• Title/Summary/Keyword: imaging methods

Search Result 4,627, Processing Time 0.029 seconds

Evaluation of Post-Neoadjuvant Chemotherapy Pathologic Complete Response and Residual Tumor Size of Breast Cancer: Analysis on Accuracy of MRI and Affecting Factors (신보강화학요법 후 유방암의 병리학적 완전 관해 예측 및 잔류 암 평가: 유방자기공명영상의 정확도 및 영향인자 분석)

  • Hyun Soo Ahn;Yeong Yi An;Ye Won Jeon;Young Jin Suh;Hyun-Joo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.654-669
    • /
    • 2021
  • Purpose To evaluate the accuracy of MRI in predicting the pathological complete response (pCR) and the residual tumor size of breast cancer after neoadjucant chemotherapy (NAC), and to determine the factors affecting the accuarcy. Materials and Methods Eighty-eight breast cancer patients who underwent surgery after NAC at our center between 2010 and 2017 were included in this study. pCR was defined as the absence of invasive cancer on pathological evaluation. The maximum diameter of the residual tumor on post-NAC MRI was compared with the tumor size of the surgical specimen measured pathologically. Statistical analysis was performed to elucidate the factors affecting pCR and the residual tumor size-discrepancy between the MRI and the pathological measurements. Results The pCR rate was 10%. The diagnostic accuracy of MRI and the area under the curve for predicting pCR were 90.91% and 0.8017, respectively. The residual tumor sizes obtained using MRI and pathological measurements showed a strong correlation (r = 0.9, p < 0.001), especially in patients with a single mass lesion (p = 0.047). The size discrepancy between MRI and the pathological measurements was significantly greater in patients with the luminal type (p = 0.023) and multifocal tumors/non-mass enhancement on pre-NAC MRI (p = 0.047). Conclusion MRI is an accurate tool for evaluating pCR and residual tumor size in breast cancer patients who receive NAC. Tumor subtype and initial MRI features affect the accuracy of MRI.

Safety and Efficacy of Ultrasound-Guided Percutaneous Core Needle Biopsy of Pancreatic and Peripancreatic Lesions Adjacent to Critical Vessels (주요 혈관 근처의 췌장 또는 췌장 주위 병변에 대한 초음파 유도하 경피적 중심 바늘 생검의 안전성과 효율성)

  • Sun Hwa Chung;Hyun Ji Kang;Hyo Jeong Lee;Jin Sil Kim;Jeong Kyong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1207-1217
    • /
    • 2021
  • Purpose To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy (USPCB) of pancreatic and peripancreatic lesions adjacent to critical vessels. Materials and Methods Data were collected retrospectively from 162 patients who underwent USPCB of the pancreas (n = 98), the peripancreatic area adjacent to the portal vein, the paraaortic area adjacent to pancreatic uncinate (n = 34), and lesions on the third duodenal portion (n = 30) during a 10-year period. An automated biopsy gun with an 18-gauge needle was used for biopsies under US guidance. The USPCB results were compared with those of the final follow-up imaging performed postoperatively. The diagnostic accuracy and major complication rate of the USPCB were calculated. Multiple factors were evaluated for the prediction of successful biopsies using univariate and multivariate analyses. Results The histopathologic diagnosis from USPCB was correct in 149 (92%) patients. The major complication rate was 3%. Four cases of mesenteric hematomas and one intramural hematoma of the duodenum occurred during the study period. The following factors were significantly associated with successful biopsies: a transmesenteric biopsy route rather than a transgastric or transenteric route; good visualization of targets; and evaluation of the entire US pathway. In addition, the number of biopsies required was less when the biopsy was successful. Conclusion USPCB demonstrated high diagnostic accuracy and a low complication rate for the histopathologic diagnosis of pancreatic and peripancreatic lesions adjacent to critical vessels.

Light-Chain Cardiac Amyloidosis: Cardiac Magnetic Resonance for Assessing Response to Chemotherapy

  • Yubo Guo;Xiao Li;Yajuan Gao;Kaini Shen;Lu Lin;Jian Wang;Jian Cao;Zhuoli Zhang;Ke Wan;Xi Yang Zhou;Yucheng Chen;Long Jiang Zhang;Jian Li;Yining Wang
    • Korean Journal of Radiology
    • /
    • v.25 no.5
    • /
    • pp.426-437
    • /
    • 2024
  • Objective: Cardiac magnetic resonance (CMR) is a diagnostic tool that provides precise and reproducible information about cardiac structure, function, and tissue characterization, aiding in the monitoring of chemotherapy response in patients with light-chain cardiac amyloidosis (AL-CA). This study aimed to evaluate the feasibility of CMR in monitoring responses to chemotherapy in patients with AL-CA. Materials and Methods: In this prospective study, we enrolled 111 patients with AL-CA (50.5% male; median age, 54 [interquartile range, 49-63] years). Patients underwent longitudinal monitoring using biomarkers and CMR imaging. At follow-up after chemotherapy, patients were categorized into superior and inferior response groups based on their hematological and cardiac laboratory responses to chemotherapy. Changes in CMR findings across therapies and differences between response groups were analyzed. Results: Following chemotherapy (before vs. after), there were significant increases in myocardial T2 (43.6 ± 3.5 ms vs. 44.6 ± 4.1 ms; P = 0.008), recovery in right ventricular (RV) longitudinal strain (median of -9.6% vs. -11.7%; P = 0.031), and decrease in RV extracellular volume fraction (ECV) (median of 53.9% vs. 51.6%; P = 0.048). These changes were more pronounced in the superior-response group. Patients with superior cardiac laboratory response showed significantly greater reductions in RV ECV (-2.9% [interquartile range, -8.7%-1.1%] vs. 1.7% [-5.5%-7.1%]; P = 0.017) and left ventricular ECV (-2.0% [-6.0%-1.3%] vs. 2.0% [-3.0%-5.0%]; P = 0.01) compared with those with inferior response. Conclusion: Cardiac amyloid deposition can regress following chemotherapy in patients with AL-CA, particularly showing more prominent regression, possibly earlier, in the RV. CMR emerges as an effective tool for monitoring associated tissue characteristics and ventricular functional recovery in patients with AL-CA undergoing chemotherapy, thereby supporting its utility in treatment response assessment.

Generative Adversarial Network-Based Image Conversion Among Different Computed Tomography Protocols and Vendors: Effects on Accuracy and Variability in Quantifying Regional Disease Patterns of Interstitial Lung Disease

  • Hye Jeon Hwang;Hyunjong Kim;Joon Beom Seo;Jong Chul Ye;Gyutaek Oh;Sang Min Lee;Ryoungwoo Jang;Jihye Yun;Namkug Kim;Hee Jun Park;Ho Yun Lee;Soon Ho Yoon;Kyung Eun Shin;Jae Wook Lee;Woocheol Kwon;Joo Sung Sun;Seulgi You;Myung Hee Chung;Bo Mi Gil;Jae-Kwang Lim;Youkyung Lee;Su Jin Hong;Yo Won Choi
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.807-820
    • /
    • 2023
  • Objective: To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software. Materials and Methods: This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1-7 according to acquisition conditions. CT images in groups 2-7 were converted into the target CT style (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system. Results: Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2-7 improved after CT conversion (original vs. converted: 0.63 vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists' scores were significantly higher (P < 0.001) and less variable on converted CT. Conclusion: CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.

Usefulness of 18F-FDG PET/CT and Multiphase CT in the Differential Diagnosis of Hepatocellular Carcinoma and Combined Hepatocellular Carcinoma-Cholangiocarcinoma (간세포암종과 혼합성 간세포암종-담관암종에서 다위상 전산단층촬영술 소견과 18F-FDG PET/CT에서 섭취율 차이에 대한 분석 )

  • Jae Chun Park; Jung Gu Park;Gyoo-Sik Jung;Hee Kang;Sungmin Jun
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1424-1435
    • /
    • 2020
  • Purpose The purpose of this study was to evaluate the usefulness of multiphasic CT and 18F-fluorodeoxyglucose (FDG) PET/CT for the differentiation of combined hepatocellular carcinoma-cholangiocarcinoma (cHCC-CCA) from hepatocellular carcinoma (HCC). Materials and Methods From January 2007 to April 2016, 93 patients with pathologically confirmed HCC (n = 84) or cHCC-CCA (n = 9) underwent CT and PET/CT imaging. Contrast enhancement patterns were divided into three types based on the attenuation of the surrounding liver parenchyma: type I (early arterial enhancement with delayed washout), type II (early arterial enhancement without delayed washout), and type III (early hypovascular, infiltrative appearance, or peripheral rim enhancement). Results cHCC-CCAs (89%) had a higher PET/CT positive rate than did HCCs (61%), but the PET/CT positive rate did not differ significantly (p = 0.095). Among the 19 cases of the type II enhancement pattern, 3 (21%) of 14 HCCs and 4 (80%) of 5 cHCC-CCAs were PET/CT positive. cHCC-CCAs had a significantly higher PET/CT positive rate (p = 0.020) in the type II enhancement pattern. Conclusion The PET/CT positive rate of cHCC-CCA was significantly higher than that of HCC in lesions with a type II enhancement pattern. The 18F-FDG PET/CT can be useful for the differentiation of cHCC-CCA from HCC in lesions with a type II enhancement pattern on multiphasic CT.

Usefulness of Corticomedullary-Phase CT Urography in Patients with Suspected Acute Renal Colic Visiting the Emergency Department (응급실을 방문하는 급성신산통이 의심되는 환자에서 요로조영술 컴퓨터단층촬영의 피질-수질기의 유용성)

  • Seokyoung Lee;Yang Shin Park;Bitna Park;Jongmee Lee;Jae Woong Choi;Kyeong Ah Kim;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.923-933
    • /
    • 2023
  • Purpose To evaluate the sensitivity of corticomedullary-phase imaging for detecting urinary stones in patients with renal colic who visited the emergency department. Materials and Methods This retrospective study included 253 patients with suspected renal colic from two tertiary hospitals in South Korea, who visited the emergency department and underwent CT urography. Two radiologists blinded to the clinical history independently reviewed the corticomedullary-phase images. The sensitivity for identifying urinary stones were evaluated for each reviewer. After the initial evaluation, the images were re-evaluated based on patient history. The sensitivity of re-evaluation were recorded. Results Of 253 patients, 150 (59%) had urinary stones. Among them, significant stones were observed in 138 patients (92%), and obstructive changes on CT in 124 patients (82.7%). For identifying significant urinary stones, the sensitivity was 98.6% (136/138) for both the reviewers. For identifying significant urinary stones with urinary obstruction, the sensitivity was 99.2% (123/124) for reviewer 1, and 100% (124/124) for reviewer 2. The sensitivity for identifying significant stones increased from 98.6% to 100% for reviewer 1, and from 98.6% to 99.3% for reviewer 2 in the re-evaluation session. Conclusion The corticomedullary-phase CT urography was sensitive for diagnosing urolithiasis in patients with acute renal colic who visited the emergency department.

CT-Derived Deep Learning-Based Quantification of Body Composition Associated with Disease Severity in Chronic Obstructive Pulmonary Disease (CT 기반 딥러닝을 이용한 만성 폐쇄성 폐질환의 체성분 정량화와 질병 중증도)

  • Jae Eun Song;So Hyeon Bak;Myoung-Nam Lim;Eun Ju Lee;Yoon Ki Cha;Hyun Jung Yoon;Woo Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1123-1133
    • /
    • 2023
  • Purpose Our study aimed to evaluate the association between automated quantified body composition on CT and pulmonary function or quantitative lung features in patients with chronic obstructive pulmonary disease (COPD). Materials and Methods A total of 290 patients with COPD were enrolled in this study. The volume of muscle and subcutaneous fat, area of muscle and subcutaneous fat at T12, and bone attenuation at T12 were obtained from chest CT using a deep learning-based body segmentation algorithm. Parametric response mapping-derived emphysema (PRMemph), PRM-derived functional small airway disease (PRMfSAD), and airway wall thickness (AWT)-Pi10 were quantitatively assessed. The association between body composition and outcomes was evaluated using Pearson's correlation analysis. Results The volume and area of muscle and subcutaneous fat were negatively associated with PRMemph and PRMfSAD (p < 0.05). Bone density at T12 was negatively associated with PRMemph (r = -0.1828, p = 0.002). The volume and area of subcutaneous fat and bone density at T12 were positively correlated with AWT-Pi10 (r = 0.1287, p = 0.030; r = 0.1668, p = 0.005; r = 0.1279, p = 0.031). However, muscle volume was negatively correlated with the AWT-Pi10 (r = -0.1966, p = 0.001). Muscle volume was significantly associated with pulmonary function (p < 0.001). Conclusion Body composition, automatically assessed using chest CT, is associated with the phenotype and severity of COPD.

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

Computer-Aided Diagnosis Parameters of Invasive Carcinoma of No Special Type on 3T MRI: Correlation with Pathologic Immunohistochemical Markers (3T 자기공명영상에서 비특이 침윤성 유방암의 컴퓨터보조진단 인자들과 병리적 면역조직화학 표지자들과의 상관성)

  • Jinho Jeong;Chang Suk Park;Jung Whee Lee;Kijun Kim;Hyeon Sook Kim;Sun-Young Jun;Se-Jeong Oh
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.149-161
    • /
    • 2022
  • Purpose To investigate the correlation between computer-aided diagnosis (CAD) parameters in 3-tesla (T) MRI and pathologic immunohistochemical (IHC) markers in invasive carcinoma of no special type (NST). Materials and Methods A total of 94 female who were diagnosed with NST carcinoma and underwent 3T MRI using CAD, from January 2018 to April 2019, were included. The relationship between angiovolume, curve peak, and early and late profiles of dynamic enhancement from CAD with pathologic IHC markers and molecular subtypes were retrospectively investigated using Dwass, Steel, Critchlow-Fligner multiple comparison analysis, and univariate binary logistic regression analysis. Results In NST carcinoma, a higher angiovolume was observed in tumors of higher nuclear and histologic grades and in lymph node (LN) (+), estrogen receptor (ER) (-), progesterone receptor (PR) (-), human epidermal growth factor 2 (HER2) (+), and Ki-67 (+) tumors. A high rate of delayed washout and a low rate of delayed persistence were observed in Ki-67 (+) tumors. In the binary logistic regression analysis of NST carcinoma, a high angiovolume was significantly associated with a high nuclear and histologic grade, LN (+), ER (-), PR (-), HER2 (+) status, and non-luminal subtypes. A high rate of washout and a low rate of persistence were also significantly correlated with the Ki-67 (+) status. Conclusion Angiovolume and delayed washout/persistent rate from CAD parameters in contrast enhanced breast MRI correlated with predictive IHC markers. These results suggest that CAD parameters could be used as clinical prognostic, predictive factors.

The Usefulness of 18F-FDG PET to Differentiate Subtypes of Dementia: The Systematic Review and Meta-Analysis

  • Seunghee Na;Dong Woo Kang;Geon Ha Kim;Ko Woon Kim;Yeshin Kim;Hee-Jin Kim;Kee Hyung Park;Young Ho Park;Gihwan Byeon;Jeewon Suh;Joon Hyun Shin;YongSoo Shim;YoungSoon Yang;Yoo Hyun Um;Seong-il Oh;Sheng-Min Wang;Bora Yoon;Hai-Jeon Yoon;Sun Min Lee;Juyoun Lee;Jin San Lee;Hak Young Rhee;Jae-Sung Lim;Young Hee Jung;Juhee Chin;Yun Jeong Hong;Hyemin Jang;Hongyoon Choi;Miyoung Choi;Jae-Won Jang;Korean Dementia Association
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.1
    • /
    • pp.54-66
    • /
    • 2024
  • Background and Purpose: Dementia subtypes, including Alzheimer's dementia (AD), dementia with Lewy bodies (DLB), and frontotemporal dementia (FTD), pose diagnostic challenges. This review examines the effectiveness of 18F-Fluorodeoxyglucose Positron Emission Tomography (18F-FDG PET) in differentiating these subtypes for precise treatment and management. Methods: A systematic review following Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines was conducted using databases like PubMed and Embase to identify studies on the diagnostic utility of 18F-FDG PET in dementia. The search included studies up to November 16, 2022, focusing on peer-reviewed journals and applying the goldstandard clinical diagnosis for dementia subtypes. Results: From 12,815 articles, 14 were selected for final analysis. For AD versus FTD, the sensitivity was 0.96 (95% confidence interval [CI], 0.88-0.98) and specificity was 0.84 (95% CI, 0.70-0.92). In the case of AD versus DLB, 18F-FDG PET showed a sensitivity of 0.93 (95% CI 0.88-0.98) and specificity of 0.92 (95% CI, 0.70-0.92). Lastly, when differentiating AD from non-AD dementias, the sensitivity was 0.86 (95% CI, 0.80-0.91) and the specificity was 0.88 (95% CI, 0.80-0.91). The studies mostly used case-control designs with visual and quantitative assessments. Conclusions: 18F-FDG PET exhibits high sensitivity and specificity in differentiating dementia subtypes, particularly AD, FTD, and DLB. This method, while not a standalone diagnostic tool, significantly enhances diagnostic accuracy in uncertain cases, complementing clinical assessments and structural imaging.