• 제목/요약/키워드: ignite

Search Result 134, Processing Time 0.021 seconds

A Study on the Adaptability of Oxygen Reduction System to Fire in Cold Storage through Fire Simulation Analysis (화재시뮬레이션 분석을 통한 냉장·냉동 창고 화재의 저산소 시스템 적응성에 관한 연구)

  • Min-Seok Kim;Sang-Bum Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.117-127
    • /
    • 2023
  • Purpose: The number of Cold Storages at home and abroad is on the rise, fires in large Cold Storages have recently occurred. As fires continue to occur and property damage is on the rise every year, the importance of preventing fires in large Cold Storage is growing. Method: Real Cold Storages were investigated on-site and fire cases were analyzed to derive and analyze fire risk, and the ORS, which is emerging as an adaptive fire prevention technology of Cold Storage, was investigated through FDS. Result: oxygen concentration 21, 15.7% and 17.7, 16.7% were analyzed through FDS, and flashover was reached within 3~4 minutes from 21, 17.7, 16.7%, but if oxygen concentration was lowered to 15.7%, it didn't ignite for 13 minutes. Conclusion: This study understood the concept and general part of the ORS, modeled the freezer through FDS, and analyzed the oxygen concentration to analyze the fire protection adaptability of the ORS. In the future, it is expected that large-scale empirical experiments and related regulations will be prepared to provide solutions for fire prevention in Cold Storages in blind spots of fire.

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

Preparation and physical properties of flame retardant high density polyethylene utilizing inorganic waste shell powder (재활용(再活用) 굴 껍질 분말(粉末)을 이용(利用)한 고밀도 폴리에틸렌계 난연 소재(素材)의 제조(製造)와 물성(物性))

  • Choi, Jae-Won;Cho, Tae-Keun;Ahn, Jun-Hyung;Lee, Sung-Ho;Chung, Yong-Chan;Jeon, Ho-Seok;Chun, Byoung-Chul
    • Resources Recycling
    • /
    • v.17 no.4
    • /
    • pp.21-29
    • /
    • 2008
  • Waste shell powder was added to the high density polyethylene(HDPE), and resultant mechanical properties and flame retardancy were analyzed in terms of shell content. Compatibilizer(PE-g-MA) was used to enhance the mechanical properties of the prepared HDPE/shell composites, and several flame retardant agents($Al_2O_3$, $Sb_2O_3$) were utilized to improve flame retardancy. Addition of the compatibilizer resulted in an improved mechanical properties due to the increased interfacial bonding between HDPE matrix and shell powder. In the case of impact strength, it even reached to the impact strength of pure HDPE. Also the addition of the flame retardant agents did not exhibit mechanical property decrease. UL-94 flammability test on the prepared HDPE/shell composites indicated that at 40wt% of shell only inclusion, time to ignite the flame and the total time of flame duration increased. When flame retardant agents mixed with shell powder were added to the HDPE matrix, improved flame retardancy was observed. Generally, flame retardancy effect of $Al_2O_3$ was better than $Sb_2O_3$. UL-94 V-0 classification was observed for the specimens with $Al_2O_3$ and compatibilizer at more than 40wt% shell, and also for specimens with $Sb_2O_3$ and compatibilizer at all shell content.

Effects of Fire Retardant Treatment on Mechanical Properties and Fire Retardancy of Particleboard and Complyboard (내화처리(耐火處理)가 파아티클보오드와 콤플라이보오드의 기계적성질(機械的性質) 및 내화도(耐火度)에 미치는 영향(影響))

  • Kwon, Jin-Heon;Lee, Phll-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.3-57
    • /
    • 1985
  • This research was conducted to examine the feasibility of developing fire retardant particleboard and complyboard. Particleboard were manufactured using meranti particle(Shorea spp.)made with Pallmann chipper, and complyboard meranti particle and apitong veneer (Dipterocarpus spp.). Particles were passed through 4mm (6 mesh) and retained on 1mm (25 mesh). Urea formaldehyde resin was added 10 percent on ovendry weight of particle. Face veneer for complyboard was 0.9, 1.6 and 2.3mm in thickness and spread with 36 g/(30.48 cm)$^2$ glue on one side. Veneers were soaked with 10 percent solution of five fire retardant chemicals (diammonium phosphate, ammonium sulfate, monoammonium phosphate, Pyresote and Minalith), and particles with 5, 10, 15 and 20 percent solution of five chemicals. Particleboard and complyboard were evaluated on physical and mechanical properties, and fire retardancy. The results obtained were summarized as follows. 1. Among five fire retardant chemicals treated to particleboard and complyboard, the retention of ammonium sulfate in 5 percent solution showed the lowest as 1.39 kg/(30.48 cm)$^3$ exceeding the minimum retention of 1.125 kg/(30.48 cm)$^3$ recommended by Forest Products Laboratory and Koch. 2. Particleboard and complyboard treated with diammonium phosphate showed higher modulus of rupture (MOR), modulus of elasticity (MOE), internal bond strength and screw holding power than those with the other chemicals. 3. MOR and MOE of complyboard treated with fire retardant chemicals were greater than those of fire retardant particleboard. 4. Thickness swelling of fire retardant complyboard was lower than that of fire retardant particleboard. 5. The moisture content of the boards treated with Pyresote and Minalith increased and with monoammonium phosphate reduced. 6. Fire retardant particleboard showed no ignition, and fire retardant complyboard started ignition, but time required to ignite was prolonged comparing the controlboard. Complyboard with only shell veneer treated showed ignition and lingering flame, but lingering flame time was shorter than controlboard. Complyboard with treated both core and veneer showed ignition but not lingering flame. 7. Flame length, carbonized area and weight loss were smaller than controlboard but had no significant difference among chemicals treated. 8. Temperature of unexposed surface of fire retardant particleboard was lowered with the increasing concentration of five chemicals. 9. Temperature of unexposed surface of fire retardant particleboard was lowered with the highest in Pyresote and the lowest in Minalith. 10. Temperature of unexposed surface of fire retardant complyboard was lower than that of controlboard.

  • PDF