• 제목/요약/키워드: ice-storage system

검색결과 173건 처리시간 0.019초

다성분계 수용액의 교반/냉각에 의한 빙부착 (Adhesion of Ice Slurry in a Multi-component Aqueous Solution with Stirring and Cooling)

  • 강채동;강용태;홍희기
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1063-1070
    • /
    • 2002
  • To resist ice adhesion on cooling wall is concerned to continuous ice formation in thermal storage system. In this study, ice slurries were formed with two ecological aqueous solution, one is ethanol+silanol and the other is propylene glycol+silanol. By freezing under stirring the solution of $300m\ell$ in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, the shape of ice slurry and the strength of ice adhesion on wall was observed with measuring the temperature and stirring load variation. As the concentration is smaller and the supercooling degree is larger, the ice adhesion is easy to occur. When the stirring load is larger than$ 2.1\times10^{-5}W$, the ice adhesion occurred.

부분축열식 빙축열시스템의 냉방에너지소비 절약을 위한 냉동기 On-Off 제어기법의 평가 (Evaluation of Chiller On-Off Control of Partial Ice Storage System for Energy Saving in Cooling Operation)

  • 이경호;최병윤;이상렬;한승호
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2000년도 춘계 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 2000
  • This paper describes an operation strategy of ice storage systems for energy saving during building cooling. In this study, chiller is assumed not having function of part load control. Thus, it is needed to adopt on-off control with the objective function of summed energy consumption for minimum energy consumption. A conventional control strategy compared with the chiller-on-off control is chiller-priority control. in this control chiller operates as its full capacity and ice storage meets the rest of the cooling load.

  • PDF

빙축열조의 방냉과정에 대한 해석 (Analysis on the Coldness Release Process of Ice Storage Tank)

  • 유호선;김영인
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.9-20
    • /
    • 1989
  • This paper presents an analysis to predict thermal behaviors of water in ice storage tank during the coldness release process. To deal with complicated transient phenomena due to ice-water phase change and the density inversion, a theoretical model which consists of initial perfectly mixed, stratified and thermal diffusion state was introduced and a criterion on the growth of thermal boundary layer was developed. The analysis includes considerations on the type of ice-making heat exchanger, refrigerator on/off and tank arrangement. Also, discussions on the various parameters and operating conditions which have influence on the performance of the system were made. Finally, simulated results were shown, which agreed with experiments in trends reasonably.

  • PDF

드럼형 증발기를 적용한 2단 압축 해수 제빙시스템의 성능 특성 (Performance Characteristics of Two-stage Compression Seawater Ice Machine Applied Drum type Evaporator)

  • 손창효;윤정인;전민주;이현경;허성관
    • 동력기계공학회지
    • /
    • 제21권2호
    • /
    • pp.77-82
    • /
    • 2017
  • In the fishing boat, freshwater ice is loaded on the fishroom in advance and it is used for storage of fishes. However, it causes degradation of catches' freshness. Therefore, seawater ice machine on board is necessary for the fishing industry. In this study, seawater ice machine with drum type evaporator was manufactured, and the system was tested under various operating conditions having an influence on the COP and amount of ice produced. The main results are as follow : The COP of the system gets larger when the evaporation temperature and rotation speed of the drum in the evaporator increases. The most effective refrigerant is R22 and the value of the COP was 1.43 times higher than that of R404A. The amount of produced ice increases with respect to increment of the evaporation temperature, while that decreases with respect to increment of the evaporator drum rotation speed.

온도, 습도 및 냉방부하 예측에 관한 연구 (A Study on the Estimation of Temperature, Humidity and Cooling Load)

  • 유성연;한승호;이제묘;한규현;노관종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.80-85
    • /
    • 2006
  • The peak demand of electricity in summer season mainly comes from the day time cooling loads. Ice thermal Storage System (ITSS) uses off-peak electricity at night time to make ice for the day time cooling. In order to maximize the use of cold storage in ITSS, the estimation of day time cooling load for the building is necessary. In this study, we present a method of cooling load estimation using 5 years of normalized outdoor temperature, relative humidity, and the building construction data. We applied the hourly-based estimation to a general hospital building with relatively less sudden heat exchange and the results are compared with the measured cooling load of the building. The results show that the cooling loads estimation depends on the indoor cooling design temperature of the building.

  • PDF

고흡수성고분자가 조핵제로 첨가된 빙축열용 축열재 개발 (An Evaluation of a super-absorbent polymer as the Nucleating Agent for a Capsule-type Ice Storage System)

  • 최형준;홍성안;박원훈
    • 태양에너지
    • /
    • 제10권2호
    • /
    • pp.28-37
    • /
    • 1990
  • 빙축열의 문제점인 물의 과냉각을 억제 또는 제거하기 위하여 고흡수성 고분자를 조핵제로 사용하는 방법이 고안되었다. 축열재인 물을 $25^{\circ}C$에서 $-12^{\circ}C$로 냉각시킨 결과 순수한 물의 경우 샘플중 25%의 샘플은 전혀 결빙되지 않았으며 나머지 얼음이 생성된 샘플의 경우도 평균 $9.8^{\circ}C$의 과냉각을 보인 반면, 조핵제가 첨가된 경우 35%가 전혀 과냉각을 보이지 않았으며 과냉각이 일어난 샘플의 평균과 냉각온도 역시 현저히 감소되었다. 0.5wt%의 고흡수성 고분자가 첨가된 축열재를 사용하여 캡슐타입으로 제작한 축열조에서 열전달 실험을 실시한 결과 과냉각은 전혀 관찰되지 않았으며 이로 인하여 순수물을 축열재로 사용하는 경우보다 축열속도가 증가하였다. 이상의 결과로부터 고흡수성 고분자가 빙축열 시스템의 조핵제로 사용될 수 있음을 확인하였다.

  • PDF

다양한 아이스 볼 형상에 대한 복합열전달의 수치해석 (Numerical Analysis of Conjugate Heat Transfer for Various Ice-Ball Shapes)

  • 박서원;김명수;전병진;최형권
    • 대한기계학회논문집B
    • /
    • 제40권9호
    • /
    • pp.605-612
    • /
    • 2016
  • 본 연구에서는 캡슐형 빙축열시스템에 적용되는 다양한 형상들을 가지는 아이스 볼에 대한 복합열전달 해석들을 수행하였다. 형상은 구 형상과 열전달 표면적을 넓힐 수 있도록 설계한 3가지 다른 형상을 포함하여 총 4가지 형상을 고려하였다. 볼 주위의 유동은 레이놀즈 수 300의 층류 유동으로, 볼 외부와 내부의 강제대류 및 자연대류를 고려하여 시뮬레이션을 수행하였다. 상용해석 코드인 ANSYS- FLUENT를 사용하여 비정상 열유동 해석을 수행하였다. 볼의 형상이 열전달에 미치는 영향을 고찰하여, Bone, Dimple, Hole, Sphere 형태 순으로 열전달 효율이 좋음을 확인하였다. 전체해석 기간 동안에 캡슐 내부 유체의 평균온도 차이는 최대 $0.9^{\circ}C$정도였다. 대용량 시스템의 경우 축열조 내에 30만개 이상의 캡슐이 들어가므로 캡슐 형상이 시스템 효율에 미치는 영향이 중요함을 확인하였다.

수용액의 교반/냉각을 동반한 슬러리 얼음의 빙부착 (Adhesion of Ice Slurry in an Aqueous Solution Cooling with Stirring)

  • 강채동;손권;백종현;홍희기
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1071-1077
    • /
    • 2002
  • Ice adhesion on cooling wall is very important in continuous ice formation. The purpose of the present study is to investigate the possibilities of a three-component aqueous solution as a thermal storage material for the continuous ice formation. By freezing under stirring the solution of 300 mL in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, an ice slurry was formed experimentally with measuring the temperature and stirring load variation. From the experiment, the ice adhesion was suppressed when the supercooling degree decreased and the concentration of aqueous solution increased.

IDENTIFICATION OF THERMODYNAMIC PARAMETERS OF ARCTIC SEA ICE AND NUMERICAL SIMULATION

  • Xiw, Chao;Feng, Enmin;Li, Zhijun;Peng, Lu
    • Journal of applied mathematics & informatics
    • /
    • 제26권3_4호
    • /
    • pp.519-530
    • /
    • 2008
  • This paper studies the multi-domain coupled system of one dimensional Arctic temperature field and establishes identification model about the thermodynamic parameters of sea ice (heat storage capacity, density and conductivity) by the so-called output least-square estimate according to the temperature data acquired by a monitor buoy installed in the Arctic ocean. By the optimal control theory, the existence and dependability of weak solution and the identifiability of identification model have been given. Moreover, necessary optimality condition is proposed. Furthermore, the optimal algorithm for the identification model is constructed. By using the optimal thermodynamic parameters of Arctic sea ice, the numerical simulation is implemented, and the numerical results of temperature distribution of Arctic sea ice are demonstrated.

  • PDF

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2011
  • 2중관형과 판형 열교환기에 에틸렌 클리콜-물 수용액으로 만들어진 아이스슬러리를 적용하는 경우의 유동 및 열적 특성을 규명하기 위하여 실험을 수행하였다. 아이스슬러리의 질량유속과 얼음 분율은 각각 800에서 3500 kg/$m^2s$과 0에서 25%이었다. 실험을 통해, 압력강하와 열전달율은 질량유속과 얼음 분율에 따라 증가하였다. 그러나 얼음 분율의 효과는 높은 질량유속 영역에서는 크지 않은 것으로 나타났다. 낮은 질량유속에서는 압력강하와 열전달율의 급속한 증가가 질량 유속에 관계되는 것으로 나타났다.