• Title/Summary/Keyword: illumination environment

Search Result 449, Processing Time 0.028 seconds

A Comparison of Legibility Based on Illumination Intensity and Contrast Ratio in Displays (디스플레이에서 조도와 대비비에 따른 가독성 비교 연구)

  • Hong, Ji-Young;Min, Jang-Geun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.4
    • /
    • pp.71-76
    • /
    • 2017
  • Visual perception is part of a field of study that examines the analysis and recognition of objects. There have been numerous studies on this topic, including research on the physiological and cognitive aspects of the visual system. Visual perception theory was established through such research efforts and the potential for its application in each field is being investigated. Mobile displays are a representative example of media in the new age. Therefore, this study is based on the understanding that research on visual perception must stress the importance of useful visual cognition. This study used displays to conduct legibility tests based on illumination intensity and contrast ratio. Two conditions relevant to legibility were tested 1) illumination intensity environment and 2) two luminance conditions proposed as measures to improve readability in existing mobile displays. The results of this study were analysed to determine the degree of legibility based on illumination intensity and contrast ratio, and measures for improving legibility were proposed.

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

The Actual State of Indoor Environment in Solitary Elderly Houses at Rural District during Winter (농촌지역 독거노인주택의 겨울철 실내환경 실태)

  • Choi, Yoon-Jung;Kim, Yun-Hee;Kim, Lan-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.1-9
    • /
    • 2010
  • The purposes of this study were to determine the actual state of indoor environments of solitary elderly houses in the rural district during winter and to analyze the relationship between the influencing factors and indoor physical elements. Field surveys consisted of measurements of physical elements, observations of living factors, and resident's responses in interviews. Field surveys were carried out in 4 houses from $28^{th}$ of February to $2^{nd}$ of March 2008. The elements measured were air temperature, relative humidity, floor temperature, seating-place temperature, CO2 concentration, CO concentration, and illumination. The results showed that the average indoor temperature for houses was $13.5{\sim}22.5^{\circ}C$, relative humidity was 30.6~55.4%, floor temperature was $13.9{\sim}24.0^{\circ}C$, temperature when seated was $27.6{\sim}51.1^{\circ}C$, $CO_2$ concentration was 1434.6~3305.5 ppm, CO concentration was 2.8~8.4 ppm, and illumination was 31.0~96.7 lux. The residents' clothing values were 1.10~1.78 clo. The environment was evaluated as being in an unsuitable state, and it was revealed that the main reason was the lack of heating and ventilation.

The Actual State of Indoor Environment in Solitary Elderly Houses at Rural District during Winter (농촌지역 독거노인주택의 겨울철 실내환경 실태)

  • Choi, Yoon-Jung;Kim, Yun-Hee;Kim, Lan-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.452-457
    • /
    • 2008
  • The purposes of this study were to determine the actual state of indoor environment and to analyze the relationship between the living factors and indoor physical elements in solitary elderly houses at rural district during winter. The field surveys were consisted of measurements of physical elements, observations of living factors, and interviews of resident's responses. The field surveys were fulfilled in 4 houses from February to March 2008. Measuring elements were air temperature, relative humidity, floor temperature, seated place temperature, $CO_2$, CO, and illumination. The results showed that the average of indoor temperature for houses was $13.5{\sim}22.5^{\circ}C$, relative humidity was $30.6{\sim}55.4%$, floor temperature was $13.9{\sim}24.0^{\circ}C$, seated place temperature was $27.6{\sim}51.1^{\circ}C$, $CO_2$ was $1434.6{\sim}3305.5ppm$, CO was $2.8{\sim}8.4ppm$, illumination was $31.0{\sim}96.7lux$. The residents' clothing values were $1.10{\sim}1.78clo$. Most of the residents' subjective responses were in discord with the physical elements. It was evaluated to be uncomfortable state, and the main reason was revealed lack of heating and ventilation.

  • PDF

A comparative study on the light environment of the classroom classified by floor , time (강의실 빛 환경의 층별 , 시간대별 비교연구)

  • 곽경숙
    • Journal of the Korean housing association
    • /
    • v.4 no.2
    • /
    • pp.1-9
    • /
    • 1993
  • This study is a basic research to analyze and estimate the light environment of the classroom by serial correlation of time. Its purpose lies in the comparison by time period in order In select floor for laboratory and to calculate the uniformity factor. The proving ground is T building in W university, Which is five floor of central hall type. The subject of investigating is eight classrooms, four rooms in South and North, from the second floor that is net influenced by the shelter. The results that compared and estimated them in the illumination of daylight, Uniformity factor, Daylight factor, are as follows1. The illumination of classroom in South and North is over 10001x, but the classroom in North is good and the classroom in South excellent.2. The uniformity factor of classroom in South is good and that of classroom in North is normal.3. The daylight factor of each classroom is over 5% but the classroom in South is above that in North. The classroom in South surpasses the classroom in North in the general light environment and the classroom in third and fourth floor is so better than that in second and fifth floor in the condition of laboratory In the uniformity factor, the classroom in fourth can be better than any classroom.

  • PDF

Development of Guidelines for Indoor Environment in Apartment Remodeling Projects (아파트 리모델링의 실내환경 계획지침 개발)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The final aim of this study was to propose guidelines for the indoor environment of apartment remodeling projects. The first task of this study was to understand the major elements and the actual condition of the remodeling for apartment unit by carrying out in-depth interviews on residents and specialists. The open-access interviews were conducted with interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment units. The second task was to evaluate the actual condition of the indoor environment and to analyze the main factors that affect the indoor environment in remodeled apartment units. Field measurements were carried out in twenty apartment units occupied after remodeling, recording indoor environment elements (indoor temperature, globe temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, illumination, and equivalent noise level). Moreover, resident interviews and researcher observations were carried out to determine the contents of the remodeled unit and to investigate the architectural and living factors(like ventilation characteristics, etc.) related to the indoor environment. The results are as follows. The remodeling elements generally included the changing of lighting fixtures and finishing materials in all the spaces, the integration of the balcony into the children's room, the installation of furniture in the kitchen and the entrance, the changing storage furnitures and equipments in the bathroom. The average levels of each unit of relative humidity, $CO_2$, TVOC, HCHO, equivalent noise level, and illumination were proved to be on the whole in inadequate condition. The factors that affect these indoor elements were classified as remodeling factors (remodeling amounts, extent balcony integration, and lighting fixture exchange), ventilation characteristics, and living factors. According to these results, this research proposed the guidelines for the indoor environment in apartment remodeling projects.

Light Conditions for Suitable Growth of Urban Interior Plants - In Case of Green House within Kyobo Building, Seoul - (도심 실내조경 식물의 적절한 생육에 필요한 광조건 - 서울시 광화문 교보생명빌딩 그린하우스를 대상으로 -)

  • Lee, Kyong-Jae;Choi, Jin-Woo;Pae, Ho-Bong;Kang, Hyun-Kyoung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.113-124
    • /
    • 2009
  • This study has attempted to calculate the intensity of illumination for the optimal growth environment of indoor plants after analyzing both damage to plant species and growth conditions as impacted by light conditions for the Kyobo Life Insurance greenhouse. The optical intensity of illumination has been estimated after investigating the problems of growth conditions based on an analysis of illumination by light condition, dead tree replacement cycle(weeks) and rate of damage of plant species. According to the investigation of illumination, the lowest difference was observed between the shaded spot in the south(531lux) and the sunny spot(602lux) while the largest difference(nearly 500lux) was detected between the shaded spot in the central area(210lux) and the sunny spot(782lux). According to an analysis of dead trees from 1990 to 2004, in terms of dead tree replacement cycle, Viburnum awabuki was the highest(161weeks), followed by Phyllostachys spp.(84weeks), Camellia japonica and Ternstroemia japonica(40weeks). Regardless of plant species, damage rate of plant were lower in the shaded spot and higher in the sunny spot. According to correlation and regression analyses with the intensity of illumination as an independent variable and the damage rate of plant species as a dependent variable, the damage rate of plant species increased as the intensity of illumination decreased. A dramatic decline in the rate of damage was observed at $500{\sim}600lux$. At 700lux, it reached the lowest level.

A Study on the Actual Conditions of Living Room Lighting in Daegu and Gyeongbuk Districts (대구·경북 지역 거실 조명 실태조사)

  • Jo, Young-Mi;An, Ok-Hee;Kim, Hyun-Jin
    • Journal of the Korean housing association
    • /
    • v.23 no.3
    • /
    • pp.13-20
    • /
    • 2012
  • This research study was conducted to determine the actual conditions of living room lighting in Daegu and Gyeongbuk districts. For this study, 112 households were surveyed. The results of this study are as follows: Firstly, fluorescent light was used as the general illumination of living rooms, and the ratio of not using local sources of illumination was high. Secondly, the standard illuminance was found to be 221. The illuminance was the value that satisfied the activities for togetherness and entertainment, but did not reach the illuminance necessary for other activities, such as reading, make-up, and sewing. In addition, the uniformity of brightness used as a measure of uniformity in examining the results was normal. Thirdly, both the brightness and the satisfaction of lighting in the living room space were indicated to be normal. In addition, in regard to housing lighting, 'stability', and 'brightness of lighting' were indicated as important considerations and 'brightness of lighting', 'shadow' and 'management of lighting' were indicated as problem areas.

A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting (조명기구의 발열부하 저감을 위한 배기풍량 연구)

  • Oh, Byung-Kil;Chung, Min-Ho;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.9
    • /
    • pp.604-609
    • /
    • 2011
  • The increased quality of life requires indoor illumination environment to have illumination with higher intensity. The increase in indoor illumination goes hand in hand with increase in indoor heat load. Of late, the internal heat in the cooling load has been growing gradually and the proportion of the lighting load has been bigger in the cooling load. The objective of the experiment here is to estimate the proper exhaust air flow displacement to remove heat from different types of lighting equipment. The heat causing the cooling load in lighting equipment is the ratio of heat per watt and the ratio of space for heat. Experimental measurements of the constant temperature and humidity in chambers that exhaust air flow by changing the exhaust calorific value was measured. Using the Airflow exhaust heat from lighting fixture of this study should help to reduce House cooling load.

Face Replacement under Different Illumination Condition (다른 조명 환경을 갖는 영상 간의 얼굴 교체 기술)

  • Song, Joongseok;Zhang, Xingjie;Park, Jong-Il
    • Journal of Broadcast Engineering
    • /
    • v.20 no.4
    • /
    • pp.606-618
    • /
    • 2015
  • Computer graphics(CG) is being important technique in media contents such as movie and TV. Especially, face replacement technique which replaces the faces between different images have been studied as a typical technology of CG by academia and researchers for a long time. In this paper, we propose the face replacement method between target and reference images under different illumination environment without 3D model. In experiments, we verified that the proposed method could naturally replace the faces between reference and target images under different illumination condition.