• Title/Summary/Keyword: imaging damage

Search Result 284, Processing Time 0.023 seconds

Neuropsychiatric Evaluation of Head-Injured Patients(II) : A Comparative Study of Brain-injured Patients with and without Abnormal Findings in the Structural Brain Imaging - Mainly in Relation to Functional Brain Studies and Psychological Evaluation (두부외상 환자의 신경정신의학적 평가(II) : 뇌의 구조적 영상검사상의 병변 유무에 따른 두부외상 환자군의 비교 - 기능적 및 심리적 검사소견과의 연관성을 중심으로)

  • Cho, Seoung Wook;Chang, Hwan-Il
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.66-74
    • /
    • 1996
  • There has been an increase in head trauma due to rapid industralization and improvement in transportation. This poses difficulties in differentiating between neuropsychiatric disabilities resulting from real organic changes and those arising from compensation issues. It is the purpose of this study to seek out the differences between normal and abnormal finding group in the structural brain imaging studies via the results of the functional brain imaging studies and psychological tests. Out of 132 subjects, 62 comprised normal and 70 the abnormal finding group. EEG and SPECT were chosen for inspection of functional brain imaging. MMPI and K-WAIS were chosen for psychological test. The subjects were further divided into right hemispheric damage, left hemispheric damage, both hemispheric damage, diffuse damage group and negative group in order to find out whether any differences in the psychological lest results could be localized. The results are as follows : 1) The abnormal finding group, the EEG and SPECT were proven to be a good predictor of brain lesion. This implies that even in the functional brain studies, abnormalities are more easily detected if there are visible brain lesions. 2) The FSIQ of the abnormal finding group is lower than that of normal finding group. this difference is mainly due to low V1Q. The left hemispheric damage group lend to shaw low V1Q. This lowered in was the difference between left hemispheric damage group and negative group. Furthermore, there were no group differences in the PIQ. It is concluded that K-WAIS is effective as evaluator of VIQ mainly of those patients with left hemispheric damage and it is ineffective as a evaluator of PIQ. 3) In the MMPI profile, the both groups displayed high neurotic profiles. There was no difference in the psychotic profiles. The scores of the Depression and Hystery were high in abnormal finding group. This can be seen as one of the lypical findings of chronic head trauma patients. 4) The abnormal finding group tend to be diagnosed as organic mental disorder in the psychological tests more frequently.

  • PDF

Analysis of Laser-protection Performance of Asymmetric-phase-mask Wavefront-coding Imaging Systems

  • Yangliang, Li;Qing, Ye;Lei, Wang;Hao, Zhang;Yunlong, Wu;Xian'an, Dou;Xiaoquan, Sun
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Wavefront-coding imaging can achieve high-quality imaging along with a wide range of defocus. In this paper, the anti-laser detection and damage performance of wavefront-coding imaging systems using different asymmetric phase masks are studied, through modeling and simulation. Based on FresnelKirchhoff diffraction theory, the laser-propagation model of the wavefront-coding imaging system is established. The model uses defocus distance rather than wave aberration to characterize the degree of defocus of an imaging system. Then, based on a given defocus range, an optimization method based on Fisher information is used to determine the optimal phase-mask parameters. Finally, the anti-laser detection and damage performance of asymmetric phase masks at different defocus distances and propagation distances are simulated and analyzed. When studying the influence of defocus distance, compared to conventional imaging, the maximum single-pixel receiving power and echo-detection receiving power of asymmetric phase masks are reduced by about one and two orders of magnitude respectively. When exploring the influence of propagation distance, the maximum single-pixel receiving power of asymmetric phase masks decreases by about one order of magnitude and remains stable, and the echodetection receiving power gradually decreases with increasing propagation distance, until it approaches zero.

Imaging Magnetic Flux Leakage based Steel Plate Damage for Steel Structure Diagnosis (강구조물 진단을 위한 누설자속 기반 강판 손상의 이미지화)

  • Kim, Hansun;Kim, Ju-Won;Yu, Byoungjoon;Kim, Wonkyu;Park, Seunghee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.129-136
    • /
    • 2019
  • In this study, the magnetic flux leakage technique was applied to diagnose steel plate damage, imaging technique was applied through those signals. Steel plate specimens with different thicknesses were prepared for the imaging the magnetic flux leakage signal, and 6 different depths of damage were artificially processed at the same locations on each specimen. The sensor head consist hall sensor and magnetization yoke was fabricated to magnetize the steel plate specimen and measure the magnetic flux leakage signal. In order to remove the noise and increase the resolution of the image in the signal collected from the hall sensor, various of signal processing was performed. P-P value was analyzed for each channel to analyze the magnetic flux leakage signals measured from each damaged part. Based on the above processed signals and analysis, it was converted into heatmap image. Through this, it was possible to identify the damage on the steel plate at glance by imaging magnetic flux leakage signal.

Performance Analysis of Spiral Axicon Wavefront Coding Imaging System for Laser Protection

  • Haoqi Luo;Yangliang Li;Junyu Zhang;Hao Zhang;Yunlong Wu;Qing Ye
    • Current Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.355-365
    • /
    • 2024
  • Wavefront coding (WFC) imaging systems can redistribute the energy of an interference laser spot on an image plane sensor by wavefront phase modulation and reduce the peak intensity, realizing laser protection while maintaining imaging functionality by leveraging algorithmic post-processing. In this paper, a spiral axicon WFC imaging system is proposed, and the performance for laser protection is investigated by constructing a laser transmission model. An Airy disk on an image plane sensor is refactored into a symmetrical hollow ring by a spiral axicon phase mask, and the maximum intensity can be reduced to lower than 1% and single-pixel power to 1.2%. The spiral axicon phase mask exhibits strong robustness to the position of the interference laser source and can effectively reduce the risk of sensor damage for an almost arbitrary lase propagation distance. Moreover, we revealed that there is a sensor hazard distance for both conventional and WFC imaging systems where the maximum single-pixel power reaches a peak value under irradiation of a power-fixed laser source. Our findings can offer guidance for the anti-laser reinforcement design of photoelectric imaging systems, thereby enhancing the adaptability of imaging systems in a complex laser environment. The laser blinding-resistant imaging system has potential applications in security monitoring, autonomous driving, and intense-laser-pulse experiments.

ASSESSMENT OF INFERIOR ALVEOLAR NERVE DAMAGE USING DIGITAL INFRARED THERMOGRAPHIC IMAGING (디지털 적외선 체열 검사를 사용한 하치조 신경 손상의 평가)

  • Lee, Ji-Yeon;Lee, Jae-Hoon;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.6
    • /
    • pp.488-496
    • /
    • 2004
  • Oral & Maxillofacial surgery can lead to complications that result in abnormal sensation or movement. Inferior alveolar nerve(IAN) injury can result in dysesthesia, paresthsia of the lower lip and chin, so patients presenting with IAN damage suffer from sensory loss. But diagnosis of the nerve injury is largely limited to the subjective statements made by the patient. Distribution of sympathetic nerves parallels the distribution of the somatosensory nerves. Loss of sensory tone causes a concomitant loss of sympathetic activity, resulting in vasodilation of the cutaneous blood vessels that demonstrates greater heat loss. Digital infrared thermographic imaging(DITI) detects infra-red radiation given off by body. DITI can detect minute difference in temperature from different parts of the body and translates the amount of heat into quantitative data. The area of different temperature correlated with pain or disease can be visualized by corresponding color. The objective of this study was to determine the efficacy of DITI in objectively assessing IAN injury. The 19 normal subjects and the 14 patients underwent DITI scan. The normal subjects received unilateral IAN block anesthesia with 2 ml of 2% lidocaine (IAN bolck group) to evaluate temporary alteration in nerve function. Patient group were patients with unilateral IAN damage (dysesthesia or paresthesia) after surgical treatment(Mn. 3rd molar Extraction, etc.). The surgical procedure performed within 6 months of test. The results were as follows. 1. No significant differences in temperature were found between left and right sides of the lower lip and chin in the control group. 2. Significant temperature differences were found between the anesthetized and non-anesthetized sides of the lower lip and chin in the IAN block group. 3. Significant temperature differences were found between the involved and uninvolved sides of the lower lip and chin areas of the experimental group. The results of the study show that DITI can be an useful and effective means of objectively assessing and visualizing IAN damage.

Multiparametric Functional Magnetic Resonance Imaging for Evaluating Renal Allograft Injury

  • Yuan Meng Yu;Qian Qian Ni;Zhen Jane Wang;Meng Lin Chen;Long Jiang Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.894-908
    • /
    • 2019
  • Kidney transplantation is the treatment of choice for patients with end-stage renal disease, as it extends survival and increases quality of life in these patients. However, chronic allograft injury continues to be a major problem, and leads to eventual graft loss. Early detection of allograft injury is essential for guiding appropriate intervention to delay or prevent irreversible damage. Several advanced MRI techniques can offer some important information regarding functional changes such as perfusion, diffusion, structural complexity, as well as oxygenation and fibrosis. This review highlights the potential of multiparametric MRI for noninvasive and comprehensive assessment of renal allograft injury.

Magnetic Resonance Imaging as a Biomarker for Duchenne Muscular Dystrophy

  • Lim, Woo-taek
    • Physical Therapy Korea
    • /
    • v.22 no.3
    • /
    • pp.98-105
    • /
    • 2015
  • Muscular dystrophy is a hereditary musculoskeletal disorder caused by a mutation in the dystrophin gene. Duchenne muscular dystrophy (DMD) is one of the most common, and progresses relatively faster than other muscular dystrophies. It is characterized by progressive myofiber degeneration, muscle weakness and ultimately ambulatory loss. Since it is an X-linked recessive inheritance, DMD is mostly expressed in males and rarely expressed or less severe in females. The most effective measurement tool for DMD is magnetic resonance imaging (MRI), which allows non-invasive examination of longitudinal measurement. It can detect progressive decline of skeletal muscle size by measuring a maximal cross-sectional area of skeletal muscle. Additionally, other techniques in MRI, like $T_2$-weighted imaging, assess muscle damage, including inflammation, by detecting changes in $T_2$ relaxation time. Current MRI techniques even allow quantification of metabolic differences between affected and non-affected muscles in DMD. There is no current cure, but physical therapist can improve their quality of life by maintaining muscle strength and function, especially if treatment (and other forms of medical intervention) begins in the early stages of the disease.

A Diagnostic Ultrasound Imaging System (초음파 영상진단장치)

  • Lee, Seong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.217-232
    • /
    • 1999
  • The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result. their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result. the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described.

  • PDF

A Guided Wave-Based Structural Damage Detection Method for Structural Health Monitoring (구조물의 건전성 모니터링을 위한 유도초음파 응용 구조손상 탐지기법)

  • Go, Han-Suk;Lee, U-Sik
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.3
    • /
    • pp.412-419
    • /
    • 2009
  • How to efficiently and accurately detect the damages generated in a structure has become an important issue for structural health monitoring (SHM). Most existing SHM techniques require the baseline data which should be measured before a structure get damaged. Thus, this paper presents a new pitch-catch method-based SHM technique which will not require the baseline data any more. In the proposed SHM technique, the imaging method is also utilized to visualize damage locations. The proposed SHM technique is then validated through the damage detection texts for damaged aluminum plates.

Variations of imaging depth and chloroplast emission spectrum of Arabidopsis thaliana with excitation wavelength in two-photon microscopy (이광자현미경 여기 광 파장에 따른 Arabidopsis thaliana 촬영 깊이 및 엽록체 형광 스펙트럼의 변화)

  • Joo, Yongjoon;Son, Si Hyung;Kim, Ki Hean
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.3
    • /
    • pp.9-14
    • /
    • 2014
  • Two-photon microscopy (TPM) has been used in plant research as a high-resolution high-depth 3D imaging modality. However, TPM is known to induce photo-damage to the plant in case of long time exposure, and optimal excitation wavelength for plant imaging has not been investigated. Longer excitation wavelength may be appropriate for in vivo two-photon imaging of Arabidopsis thaliana leaves, and effects of longer excitation wavelength were investigated in terms of imaging depth, emission spectrum. Changes of emission spectrum as a function of exposure time at longer excitation wavelength were measured for in vivo longitudinal imaging. Imaging depth was not changed much probably because photon scattering at the cell wall was a limiting factor. Chloroplast emission spectrum showed its intensity peak shift by 20 nm with transition of excitation wavelength from 849 nm or below to 850 nm or higher. Emission spectrum showed different change patterns with excitation wavelengths in longitudinal imaging. Longer excitation wavelengths appeared to interact with chloroplasts differently in comparison with 780 nm excitation wavelength, and may be good for in vivo imaging.