• Title/Summary/Keyword: impact damage

Search Result 1,650, Processing Time 0.034 seconds

A Study on the Effect of Fire Heat on the Durability of Concrete Structures Repaired and Reinforced with Epoxy Resin (화열(火熱)이 에폭시수지로 보수·보강된 콘크리트 구조체의 내구성에 미치는 영향에 관한 연구)

  • Tai Kwan Cho
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.138-145
    • /
    • 2023
  • Purpose: In accordance with the increase in the number of buildings repaired and reinforced following deterioration from when a fire occurs in a previously reinforced building, the impact on the structure after the fire is analyzed to establish standards for repair and reinforcement measures. Method: After curing for 28 days, the process was to measure the compressive strength and induce destruction through a compressor, repair and reinforce it with epoxy, and conduct a re-compressive strength test on some specimens after curing for 3 days to understand the degree of strength restoration. The rest of the repaired and reinforced specimens as well as the unrepaired and unreinforced specimens were then put into an oven and heated according to the temporal and temperate conditions listed below, and then the compressive strength was tested to estimate the impact of fire. Result: After reinforcing the yielded specimen with epoxy, the process was to then put it in an oven and heat it at different temperatures over time. It was found that there was a decrease in the strength of the reinforcement more than that of the actual specimen. Conclusion: Based on this, it was found that a building repaired and reinforced with epoxy resin is actually more dangerous than a general unrepaired building when it is damaged by fire, and thus, that it must be prepared for fire vulnerabilities.

Applying the TDR for Urban Landscape Management: Focusing on the Use of REITs (도시 경관관리를 위한 개발권양도제 정책도입에 관한 연구: 리츠 접목을 중심으로)

  • Dongoh Ha;Jaeweon Yeom;Juchul Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.4
    • /
    • pp.242-250
    • /
    • 2023
  • The continuity of urban space is being destroyed by disorderly high-rise development caused by reckless development, and the resulting deterioration of urban landscape is emerging as a major problem. Disordered high-rise development is adversely affecting the urban environment, such as depriving residents of the basic rights of view and sunlight and privatizing the scenery that urban residents should enjoy together. In order to create a continuous urban landscape, indiscriminate high-rise development is restricted and compensation for the affected areas is needed. Various regulations have been carried out to this end, but it is difficult to overcome the pressure and damage to high-rise development by regulations alone. Accordingly, discussions have been underway to introduce a compensation system. Among them, discussions on the introduction of a 'Transfer of Development Right' (TDR) in which land ownership and development rights are separated and compensated for development rights have been drawing attention. However, in Korea, it is difficult to introduce the system due to various problems related to the separation of development rights. In order to overcome the limitations of the introduction of TDR, this paper analyzed the concepts and characteristics of 'Real Estate Investment Trusts' (REITs) and presented a policy model for the development right transfer system incorporating REITs for effective landscape management.

Psychological Changes and Visual Preferences of Floating Solar Photovoltanics - Focusing on EEG and SD Methods - (수상 태양광발전시설의 심리적 변화 및 시각적 선호도 - 뇌파(EEG) 및 SD법을 중심으로 -)

  • Zhang, YuJie;Jung, Teayeol;Seo, Seonghyeok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.131-142
    • /
    • 2023
  • Solar power facilities to reduce carbon emissions are continuously being installed in forests, farmland, city, and on water. However, research on visual preferences and the psychological impact on observers after installing solar power facilities is insufficient. Therefore, in this study, shooting was conducted according to the viewing distance of the near, middle, and distant views of Hapcheon Dam, Korea's largest floating photovoltaic power plant. The acquired images were edited using Photoshop to compare the presence or absence of floating photovoltaic power generation facilities. In addition, psychological changes and visual preferences were analyzed through an EEG test and questionnaire among 50 participants. The results are summarized, as follows. First, the installation of water photovoltaic power generation facilities has a passive impact on the subjects' psychological changes and visual preference. Second, the psychological changes due to the installation of water photovoltaic power generation facilities were judged to affect almost all research subjects, regardless of nationality, gender, or universisty major. Third, the visual preference for installing the water photovoltaic power generation facility is low, which can be interpreted as the water photovoltaic power generation facility negatively affecting the "friendliness" and "naturalness" of the landscape. In addition, this change in visual preference was found to differ depending on the gender and universiity major of the subjects. Fourth, the psychological change and visual preference of the floating photovoltaic power generation facility according to the viewing distance, found that the close range had a higher effect than the middle and distant ranges.

Modeling the Effect of Intake Depth on the Thermal Stratification and Outflow Water Temperature of Hapcheon Reservoir (취수 수심이 합천호의 수온성층과 방류 수온에 미치는 영향 모델링)

  • Sun-A Chong;Hye-Ji Kim;Hye-Suk Yi
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.473-487
    • /
    • 2023
  • Korea's multi-purpose dams, which were constructed in the 1970s and 1980s, have a single outlet located near the bottom for hydropower generation. Problems such as freezing damage to crops due to cold water discharge and an increase the foggy days have been raised downstream of some dams. In this study, we analyzed the effect of water intake depth on the reservoir's water temperature stratification structure and outflow temperature targeting Hapcheon Reservoir, where hypolimnetic withdrawal is drawn via a fixed depth outlet. Using AEM3D, a three-dimensional hydrodynamic water quality model, the vertical water temperature distribution of Hapcheon Reservoir was reproduced and the seasonal water temperature stratification structure was analyzed. Simulation periods were wet and dry year to compare and analyze changes in water temperature stratification according to hydrological conditions. In addition, by applying the intake depth change scenario, the effect of water intake depth on the thermal structure was analyzed. As a result of the simulation, it was analyzed that if the hypolimnetic withdrawal is changed to epilimnetic withdrawal, the formation location of the thermocline will decrease by 6.5 m in the wet year and 6.8 m in the dry year, resulting in a shallower water depth. Additionally, the water stability indices, Schmidt Stability Index (SSI) and Buoyancy frequency (N2), were found to increase, resulting in an increase in thermal stratification strength. Changing higher withdrawal elevations, the annual average discharge water temperature increases by 3.5℃ in the wet year and by 5.0℃ in the dry year, which reduces the influence of the downstream river. However, the volume of the low-water temperature layer and the strength of the water temperature stratification within the lake increase, so the water intake depth is a major factor in dam operation for future water quality management.

A Study on the Status of Fine Dust Generated from Construction Waste Intermediate Treatment Plants in Rural Area and Its Impact on Neighboring Areas (농촌지역 건설폐기물 중간처리 사업장에서 발생하는 미세먼지의 발생 현황 및 인근 지역에 미치는 영향 연구)

  • Jang, Kyong-Pil;Park, Ji-Sun;Kim, Byung-Yun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.25 no.4
    • /
    • pp.9-16
    • /
    • 2023
  • In this study, the status and characteristics of fine dust and its impact on neighboring areas were investigated to proactively respond to the government's environmental regulations expected in the future and to minimize the damage by the fine dust generated at construction waste intermediate treatment plants. In addition, since there are no such plants that can affect the surroundings with no houses or other waste treatment sites nearby, an independently located construction waste intermediate treatment plant was selected to compare the characteristics of fine dust with that from the construction waste intermediate treatment sites located in the downtown area. The conclusions of the study are as follows. (1) The measurement results of PM10 at 4 points in the plant showed that the location where the crushing facility was operating had an elevated level of fine dust at 80㎍/m3 on average and a maximum of 124㎍/m3, and the level rose to 110㎍/m3 at points where vehicles frequent. (2) The PM2.5 measurement results inside the plant showed that the average concentration of the reference point was 16㎍/m3 and the maximum value was 20㎍/m3, which was distributed within the management standard. (3) It was found that the average concentration of PM10 in the nearby area ranged from 28 to 38㎍/m3, which was similar to or lower than 36㎍/m3 of the reference point. Therefore, the concentration of the fine dust generated in the plant had a negligible effect on the increase in concentration of fine dust in nearby areas. (4) The heavy metal contents were measured from the filter paper collected from the plant. The PM10 was found to be about 14 to 26ng/m3, and PM 2.5 was 25 to 28ng/m3, which was the average of domestic atmospheric concentrations. (5) The SEM-EDX analysis results showed that the PM10 contained Si and O around 40% similarly for both. The SiO2, a component of silica occupied the most and C was present as CaCO3, which was assumed to be a limestone component. The remaining components included NaO, Al2O3, and CaO as trace oxides. (6) The SEM-EDX analysis results showed that the PM 2.5 contained 5 to 7% of Cl, which is a chlorine ion, and a small amount of K was detected at 2.51% in the sample from the shutdown plant.

Impact Range Analysis of Small LPG Storage Tank Explosions at Highway Rest Areas (고속도로 휴게소 소형 LPG 저장탱크 폭발에 따른 영향범위 분석)

  • Seung duk Jeon;Soon Beom Lee;Jai Young Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.319-327
    • /
    • 2023
  • This study analyzes the risks of explosions of small LPG storage tanks installed at highway rest areas. For this purpose, the ranges of the effect of thermal radiation and overpressure caused by the BLEVE(Boiling Liquid Expansion Vapor Explosion)and VCE(Vapor Cloud Explosion) of a 2900-kg small LPG storage tank installed at highway rest areas were quantitatively evaluated by applying the Areal Location of Hazardous Atmospheres program. The ranges of influence of the derived explosion overpressure and thermal radiation were found to have a maximum radii of 336 m and 423 m, respectively. The study determined that those within 269 m could be severely injured by an explosion overpressure of 3.5 psi, and fatalities from thermal radiation of 10 kw/m2 could occur within 192 m of the exploded storage tank. The safety management plan for the LPG storage tank was discussed while considering the auxiliary facilities of highway rest areas and the extent of the damage impact. These research results will help improve safety accident prevention regulations considering the environment and facilities of the rest areas as well as the safety management of small LPG storage tanks installed at highway rest areas.

An Analysis of the Support Policy for Small Businesses in the Post-Covid-19 Era Using the LDA Topic Model (LDA 토픽 모델을 활용한 포스트 Covid-19 시대의 소상공인 지원정책 분석)

  • Kyung-Do Suh;Jung-il Choi;Pan-Am Choi;Jaerim Jung
    • Journal of Industrial Convergence
    • /
    • v.22 no.6
    • /
    • pp.51-59
    • /
    • 2024
  • The purpose of the paper is to suggest government policies that are practically helpful to small business owners in pandemic situations such as COVID-19. To this end, keyword frequency analysis and word cloud analysis of text mining analysis were performed by crawling news articles centered on the keywords "COVID-19 Support for Small Businesses", "The Impact of Small Businesses by Response System to COVID-19 Infectious Diseases", and "COVID-19 Small Business Economic Policy", and major issues were identified through LDA topic modeling analysis. As a result of conducting LDA topic modeling, the support policy for small business owners formed a topic label with government cash and financial support, and the impact of small business owners according to the COVID-19 infectious disease response system formed a topic label with a government-led quarantine system and an individual-led quarantine system, and the COVID-19 economic policy formed a topic label with a policy for small business owners to acquire economic crisis and self-sustainability. Focusing on the organized topic label, it was intended to provide basic data for small business owners to understand the damage reduction policy for small business owners and the policy for enhancing market competitiveness in the future pandemic situation.

Vulnerability Assessment Procedure for the Warship Including the Effect of Shotline and Penetration of Fragments (탄두의 관통 효과를 고려한 함정 취약성 평가 절차에 관한 기본 연구)

  • Kim, Kwang-Sik;Lee, Jang-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.3
    • /
    • pp.254-263
    • /
    • 2012
  • The survivability of warship is assessed by susceptibility, vulnerability and recoverability. Essentially, a vulnerability assessment is a measure of the effectiveness of a warship to resist hostile weapon effects. Considering the shot line and its penetration effect on the warship, present study introduces the procedural aspects of vulnerability assessments of warship. Present study also considers the prediction of penetration damage to a target caused by the impact of projectiles. It reflects the interaction between the weapon and the target from a perspective of vulnerable area method and COVART model. The shotline and tracing calculation have been directly integrated into the vulnerability assessment method based on the penetration equation empirically obtained. A simplified geometric description of the desired target and specification of a threat type is incorporated with the penetration effect. This study describes how to expand the vulnerable area assessment method to the penetration effect. Finally, an example shows that the proposed method can provide the vulnerability parameters of the warship or its component under threat being hit through tracing the shotline path thereby enabling the vulnerability calculation. In addition, the proposed procedure enabling the calculation of the component's multi-hit vulnerability introduces a propulsion system in dealing with redundant Non-overlapping components.

Emission Characteristics of Encapsulated Organic Light Emitting Devices Using Attaching Film and Flat Glass (접착 필름과 평판 유리를 이용하여 봉지된 유기 발광 소자의 발광 특성)

  • Lim, Su Yong;Yang, Jae-Woong;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.3
    • /
    • pp.111-115
    • /
    • 2013
  • To study the encapsulation method for large-area organic light emitting devices (OLEDs), OLED of ITO / 2-TNATA / NPB / $Alq_3$:Rubrene / $Alq_3$ / LiF / Al structure was fabricated, which on $Alq_3$/LiF/Al as protective layer of OLED was deposited to protect the damage of OLED, and subsequently it was encapsulated using attaching film and flat glass. The current density and luminance of encapsulated OLED using attaching film and flat glass has similar characteristics compared with non-encapsulated OLED when thickness of Al as a protective layer was 1200 nm, otherwise power efficiency of encapsulated OLED was better than non-encapsulated OLED. Encapsulation process using attaching film and flat glass did not have any effects on the emission spectrum and the Commission International de L'Eclairage (CIE) coordinate. The lifetime of encapsulated OLED using attaching film and flat glass was 287 hours in 1200 nm Al thickness, which was increased according to thickness of Al protective layer, and was improved 54% compared with 186 hours in same Al thickness, lifetime of encapsulated OLED using epoxy and flat glass. As a result, it showed the improved efficiency and the long lifetime, because the encapsulation method using attaching film and flat glass could minimize the impact on OLED caused through UV hardening process in case of glass encapsulation using epoxy.

Damage of Steel Composite Hollow RC SFT under Fires (강합성 중공 RC 해중터널의 화재시 손상도 분석)

  • Seo, JiHye;Han, Taek Hee;Han, Sang Hun;Park, Woo-Sun;Won, Deok Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4626-4633
    • /
    • 2014
  • The research is being conducted on a SFT (Submerged Floating Tunnel), because of increased exchange among nations and abnormal weather-disasters and new transportation infrastructure has attracted interest. However, studies in this are almost in the early stages around the world and various researches will be needed to promote the safety form the disaster. In this paper, heat transfer analysis was applied among the structural performance evaluation of a SFT if afire occurs in the tunnel. The analysis model of the SFT was performed as steel composite RC hollow. The impact of heat by fire under a range of fire scenarios was analyzed and prevention techniques were examined.