Guideline for Imaging Dose on Image-Guided Radiation Therapy (영상유도방사선치료에 있어 영상선량 가이드라인)

  • Cho, Byung Chul;Huh, Hyun Do;Kim, Jin Sung;Choi, Jin Ho;Kim, Seong Hoon;Cho, Kwang Hwan;Cho, Sam Ju;Min, Chul Kee;Shin, Dong Oh;Lee, Sang Hoon;Park, Dong Wook;Kim, Kum Bae;Choi, Sang Hyoun;Kim, Hye Young;Ahn, Woo-Sang;Kim, Tae Hyeong;Han, Su Cheol
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.1-24
    • /
    • 2013
  • As image-guided radiation therapy (IGRT) has been commonly used for more accurate patient setup and monitoring tumor movement during radiation therapy, the necessity for management of imaging dose is increased. However, it has not been an interest issue to radiation therapy communities because the imaging dose is much lower than the therapeutic dose. However, since the cumulative dose from 4DCT and repeated imaging for daily setup verificationin would not be ignorable, appropriate dose management based on ALARA (As Low As Reasonably Achievable) principle is required. In this study, we aimed that (1) survey on imaging equipments and modalities used for IGRT, (2) estimation of IGRT imaging dose depending on treatment types and equipments, (3) collecting data of effective dose on treatment sites from each equipment and imaging protocol, and thus finally provide guideline for imaging dose reduction and optimization.

Phantom-Validated Reference Values of Myocardial Mapping and Extracellular Volume at 3T in Healthy Koreans

  • Lee, Eunjin;Kim, Pan Ki;Choi, Byoung Wook;Jung, Jung Im
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.141-153
    • /
    • 2020
  • Purpose: Myocardial T1 and T2 relaxation times are affected by technical factors such as cardiovascular magnetic resonance platform/vendor. We aimed to validate T1 and T2 mapping sequences using a phantom; establish reference T1, T2, and extracellular volume (ECV) measurements using two sequences at 3T in normal Koreans; and compare the protocols and evaluate the differences from previously reported measurements. Materials and Methods: Eleven healthy subjects underwent cardiac magnetic resonance imaging (MRI) using 3T MRI equipment (Verio, Siemens, Erlangen, Germany). We did phantom validation before volunteer scanning: T1 mapping with modified look locker inversion recovery (MOLLI) with 5(3)3 and 4(1)3(1)2 sequences, and T2 mapping with gradient echo (GRE) and TrueFISP sequences. We did T1 and T2 mappings on the volunteers with the same sequences. ECV was also calculated with both sequences after gadolinium enhancement. Results: The phantom study showed no significant differences from the gold standard T1 and T2 values in either sequence. Pre-contrast T1 relaxation times of the 4(1)3(1)2 protocol was 1142.27 ± 36.64 ms and of the 5(3)3 was 1266.03 ± 32.86 ms on the volunteer study. T2 relaxation times of GRE were 40.09 ± 2.45 ms and T2 relaxation times of TrueFISP were 38.20 ± 1.64 ms in each. ECV calculation was 24.42% ± 2.41% and 26.11% ± 2.39% in the 4(1)3(1)2 and 5(3)3 protocols, respectively, and showed no differences at any segment or slice between the sequences. We also calculated ECV from the pre-enhancement T1 relaxation time of MOLLI 5(3)3 and the post-enhancement T1 relaxation time of MOLLI 4(1)3(1)2, with no significant differences between the combinations. Conclusion: Using phantom-validated sequences, we reported the normal myocardial T1, T2, and ECV reference values of healthy Koreans at 3T. There were no statistically significant differences between the sequences, although it has limited statistical value due to the small number of subjects studied. ECV showed no significant differences between calculations based on various pre- and post-mapping combinations.

Diagnostic Performance of Simulated Abbreviated MRI for Early-Stage Hepatocellular Carcinoma Screening: A Comparison to Conventional Dynamic Contrast-Enhanced MRI (초기 간암 선별 검사로서 단축 자기공명영상 검사의 진단능: 고식적 역동학적 자기공명영상검사와의 비교)

  • Eun Sol Lim;Sung Mo Kim;Sang Soo Shin;Suk Hee Heo;Jong Eun Lee;Yong Yeon Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1218-1230
    • /
    • 2021
  • Purpose To compare the per-patient diagnostic performance of simulated abbreviated MRI (AMRI) to that of conventional MRI (CMRI) with full-sequence dynamic gadoxetic acid (GA) enhancement for early-stage hepatocellular carcinoma (HCC) screening in high-risk patients. Materials and Methods A total of 201 consecutive patients at high-risk for HCC, who underwent 3T liver MRI, were included in this retrospective study. The AMRI protocol comprised T2-weighted imaging, hepatobiliary phase imaging after GA injection, and diffusion-weighted imaging. For each patient, two AMRI and CMRI image sets were independently reviewed by two radiologists. Inter-reader agreement was assessed using Cohen's kappa value. A composite reference standard was used to determine the diagnostic performance of each image set for each reader. Results A total of 93 HCCs were detected in 79 patients. The inter-reader agreement was almost perfect for both image sets (κ = 0.839, 0.948). In AMRI, the per-patient sensitivity and negative predictive values (NPV) were 94.9% and 96.4%, respectively. In CMRI, the per-patient sensitivity and NPV were 96.2% and 97.5%, respectively. Conclusion AMRI, using only three sequences, had a comparable diagnostic performance to CMRI in screening early-stage HCC. AMRI could be an alternative HCC screening tool for high-risk HCC patients.

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

CNS Relapsed T-cell Lymphoma in a Young Cat (어린 고양이에서 발생한 중추신경계로 재발한 T세포 림프종)

  • Seo, Kyoung-Won;Oh, Ye-In;Han, Sei-Myoung;Go, Du-Min;Lee, Jeong-Ha;Youn, Hwa-Young
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.226-232
    • /
    • 2014
  • An 8-month-old domestic shorthair cat presented with decreased activity and anorexia. Diagnostic imaging revealed cranial mediastinal mass and enlarged mesenteric lymph nodes. Fine needle aspirates showed a marked increase in malignant lymphocytes. Multicentric lymphoma (stage V-b) was diagnosed. The cat treated with COP protocol chemotherapy, and complete remission was induced. CNS relapse developed 314 days after the initiation of chemotherapy. Treatment with rescue protocol greatly reduced the clinical signs for a short period. The cat was in partial remission for 33 days and overall survival time was 383 days. Multicentric T-cell lymphoma with brain involvement was confirmed after necropsy by histopathology and immunohistochemistry.

Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density

  • Gaeta-Araujo, Hugo;Nascimento, Eduarda Helena Leandro;Brasil, Danieli Moura;Madlum, Daniela Verardi;Haiter-Neto, Francisco;Oliveira-Santos, Christiano
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.153-159
    • /
    • 2020
  • Purpose: This study was conducted evaluate the influence of reconstruction parameters of micro-computed tomography (micro-CT) images on bone mineral density (BMD) analyses. Materials and Methods: The sample consisted of micro-CT images of the maxillae of 5 Wistar rats, acquired using a SkyScan 1174 unit (Bruker, Kontich, Belgium). Each acquisition was reconstructed following the manufacturer's recommendations(standard protocol; SP) for the application of artifact correction tools(beam hardening correction [BHC], 45%; smoothing filter, degree 2; and ring artifact correction [RAC], level 5). Additionally, images were reconstructed with 36 protocols combining different settings of artifact correction tools (P0 to P35). BMD analysis was performed for each reconstructed image. The BMD values obtained for each protocol were compared to those obtained using the SP through repeated-measures analysis of variance with the Dunnett post hoc test(α=0.05). Results: The BMD values obtained from all protocols that used a BHC of 45% did not significantly differ from those obtained using the SP (P>0.05). The other protocols all yielded significantly different BMD values from the SP(P<0.05). The smoothing and RAC tools did not affect BMD values. Conclusion: BMD values measured on micro-CT images were influenced by the BHC level. Higher levels of BHC induced higher values of BMD.

Clinical Results of Neo-Adjuvant Chemotherapy and Surgery on Osteosarcoma (Stage II B형 골육종에 대한 술전 항암화학요법 및 수술적 치료 결과)

  • Kang, Yong-Koo;Kim, Hyung-Min;Rhee, Seung-Koo;Woo, Young-Kyun;Kim, Jung-Man;Kim, Hoon-Kyo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.27-32
    • /
    • 1996
  • Recent advances in imaging techniques, surgery and combination anti-cancer chemotherapy have brought high survival rates in osteosarcoma. To investigate the survival rate, local recurrence and complications in treatment, we analysed 25 osteosarcoma cases who had been treated with preoperative neo-adjuvant chemotherapy, surgery and post operative chemotherapy at Department of Orthopedic Surgery, Catholic University. From May 1988 to April 1995, 42 cases of stage IIB osteosarcoma were admitted in Department of Orthopedic Surgery. Among them, 17 cases who didn't follow our treatment guidance were excluded in this study. The average age were 19 years. There were 21 males and 4 females. The involved sites were 4 humerus, 10 femur, 10 tibia and 1 talus. Eleven cases had received intraarterial cisplatin and intravenous adriamycin chemotherapy, and 7 T-10 protocol and 7 intravenous ifosfamide, ADR, methotrexate, cisplatin. Twenty-three cases were treated with limb salvage surgery, and 2 amputation. The average follow-up was 35 months(3~82). There were 14 cases of continuous disease free, 9 cases of died of disease, 1 case of alive with disease, and 1 case of no evidence of disease at final follow-up. There were three cases of local recurrence at 6,8 and 12 months after operation. The estimated Kaplan-Meier's 5 year survival rates for all, ADR-cisplatin group, T-10 protocol group, and ifosfamide regimen group were 6%, 73%, 44% and 72%, respectively.

  • PDF

Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction (뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구)

  • Lee, Jae-Seung;Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.

The Reliability of Thickness Measurement of the Deep Fiber of the Lumbar Multifidus Using Ultrasonography

  • Jung, Doh-Heon;Kim, Su-Jung;Yi, Chung-Hwi;Cynn, Heon-Seock;Choi, Houng-Sik
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.49-54
    • /
    • 2010
  • The reliability of the thickness measurement of the lumbar multifidus (LMD using real-time ultrasonography (US) was determined in only the superficial fiber of the lumbar multifidus (SM). However, previous studies have not examined the reliability of the deep fiber of the LM (DM). The purpose of this study was to determine the intrarater and the interrater reliability of the thickness measurements of DM using US. Eleven heathy males participated in the study. The thickness of the DM was measured with an US in the prone position. Reliability was examined using intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and the Bland and Altman plot. ICC(3,1) was used to calculate the interrater reliability of the thickness measurement of DM using the values from both the first and second test sessions. Additionally, ICC(3,1) was used to calculate the intrarater reliability of the measurements over two days using the measurements obtained in test session 1 and lest session 2. The results of this study were as follows: 1) the ICC(3,1) value for interrater reliability was .94 in the first test session, and .93 in the second test session. 2) the ICC(3,1) values for intrarater reliability of the measurements over two days was .90 in both the first examiner and the second examiner. The interrater reliability and interrater reliability of the DM measurements, obtained via the US protocol used in this research was excellent. Therefore, we conclude that the thickness measurement of the DM obtaioned from the US protocol used in this research would be useful for clinician assessment of the thickness of the DM.