• 제목/요약/키워드: imaging damage

검색결과 284건 처리시간 0.03초

Cryptogenic Temporal Hollowing

  • Park, Ie Hyon;Kwon, Heeyeon;Kim, Sang Wha
    • 대한두개안면성형외과학회지
    • /
    • 제17권4호
    • /
    • pp.218-221
    • /
    • 2016
  • Temporal hollowing is a common complication that occurs after coronal approach surgeries. However, temporal hollowing without previous nerve damage or trauma history is rare. Herein, we present a patient with cryptogenic temporal hollowing. A 22-year-old man without any history of craniofacial interventions or trauma presented with temporal hallowing. Magnetic resonance imaging revealed fatty degeneration of the left temporalis muscle. Electromyography and nerve conduction study showed no signs of neurologic abnormalities. The patient received autologous fat injection of 30 mL harvested from the left thigh using the modified Coleman technique. Temporal hollowing is commonly caused by atrophy of the superficial temporal fat pad. Its incidence is reported to be as high as 6% after coronal approach operation. Augmentation using porous hydroxyapatite or titanium mesh is a treatment option. Autologous fat graft can also be an option for mild to moderate temporal hollowing. In this case, a patient with no history of trauma, surgery, or myogenic disease developed temporal hollowing. Further study of the little-known cryptogenic form of temporal hollowing is warranted.

레이저 초음파 기반 반사식 회전 검사 기법을 이용한 오토클레이브 가공 L 형 복합재 구조물의 모서리 검사 (Corner Inspection of Autoclave-cured L-shaped Composite Structure using Pulse-echo Rotation Scanning Scheme based on Laser Ultrasonic)

  • 이영준;이정률;홍성진
    • Composites Research
    • /
    • 제31권5호
    • /
    • pp.246-250
    • /
    • 2018
  • 본 연구에서는 곡면 복합재 구조물의 모서리에 위치한 결함을 검사하고 가시화하기 위해 제안된 레이저 초음파 기반 회전식 검사 기법을 소개한다. 모서리 부위에 결함이 위치한 L 형 복합재 구조물을 레이저 초음파 기반 회전식 검사 기법을 이용하여 검사하였다. L 형 시편은 층간분리 손상을 모사하기 위해 각기 다른 세 가지 깊이에 위치한 인공 결함을 포함하고 있다. 모든 인공 결함이 각각의 위치한 깊이에 따라 다른 시간대에 선명하게 탐지되었다. 검사결과는 제안된 방법이 어떠한 특별한 도구 없이도 곡면 복합재 구조물의 모서리 부위의 검사에 적합하다는 것을 보여준다.

Predictive Markers for Screening Renal Damage in Children with Urinary Tract infections and Vesicoureteral Reflux

  • Lee, Hyeonju;Choi, Jae Hong;Kang, Dong-Hyeok;Kim, Seunghyo;Kang, Ki-Soo;Han, Kyoung Hee
    • Childhood Kidney Diseases
    • /
    • 제24권1호
    • /
    • pp.27-35
    • /
    • 2020
  • Purpose: Urinary tract infections (UTIs) are the most common and serious bacterial infections in children. Therefore, early diagnosis of vesicoureteral reflux (VUR) for treatment planning and the identification of noninvasive markers that can predict renal injury are important in patients with UTIs. We analyzed the clinical features of pediatric UTIs commonly encountered by general practitioners and reinterpreted the blood tests and imaging findings to identify the important clinical predictive markers of VUR in order to selectively perform VCUG. Methods: This retrospective study was performed among 183 children diagnosed with a UTI or acute pyelonephritis. Results: The most significant predictor of high grade and bilateral VUR identified using area under the curve analyses was hydronephrosis on kidney ultrasound images with renal cortical defects on dimercaptosuccinic acid (DMSA) kidney scan simultaneously, followed by hydronephrosis only on kidney ultrasound. Conclusion: The presence of hydronephrosis on kidney ultrasound images or cortical defects or asymmetric kidneys on the DMSA kidney scans can be predictive markers of VUR, reducing the need for VCUG. Our study can thus help minimize the exposure to radiation among patients through selective VCUG.

High-speed angular-scan pulse-echo ultrasonic propagation imager for in situ non-destructive evaluation

  • Abbas, Syed H.;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.223-230
    • /
    • 2018
  • This study examines a non-contact laser scanning-based ultrasound system, called an angular scan pulse-echo ultrasonic propagation imager (A-PE-UPI), that uses coincided laser beams for ultrasonic sensing and generation. A laser Doppler vibrometer is used for sensing, while a diode pumped solid state (DPSS) Q-switched laser is used for generation of thermoelastic waves. A high-speed raster scanning of up to 10-kHz is achieved using a galvano-motorized mirror scanner that allows for coincided sensing and for the generation beam to perform two-dimensional scanning without causing any harm to the surface under inspection. This process allows for the visualization of longitudinal wave propagation through-the-thickness. A pulse-echo ultrasonic wave propagation imaging algorithm (PE-UWPI) is used for on-the-fly damage visualization of the structure. The presented system is very effective for high-speed, localized, non-contact, and non-destructive inspection of aerospace structures. The system is tested on an aluminum honeycomb sandwich with disbonds and a carbon fiber-reinforced plastic (CFRP) honeycomb sandwich with a layer overlap. Inspection is performed at a 10-kHz scanning speed that takes 16 seconds to scan a $100{\times}100mm^2$ area with a scan interval of 0.25 mm. Finally, a comparison is presented between angular-scanning and a linear-scanning-based pulse-echo UPI system. The results show that the proposed system can successfully visualize defects in the inspected specimens.

소형 변압기 안전성 실태 분석 및 고찰 (The Safety Survey Analysis and Consideration of Small Transformer)

  • 김성삼
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.

Simultaneous Detection of Biomolecular Interactions and Surface Topography Using Photonic Force Microscopy

  • 허승진;김기범;조용훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.402.1-402.1
    • /
    • 2014
  • Photonic force microscopy (PFM) is an optical tweezers-based scanning probe microscopy, which measures the forces in the range of fN to pN. The low stiffness leads proper to measure single molecular interaction. We introduce a novel photonic force microscopy to stably map various chemical properties as well as topographic information, utilizing weak molecular bond between probe and object's surface. First, we installed stable optical tweezers instrument, where an IR laser with 1064 nm wavelength was used as trapping source to reduce damage to biological sample. To manipulate trapped material, electric driven two-axis mirrors were used for x, y directional probe scanning and a piezo stage for z directional probe scanning. For resolution test, probe scans with vertical direction repeatedly at the same lateral position, where the vertical resolution is ~25 nm. To obtain the topography of surface which is etched glass, trapped bead scans 3-dimensionally and measures the contact position in each cycle. To acquire the chemical mapping, we design the DNA oligonucleotide pairs combining as a zipping structure, where one is attached at the surface of bead and other is arranged on surface. We measured the rupture force of molecular bonding to investigate chemical properties on the surface with various loading rate. We expect this system can realize a high-resolution multi-functional imaging technique able to acquire topographic map of objects and to distinguish difference of chemical properties between these objects simultaneously.

  • PDF

척수공동증 의증으로 인한 감각장애 환자 치험 1례 (Case Report of Sensory Disturbance with Suspicious Syringomyelia)

  • 강백규;한덕진;이정욱;김회영;이인;김강산;박상무
    • 동의생리병리학회지
    • /
    • 제22권1호
    • /
    • pp.246-251
    • /
    • 2008
  • Syringomyelia is a rare disorder that causes a cyst to form in spinal cord. This cyst, called a syrinx, can damage to the spinal cord and cause symptoms such as motor weakness, pain, sensory disturbance, etc. We experienced a case of tactile hypesthesia suspecting syringomyelia in 16 year old male patient. Syringomyelia in T2/3 level was diagnosed by magnetic resonance imaging. Hypesthesia was similar to mamokbulin in oriental medicine. And we assumed these symptoms induced by conditions called kiheo in analyzing patient's symptoms and signs. We treated the patient by acupuncture, herbal medicine improving kiheo, and other methods. In the result, the symptoms had withdrawn. This case suggested possibility to treat syringomyelia in oriental medicine, but single case is insufficient for evidence.

일시적으로 증가하는 간기능지표에 대한 연구 (A Temporary Increase of Liver Function Indicators, AST, ALT)

  • 김숙자;전영미;송웅주
    • 대한유전성대사질환학회지
    • /
    • 제13권1호
    • /
    • pp.43-47
    • /
    • 2013
  • Introduction: ALT/AST enzymes are present inside the cells. AST is found in cardiac and skeletal muscle and red blood cells but the ALT is checked mainly in the liver. In general, the rise of these two indicators shows liver damage. The usual measurements of these enzymes are used in liver function tests, but the levels of AST and ALT do not always reflect liver function. Method and Cases: 17 cases of liver dysfunction transiently were evaluated clinically, biochemically, and imaging study of sonogram in pediatric in-patients for 3 years. Result: Most common causes of transient liver dysfunction were infection, especially viral gastroenteritis, and bacterial infection interfering oral food intake. More often occurred in the children who have infant hyperbilirubinemia, positive history of mitochondrial dysfunction or hypoglycemia. Fasting study in one case of hypoglycemia patient showed reversible liver dysfunction during fasting over 20 hours fasting. Discussion: A significant increase in AST and ALT with normal bilirubin can be observed in clinically healthy people during blunt trauma, viral infection, severe pain, metabolic syndrome, fasting or accidental health screening.

  • PDF

자동화 손상 검색을 위한 비접촉식 레이저 초음파 영상화 (Noncontact Laser Ultrasonic Imaging for Automated Damage Detection)

  • 박병진;안윤규;손훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.40-43
    • /
    • 2011
  • 최근, 레이저 초음파 영상화 기법은 구조물의 비접촉식 손상 진단을 위해 널리 연구되고 있다. 초음파 영상화 기법의 가장 큰 장점은 비접촉식으로 구조물의 손상을 진단할 수 있고, 가진 및 측정 지점을 자유로이 이동할 수 있다는 점이다. 따라서 이는 고온이나 동적상태의 구조물에 적용이 가능하며, 시간과 공간상의 충분한 데이터를 획득할 수 있으므로 역문제 (Inverse problem)를 해결할 필요 없이 완전한 초음파의 전파 형상을 얻을 수 있다. 지난 연구들에서는 충분한 가진력 혹은 측정 민감도를 확보하기 위해 가진 레이저와 부착형 센서의 조합이나 부착형 가진 트렌스듀서와 센싱 레이저의 조합으로 초음파 영상을 획득하고자 하였다. 하지만 이들 조합은 가진 혹은 측정 지점이 구조물에 부착되어 있어 완전한 비접촉식 기법을 구현하지 못하였다. 이를 극복하고자 레이저와 EMAT 센서 등의 조합이 시도되어 왔으나, 이 또한 EMAT 센서의 적용 거리에 따른 한계점을 지니고 있다. 본 연구에서는 가진 레이저 (Nd:Yag)의 스캐닝을 통해 다양한 가진 점에서 발생된 초음파가 탄성체 구조물을 통해 전파되고, 이를 센싱 레이저 (Laser Doppler Vibrometer)를 이용하여 측정함으로써 비접촉식 초음파 영상화를 구현하였다. 나아가, 정상파 필터(Standing-wave filter)를 이용하여 구현된 초음파 영상으로부터 손상 영향만 검출해 내는 기법을 개발했다. 개발된 기법은 복합재 시편의 층간박리 (Delamination) 진단을 통해 검증하였다.

  • PDF

Visualization of Crust in Metallic Piping Through Real-Time Neutron Radiography Obtained with Low Intensity Thermal Neutron Flux

  • Luiz, Leandro C.;Ferreira, Francisco J.O.;Crispim, Verginia R.
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.781-786
    • /
    • 2017
  • The presence of crust on the inner walls of metallic ducts impairs transportation because crust completely or partially hinders the passage of fluid to the processing unit and causes damage to equipment connected to the production line. Its localization is crucial. With the development of the electronic imaging system installed at the Argonauta/Nuclear Engineering Institute (IEN)/National Nuclear Energy Commission (CNEN) reactor, it became possible to visualize crust in the interior of metallic piping of small diameter using real-time neutron radiography images obtained with a low neutron flux. The obtained images showed the resistance offered by crust on the passage of water inside the pipe. No discrepancy of the flow profile at the bottom of the pipe, before the crust region, was registered. However, after the passage of liquid through the pipe, images of the disturbances of the flow were clear and discrepancies in the flow profile were steep. This shows that this technique added the assembled apparatus was efficient for the visualization of the crust and of the two-phase flows.