priming task simultaneously with functional MRI scanning. Results : Behaviorally, the negative priming effect was intact in the control group but was not evident in the PTSD group. In the imaging results, only the PTSD group showed the negative priming effect (i.e., increased activation of the negative priming condition as opposed to the neutral condition) in the dorsolateral prefrontal cortex, anterior cingulate cortex, and inferior temporal gyrus. The PTSD group also showed increased activity for the positive priming condition as opposed to the neutral condition in the claustrum. These results confirm and extend the previous findings that the integrity of the ACC is compromised in the trauma survivors due to disrupted white matter tract. Conclusions : The current results suggest that deteriorated performance of the PTSD group may be due to the functional problem as well as the structural abnormalities.

  • PDF

Pseudoglandular Formation in Hepatocellular Carcinoma Determines Apparent Diffusion Coefficient in Diffusion-Weighted MRI

  • Park, In Kyung;Yu, Jeong-Sik;Cho, Eun-Suk;Kim, Joo Hee;Chung, Jae-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • Purpose: To determine the impact of pseudoglandular formation on apparent diffusion coefficient (ADC) values of hepatocellular carcinoma (HCC) in diffusion-weighted imaging (DWI), and to validate the results using histopathological grades. Materials and Methods: We assessed 182 HCCs surgically resected from 169 consecutive patients. Each type of tumor pseudoglandular formation was categorized into "non-," "mixed-," or "pure-," based on official histopathology reports. The ADC for each tumor was independently measured, using the largest region of interest on the ADC map. Data were assessed using the analysis of variance test, with Bonferroni correction for post hoc analysis to stratify the relationship of ADCs with pseudoglandular formation, followed by subgroup analysis according to the histopathological tumor grades. Results: The mean ADC was significantly higher in pure pseudoglandular lesions (n = 5, $1.29{\pm}0.08{\times}10^{-3}mm^2/s$) than in non-pseudoglandular lesions (n = 132, $1.08{\pm}0.17{\times}10^{-3}mm^2/s$; P = 0.003) or mixed-pseudoglandular lesions (n = 45, $1.16{\pm}0.24{\times}10^{-3}mm^2/s$; P = 0.034). The ADC values and pseudoglandular formation were significantly correlated in moderately differentiated HCCs (n = 103; r = 0.307, P = 0.007), while well- (n = 19) and poorly-differentiated HCCs (n = 60) did not show significant correlation (r = 0.105 and 0.068, respectively; P = 0.600 and 0.685, respectively). Conclusion: The degree of pseudoglandular formation could be one of the determinants of ADC in DWI of HCCs-especially moderately differentiated HCCs-while its influence does not appear to be significant in well- or poorly differentiated HCCs.

Parent Perspectives of Diagnostic and Monitoring Tests Undertaken by Their Child with Inflammatory Bowel Disease

  • Ho, Shaun Siong Chung;Keenan, Jacqueline Ilene;Day, Andrew Stewart
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.1
    • /
    • pp.19-29
    • /
    • 2021
  • Purpose: To assess parent perspectives of the current and potential future tests for their child with inflammatory bowel disease (IBD). Methods: New Zealand parents of a child with IBD were invited to complete an anonymous online survey. Experiences relating to their child's blood or faecal tests, medical imaging (abdominal ultrasound [US], abdominal computerised tomography [CT] and magnetic resonance enterography) and colonoscopy were collected. Perceived attitudes to potential future testing of urine, saliva, and breath, were sought. Results: Twenty-eight parents, 93% female completed the survey, and 86% were aged between 35 and 54 years. Baseline information was provided by parents for 27 of 28 children, 70.3% had Crohn's disease with a mean disease duration of 2.67 years. Blood tests were the most requested and completed tests, while CT was the least ordered and most refused test. Colonoscopy was rated as the least comfortable and generated the most worry. Explanation of test significantly improved parent's levels of understanding when their child had blood, faecal, imaging (US) or colonoscopy tests. Providing an explanation, test invasiveness and the impact of the blood results may have on their child's treatment significantly improved parents' comfort levels. However, explanation of colonoscopy generated a significant parental concerns. Saliva, urine and blood tests were chosen as the most preferred disease monitoring tests. Conclusion: Parents preferred any tests less invasive than colonoscopy for monitoring their child's IBD. Although providing explanation of their child's tests enhanced parents' understanding, it can also affect parents' levels of concern and comfort.

Development and validation of a clinical phantom reproducing various lesions for oral and maxillofacial radiology research

  • Han-Gyeol Yeom;Jo-Eun Kim;Kyung-Hoe Huh;Won-Jin Yi;Min-Suk Heo;Sam-Sun Lee
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.345-353
    • /
    • 2023
  • Purpose: The objective of this study was to propose a method for developing a clinical phantom to reproduce various diseases that are clinically prevalent in the field of dentistry. This could facilitate diverse clinical research without unnecessarily exposing patients to radiation. Materials and Methods: This study utilized a single dry skull, which was visually and radiographically examined to evaluate its condition. Existing lesions on the dry skull were preserved, and other relevant lesions were artificially created as necessary. These lesions were then documented using intraoral radiography and cone-beam computed tomography. Once all pre-existing and reproduced lesions were confirmed by the consensus of 2 oral and maxillofacial radiologists, the skull was embedded in a soft tissue substitute. To validate the process, cone-beam computed tomography scans and panoramic radiographs were obtained of the fabricated phantom. All acquired images were subsequently evaluated. Results: Most lesions could be identified on panoramic radiographs, although some sialoliths and cracked teeth were confirmed only through cone-beam computed tomographic images. A small gap was observed between the epoxy resin and the bone structures. However, 2 oral and maxillofacial radiologists agreed that this space did not meaningfully impact the interpretation process. Conclusion: The newly developed phantom has potential for use as a standardized phantom within the dental field. It may be utilized for a variety of imaging studies, not only for optimization purposes, but also for addressing other experimental issues related to both 2- and 3-dimensional diagnostic radiography.

Cardiovascular Magnetic Resonance Versus Histopathologic Study for Diagnosis of Benign and Malignant Cardiac Tumours: A Systematic Review and Meta-Analysis

  • Sandra Nobrega;Catarina Martins da Costa;Ana Filipa Amador;Sofia Justo;Elisabete Martins
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.159-168
    • /
    • 2023
  • BACKGROUND: The gold standard for diagnosis of cardiac tumours is histopathological examination. Cardiovascular magnetic resonance (CMR) is a valuable non-invasive, radiation-free tool for identifying and characterizing cardiac tumours. Our aim is to understand CMR diagnosis of cardiac tumours by distinguishing benign vs. malignant tumours compared to the gold standard. METHODS: A systematic search was performed in the PubMed, Web of Science, and Scopus databases up to December 2022, and the results were reviewed by 2 independent investigators. Studies reporting CMR diagnosis were included in a meta-analysis, and pooled measures were obtained. The risk of bias was assessed using the Quality Assessment Tools from the National Institutes of Health. RESULTS: A total of 2,321 results was obtained; 10 studies were eligible, including one identified by citation search. Eight studies were included in the meta-analysis, which presented a pooled sensitivity of 93% and specificity of 94%, a diagnostic odds ratio of 185, and an area under the curve of 0.98 for CMR diagnosis of benign vs. malignant tumours. Additionally, 4 studies evaluated whether CMR diagnosis of cardiac tumours matched specific histopathological subtypes, with 73.6% achieving the correct diagnosis. CONCLUSIONS: To the best of our knowledge, this is the first published systematic review on CMR diagnosis of cardiac tumours. Compared to histopathological results, the ability to discriminate benign from malignant tumours was good but not outstanding. However, significant heterogeneity may have had an impact on our findings.

Impact of the Ventricle Size on Alzheimer's Disease Progression: A Retrospective Longitudinal Study

  • Ji-seon Lee;Do-yun Heo;Kyung-Hae Choi;Hee-Jin Kim
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.2
    • /
    • pp.95-106
    • /
    • 2024
  • Background and Purpose: Ventricle enlargement has been implicated in the pathophysiology of Alzheimer's disease (AD). We studied the relationship between ventricular size and cognitive function in patients with AD. We focused on the effect of the initial ventricle size on the rate of cognitive decline in patients with AD. Methods: A retrospective analysis of probable clinical AD participants with more than 2 magnetic resonance imaging images was performed. To measure ventricle size, we used visual rating scales of (1) Cardiovascular Health Study (CHS) score and (2) conventional linear measurement method. Results: Increased clinical dementia rating (CDR) was correlated with a decreased Mini-Mental Status Examination (MMSE) score, and increased medial temporal lobe atrophy (MTLA) and global ventricle size (p<0.001, p<0.001, p=0.021, respectively). There was a significant correlation between the change in cognitive function in the group (70%-100%ile) with a large initial ventricle size (p=0.021 for ∆CDR, p=0.01 for ∆MMSE), while the median ventricle size (30%-70%ile) showed correlation with other brain structural changes (MTLA, frontal atrophy [FA], and white matter) (p=0.036 for initial MTLA, p=0.034 for FA). Conclusions: In this study, the initial ventricle size may be a potential new imaging biomarker for initial cognitive function and clinical progression in AD. We found a relationship between the initial ventricle size and initial AD-related brain structural biomarkers.

Combination of metal artifact reduction and sharpening filter application for horizontal root fracture diagnosis in teeth adjacent to a zirconia implant

  • Debora Costa Ruiz;Larissa de Oliveira Reis;Rocharles Cavalcante Fontenele;Murilo Miranda-Viana;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.289-295
    • /
    • 2024
  • Purpose: This study examined the influence of metal artifact reduction (MAR), the application of sharpening filters, and their combination on the diagnosis of horizontal root fracture (HRF) in teeth adjacent to a zirconia implant on cone-beam computed tomography (CBCT) examinations. Materials and Methods: Nineteen single-rooted teeth (9 with HRF and 10 without) were individually positioned in the right central incisor socket of a dry human maxilla. A zirconia implant was placed adjacent to each tooth. Imaging was performed using an OP300 Maxio CBCT (Instrumentarium, Tuusula, Finland) unit with the following settings: a current of 8 mA, both MAR modes(enabled and disabled), a 5×5 cm field of view, a voxel size of 0.085 mm, and a peak kilovoltage of 90 kVp. Four oral and maxillofacial radiologists independently evaluated the CBCT scans under both MAR conditions and across 3 levels of sharpening filter application (none, Sharpen 1×, and Sharpen 2×). Diagnostic metrics were calculated and compared using 2-way analysis of variance (α=5%). The weighted kappa test was used to assess intra- and inter-examiner reliability in the diagnosis of HRF. Results: MAR tool activation, sharpening filter use, and their combination did not significantly impact the area under the receiver operating characteristic curve, sensitivity, or specificity of HRF diagnosis (P>0.05). Intra- and inter-examiner agreement ranged from fair to substantial. Conclusion: The diagnosis of HRF in a tooth adjacent to a zirconia implant is not affected by the activation of MAR, the application of a sharpening filter, or the combination of these tools.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.