• 제목/요약/키워드: image verification device

검색결과 45건 처리시간 0.022초

증기발생기 유로홈막힘 사진판독 알고리즘 개발 (Development of the S/G TSP Clogging Image Analysis Algorithm)

  • 조남철;김왕배;문찬국
    • 한국압력기기공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.8-14
    • /
    • 2011
  • The clogging of the flow area at the tube support plates(TSPs), especially at the upper TSPs results in the water level oscillation of a steam generator during normal operation. A reduction of the TSP flow area causes to increase in pressure drop within the two-phase flow zone, which destabilizes the boiling flow through the tube bundle. This phenomenon was occasionally observed at a few domestic and foreign nuclear power plants. One of the methods for defining the flow area clogging is visual inspection, which is the most effective inspection method. The results of the visual inspection for TSPs' flow area are clogging images on TSPs' quartrefoil lobes. These images are complexly distorted due to lens aberration and external factors like the distance to a subject and angle etc. In this work, we developed the analysis algorithm for clogging image of the TSP flow area of steam generators. For this purpose, we designed an image verification device applicable to the camera employed in the field for visual inspection and then, we demonstrated the validity of image analysis algorithm by using this device and commercial autoCAD program.

Development of Electronic Portal Imaging Device and Treatment Position Verification for Fractionated Stereotatic Radiotherapy

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Chilgoo Byun;Hong, Seung-Hong;Rhee, Soo-Yong
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.446-449
    • /
    • 2002
  • The video based electronic portal imaging device (EPID), which could display the portal image in near real time, was implemented to verify treatment position error in FSRT(Fractionated Stereotatic Radiation Therapy) instead of a portal film. Also, Developed FSRT system was composed of the stereotactic frame, frame mounting system and collimator cones. The verification of treatment position is very crucial in special therapies like FSRT. In general, the FSRT uses high dpse rate at small field size for treating small intracranial lesions. To evaluate quantitative positioning errors in FSRT, we used the first FSRT image as reference image and obtained the second FSRT image that was moved 2mm intentionally and detected intracranial contours after image processing. The generated 2mm error could be verified by overlapping only contours of two images. Through this study, the radiation treatment efficiency could be improved by performing precise radiation therapy with a developed video based EPID and FSRT.

  • PDF

850 nm 파장대 근적외선과 갈바닉 전류기반의 눈가 주름 치료기 개발 및 영상 분석을 통한 치료성능 검증 (Design of 850 nm Near Infrared and Galvanic Current Based Eyeglass-Type Device for Periorbital Wrinkle Treatment and Verification of Treatment Performance through Image Analysis)

  • 안성수;권기진
    • 한국멀티미디어학회논문지
    • /
    • 제21권12호
    • /
    • pp.1379-1386
    • /
    • 2018
  • In this paper, we proposed eyeglass type periorbital wrinkle treatment device for reducing and improving periorbital wrinkles using near infrared LED of 850nm wavelength and galvanic current. The proposed periorbital wrinkle treatment device is equipped with a control system based on F-PCB. It consists of eight near-infrared LEDs and four indicator LEDs for treatment of right and left periorbital wrinkles. The eyeglass frame is coated with conductive material, so galvanic current can flow to the skin of periorbital wrinkle contacted to it. One male adult in the mid-40s was allowed to use the device for 10 minutes every day for 4 weeks. After 4 weeks, image analysis using optical equipment for measuring wrinkles indicated that wrinkle indexes were reduced.

CMOS 카메라 이미지 센서용 ISP 구현 (An Implementation of ISP for CMOS Image Sensor)

  • 손승일;이동훈
    • 한국정보통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.555-562
    • /
    • 2007
  • CMOS 이미지 센서로부터 수신한 베이어 입력 스트림을 디스플레이 장치로 보기위해서는 영상 신호처리를 수행해야 한다. 즉, 이러한 영상 신호처리를 수행한 부분을 ISP(Image Signal Processor)라 한다. ISP 처리를 통해서 실제 원본 이미지를 볼 수 있다. ISP는 감마교정, 인터폴레이션, 공간적 변환, 이미지 효과, 이미지 스케일, AWB, AE, AF 등과 같은 기능을 수행한다. 본 논문에서는 CMOS 카메라 이미지 센서용 ISP를 모델링하여 최적화 알고리즘을 소프트웨어 검증을 통해 도출하였으며, VHDL 언어를 이용하여 설계하고 ModelSim6.0a 시뮬레이터를 이용하여 검증하였다. 또한 보드 레벨의 검증을 위해 PCI 인터페이스를 이용하여 설계한 ISP 모듈을 자일링스 XCV-1000e에 다운로드하여 결과를 확인하였다.

Strategies to improve the range verification of stochastic origin ensembles for low-count prompt gamma imaging

  • Hsuan-Ming Huang
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3700-3708
    • /
    • 2023
  • The stochastic origin ensembles method with resolution recovery (SOE-RR) has been proposed to reconstruct proton-induced prompt gammas (PGs), and the reconstructed PG image was used for range verification. However, due to low detection efficiency, the number of valid events is low. Such a low-count condition can degrade the accuracy of the SOE-RR method for proton range verification. In this study, we proposed two strategies to improve the reconstruction of the SOE-RR algorithm for low-count PG imaging. We also studied the number of iterations and repetitions required to achieve reliable range verification. We simulated a proton beam (108 protons) irradiated on a water phantom and used a two-layer Compton camera to detect 4.44-MeV PGs. Our simulated results show that combining the SOE-RR algorithm with restricted volume (SOE-RR-RV) can reduce the error of the estimation of the Bragg peak position from 5.0 mm to 2.5 mm. We also found that the SOE-RR-RV algorithm initialized using a back-projection image could improve the convergence rate while maintaining accurate range verification. Finally, we observed that the improved SOE-RR algorithm set for 60,000 iterations and 25 repetitions could provide reliable PG images. Based on the proposed reconstruction strategies, the SOE-RR algorithm has the potential to achieve a positioning error of 2.5 mm for low-count PG imaging.

영상증배관을 이용한 실시간 영상획득시스템과 위치오차검증 (Real Time Image Acquisition System using a Image Intensifier and Position Error Verification)

  • 이동훈;김남훈;정종범
    • 재활복지공학회논문지
    • /
    • 제11권4호
    • /
    • pp.331-338
    • /
    • 2017
  • 본 연구에서는 포터블 형 X-ray 발생장치를 제작하였고, 제작된 발생장치로부터 영상증배관을 이용하여 실시간 영상획득시스템 구축하였다. 획득된 영상으로부터 인공관절 위치가 초기 영상과 차이가 있는지를 검증할 수 있는 실시간 위치오차검증 시스템을 개발하였다. 패턴 매칭 기법을 이용하여 간단히 기준영상에서 관심영역 부위의 템플릿영상을 추출하여 비교하고 싶은 비교영상과 비교하여 본 결과 500-1000점 사이의 유사도를 수치로 표시하여 유사정도를 알 수 있었고, x, y 위치와 차이가 나는 각도를 표시해 줌으로써 실시간 위치오차검증이 가능함을 알 수 있었다. 본 시스템은 포터블형이며, 자체 차폐시설을 갖추고 있다. 조사장치의 출력도 1kw의 소형으로 제작되어 이동형으로 사용할 수 있으며, 산업용의 비파괴분야 및 의료기관이 없는 외진 곳에서 발생된 응급환자의 경우 손, 발과 같은 작은 부위의 진단용 분야 등에 활용할 수 있는 유효성을 보여주었다.

배터리 교체형 전기자동차의 배터리 위치좌표 획득을 위한 영상처리기술 검증 (Replaceable battery electric car's battery location coordinates image processing techniques for obtaining verification)

  • 김응필;정원재;김정윤;박준석;김태희
    • 정보통신설비학회논문지
    • /
    • 제11권2호
    • /
    • pp.52-57
    • /
    • 2012
  • In this paper describe configuration about QCM system for image processing device. It presents that QCM's image processing board video from the camera recognized by the PLC's battery removable exact location coordinates to the robot image processing technology to deliver. In addition, QCM video image processing technology for improved data reliability is described. In this paper define the landmarks of battery for obtaining the location coordinates and verify battery the location coordinates acquisition process from field tests of the QCM/QTPE-BUS Battery Exchange System.

  • PDF

정위적 방사선 수술시 치료위치에서의 정위적 표적점 확인을 통한 자기공명영상 획득의 정확도 연구 (Verification of Stereotactic Target Point Achieved by Acquisition of MR Image in Actual Treatment Position of Radiosurgery)

  • 윤형근;신교철;김영식
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.89-94
    • /
    • 1998
  • 자기공명영상을 정위적 방사선 수술에 이용하기 위한 우선 과제로 비교적 균일한 phantom에서 자기공명영상으로 구한 정위적 표적점이 실제 방사선수술시의 방사선 빔의 isocenter와 일치하는지 확인하고자 하였다. 무 속에 임의의 표적점이 표시된 선량측정용 필름을 끼우고 head ring 을 고정시킨 다음 자기공명영상올 얻어 방사선 수술용 planning computer 로 표적점의 정위적 좌표를 구한 다음 실제 치료와 같이 무 phantom 을 테이블에 고정한 후 구해진 표적점의 좌표를 isocenter로 하여 방사선을 조사하고 필름을 현상하여 필름에 표시한 표적점과 실제 방사선이 조사된 부위의 선량분포의 중심을 비교하였는데 오차가 0.5 mm 이내였다. 따라서 무와 같은 비교적 균일한 phantom 에서는 표적점과 실제 방사선이 조사된 부위의 선량분포의 중심이 잘 일치함을 알 수 있었다. 또 다른 방법으로 자기공명영상의 왜곡의 정도를 직접 확인하기 위해서 아크릴에 1 cm 간격으로 구멍을 뚫고 오일방울을 넣어준 후 아크릴 phantom을 무 속에 수평과 수직방향으로 삽입한 뒤 자기공명영상을 얻은 후 각각의 좌표를 구하여 자기공명영상의 수평과 수직방향에서 왜곡의 정도를 측정하였다. 결과는 균일한 물질 내에서는 7 cm 거리에서 0.4 mm 이내의 오차를 보여서 비교적 잘 일치하였다. 그런데 이 측정과정에서 device 자체와 digitizing 과정의 오차가 있는 것으로 판단되므로 더 정교한 device 의 제작이 필요한 것으로 생각된다.

  • PDF

전자포탈영상 (EPI)을 이용한 의료용 선형가속기의 성능평가에 관한 연구 (A study of Quality evaluation for medical linear accelerator using Electronic Portal Imaging)

  • 윤성익;권수일;추성실
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.105-113
    • /
    • 1998
  • 고에너지 광자선을 발생시키는 의료용선형가속기의 선질은 경우에 따라 변이를 가져오게 된다. 이러한 변이를 정확하게 판정하여 줄 수 있는 방사선측정법의 활용은 매우 중요하다. 보편적으로 광자선의 측정에 있어서 전리함의 사용이 아주 빈번하였으나 전자포탈영상장치(EPID)의 등장은 새로운 방사선측정법에 대한 가능성의 시작을 예견해준다. 실험은 6MV 광자선의 대칭성, Light/Radiation congruence, 그리고 Wedge filter를 통한 간편한 에너지의 변화에측과 위치의 정확도에 대하여 측정을 시행하였다. 사실 방사선측정의 대표적인 방법은 물팬톰-전리함응 이용한 모델인데 본 실험에서는 영상의 화소가 지니는 디지탈 값을 적절한 소프트웨어로 읽어내어서 데이터를 환산하여 결과를 얻었다. 선행실험에서 얻은 상대선량률을 적용하여 대칭성에서는 조사야영역이 l0$\times$10$cm^2$ 일 때 횡축과 종축에서 1.2%, 1.2%로 비교적 오차가 적었다. 그리고 Light/Radiation field congruence 여부는 횡축이 0.3%, 그리고 종축이 0.2%로서 예상한 기대값에 접근하였다. 다음으로 wedge filter를 활용한 에너지의 변이와 위치의 정확도에 대한 움직임을 알 수 있었다.

  • PDF

전자포탈영상장치의 제작과 방사선치료장치의 QA 적용에 관한 연구 (A Study on QA for Radiation Therapy Machine by Using Implemented Electronic Portal Imaging Device)

  • 이동훈
    • 전자공학회논문지SC
    • /
    • 제43권6호
    • /
    • pp.68-75
    • /
    • 2006
  • 고 에너지 방사선을 이용하여 종양을 치료하는 과정 중 발생되는 오차를 확인하여 보다 정교한 치료를 수행함으로써 방사선치료 효율을 향상시킬 수 있다. 본 논문에서는 지금까지 주로 사용되어진 필름을 이용한 아날로그 방식대신 실 시간적으로 영상을 얻을 수 있는 디지털 방식의 비디오 기반 전자 포탈 영상 장치를 개발하였다. 시스템은 $Gd_2O_2S$ 인광판, $45^{\circ}$반사경 및 후레임 그래버를 이용 비디오 기반 전자 포탈 영상 장치를 제작하였으며 이를 방사선치료기의 QA장치로 활용하고자 하였다. 이 장치를 이용 치료기 자체의 정확도를 검증하기 위해 방사선 조사면 검증을 수행하였다. 방사선 조사면이 콜리메이터 회전오차에 의해 약 $0.6^{\circ}$틀어짐을 전자 포탈 영상 장치를 통해 획득된 영상의 윤곽선을 검출한 후 알 수 있어서 치료 위치 설정 중 발생할 수 있는 오차 확인을 위한 방사선 치료장치의 Q.A도구로 사용할 수 있었다.