• Title/Summary/Keyword: ignition test

Search Result 467, Processing Time 0.032 seconds

Study on Horizontal and Vertical Temperature Analysis of Cable Fire in Common Duct using Room Corner Experiment (룸코너 실험을 이용한 공동구 케이블 화재 시 수평·수직 방향 온도 분석에 관한 연구)

  • JaeYeop Kim;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.634-643
    • /
    • 2023
  • Purpose: Underground common duct fires are steadily occurring, and the proportion of property damage is particularly large among property and human casualties caused by fires. Especially, cable fires that occur in common areas can spread vertically quickly and pose a great risk. This paper aims to scientifically analyze the nature of the fire by reproducing the fire through experiments. Method: To analyze the characteristics of cable fires in underground common duct, heat release rate and temperature changes were measured through Room-corner (ISO 9705) test, and the vertical and horizontal propagation of cable fires was quantitatively compared and analyzed. Result: The Room Corner Test (ISO 9705) was used to compare the temperature changes at each data logger point. The results showed that the time it took for the fire to reach the ignition temperature in the horizontal and vertical directions from the center point of the first-tier cable was 589 seconds and 536 seconds, respectively, which means that the vertical fire propagation is 53 seconds faster than the horizontal propagation. This proves that the vertical propagation of fire is relatively faster than the horizontal propagation. The horizontal propagation speed of the fire was also compared for each floor cable tray. The results showed that the third-tier cable propagated at 3.4 times the speed of the second-tier cable, and the second-tier cable propagated at 1.5 times the speed of the first-tier cable. This means that the higher the cable is located, the faster the fire spreads and the larger the fire becomes. Conclusion: This study identified the risks of cable fires and analyzed the risks of vertical fire propagation during cable fires based on the results of the Room Corner Test. Studies to prevent the spread of fire and fire response policies to prevent vertical fire propagation are required. The results of this study are expected to be used to assess the fire risk of common areas and other fires.

Analysis of Fire Patterns of Flammable Liquids for Oil Flow Tests of Compartment Fires with Reduced Simulation (축소 모의된 구획 화재의 흘림 실험에 대한 인화성 액체의 화재 패턴 해석)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.43-48
    • /
    • 2014
  • The purpose of this study is to analyze the flame propagation speed, radiation range, diffusion pattern and combustion completion time of a fire by filling a divided space with single combustible substance. It was found that the flame propagation speed was the fastest (0.2 s) for kerosene and the lowest (82.1 s) for alcohol. In the case of paint thinner, it took 19.0 s for the flame to reach its peak at the fastest speed after ignition while in the case of alcohol, it took 138.6 s for the flame to reach its peak at the lowest speed. In the case of the combustion of 200 ml of flammable liquids, the combustion completion time was 79.9 s for paint thinner, which is the shortest, 135 s for gasoline, 170 s for kerosene, 231.4 s for diesel and 337.0 s for alcohol. In addition, when flammable liquids are combusted, the lower part of the flame is governed by laminar flow pattern and the upper part of the flame showed turbulence pattern. In the case of a test performed for bean oil, it could be seen that if the fire source was removed, the flame was automatically extinguished without further combustion and that white smoke was generated due to incomplete combustion.

A Study on the Combustion Characteristics of Synthetic Insulation for Building (건축용 합성 단열재의 연소특성에 관한 연구)

  • Kwon, Hyun-Seok;Lee, Si-Young;Kim, Jong-Buk;Yoon, Myoung-Oh
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.30-37
    • /
    • 2018
  • This study is an analysis of combustion characteristics of synthetic insulation materials such as houses and warehouses. Using combustion cone calorimeter and SEM, the researching has experimented combustion characteristics of four kinds of materials such as flame retardant styrofoam, general styrofoam, urethane and gypsum board. And analyzed. As a result of the test, the ignition time (TTI) for the thermal insulation material was found at 27 s~43 s, and the flame retardant styrofoam was ignited at the lowest TTI at 27 s and disappears at 28 s. In addition, the maximum heat release rate (peak HRR) and average heat release rate (mean HRR) of each material were expressed in the following order: urethane> flame retardant styrofoam> styrofoam> gypsum board. Also, the total smoke release ($m^2/m^2$) was the largest at $30.798m^2/m^2$ in flame-retardant styrofoam. The general CO concentration of styrofoam was 0.275 kg/kg and the emission concentration was 12.807 kg/kg. The residues showed the highest 0.029 g in the gypsum board among the above materials.

The Utilization of Pond Ash as Embankment and Backfill Material (매립된 석탄 혼합회의 성토재 및 뒤채움재로서의 활용에 관한 연구)

  • Kim, Dae-Hyeon;Ki, Wan-Seo;Kim, Sun-Hak
    • The Journal of Engineering Geology
    • /
    • v.20 no.3
    • /
    • pp.297-310
    • /
    • 2010
  • This study represents basic research into the utilization of mixed ash (fly ash and bottom ash) from the ash pond of the Taean Thermal Power Plant as a construction material. We conducted physical and mechanical experiments on the mixed ash and examined its engineering characteristics in terms of its use as a material for road landfill and structure backfill. We evaluated the physical and chemical characteristics of the ash by performing tests to determine specific gravity, maximum and minimum density, liquid limit and plastic limit, grain size distribution, composition (by X-ray diffraction), and loss on ignition. We also evaluated the mechanical characteristics by testing for permeability, compaction, CBR, and tri-axial compression. The experiments on the mixed ash yielded a specific gravity of 2.18-2.20, dry density of $9.38-13.32\;kN/m^3$, modified CBR of 16.5%-21%, permeability coefficient of 1.32 to $1.89-10^{-4}cm/sec$, and drained friction angle of $36.43^{\circ}-41.39^{\circ}$. The physical and mechanical properties of the mixed ash do not meet the quality standards stipulated for road landfill and structure backfill materials. Mixed ash with a high content of fly ash failed to meet some of the quality standards. Therefore, in order to utilize the mixed ash as a material for road landfill and structure backfill, it is necessary to improve its properties by mixing with bottom ash.

A Field Research on Mud Flat Remediation by Biological Treatments (생물학적 처리에 따른 갯벌 복원을 위한 현장 적용성 연구)

  • Cho, Dae-Chul;Bae, Hwan-Jin;Kwon, Sung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3285-3294
    • /
    • 2012
  • A field test on mud flat remediation was carried out in order to observe the effects of the treatments such as microbial dose and an oxygen releasing compound like $CaO_2$. The size of each treatment site was $100m^2$ and the dosage was 3.6 kg per site. The 6 week monitoring showed that pH on two sites was below 7 and ORP increased from .178~-188 mV to .121~-142 mV. In Ignition loss and COD there were no significant changes. Meanwhile nitrogen and phosphorus concentrations changed: ammonia concentration decreased both on control and treatment sites. Nitrate nitrogen decreased more on combined treatment site than on single microbial treatment (11.3% vs. 7.3%) probably because the extra oxygen supplied by $CaO_2$ formed more oxic environment so that the facilitated nitrification might produce more nitrate but the nitrate would be much rapidly released into the water layer out of the sediment. That also explains the total nitrogen reduction(6.1%). Similarly, T-P and $PO_4-P$ reduced by 29% and 31.8%, respectively on combined treatment sites, resulting from the phosphorus release effect though the initial concentrations of the two factors were considerably high.

Improvement of Manila Clam (Ruditapes philippinarum) Habitat Condition by Adding Crushed Oyster (Crassostrea gigas) Shells to the Substratum (굴 패각을 이용한 바지락 양식장 저질개선 효과)

  • Park, Kwang-Jae;Yoon, Sang-Pil;Song, Jae-Hee;Han, Hyun-Seob;O, Hae-Chong
    • The Korean Journal of Malacology
    • /
    • v.27 no.4
    • /
    • pp.291-297
    • /
    • 2011
  • In an attempt to improve the substrate condition for Manila clam (Ruditapes philippinarum) culture, crushed oyster (Crassostrea gigas) shells were spread on the muddy tidal flat of Namseong-ri, Podu-myeon, Goheung-gun, Jeollannam-do in April 2008. To test the suitability of the crushed oyster shell added substrate, seed clams were transplanted from Taehwa river estuary in Ulsan city in June 2008. Over 23 months of sampling, the mean grain size and the sorting in the experimental site containing the crushed oyster shell were significantly higher than the control site. The ignition loss, water content, chemical oxygen demand (COD) and acid-volatile sulfide (AVS) level were also significantly higher in the crushed oyste shell added substratum. Survival of the clams transplanted to the crushed oyster shell added substratum was significantly higher and all the clams transplanted to the normal muddy substratum died in August 2009, 13 months after the transplantation. At the end of the experiment in April 2010, the transplanted clams reached 36.10 mm in shell length and 8.92 g in total weight with survival of 43.5%. Our study suggested than crushed oyster shell added in the mud dominant substratum greatly improved living condition and survivability of clams.

A Study on the Heat Release Characteristics of Fire Load for Performance Based Design of Multiplexes: A Focus on the Heat Release Rate and Fire Spread Rate of Cinema Seats (복합영상관의 성능위주설계를 위한 가연물의 연소발열특성 연구: 객석의자의 열발생률 및 연소확산속도를 중심으로)

  • Nam, Dong-Gun;Jang, Hyo-Yeon;Hwang, Cheol-Hong;Lim, Ohk-Kun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.11-17
    • /
    • 2020
  • As performance-based design (PBD) has a direct impact on evacuation safety assessments, designing fire scenarios based on real fire tests is essential. To improve the reliability of the PBD for fire safety in multiplexes, information on fire behavior, such as heat release rate (HRR) and fire spread rate, are provided in this study by conducting a standard fabric flammability test. To this end, several chairs were arranged in a pattern that resembled a theater-style seating. The peak HRR and heating value per unit mass for each chair ranged from 415 kW to 988 kW and 15.2 MJ/kg to 23.8 MJ/kg, respectively. The heating values per unit mass of the new and old chairs were 23.6 MJ/kg and 16.7 MJ/kg, respectively. As the quantity of plastic and cushioning materials in the new chairs was more than that of the old ones, the new chairs were more vulnerable to fire hazards. Furthermore, when the chairs were arranged in a line, the fire spread rate was observed to be 0.39-0.42 m/min, regardless of the ignition location. Finally, a fire growth curve showing the peak HRR and fire spread rate was also demonstrated.

LPG Cylinder Leak Experiment from Multiple Leak Scenarios (누출종류에 따른 LP가스용기 누출량 실증 실험)

  • Lee, Minkyung;Lee, Kang-Ok;Kim, Young Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2019
  • Unlike NG supplied through pipes, LPG is mainly used for independent storage of cylinders or small storage tanks. As LPG is widely used in islands and underdeveloped areas, accidents due to neglect of safety management are high. Houses and businesses that have LPG accidents are likely to be damaged due to relatively high population density. Therefore, the necessity of strengthening the safety management of LPG is constantly raised. Accordingly, in 1996, Korea Gas Safety Corporation conducted an LPG leak test. In this study, based on the 96-year experiment, the gas leakage measurement of LPG vessels was conducted by adding several conditions such as outside temperature and pipe condition. Through this, the trend of leakage for various scenarios of LPG leakage was examined. In the case of a gas leak, when the article which may affect the pressure such as a regulator is not connected, the leakage amount is greatly changed by the outside air temperature, and when the regulator is fastened, the influence of the outlet pressure is large. It is expected that the experiment can be used as basic data for determining gas accidents and leakages that may occur later.

Characteristics of Vitrification Process for Mixture of Simulated Radioactive Waste Using Induction Cold Crucible Melter (유도가열식 저온용융로를 이용한 혼합모의 방사성폐기물의 유리화 공정 특성)

  • 김천우;양경화;박병철;박승철;황태원;박종길;신상운;하종현;송명재
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.165-174
    • /
    • 2004
  • In order to simultaneously vitrify the ion exchange resin(IER) and combustible dry active waste(DAW) generated from Korean nuclear power plants, a vitrification pilot test was conducted using an induction cold crucible melter(CCM) . The energy necessary for startup of the glass using a Ti-ring was evaluated as about 290 kWh. The power supplied from a high frequency generator to melt the glass properly was ranged from 160 to 190 kW without any interruption. When the mixture of the IER and DAW was fed into the CCM, the concentration of CO was lowered up to 1/40 compared to feeding the IER solely. It may be caused by the DAW which can produce about 1.8 times higher heat compared to the IER. When the swelling phenomenon occurred in the glass melt, the concentration of $NO_2$, oxidizing gas, was higher than NO, reducing gas. Total feed amounts of the IER and DAW were 368 and 751 kg, respectively. And then, about 74 of volume reduction factor was achieved.

  • PDF

Experimental Study on the Self-extinguishing Performance of Extruded Polystyrene Insulation for Buildings and Suggestions on Institutional Management (건축용 압출법 단열판(XPS)의 자기소화성에 대한 실험적 연구 및 제도적 관리에 관한 제언)

  • Kang, Jung Ki;Choi, Don Mook
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.141-149
    • /
    • 2020
  • The Korea Industrial Standards (KS) stipulates methods and test procedures for measuring the horizontal combustibility of cellular plastics exposed to small flames (KS M ISO 9772:2018) and recommendations regarding the magnetic digestion of extruded polystyrene insulation (XPS) for measurement results (KS M 3808:2020). Although products that are certified to conform to KS standards must have burning characteristics (self-extinguishing), they are incinerated and spread by welds at construction sites, causing significant human and property damages. In this study, XPS produced by five companies, certified by KS, and sold in the market were purchased and tested for ignition and diffusion caused by a weld bullion at a construction site. The results showed that the five products had differences in performance. Three out of the five products were found to be self-saturated, but the other two were easily ignited and diffused, making it difficult for them to be self-extinguishing. Based on the result of this experimental investigation in line with the KS regulations, all the three types of products, including two types of products that were incinerated through weld defects, were found to be non-self-extinguishing, as specified in KS M 3808.