• 제목/요약/키워드: hysteresis loss

Search Result 213, Processing Time 0.029 seconds

Dynamic Modeling of an Fine Positioner Using Magnetic Levitation (자기 부상 방식 미세 운동 기구의 동적 모델링)

  • Jeong, Gwang-Seok;Baek, Yun-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.5 s.176
    • /
    • pp.1166-1174
    • /
    • 2000
  • In this paper, we introduce a positioner based on magnetic levitation to eliminate the friction which is the most severe effect to limit high resolution on the micro level. Differently from existing electromagnetic device, the proposed positioner consists of air core solenoid and permanent magnet. Although the combination produces small magnetic force, it is suitable for realizing micro motion repeatedly without the accumulation of error because there is no hysteresis caused by ferromagnetic materials, no eddy current loss, no flux saturation. First, the approximate modeling of stiffness and damping effects between the magnetic elements is made and verified experimentally. Then, we have formulated the dynamic equation of one d.o.f magnetic levitation positioner using linear perturbation method and discussed the necessity of optimization for the chief design parameters to maximize the stability performance.

Computational Study on Dynamic Characteristics of a Flapped Airfoil (전산해석을 이용한 고양력장치의 동특성 고찰)

  • Lee, Yung-Gyo;Kim, Cheol-Wan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.206-209
    • /
    • 2011
  • During landing approach, an airplane could experience dynamic unstable motion by the combination of a gust and elevator control to cancel the disturbances. This situation is dangerous and could lead to a loss of an airplane. In this paper, numerical analysis was used to study the effect of pitch oscillating 2-D high lift devices in a landing condition. Experimental data on a pitching naca0012 airfoil was used for code validation. Dynamic characteristics of an airfoil, single slotted flap for mid-class passenger aircraft were analyzed. Unsteady Navier-Stokes analysis was performed with Spalart-Allmaras turbulence model for separation dominant low speed flow. As a result, flow hysteresis of a flapped airfoil was more complex than that of an oscillating airfoil. So, dynamic analysis of a flap in a landing condition is very important for operational safety.

  • PDF

Prediction of Vibrational Responses of Automotive Door System Using Energy Flow Analysis in Medium-to-high Frequencies (에너지흐름해석법을 이용한 중고주파수 대역 자동차 도어 진동예측)

  • Park, Young-Ho;Hong, Suk-Yoon;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1097-1102
    • /
    • 2010
  • In this paper, the energy flow analysis(EFA) of the body-in-white door of a real automotive was performed using the energy flow finite element method(EFFEM) to effectively predict the vibrational responses of built-up structures in the medium to high frequency range. To increase the validity of EFA results, the structural hysteresis damping loss factor was measured by the experiment using the concept of statistical energy analysis(SEA). As the excitation frequency increases, the predicted results simulated with EFFEM generally agree with the experimental results.

The Effect of Ferrite Cores on the Inductively Coupled Plasma Driven at 13.56 MHz (13.56 MHz 유도 결합 플라즈마에서의 강자성체 페라이트 코어의 효과)

  • Lee, Won-Ki;Lee, Kyeong-Hyo;Chung, Chin-Wook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.3 s.12
    • /
    • pp.35-38
    • /
    • 2005
  • Due to high permeability of the ferrite cores, the characteristics of the inductively coupled plasma(ICP) are expected to be greatly improved. We investigated the effect of the ferrite cores on conventional inductively coupled plasma. It was observed that the current and voltage in the ICP antenna are slightly decreased and the power transfer efficiency is increased. However, due to eddy current and hysteresis loss, plasma density in the ICP with the ferrite cores is not increased. It seems that the ICP with the ferrite cores at low frequency ($\∼$100 kHz) will be greatly improved since the losses at the low frequency can be negligible.

  • PDF

The Effect of Surface Area of Silicas on Their Reinforcing Performance to Styrene-butadiene Rubber Compounds

  • Ryu, Changseok;Kim, Sun Jung;Kim, Do Il;Kaang, Shinyoung;Seo, Gon
    • Elastomers and Composites
    • /
    • v.51 no.2
    • /
    • pp.128-137
    • /
    • 2016
  • The effect of the surface area of silicas on their reinforcing performance to styrene-butadiene rubber (SBR) compounds was systematically investigated. The feasibility of the Brunauer-Emmett-Teller surface area ($S_{BET}$) as a parameter representing the characteristics of the silicas was discussed compared to the mesopore volume, c value, oil absorption, and uptake of silane. The increase in $S_{BET}$ of silicas caused a considerable increase in Mooney viscosity, minimum torque, and hysteresis loss of the silica-filled SBR compounds, while significantly enhancing their abrasion property. These changes were explained by the attrition between the hydrophilic silica surface and the hydrophobic rubber chains. As expected, the change in $S_{BET}$ did not induce any remarkable changes in the cure, processing, tensile, and dynamic properties of the silica-filled SBR compounds because the crosslinking density of the rubber chains mainly determined these properties.

Fabrication and Characterizations of Thick PZT Films for Micro Piezoelectric Devices (마이크로 압전 소자용 후막 PZT의 제조 및 물성 평가)

  • 박준식;박광범;윤대원;박효덕;강성군;최태훈;이낙규;나경환
    • Transactions of Materials Processing
    • /
    • v.11 no.7
    • /
    • pp.569-574
    • /
    • 2002
  • Recently, thick PZT films are required for the cases of micro piezoelectric devices with high driving force, high breakdown voltage and high sensitivity, and so on. In this work, thick PZT films were fabricated by Sol-Gel multi-coating method. Microstructures, and electrical properties of films were investigated by XRD, FESEM, impedance analyzer, and P-E hysteresis. PZT films with 2.7$mu extrm{m}$ to 4.4${\mu}{\textrm}{m}$ thickness were fabricated. Dielectric constant, loss, remnant polarization and coercive field of them were 880~1650 at 1kHz, 2~3% at 1kHz, 26~32 $\mu$C/$ extrm{cm}^2$, and 33~60kV/cm, respectively. Also a transverse piezoelectric coefficient $(e_{31,f})$ measurement system was fabricated and tested for thick film samples.

Effect of Particles Size on Magnetic Performance of Dielectromagnetics

  • Gaworska, Dominika;Hodgson, Simon N.B.;Koniarek, Jaroslaw;Weglinski, Bogumil
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.792-793
    • /
    • 2006
  • In the paper, the influence of different particle size $D:D>125{\mu}m$, $D<50{\mu}m$ and between on magnetic properties of a standardized dielectromagnetic is presented. The tests were taken at frequencies of between 50Hz, and 500Hz. Presented in the paper results provide important materials property data to allow the selection of the most appropriate dielectromagnetic particle size for different applications.

  • PDF

Magnetic Characterization of the Nd Based Permanent Magnet by Newly-Developed Bipolar Pulse-Type Hysteresis Loop Tracer

  • Rhee, J.R.
    • Journal of Magnetics
    • /
    • v.4 no.3
    • /
    • pp.73-75
    • /
    • 1999
  • By appliying an slternate pulsed magnetic field -generated by using a sequential ignition circuit and a magnet exciting circuit- with peak value of about 10 T to the rod type Nd based magnet Nd2Fe12.7Cr1.3B with length of 5 mm and diameter of 3.6 mm, the basic magnetic properties such as saturation magnetization, residual magnetization, coercivity, maximum energy products, magnetic anisotropy and anisotropic field are investigated with obtaining the major and minor J-H loops of the magnet. The increase in coercivity due to eddy currents in ac measurement of coercivity is calculated considering eddy current loss by analyzing a wave of generating magnetic field. The average coercivity calculated for the magnet is about 12.2 kOe, anisotropy magnetic field and anisotropic constant are measured as 60 kOe 2.43 Mj/$m^3$, respectively.

  • PDF

초정밀 선형 모터의 열.진동 분석

  • 임경화;이우영;설진수;김현철
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.05a
    • /
    • pp.163-168
    • /
    • 2004
  • Linear motor can directly apply to the system needed linear mot ions without rotary mot ions. To control a high-speed and high-resolution, the development of the linear motors is recently required in the high-integrated and speed process industry. This paper presents vibration analyses as well as measurement standards of the newly developed linear motors through analyzing the vibration characteristics and thermal behaviors of the advanced products. Vibration experiments are conducted for identifying the hysteresis and vibration level during operation. They are also included in the modal test to analyze the vibration. Analytic data using Finite Element Method (FEM) are compared with the results of the modal. Loss of temperature generated the linear motor leads to a serious deformation within its parts. The thermal behaviors are very important factor in linear motor. The FEM and experiments make it possible to understand these characteristics.

  • PDF

Magneto-Impedance Effect of CoFeSiBNi Amorphous Magnetic Films according to the size (CoFeSiBNi 아몰퍼스 합금의 소자 크기에 대한 자기-임피던스 효과 관찰)

  • Park, Byung-Kyu;Hwang, Sung-Woo;Moon, Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.339-341
    • /
    • 2007
  • Soft ferromagnetic materials are very useful for many sensors using magnetic materials with high permeability, low coercivity and low hysteresis loss. Among them, FeCoSiBNi amorphous magnetic films show us a good impedance change(about 3.05%/Oe, at 12MHz) by the exterior magnetic field in this experiment. These are produced by rapid solidification from the melt and the material is ejected in a jet from a nozzle and quenched in a stream of liquid. After that, we make them a shape of wire with different sizes of width. Thus, we can find that the impedance change (122.16%, at 12MHz) is occurred and the fabricated magnetic wire has the characteristics of good sensor element.

  • PDF