• 제목/요약/키워드: ignition location

검색결과 56건 처리시간 0.023초

A Numerical Study of the Backdraft Behavior with the Variation of the Ignition Location and Time (점화원 위치 및 점화시간 변화에 따른 백드래프트 거동에 관한 수치적 연구)

  • Ko, Min Wook;Oh, Chang Bo;Han, Yong Shik;Do, Kyu Hyung
    • Journal of the Korean Society of Safety
    • /
    • 제31권4호
    • /
    • pp.1-8
    • /
    • 2016
  • The behavior of backdraft in the compartment with different ignition locations and times was numerically investigated. The Fire Dynamics Simulator (FDS) v5.5.3 with a model-free simulation option was used in the numerical simulation of backdraft. The ignition source was located near the inside wall, at the compartment center and near the window opening, respectively. The ignition was started at the instance when the fresh air reached the ignition location or when a sufficient time passed compare to the instance of the arriving of the fresh air to the ignition location. As a result, for the ignition source was located near the inside wall, a strong fire ball was observed at once and the result was similar to the previous experimental result. For the ignition source was located at the center of the compartment, a strong fire ball was occurred and two strong fire balls were observed consecutively for the ignition time was delayed. For the ignition source was located near the window opening and longer time was given for the ignition compare the duration of the fresh air arriving to the ignition location, the rapid temperature variation was not observed because there was no flame. However, for the ignition was started at the instance when the fresh air reached the ignition location, the ignition could be initiated and a intensive fire ball was observed. The pressure measured at the upper inside part of the window opening provided a similar trend with the previous experimental result of compartment backdraft.

Experimental study of solid fuel ignition in a confined enclosure (밀폐공간내 복사에 의한 고체연료 점화의 실험적 연구)

  • Kim, Yeong-Gwan;Baek, Seung-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제20권11호
    • /
    • pp.3630-3638
    • /
    • 1996
  • An experimental study has been conducted to explore the behaviors of the radiative ignition of polymethylmetacrylate(PMMA) in a confined enclosure such as the ignition delay time, PMMA surface temperature, the ignition location and the ignition process. In addition, the effects of hot wall orientation on the ignition delay and PMMA surface temperature were studied. When the hot wall is located at the bottom, ignition delay time is the shortest. Ignition surface temperature becomes the lowest for the hot top wall case. These are due to buoyancy effect. Since the radiative heat flux of hot wall is rather lower than laser source, the ignition is considered to be controlled by the mixing process. Therefore, the ignition location, where appropriate mixture of fuel and oxygen exists, occurs near the hot wall. The flame propagates along the hot wall where there exists sufficient oxygen.

Theoretical Analysis on the Hot Surface Ignition of a Rectangular-Shape Solid Fuel

  • Kim, Se-Won
    • Journal of Energy Engineering
    • /
    • 제4권2호
    • /
    • pp.297-302
    • /
    • 1995
  • Ignition of a reactive solid in a shape of square corner by a hot surface is studied theoretically. Ignition time and the location of ignition point are determined as a function of dimensionless parameters, with the use of the homogeneous model of ignition. The effect of geometry on the ignition of solid fuel results in the local characteristics: the reaction is initiated in a hot point in depth of the substance. It is shown that ignition time is proportional to the dimensionless initial temperature, whereas for the ignition of the semiinfinite body this dependence was quadratic.

  • PDF

Monitoring Method for Coal Ignition Temperature using Wi-Fi (Wi-Fi를 활용한 석탄 발화 온도 감시 방안)

  • Hong, Sung-Hwa
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.462-463
    • /
    • 2019
  • The study is a method for preventing the natural ignition of indoor low coal coal in coal-fired power plants. It is a method of monitoring the temperature of coal stored in total by combining Internet technology (IoT) with sensor technology as a location confirmation method to detect the natural ignition of coal in advance and to alarm the location of the ignition site.

  • PDF

Self-ignition of high-pressure hydrogen gas released into tube (튜브내 고압수소가스 누출에 따른 자발점화 현상 유동가시화 연구)

  • Kim, Yeong Ryeon;Lee, Hyoung Jin;Kim, Sei Hwan;Jeung, In Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.247-248
    • /
    • 2012
  • Unidentified self-ignitions were reported when the high-pressure hydrogen gas suddenly leaked out. This paper presents a flow visualization study to investigate the self-ignition mechanism in a test tube how the ignition process is initiated and the flame propagates with measurement of a number of pressure and light sensors installed in the tube supported the analysis of the self-ignition. The test result showed the location of the self-ignition taken place and critical static pressure at the boundary layer for self-ignition.

  • PDF

Flow Direction Characteristics in the Vicinity of the Spark Plug in an S. I. Engine

  • Han, Sung-Bin;Chang, Yong-Hoon;Chung, Yon-Jong
    • Journal of Mechanical Science and Technology
    • /
    • 제14권8호
    • /
    • pp.891-899
    • /
    • 2000
  • The flame speed may be decomposed into the burning speed and the flame transport speed. The flame transport speed is affected considerably by the flow direction, variation rate of flow direction, and flow speed in the combustion chamber. Especially, the flow direction and the variation rate of flow direction at the spark plug location during the ignition period have an important effect on the ignition process and the early flame propagation process. We measured the flow direction component and the variation rate of flow direction with a hot wire probe at the spark plug location. It was shown that the representative flow direction of ignition period is the right-vertical direction of crank shaft and it was used to investigate the variation rate of flow direction.

  • PDF

Ignition and flame propagation in hydrogen-air layers from a geological nuclear waste repository: A preliminary study

  • Ryu, Je Ir;Woo, Seung Min;Lee, Manseok;Yoon, Hyun Chul
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.130-137
    • /
    • 2022
  • In the geological repository of radioactive nuclear waste, anaerobic corrosion can generate hydrogen, and may conservatively lead to the production of hydrogen-air layer. The accumulated hydrogen may cause a hazardous flame propagation resulting from any potential ignition sources. This study numerically investigates the processes of ignition and flame propagation in the layered mixture. Simple geometry was chosen to represent the geological repository, and reactive flow simulations were performed with different ignition power, energy, and locations. The simulation results revealed the effects of power and energy of ignition source, which were also analyzed theoretically. The mechanism of layered flame propagation was suggested, which includes three stages: propagation into the hydrogen area, downward propagation due to the product gas, and horizontal propagation along the top wall. To investigate the effect of the ignition source location, simulations with eight different positions were performed, and the boundary of hazardous ignition area was identified. The simulation results were also explained through scaling analysis. This study evaluates the potential risk of the accumulated hydrogen in geological repository, and illustrates the layered flame propagation in related ignition scenarios.

Ignition of a solid fuel by thermal radiation (열복사에 의한 고체연료 점화 연구)

  • Kim, Myeong-Hyo;Baek, Seung-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제22권3호
    • /
    • pp.294-302
    • /
    • 1998
  • Ignition characteristics of a vertical solid fuel plate with block have been investigated experimentally. For low radiant heat flux, ignition does not occur in a vertical solid fuel plate without block. In the case with the block on a vertical fuel plate, however, ignition can occur by increasing the residence time and the time to absorb the incident radiation flux by fuel vapor in gas phase. The ignition occurs below block and the point varies according to the block location and the block height. As the block height increases, the block locates at higher position, and the hot wall temperature increases, the ignition delay time decreases. Also as the initial temperature of fuel plate rises, the ignition delay time of the solid fuel plate decreases. The temperature distribution of solid fuel plate with block is nearly proportional to the radiant heat flux distribution. Therefore, the effect temperature by natural convection heat transfer is of the same order as that of inhibition of temperature increase by pyrolysis.

Numerical Modeling for Auto-ignition and Combustion Process of Fuel Sprays in High-Pressure Environment (고압 분무 연소장에서 연료 분무의 자발화 및 연소 과정 해석)

  • Yu, Y.W.;Kang, S.M.;Kim, Y.M.
    • Journal of ILASS-Korea
    • /
    • 제5권4호
    • /
    • pp.66-71
    • /
    • 2000
  • The present study is mainly motivated to investigate the vaporization, auto-ignition and combustion processes in the high-pressure engine conditions. The high-pressure vaporization model is developed to realistically simulate the spray dynamics and vaporization characteristics in high-pressure and high-temperature environment. The interaction between chemistry and turbulence is treated by employing the Representative Interactive Flamelet (RIF) Model. The detailed chemistry of 114 elementary steps and 44 chemical species is adopted for the n-heptane/air reaction. In order to account for the spatial inhomogeneity of the scalar dissipation rate, the multiple RIFs are introduced. Numerical results indicate that the RIF approach together with the high-pressure vaporization model successfully predicts the ignition delay time and location as well as the essential features of a spray ignition and combustion processes.

  • PDF

A Study on Safety Assessment of Hydrogen Station (수소충전소의 안전성 평가 연구)

  • PYO, DON-YOUNG;KIM, YANG-HWA;LIM, OCK-TAECK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제30권6호
    • /
    • pp.499-504
    • /
    • 2019
  • Due to the rapid spread and low minimum ignition energy of hydrogen, rupture is highly likely to cause fire, explosion and major accidents. The self-ignition of high-pressure hydrogen is highly likely to ignite immediately when it leaks from an open space, resulting in jet fire. Results of the diffusion and leakage simulation show that jet effect occurs from the leakage source to a certain distance. And at the end of location, the vapor cloud explosion can be occurred due to the formation of hydrogen vapor clouds by built-up. In the result, it is important that depending on the time of ignition, a jet fire or a vapor cloud explosion may occur. Therefore, it is necessary to take into account jet effect by location of leakage source and establish a damage minimizing plan for the possible jet fire or vapor cloud explosion. And it is required to any kind of measurements such as an interlock system to prevent hydrogen leakage or minimize the amount of leakage when detecting leakage of gas.