The fire hazards and combustion heat of puzzle mats in group day care home were analysed using variable external irradiation level. The fire hazards such as ignition time, ignition temperature, mass loss rate, and flame temperature profile were measured. Incident heat fluxes of $15kW/m^2$, $20kW/m^2$, $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $75kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminium foil. Each sample was nominally 20mm thick and 100mm square. Five samples of puzzle mat were tested in the study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. As results, Type E of FR-grade showed the best characteristics in safety of the early fire from ignition time, critical heat flux, and ignition and flame temperature data of this study. All specimen of G-grade(Type A, B and C), however, showed the weak in safety of fire.
Close to high power radio/radar transmitters there is a possibility that sparks may be occur at discontinuities in metallic structures. If these structures are in an area in which a flammable mixture may be present, there is a possibility that a fire or explosion may be caused by the sparking. A number of assessment procedures for quantification of the hazard have been produced. This paper reviews the bases of the British Standard covering ignition hazards by radio-frequency radiation and presents some ignition test apparatus to access these hazards.
In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.
인화점은 가연성 액체의 화재 위험성을 평가하기 위해 사용되는 중요한 특성치 중의 하나이다. 가연성 액체의 상대적인 화재 위험성을 나타낼 수 있는 특성치로서는 열방출속도(HRR), 최대열방출속도(PHRR), 발화지연시간(TTI),질량 감소율, CO및 $CO_2$발생량 등이 있다. 본 연구에서는 가연성 액체의 가연성 액체의 인화점과 화재 특성치와의 관계에 대해서 검토하였다. 이를 위하여 질량 감소율과 TTI를 측정하여 화재 특성치를 계산하였다. 그 결과, 가연성 액체의 인화점과 TTI와 관련된 화재 특성치가 상관성이 매우 높은 것으로 나타났다. 이 결과로부터 가연성 액체 화재의 상대적인 위험성을 평가할 수 있는 파라미터로 사용할 수 있었다.
This study was conducted to assess the hazards of gasoline in relevance to the changes in octane numbers, and gasoline's spontaneous ignition temperature and instantaneous ignition temperature were measured. Spontaneous ignition temperature of regular gasoline was $301^{\circ}C$ for sample quantity of $100{\sim}125{\mu}{\ell}$. Spontaneous ignition temperature of middle gasoline was $380^{\circ}C$ for sample quantity of $125{\mu}{\ell}$ and that of premium gasoline was $400^{\circ}C$. As gasoline's octane numbers increased, their spontaneous ignition temperatures increased, and their instantaneous ignition temperature were almost identically $499^{\circ}C$ for sample quantity of $125{\mu}{\ell}$. In addition, activation energies of regular gasoline, middle gasoline, and premium gasoline were 10.48 Kcal/mol, 16.89 Kcal/mol, and 24.55 Kcal/mol respectively.
With a progress of electrical and electronic technology, radio-frequency including high frequency components are widely to various industrial installations. Some of them are used in hazardous locations where explosive or flammable gases exist. As a result, ignition of such gases may be induced by a spark discharge when the radio frequency circuits are switched on or off. The purpose of this study is to investigate the ignition hazards of some kind of flammable mixtures based on the IEC 60079-11 publication. In this experiment, we used a high frequency resistive circuit which consists of a co-axial cable, a 20 ${\Omega}$, 30 ${\Omega}$, 40 ${\Omega}$ and 50 ${\Omega}$ resistor and two kind of power amplifier with frequency range up to almost 1 MHz and 50 MHz. Experimental results show that the ignition of the acetyleneair, ethylene-air mixtures and methane-air mixtures due to spark discharge depends primarily on the frequency of the power source in the resistive circuit the minimum ignition voltage increases gradually with the increase of the frequency.
With a progress of electrical and electronic technology, radio-frequency circuits including high frequency components are widely applied to various industrial installations. Some of them are used in hazardous locations where explosive or flammable gases exist. As a result, ignition of such gases may be induced by a spark discharge when the radio frequency circuits are switched on or off. The purpose of this study is to investigate the ignition hazards of acetylene-air and ethylen-air mixtures experimentally based on the IEC 79-3 publication. In this experiment, we used a high frequency resistive circuit which consists of a co-axial cable, a $10{\Omega}$, $20{\Omega}$, $30{\Omega}$, $40{\Omega}$ or $50{\Omega}$ resistor and a power amplifier with frequency range up to almost 1 MHz. Experimental results show that the ignition of the acetylene-air and ethylen-air mixtures due to spark discharge depends primarily on the frequency of the power source in the resistive circuit: the minimum ignition voltage increases gradually with the increase of the frequency.
A large amount of electrostatic charges is often generated on polymer powders in fluidized bed and thereby may lead to electrostatic problems. In this study, to evaluate electrostatic hazards of powder in fluidized bed, the electric field(E[v/m]) and the charge amount(q[c/g]) during fluidizing were monitored. We also investigated the Minimum Ignition Energy(MIE [J]) of sample powder used in fluidized bed with the Hartman vertical-tube apparatus. The batch-type fluidized bed system and 2kg as Polypropylene(PP) resin powders were used in the experiments. The following results were obtained: (1) Even when a safe margin of several times was considered, the values of E obtained with PP powder in this paper did not exceed 3 to 5kV/cm, at which an incendiary electrostatic discharge could occur. (2) the ave. q was -0.26${\mu}$C/g during fluidizing. This value was high enough to cause electrostatic agglomeration and adhesion. (3) the entrained PP powder in upper column due to fluidizing could be ignited by electrostatic discharges of 71mJ.
Electrostatic eliminators are essential in various areas of manufacturing industries to protect electrostatic hazards and to reduce inferior products. For ion sources used in the charge neutralizers, there are corona discharge, soft X-ray, and ultraviolet and glow discharge. Among them, corona discharge is generally used, because the corona discharge can easily and economically produce positive and negative ions including electrons in air at atmospheric pressure. But it is necessary to equip explosion-protection electrostatic eliminators wherever hazardous atmosphere. The electrostatic eliminators and their testing method of explosion-protection type have been developed in this research. The contents and scope of the research as follows; developing the type 'Ex s IIB T4' electrostatic eliminator of explosion-protection; developing the type 'Ex s d IIB T4' electrostatic eliminator of explosion-protection; developing the explosion-protection performance testing method of electrostatic eliminator for using AC power source.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.