• 제목/요약/키워드: immunoassay

검색결과 572건 처리시간 0.024초

Role of ghrelin in the pancreatic exocrine secretion via mitogen-activated protein kinase signaling in rats

  • Lee, Kyung-Hoon;Lee, Jae-Sung;Wang, Tao;Oh, Jin-Ju;Roh, Sanggun;Lee, Hong-Gu
    • Journal of Animal Science and Technology
    • /
    • 제59권7호
    • /
    • pp.16.1-16.6
    • /
    • 2017
  • Background: This study was performed to investigate the impact of exogenous ghrelin on the pancreatic ${\alpha}$-amylase outputs and responses of pancreatic proteins to ghrelin that may relate to pancreatic exocrine. Methods: Sprague-Dawley male rats (9 weeks old, $300{\pm}10g$) were injected with ghrelin via intraperitoneal (i.p.) infusion at dosage of 0, 0.1, 1.0 and $10.0{\mu}g/kg$ body weight (BW), respectively. The plasma ghrelin and cholecystokinin (CCK) level were determined using enzyme immunoassay kit; the mRNA expression of ghrelin receptor ($GHSR-1{\alpha}$) and growth hormone (GH) receptor were assessed by reverse transcription PCR; the expressions of pancreatic ${\alpha}$-amylase activity, extracellular-signal-regulated kinases (ERK), phosphorylated extracellular-signal-regulated kinases (pERK) and c-Jun N-terminal kinase (JNK) were evaluated by western blotting; moreover the responses of pancreatic proteins to ghrelin were analyzed using the two-dimensional gel electrophoresis system. Results: The exogenous ghrelin (1.0 and $10.0{\mu}g/kg\;BW$) elevated the level of plasma ghrelin (p < 0.05), and suppressed the expression of pancreatic ${\alpha}$-amylase at a dose of $10.0{\mu}g/kg\;BW$ (p < 0.05). No difference in the level of plasma CCK was observed, even though rats were exposed to any dose of exogenous ghrelin. In addition, a combination of western blot and proteomic analysis revealed exogenous ghrelin ($10.0{\mu}g/kg\;BW$) induced increasing the JNK and ERK expressions (p < 0.05) and four proteins such as Destrin, Anionic trypsin-1, Trypsinogen, and especially eukaryotic translation initiation factor 3 in rat pancreas. Conclusions: Taken together, exogenous ghrelin by i.p. infusion plays a role in the pancreatic exocrine secretion via mitogen-activated protein kinase signaling pathway.

Detection of Antibody to Hepatitis C Virus in Psychiatric Inpatients (정신과(精神科) 입원(入院) 환자(患者)의 C형(型) 간염(肝炎) 항체(抗體) 양성솔(陽性率))

  • Cheon, Jin-Sook;Han, Ho-Sung
    • Korean Journal of Biological Psychiatry
    • /
    • 제2권1호
    • /
    • pp.100-106
    • /
    • 1995
  • Antibodies to hepatitis C drew attention because of high morbidity to chronic hepatitis, liver cirrhosis and hepatocellular carcinoma. HCV was known to be transmitted by transfusion, sexual behavior and parenteral drug use. However, some kind of autoimmune mechanism was suggested to be involved in the genesis of HCV-induced liver diseases. We hypothesized the prevalence of having anti-HCV might be higher in psychiatric patients rather than general population because of the characteristic route of transmission. Using Abbott HCV BA kit, anti-HCV was detected in the sera of 113 psychiatric inpatients from early December in 1992 to late May in 1994. The Positivity of anti-HCY was significantly(P<0.05) higher among psychiatric inpatients(10.6%) than in healthy controls(3.0%). There were no disease specificity among psychiatric inpatients who had anti-HCV, though alcoholics tended to have more anti-HCV. We couldn't find any significant correlation of anti-HCV with age, seasons of birth, lymphocytes (%) and liver function.

  • PDF

Radioimmunoassay Using Quality Control Materials BIO-RAD of the Suggestions for Setting Acceptable Range (BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언)

  • Park, Hee-Won;Kim, Tae-Hoon;Roh, Gyeong-Un;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제16권1호
    • /
    • pp.108-114
    • /
    • 2012
  • Purpose: Immunosorbent assay most commonly used in the laboratory and commercial third-party quality control material is a substance that provided by BIO-RAD. However, in Reference Sheet by radioimmunoassay test kit or a measuring device for the mention of Acceptable Range is somewhat lacking. Radioimmunoassay for the inspection of test results by setting Acceptable Range to increase the objectivity of the recommendations on the data accumulated by the manufacturer listed in the Reference Sheet is to be issued. Materials and Methods : In our hospital since 2009 partially BIO-RAD using quality control materials in 2011, excluding certain items, some items were most of the BIO-RAD third-party quality control materials are used. Thus, internal quality control data accumulated BIO-RAD's Unity Real Time program by using the items were measured. Results : BIO-RAD using quality control material items were about 50 of the 20 Point Data averages, standard deviations, variation coefficients were calculated to measure the Acceptable Range of kit, automated immunoassay attributed Roche Elecsys / E170 / cobas e Systems the measures and compared. Conclusions : BIO-RAD QC materials commonly used hospital and peer group by setting the measurement kit, suitable for laboratory equipment for radioimmunoassay of Acceptable Range manufacturer recommendation to increase the objectivity of the test results by national and international recognition for radioimmunoassay should seek to increase.

  • PDF

Molecular Method Confirms Canine Leishmania Infection Detected by Serological Methods in Non-Endemic Area of Brazil

  • Riboldi, Emeline;Carvalho, Flavio;Romao, Pedro Roosevelt Torres;Barcellos, Regina Bones;Bello, Graziele Lima;Ramos, Raquel Rocha;de Oliveira, Rosemari Terezinha;Araujo, Joao Pessoa Junior;Rossetti, Maria Lucia;Dallegrave, Eliane
    • Parasites, Hosts and Diseases
    • /
    • 제56권1호
    • /
    • pp.11-19
    • /
    • 2018
  • In Brazil, visceral leishmaniasis (VL) is expanding and becoming urbanized, especially in non-endemic areas such as the State of Rio Grande do Sul. Considering that infected dogs are the main reservoir for zoonotic VL, this study evaluated the prevalence of canine visceral leishmaniasis (CVL) in the metropolitan area of Porto Alegre, a new area of expansion of VL in Brazil. Serum and plasma from 405 asymptomatic dogs from the municipalities of Canoas (n=107), $S\tilde{a}o$ Leopoldo (n=216), and Novo Hamburgo (n=82) were tested for CVL using immunochromatographic ($DPP^{(R)}$) and ELISA $EIE^{(R)}$ assays (2 assays officially adopted by the Brazilian government for the diagnosis of CVL) and real-time PCR to confirm the results. There was no agreement among serological and real-time PCR results, indicating that the Leishmania infection in asymptomatic animals with low parasite load, confirmed by negative parasitological tests (smears and parasite culture), need to be evaluated by molecular methods. The prevalence of LVC in the metropolitan region of Porto Alegre, confirmed by real-time PCR was 4% (5.6% in Canoas and 4.6% in $S\tilde{a}o$ Leopoldo). The use of molecular method is essential for accurate diagnosis of CVL, especially in asymptomatic dogs in non-endemic areas.

THE APPEARENCE OF PROINFLAMMATORY CYTOKINES IN TEMPOROMANDIBULAR JOINT DISORDERS AFTER ARTHROCENTESIS AND LAVAGE (측두하악장애환자에서 악관절 세척술후 관절활액의 전구염증성 Cytokines의 발현)

  • Kim, Cheol-Hun;Hwang, Hie-Sung;Shin, Sang-Hoon;Chung, In-Kyo;Hwang, Tae-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권5호
    • /
    • pp.370-378
    • /
    • 2005
  • The purpose of this study is that evaluate the distribution and biological roles of TNF-a, interleukin-1${\beta}$(IL-1${\beta}$), interleukin-6(IL-6) and tissue inhibitors of metalloproteinase-1(TIMP-1) in the synovial fliud of patients with non-inflammatory chronic temporomandibular joint(TMJ) disorders in relation to pain during joint movements and magnetic resonance imaging(MRI) findings. TMJ synovial fluids aspirates were obtained from 36 patients (36 joints) with chronic TMJ disorders and from 8 controls(8 joints). Patients were divided to four groups. The control group was from healthy volunteers(8 joints), group I(18 joints) was patients with anterior disc displacement with reduction, group II(5 joints) was patients with disc displacement without reduction and group III (5 joints) was osteoarthritis. The TNF-${\alpha}$, IL-1${\beta}$ and IL-6 levels in the aspirates were determined by using an enzyme-linked immunosorbent assay and the TIMP-1 level was measured by an enzyme immunoassay. Following examinations for pain during joint movements and MRI observations, these cytokines' level and frequencies of detection were compared. The level of IL-1${\beta}$was not significant different in all groups. but the level of TNF-${\alpha}$, IL-6 and TIMP-1 were significant different among groups. The level of IL-6 and TIMP-1 were correlated to pain during movement(p<0.01) and the level of TNF-a(p<0.05). Also, the level of IL-6 was correlated to the level of TIMP-1(p<0.01). Especially, The level of the TIMP-1 level was significantly correlated to the pain during movement and showed very high levle of Pearson's correlation coefficient (r=0.833)(p<0.001). The results indicated that the TNF-${\alpha}$, IL-6 and TIMP-1 levels in the TMJ aspirates of patients with chronic TMJ disorders have been raised. Especially, IL-6 and TIMP-1 were very high levels in the patients who were degraded in the TMJ. Also, TNF-${\alpha}$, IL-6 and TIMP-1 showed the significant correlation in the chronic temporomandibular joint disorders. Therefore I suggest that these cytokines were also correlated to the pain during movement in the chronic temporomandibular joint disorders.

The Prevention of Carryover in the Automated System With Fixed Tips (자동 분주기 Fixed Tip의 Carryover 방지를 위한 개선 방안)

  • Hwang, Bo-Ra;Au, Doo-Hee;Bae, Jin-Su;Park, Jong-O;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제13권3호
    • /
    • pp.181-184
    • /
    • 2009
  • Purpose: Automated system that immunoassay examination are used widely. However, sample to sample carryover can cause that the next patient sample is false positive. Materials and Methods: We test HBs Ag, HBs Ab, HBc Ab(IgG) with Automated pipetting system (Tecan). It was placed with very high concentrations followed by saline solution. During this experiment, The fixed tip of Automated system wash With 0.25 moL/L NaOH. The Measurement results of saline solution confirm the occurrence of carryover. Results: Results of saline solution with 0.25 moL/L NaOH cleaning process was measured 100% negative, And results of patient serum with 0.25 moL/L NaOH cleaning process is similar reported results. Conclusion: As Results, 0.25 moL/L NaOH cleaning process was avoid carryover in experiment, And we know results of the hepatitis test did not affected by this solution we recommend 0.25 moL/L NaOH cleaning process as the Prevention of carryover in the automated system with fixed Tips.

  • PDF

Establishment and Application of a Multibead Serotyping Assay for Pneumococci in Korea (다중구슬 폐구균 혈청형 분석법의 국내 확립과 적용 연구)

  • Kim, Han Wool;Lee, Soyoung;Lee, Miae;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • 제22권2호
    • /
    • pp.97-105
    • /
    • 2015
  • Purpose: Serotyping pneumococcal isolates is important to monitor efficacy of pneumococcal vaccines. Because of difficulties of typing pnueumocci, a multiplex bead-based (multibead) serotyping assay was recently introduced. The aim of this study is to establish a new multibead serotyping assay and to apply this method to analyze clinical isolates of pneumococci in Korea. Methods: To establish the multibead serotyping assay, six key reagents were transferred from University of Alabama at Birmingham (UAB) to Ewha Center for Vaccine Evaluation and Study (ECVES): bead set coated with polysaccharide and monoclonal antibody pool were used in one multiplex inhibition-type immunoassay and 2 bead sets coated DNA probe and 2 primer pools were used in two multiplex PCR-based assays. After multibead serotyping assay was set up, 75 test samples of pneumococci were analyzed whether ECVES is able to identify serotype correctly. After confirming the performance, serotyping assay was applied to identify serotypes of 528 clinical isolates of pneumococci collected from 3 different hospitals. Results: After establishment of the multibead pneumococcal serotyping assay system at ECVES, 75 test samples were analyzed. There was no discrepancy of serotypes of 75 test samples between the results assigned at UAB and those at ECVES. The serotypes of 528 pneumococci isolated from patients or healthy subjects were determined in 94.3% of isolates (498/528). Conclusions: The multibead pneumococcal serotyping assay can be successfully established in Korea. With this method, surveillance of serotypes of pneumococci isolated from patients as well as healthy subjects could be studied.

Assessment of Validity of RT-PCR and EIA for The Detection of Hepatitis C Virus Infection (C형 간염의 진단을 위한 역전사중합효소연쇄반응과 효소면역측정법의 타당성 평가)

  • Son, Byung-Chul;Chun, Jin-Ho;Park, Yeong-Hong;Shin, Hai-Rim;Cho, Kyu-Il;Kim, Jong-Han;Jung, Kui-Oak;Lee, Jong-Tae;Lee, Chae-Un;Paik, Nak-Whan
    • Journal of Preventive Medicine and Public Health
    • /
    • 제28권2호
    • /
    • pp.526-541
    • /
    • 1995
  • This study was conducted to estimate the validity of reverse transcriptase-polymerase chain reaction(RT-PCR) compared to enzyme immunoassay(EIA) for the detection of hepatitis C virus (HCV) infection. EIA for antibody to HCV(anti-HCV) and RT-PCR for HCV was executed on the subjects from Pusan and Kyungnam area with questionnaire survey to collect some relating factors of HCV infection. As the result from 617 cases, the prevalence of HCV infection was 1.5% by EIA and 3.7% by RT-PCR(p<0.05), and the age standardized rate was 1.7% and 3.4% by EIA and RT-PCR, respectively. The prevalence of hepatitis B surface antigen(HBsAg) was 6.8% by enzyme linked immunosorbent assay(ELISA) and the age standardized rate was 7.7%. It was the higher in male group comparing to female group(p<0.01). Both of the prevalence of HCV and HBsAg were higher in elevated asparate aminotransferase(AST) and alanine aminotransferase (ALT) group than in normal AST and ALT group(p<0.01). There was no specific risk factor of HCV infection. Though the degree of agreement of EIA and RT-PCR by gamma statistics was 97.2%, it showed a significant difference between the two methods(p<0.01). For the detection of HCV infection, positive predictive value of EIA was 66.7% and negative predictive value of EIA was 97.2%. This study suggests that negative result to anti-HCV by EIA didn't mean the free state of HCV infection, therefore it would be helpful that further monitoring for HCV infection by RT-PCR in the case of elevated AST and ALT and/or clinically suspected.

  • PDF

Production of A Monoclonal Antibody (MAb) Against a Thermal Stable-Soluble Protein in Mackerel and Confirmation of the Properties for the MAb (고등어 어육 중 열안정성 단백질에 특이한 단클론성 항체 개발과 특성 확인)

  • Lee, Jeong-Eun;Kim, Jeong-Sook;Chung, Duck-Hwa;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • 제32권1호
    • /
    • pp.75-81
    • /
    • 2017
  • For people who have a food allergy the only way to manage the allergy is to avoid the food allergen. The mackerel is one of the major food allergens, but no immunoassay for the rapid and simple detection of mackerel has been reported. The objectives of this study are to develop and characterize monoclonal antibodies (MAbs) specific to mackerel using thermal stable-soluble proteins (TSSP) as an immunogen and to characterize the MAbs by indirect enzyme-linked immunosorbent assay (iELISA). The mice immunized with mackerel TSSP and showing high titer were used for cell fusion and cloning. The characterization of MAbs produced from hybridoma cells obtained was confirmed by indirect ELISA and western blot. Four MAbs were confirmed to be specific to mackerel without cross-reaction to other marine products and livestock products in the both methods. The iELISA and western blot based on the MAbs can sensitively detect 1% mackerel protein in other marine products. These results support that immunochemical methods based on the MAb produced could be used as rapid means to detect low levels of mackerel and to identify mackerel adulterated in food.

Thermal Stable Soluble Proteins in Pork Fat and Meat, and Their Antigenicity (돈지육 및 돈육 중 열안정성 단백질의 존재 확인과 이의 항원성 확인)

  • Kim, Jeong-Sook;Lee, Jeong-Eun;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • 제31권6호
    • /
    • pp.445-450
    • /
    • 2016
  • Thermal-stable soluble proteins (TSSP) in livestock products has been recently reported. Therefore, the development of antibodies and immunoassay using a TSSP is useful because the presence of TSSP can be measured on processed food. In this study, the existence of TSSPs in pork fat and meat was confirmed and their antigenicity was investigated. The extracts from pork fat and meat by heating method were analyzed by SDS-PAGE with 5% stacking and 12% separating gels. The protein profiles from the raw pork fat and meat extracts (major band ranged 25 to 100 kDa) without cooking and heating treatments were significantly different compared to those from cooked and heated pork fat and meat extracts (several major bands > 100 kDa and < 30 kDa). This meant that non thermal-stable soluble proteins ranged from 25 to 100 kDa may be denaturated to insoluble proteins by cooking and heating treatments, and TSSPs were in pork fat and meat at kept their properties. The confirmed TSSPs were used as an immunogen to investigate their antigenicity. Eight mice (5 mice for pork fat and 3 mice for pork meat) were separately immunized with the TSSPs of pork fat and meat, and the anti-sera obtained from the immunized mice showed high titer values. Polyclonal antibodies against each target protein showed the specific reaction to pork fat and meat, individually. These indicated that TSSP could be used as an immunogen to produce antibodies such as monoclonal and polyclonal antibodies. In addition, antibodies specific to TSSP from pork fat and meat may be used as a bio-receptor in immunoassays for the identification of fraudulent adulteration with pork fat and meat in livestock products.