• 제목/요약/키워드: imaging material

검색결과 579건 처리시간 0.024초

Dip-pen nanolithography를 위한 이중 팁을 가진 질화규소 프로브의 설계 및 제조 (Design and Fabrication of Dual Tip Si3N4 Probe for Dip-pen Nanolithograpy)

  • 김경호;한윤수
    • 한국표면공학회지
    • /
    • 제47권6호
    • /
    • pp.362-367
    • /
    • 2014
  • We report the design, fabrication of a $Si_3N_4$ probe and calculation of its mechanical properties for DPN(dip pen nanolithography), which consists of dual tips. Concept of dual tip probe is to employ individual tips on probe as either an AFM tip for imaging or a writing tip for nano patterning. For this, the dual tip probe is fabricated using low residual stress $Si_3N_4$ material with LPCVD deposition and MEMS fabrication process. On the basis of FEM analysis we show that the functionality of dual tip probe for imaging is dependent on the dimensions of dual tip probe, and high ratio of widths of beam areas is preferred to minimize curvature variation on probe.

초분광영상의 조명효과 보정 전처리기법 분석 (Analyzing Preprocessing for Correcting Lighting Effects in Hyperspectral Images)

  • 송영선
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.785-792
    • /
    • 2023
  • Because hyperspectral imaging provides detailed spectral information across a broad range of wavelengths, it can be utilized in numerous applications, including environmental monitoring, food quality inspection, medical diagnosis, material identification, art authentication, and crime scene analysis. However, hyperspectral images often contain various types of distortions due to the environmental conditions during image acquisition, which necessitates the proper removal of these distortions through a data preprocessing process. In this study, a preprocessing method was investigated to effectively correct the distortion caused by artificial light sources used in indoor hyperspectral imaging. For this purpose, a halogen-tungsten artificial light source was installed indoors, and hyperspectral images were acquired. The acquired images were then corrected for distortion using a preprocessing that does not require complex auxiliary equipment. After the corrections were made, the results were analyzed. According to the analysis, a statistical transformation technique using mean and standard deviation with reference to a reference signal was found to be the most effective in correcting distortions caused by artificial light sources.

디지털 X-선 변환물질 a-Se:As의 수송변수 (Transport parameters in a-Se:As films for digital X-ray conversion material)

  • 박창희
    • 대한디지털의료영상학회논문지
    • /
    • 제8권1호
    • /
    • pp.51-55
    • /
    • 2006
  • moving photocarrier grating(MPG)기술을 이용하여 디지털 X-선 변환물질 a-Se:As 필름에서 As 첨가효과에 관하여 연구하였다. 이 방법은 시료를 조사하기 위하여 주파수를 변화시킨 2개 레이저 빔의 중첩으로 얻어진 움직이는 간섭패턴을 이용한다. 시료의 수송변수는 시료에서 변조 방향으로 유도되는 grating-속도에 의존하는 전류밀도로부터 얻어진다. As 첨가에 따른 a-Se 필름의 전자와 정공 이동도 그리고 재결합 수명을 구하였다. 전자의 이동도는 결함 상태 때문에 As 첨가에 따라 감소하는 반면, 특히 a-Se 필름에 0.3% As 첨가할 때 정공 이동도와 재결합 수명이 증가하였다. MPG 기술로 얻은 As가 첨가된 a-Se 필름의 수송성질을 a-Se:As로 제작한 X-선 detector의 X-선 감도와 비교하였다. 실험결과 0.3% As가 첨가된 a-Se으로 제작한 X-선detector가 가장 우수한 X-선 감도를 나타내었다.

  • PDF

$CaWO_4/a-Se$ 구조의 X선 변환센서에서 a-Se의 Arsenic 첨가량에 따른 반응 특성 (The Response Characteristics of as Addition Ratio of Arsenic in $CaWO_4/a-Se$ based X-ray Conversion Sensor)

  • 강상식;석대우;조성호;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.416-419
    • /
    • 2002
  • There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. The one is using amorphous selenium as photoconductor and the other is using phosphor layer as a light conversion. But each two systems have strength and weakness such as high voltage and blurring effect. In this study, we investigated the electrical characteristic of $multi-layer\left(CaWO_{4}+a-Se \right)$ as a photoconductor according to the changing arsenic composition ratio. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. The arsenic composition ratio of a-Se compound is classified into 7 different kinds which have 0.1%, 0.3%, 0.5%, 1%, 1.5%, 5%, 10% and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 0.3% arsenic showed good characteristic of $2.45nA/cm^2$ dark current and $357.19pC/cm^2/mR$ net charge at $3V/{\mu}m$.

  • PDF

$Gd_2O_2S(Eu^{2+} )/a$-Se$ 구조의 X선 검출 센서에서 $a-Se_{1-x}As_x$의 검출효율 비교 (Comparison of the Detection Efficiency $a-Se_{1-x}As_x$ in X-ray Detection Sensor of $Gd_2O_2S(Eu^{2+})/a$-Se Structure)

  • 강상식;박지군;이동길;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.436-439
    • /
    • 2002
  • Recently, It has performed that the basic research of the photoconductive material and the development and application of the digital radiograph detector which is divided into the direct and indirect method. The objective of this study investigate the effect of the electric characteristic about changing the composition of Arsenic in hybrid detector system for compensating a defect of conventional. We fabricated samples using the amorphous Selenium and Arsenic alloy with various concentrations of the Arsenic{seven step 0.1%, 0.3%, 0.5%, 1%, 1.5%, 3%, 5%). And using EFIRON optical adhesives the formed multi-layer$(Gd_{2}O_{2}S(Eu^{2+}))$ composed phosphor layer. X-ray and light sensitivity was measured to study x-ray response characteritics. As results, highest value was measured as output net charge and SNR were $315.7pC/cm^2/mR$ and 99.4 at 0.3%As doping ratio.

  • PDF

Mercuric iodide 기반의 디지털 X-선 검출기의 특성 연구 (Characterization studies of digital x-ray detector based on mercuric iodide)

  • 조성호;박지군;최장용;석대우;차병열;남상회;이범종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.392-395
    • /
    • 2003
  • For the purpose of digital x-ray imaging, many materials such as $PbI_2$, $HgI_2$, TlBr, CdTe and CdZnTe have been under development for servaral years as direct converter layer. $Hgl_2$ film detector have recently been shown as one of the most promising semiconductor materials to be used as direct converters in x-ray digital radiography. This paper, the $HgI_2$ films are deposited on conductive-coated glass by screen printing, in which $HgI_2$ powder is embedded in a binder and solvent, and the slurry is used to coat the conductive-coated glass. We investigated electrical characteristic of the fabricated $HgI_2$ films. The x-ray response to radiological x-ray generator of 70Kvp using the current integration mode will be reported for screen printing films. These results indicate that $HgI_2$ detectors have high potential as new digital x-ray imaging devices for radiography.

  • PDF

이중 에너지 검출기를 이용한 영상 시스템 (Image System Using Dual Energy Detector)

  • 여화연
    • 한국산학기술학회논문지
    • /
    • 제11권9호
    • /
    • pp.3517-3523
    • /
    • 2010
  • 본 논문은 이중 에너지 DR(Digital Radiography) 방식 중, 단일 조사 X-선(single shot X-ray exposure) 장치와 이중 모드 검출기 모듈 (Low Energy Detector & High Energy Detector)을 이용한 이중 X-선 이미징이 가능한 검출기 모듈에 관한 연구이다. 상용 BIS(baggage inspection system)에서 사용되고 있는 X-선 발생장치의 스펙트럼과 이중 모드 검출기에 대한 특징 및 방사선적 특성을 분석하여 새롭게 제안 할 검출기 모듈의 최적 설계 방향을 기술하고 상용화된 용화된 LED 및 HED 검출기와 새롭게 제안 한 검출기 모듈에 대해 전기적, 광학적, 방사선적 특성 실험을 실시하여, 새롭게 제안된 검출기 모듈이 BIS 용도로 사용 가능함을 증명하였다. 새롭게 제안 된 검출기 모듈이 적용된 BIS에 대해, 기본 특성 실험에 대한 X-선 영상을 획득하여 실험 및 분석을 실시하였다.

Contribution of Scattered X Rays to Signal Imaging with Anti-scatter Grids

  • Maeda, Koji;Arimura, Hidetaka;Morikawa, Kaoru;Kanamori, Hitoshi;Matsumoto, Masao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.404-406
    • /
    • 2002
  • We have investigated the contribution of the scattered x rays to the signal imaging in the radiographs acquired with anti-scatter grids of several grid ratios by separating the line spread functions (LSFs) derived from the signal edge image into the primary and the scatter components. By using a 1.0-mm lead plate in the scattering material, the blurred signal edge images were acquired by use of an imaging plate at a tube voltage of 80 kV with the anti-scatter grids of grid ratios for 5:1, 6:1, 8:1, 10:1 and 12:1. The edge profiles of the signal images were scanned and those in relative exposure were differentiated to obtain the LSFs. To investigate the contribution of the scattered x rays to the signal imaging, we proposed a method for separating the LSFs derived from the signal images into the primary and the scatter components, where the scatter component was approximated with exponential function. Our basic approach is to separate the area of the LSFs by ratios of the scattered x-ray exposure to the primary x-ray exposure, which were obtained for the grid ratios by use of a lead disk method. The LSFs and the two components were Fourier transformed to obtain the modulation transfer functions (MTFs) and their two components. As the result, we found that, by using the anti-scatter grids, the scattered x rays were reduced, but the shape of the LSFs of the scatter component hardly changed. The contributions of the scatter component to the MTFs were not negligible (more than 10 %) for spatial frequencies lower than about 1.0 mm$\^$-l/ and that was greater as the grid ratio decreasing. On the other hand, for higher frequencies, the primary component was dominant compared with the scatter component.

  • PDF

전계방사형 주사전자현미경에 의한 연속블록면 이미징 (Serial Block-Face Imaging by Field Emission Scanning Electron Microscopy)

  • 김기우
    • Applied Microscopy
    • /
    • 제41권3호
    • /
    • pp.147-154
    • /
    • 2011
  • 후방산란전자(BSE)는 입사전자빔이 시료와 충돌하면서 발생한다. BSE 이미징은 시료의 화학적 특성을 구분할 수 있는 조성대비를 제공한다. 집속이온빔장치(FIB)는 전계방사형 주사전자현미경(FESEM)과 결합할 수 있으므로 이중빔 체계(FIB-FESEM)가 구현된다. 갈륨(Ga) 이온빔으로 10~100 nm 두께로 시료를 절삭할 수 있으므로 FIB-FESEM은 플라스틱으로 포매된 블록의 면을 z축 고해상도를 유지하며 연속적으로 이미징할 수 있다. BSE이미지의 대비를 반전시키면 투과전자현미경의 이미지와 유사하다. 연속블록면 이미징의 또 다른 방안으로써 특수한 초박절편기가 FESEM 내부에 장착된 것이 $3View^{(R)}$로 상용화되어 있다. 이로써 플라스틱으로 포매된 시료의 내부 구조를 넓은 면적을 연속적으로 이미징 할 수 있으므로 3차원 재구성도 용이하게 된다. 이러한 FESEM에 기반한 두 가지 방식은 복잡한 생물계의 총체적인 이해를 위하여 세포 및 세포 수준 이하의 구조물 간의 공간적 연관성을 규명하는 데 활용될 수 있다.

A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

  • Kajan, Zahra Dalili;Khademi, Jalil;Alizadeh, Ahmad;Hemmaty, Yasamin Babaei;Roushan, Zahra Atrkar
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.159-168
    • /
    • 2015
  • Purpose: This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. Material and Methods: A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo $T_1$-weighted images, fast spin-echo $T_2$-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Results: Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. Conclusion: With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.