• Title/Summary/Keyword: iEMG

Search Result 106, Processing Time 0.023 seconds

Design Improvement of the Smith Machine using Simulation on Musculoskeletal Model

  • Kim, Taewoo;Lee, Kunwoo;Kwon, Junghoon
    • International Journal of CAD/CAM
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • This study analyzes the characteristics of two different kinds of squat exercise through physical experiments and a computer simulation, i.e. one with a free weight and the other with a Smith machine are studied. This study also proposes a new design for the Smith machine, which has both the advantages of each type based on the results of the analysis. The muscle force and level of stimulation of the lower extremities during squatting were calculated by running an inverse dynamics analysis program on a musculoskeletal model together with the measured motion data. The calculated results were verified by comparing with the measured EMG data. The analysis showed that squatting using free weight is more effective than squatting using the Smith machine. Meanwhile, in order to design an improved Smith machine, which is the final goal of this study, the trajectory of the barbell of the subjects during free weight squatting was measured on the sagittal plane. The measurement showed that the average slope of the trajectory of the barbell is tilted backward by $10.7^{\circ}$. Based on this measurement, this study proposes a tilted design for an improved Smith machine.

Effects of Different Types of Attentional Focus on Dart Throwing Mechanics (주의 집중 방법이 다트 던지기 역학에 미치는 영향)

  • Kim, Hye-Ree;Kong, Se-Jin;Kim, Soo-Yeon;Lee, Ki-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.327-333
    • /
    • 2013
  • The purpose of this study was to investigate the effects of different types of attentional focus(internal focus vs. external focus) on the dart throwing mechanics. Seven expert dart throwing athletes were assigned to an internal focus group and other seven athletes were assigned to an external focus group. Each group was asked to throw dart either under verbal instruction or without instruction. During dart throwing, accuracy(radial error), consistency(bivariate variable error), dart velocity, acceleration, elbow joint ROM, elbow joint angular velocity, EMD(electromechanical delay), iEMG of biceps brachii and triceps brachii, and CI(coactivation index) were collected and analyzed. Nither instruction type nor instruction itself affected in accuracy and consistency. However, in dart velocity and acceleration, there was an interaction between instruction and attentional focus types. Velocity and acceleration increased in the internal condition, where as they decreased in the external condition. The ROM of elbow joint did not affected by instruction and attention type. However, similar to dart velocity and acceleration, angular velocity increased in internal focus group, while it decreased in external focus group. EMG showed no difference with any condition. In conclusion, internal focus is better than external focus for dart throwing.

Effect of Acute Aquatic Plyometric Training on Muscle Strength, Edema and Pain

  • Kim, Byung Kwan;Jeong, Hwan Jong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.224-232
    • /
    • 2022
  • The purpose of this study was to investigate the pre- and post-exercise performance, edema, and pain of plyometrics in water and land environments. Twelve males in their 20s were selected as subjects and performed 10 sets of squat jumps 10 times in 2 environmental conditions (water and ground). There was no significant difference in iEMG of vastus medilais according to exercise conditions and time. In MPV of CMJ, there was no significant difference according to exercise conditions and time. The thigh circumference showed a significant difference according to the exercise condition and time, and was higher in the ground condition after exercise. There was a significant difference in pain according to the exercise condition and time, and it was found to be high after exercise, 48 hours, and 72 hours in the ground condition. We believe that plyometric training in an aquatic environment will have less swelling and pain compared to plyometric training conducted in a land environment, and the pain will improve quickly, so we think that training can be conducted in a relatively shorter period than in the land environment.

Changes in Median Frequency of Quadriceps Muscle According to Application Modes of Neuromuscular Electrical Stimulation (신경근전기자극 적용양식에 따른 대퇴사두근의 중앙주파수 변화)

  • Choi, Soo-Hee;Oh, Myung-Hwa;Kim, Tae-Youl;Jeong, Jin-Gyu
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.3 no.1
    • /
    • pp.49-59
    • /
    • 2005
  • This study assigns each 8 of 24 normal persons to control group(Group I), strength increase group(Group II) and endurance increase group(Group III) to analyze differences in changes of strength and endurance with surface electromyography and kinetics according to application modes of neuromuscular electrical stimulation(NMES). Group I had not any treatment, group II performed 15 repeated contraction with 60% intensity of maximal voluntary isometric contraction(MVIC) by setting 10-sec on time and 50-sec off time and group III conducted 30 repeated contraction with 30% intensity of MVIC by setting 10-sec on time and 20-sec off time. For neuromuscular electrical stimulation, 2,500 Hz of Russian current, 35 pps of pulse rate and 200 of pulse width. Neuromuscular electrical stimulation was conducted by five times for total 4 weeks. Before and after experimentmotor unit action potential of vastus medialis, rectus femoris and vastus lateralis were measured with sEMG, median frequency(MDF) was analyzed, and thus the following results were obtained. There was significant difference in the period of measuring vastus medialis and rectus femoris in change of MDF and interaction among groups with analysis of surface electromyography before and after neuromuscular electrical stimulation(p<.001) and in particular, there was a remarkable change among groups according to the period of measurement. In conclusion, NMES influenced changes of strength and endurance according to its application modes and in particular, it was found that strength increment application had a significant influence on strength increment in applying short-time NMES.

  • PDF

Effects of Electroacupuncture on the Visceromotor Response to Colonic Distension in TNBS-Induced Colonic Inflammation in Rats (흰쥐의 TNBS 유발 대장염에서 전침(電鍼)의 대장(大腸) 흥분성(興奮性)에 미치는 효과(效果))

  • Choi, Yun-Young;Ahn, Sung-Hun;Kwon, Oh-Sang;Seo, Sang-Rok;Sohn, In-Chul;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.91-108
    • /
    • 2009
  • Objectives: Single colorectal instillation of trinitrobenzenesulphonic acid (TNBS) causes a dose-dependent increase of visceral motor response (VMR) and severity of inflammation. In this study we compared the effects of electroacupuncture in the different acupoints in the acute colitis induced by TNBS intracolonic injection in rats. Methods: In Male Sprague-Dawley rats, weighing $250{\sim}400g$, a single colorectal administration of TNBS 5mg/kg and 50% ethanol under isoflurane anaesthesia after an overnight fast. Electrodes for electromyography (EMG) recording were stitched into the external oblique musculature under general anesthesia. Acupoints of LI4, ST25, or ST36 were stimulated by electroacupuncture, respectively. The balloon was inserted intra-anally and visceral motor response (VMR) to colorectal distensioin (CRD) was quantified with an EMG recording system. Results: At an observation of the visceral hyperalgesia in the day-time series, the visceromotor response increased significantly 3 days after TNBS intra-rectalcolonic injection in rats. Electroacupuncture on either ST25 or ST36 suppressed the visceromotor response to colorectal distension, but not LI4, at 3 days after TNBS injection. Pretreatment of naltrexone (10 mg/kg, i.p.), opioids antagonist, inhibited the VMR suppress of 10Hz EA to ST36 but not phentolamine (5 mg/kg, i.p.). Pretreatment of either naltrexone or phentolamine inhibited effects of 10Hz EA to ST25. Conclusions: Data show that EA at either ST25 or ST36 potently inhibits hypersensitivity of colorectum after TNBS induced colitis and is differently mediated through the endogenous opioid system and adrenergic system.

  • PDF

A STUDY ON MASTICATORY PERFORMANCE AND MUSCLE ACTIVITY IN REMOVABLE PARTIAL DENTURE WEARERS (자연치열자와 가철성 국소의치 장착자의 저작효율과 근활성도에 관한 비교 연구)

  • Paik, Jin;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.81-103
    • /
    • 1998
  • The purpose of this study was to compare and evaluate the differences in masticatory performance, muscle activity, and patterns of occlusal contact between persons with natural dentition and removable partial denture wearers. Twenty healthy adult subjects with more than 28 teeth and thirteen removable partial denture wearers that classified Kennedy classification I was selected. The degree of pulverized rice and peanut was measured and analyzed by means of sieving method to compare the masticatory performance. For the muscle activity, EMG was recorded in selected muscles(Temporalis and masseter muscle) during mastication and resting state. The occlusal record in maximal intercuspation was taken with a silicone occlusal bite registration material for analysis of the patterns of occlusal contact. The obtained results were as follows: 1. When chewed peanuts, masticatory performance ratio at 10-sieve size was 81.31% in natural dentition group. In removable partial denture wearer, 27.01% without RPD and 69.09% with RPD. When chewed rice, 42.04%, 11.87%, and 21.58%, respectively. The differences of masticatory performance ratio between groups were statistically significant at the 0.05 level. 2. The mean EMG value in resting state was $1.06{\mu}V$ on temporal muscle, $0.98{\mu}V$ on masseter muscle in natural dentition group. In removable partial denture wearers, $1.13{\mu}V$ on temporal muscle, $1.05{\mu}V$ on masseter muscle without RPD and $1.11{\mu}V$ on temporal muscle, $1.04{\mu}V$ on masseter muscle with RPD. 3. The mean EMG value during mastication was $45.64{\mu}V$ in natural dentition group, and in removable partial denture wearers, $22.06{\mu}V$ without RPD and $31.01{\mu}V$ with RPD when chewed peanuts. When chewed rice, $45.24{\mu}V,\;25.53{\mu}V\;and\;32.14{\mu}V$, respectively. The differences of mean masticatory EMG value between groups were statistically significant at the 0.05 level. 4. The number of posterior occlusal contact point was 20.15 in natural dentition group and 11.92 in removable partial denture wearers. The area of perforated surface was $16.50mm^2$ in natural dentition group and $6.06mm^2$ in removable partial denture wearers. The area of contact surface was $78.93mm^2,\;51.52mm^2$, respectively. 5. The area of contact surface was effective to masticatory performance ratio in natural dentition group and removable partial denture wearers (p<0.05). From these results, it is concluded that in partially edentulous patient, masticatory efficiency can be improved by removable partial denture wearing, and for efficient mastication, tight occlusal contact surface shoud be maintained by maximum support that is provided from mucosa.

  • PDF

Effects of Yanghyuljanggeungunbo-tang(Yangxuezhuangjinjianbu-tang) and Electrical Acupuncture on the Spinal Nerve Injury and the Motor Function (양혈장근건보탕(養血壯筋健步湯)과 전침의 병용치료가 손상된 척수신경 및 운동기능에 미치는 영향)

  • Sul, Jae-Uk;Chu, Min-Kyu;Kim, Sun-Jong;Choi, Jin-Bong;Shin, Mi-Suk;Kim, Soo-Ik
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.2
    • /
    • pp.1-25
    • /
    • 2009
  • Objectives : The purpose of this study was to investigate the effects of Yanghyuljanggeungunbo-tang(Yangxuezhuangjinjianbu-tang, YGKT) and electrical acupuncture treatment in spinal cord injury(SCI)-induced rats. Methods : The subjects were divided into 5 groups ; Normal, Control-no treatment after SCI, Experimental I(Exp. I)-taken with YGKT 500 mg/kg $0.5m{\ell}$ daily after SCI. Experimental II(Exp. II)-taken with electrical acupuncture after SCI and Experimental III(Exp. III)-taken with YGKT 500 mg/kg $0.5m{\ell}$ and electrical acupuncture after SCI. After each operation, the present author observed cytological changes, the motor behavior recovery and nerve regeneration by analysis of the motor behavior tests, EMG, hematological(AST, ALT, WBC), histological and immunological changes. Rats were tested by Motor behavior test at 1st, 3rd, 7th, 14th and 21st day. Results : 1. All the experimental groups were improved compared with control group in the motor behavior tests including Tarlov test, Basso-Beattle-Bresnahan locomotor rating scale, modified inclined plane test, open field test, grid walk test and narrow beam test. Especially Exp. III was significantly improved among other groups. 2. In EMG test, H and M wave were significantly increased in Exp. III. 3. All the experimental groups were significantly decreased compared with control group in AST, ALT and WBC. 4. NGF, BDNF and Trk B of spinal cord gray matter in all the experimental groups were increased compared with control group. Especially, Exp. III was more effective. 5. In histological observations, muscle contraction and denaturation of gastrocnemius muscle of all the experimental groups were inhibited. Especially, those of Exp. III was more effective. On the observations of liver and kidney, cell atrophy and apoptosis of all the experimental groups were decreased compared with control group. Especially, those of Exp. III was more effective. Conclusions : It can be suggested that YGKT and electrical acupuncture may improve motor behavior, EMG, hematological, histological and immunological findings in SCI-induced rats. Especially, combination of these two treatments will be somewhat better in spinal nerve recovery and motor function improvement.

The Effects of Knee Muscle Taping Therapy on Parameter of Muscle Activities (슬관절 근육 테이핑요법이 근활성도에 미치는 영향)

  • Yang, Kyung-Han;Choi, Chan-Ho;Yoo, Wang-Keun
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.11 no.2
    • /
    • pp.121-132
    • /
    • 2007
  • The purpose of this study is to find out the effects of taping therapy on muscle activities between the group of taping therapy treatment and control group before or after exercises. The subjects are 18 S college's healthy male students who do not have any problems in the legs and could bend the knee joint normally. Considering physique, condition of health and capacity for locomotion, 3 groups of each 6 persons for the experimentation were classified. Three groups composed of control group without taping therapy treatment for control group, group I with taping therapy treatment only before the experimentation and group II with taping therapy treatment during 24 hour. before and after the experimentation. EMG MP150 was used to evaluate the parameter of the lower leg's muscle activities the exercise before 5 min. after 10 min. and after 24 hour. for the experimentation. Compared with control group, group I and group II had more increased muscle activities in vastus lateralis and rectus femoris and was statistically significant. And group I and group II also had more increase in muscle activities than control group in vastus medialis, although there was no statistically significant. We found that taping therapy increased muscle activity positively. The application of taping therapy could be used not only for preventive effects for sports man but also therapeutic effects for general people.

  • PDF

Are Lighter Smartphones Ergonomically Better?

  • Yoon, Jangwhon;Kim, Kisong;Yoon, Taelim
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • Objective: The aim of this study was to understand the effects of phone weight on the typing performance and muscle recruitment in the neck and upper extremity while typing a text message with dominant hand. The iPhone4 and iPhone5 were compared due to their 28-gram differences in weight. Background: Too much use of a cellular phone can lead the musculoskeletal disorders in the upper extremity. Phone makers tend to make their new models bigger, lighter, faster and smarter. Method: Fourteen healthy volunteers without any history of neuromuscular disorders or ongoing pain who used their smartphone more than one year were recruited. A 112g phone (iPhone5) and a 142g phone (iPhone4) were used for typing the lyric of the Korean national anthem with their dominant hand. Typing duration, the typing error, the perceived fatigue, and preference was investigated. Muscle recruitment and the resting gap of neck (middle trapezius and levator scapula), shoulder (infraspinatus and mid deltoid), elbow (biceps brachii and brachioradialis), thumb (extensor and abductor policis brevis) were collected using surface electromyography. Typing error was counted and typing speed was calculated in characters per min. The data were analyzed using a paired t-test and chi-square (${\chi}^2$) analysis for the effects of phone weight on the typing performance parameters and muscle recruitment. Results: Typing text message with iPhone5 took longer but had less muscle recruitment in brachioradialis, and extensor policis brevis muscles. Lighter weight of iPhone5 made biceps brachii to rest less without increasing the mean %EMG. Conclusion/Application: Findings of this study can be valuable information for phone designers to develop more productive device and for smartphone users to prevent the musculoskeletal disorders in the upper extremities.

Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity

  • Shah, Farhan Khalid;Gebreel, Ashraf;Elshokouki, Ali Hamed;Habib, Ahmed Ali;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.61-71
    • /
    • 2012
  • PURPOSE. To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS. Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS. Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION. Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis.