• 제목/요약/키워드: hygroscopic performance

검색결과 10건 처리시간 0.03초

Mechanical and Hygroscopic Behaviour of Teak Wood Sawdust Filled Recycled Polypropylene Composites

  • Yadav, Anil Kumar;Srivastava, Rajeev
    • Composites Research
    • /
    • 제31권5호
    • /
    • pp.202-208
    • /
    • 2018
  • In this paper, mechanical and hygroscopic properties of teak sawdust and recycled polypropylene (RPP) composites are evaluated and compared with virgin polypropylene (VPP) matrix based composites. Verities of composites are prepared by variation in the plastic types, wood plastic ratio and the addition of coupling agent in the formulations. Mixing of wood sawdust and polypropylene is done by a twin screw extruder, and then sheets of wood plastic composites (WPCs) are produced by using the compression molding method. The results show that recycled matrix composites exhibit better tensile, flexural strength with low impact strength than virgin matrix based composites. Recycled composites show low water absorption and thickness of swelling than virgin matrix based composites. The results confirm that wood content in the polymer matrix affects the performance of composites while presence maleated polypropylene (MAPP) improves the properties of the composites significantly. Developed RPP matrix composites are as useful as VPP matrix composites and have the potential to replace the wood and plastics products without any adverse effect of the plastics on the environment.

잣나무열처리재의 흡방습성능에 미치는 영향인자 분석 (Analysis of Factors Affecting the Hygroscopic Performance of Thermally Treated Pinus koraiensis Wood)

  • 장윤성;한연중;엄창득;박주생;박문재;최인규;여환명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권1호
    • /
    • pp.10-18
    • /
    • 2012
  • 최근 만들어지고 있는 거주공간은 단열성능 향상을 통한 냉난방 에너지 절약을 위하여 더욱 기밀해지고 있다. 이로 인해 일상생활 중에 발생하는 수분의 인위적인 배출과 외부공기의 인위적인 유입이 줄어듦에 따라 건축내장재의 자연조습기능에 대한 관심이 증대하고 있다. 본 연구에서는 열처리된 잣나무의 흡 방습성능을 평가하고 이에 영향을 미치는 인자들을 분석하였다. 상대습도 변화에 따른 평형함수율과 흡 방습률을 측정하였고, 조도(거칠기)와 미시적 표면형상, 그리고 FT-IR spectrum과 흡방습성과의 관계를 고찰하였다. 본 연구결과는 거주공간의 조습성능 정량화 평가시스템 구축을 위한 기초자료로 활용될 수 있을 것이라 기대된다.

게껍질로부터 CM-Chitin의 합성 (Synthesis of CM-Chitin from Crab Shells)

  • 안종일;김승환;유영진;박창호;임헌선;박찬구;박은경
    • 한국응용과학기술학회지
    • /
    • 제10권2호
    • /
    • pp.41-47
    • /
    • 1993
  • Chitin was isolated from crab shells by modified Hackman's method, which was treated again with aqueous sodium hydroxide solution to give alkali chitin(sodium alkoxide of chitin). And after, the alkali chitin is allowed to react with monochloroacetic acid to synthesize 6-O-(carboxymethyl) chitin [CM-Chitin] under diminished pressure. In order to synthesize high performance CM-Chitin as hygroscopic agent, it was measured that the yield and degree of subsititution of each CM-Chitin according to molar ratio(monochloroacetic acid equivalent mol/N-acetyl-D-glucosamine residue) and their moisture-absorption and moisture-release properties were measured and compared with those of hyaluronic acid. The moisture-absorption and moisture-release properties of CM-Chitin, especially 0.8 in degree of substitution, were found quite similar to those of hyaluronic acid. The preliminary results show that CM-Chitin might be used as hygroscopic agent instead of hyaluronic acid in field of cosmetics.

전도성 접착제를 이용한 패키징 기술 (Recent Advances in Conductive Adhesives for Electronic Packaging Technology)

  • 김종웅;이영철;노보인;윤정원;정승부
    • 마이크로전자및패키징학회지
    • /
    • 제16권2호
    • /
    • pp.1-9
    • /
    • 2009
  • Conductive adhesives have recently received a lot of focus and attention from the researchers in electronics industry as a potential substitute to lead-containing solders. Numerous studies have shown that the conductive adhesives have many advantages over conventional soldering such as environmental friendliness, finer pitch feasibility and lower temperature processing. This review focuses on the recent research trends on the reliability and property evaluation of anisotropic and non-conductive films that interconnect the integrated circuit component to the printed circuit board or other types of substrate. Major topics covered are the conduction mechanism in adhesive interconnects; mechanical reliability; thermo-mechanical-hygroscopic reliability and electrical performance of the adhesive joints. This review article is aimed at providing a better understanding of adhesive interconnects, their principles, performance and feasible applications.

  • PDF

지열 이용 외기부하 저감시스템의 냉각 및 가열효과 예측 간이추정법에 관한 연구 (A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy)

  • 손원득;최영식
    • 한국산업융합학회 논문집
    • /
    • 제13권3호
    • /
    • pp.169-181
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

  • PDF

젤라틴(아교)의 물성에 따른 단청 도막의 성능비교 연구 (A Study on the Film Performance by Physical Properties of Gelatin(Glue) in Dancheong)

  • 박지혜;정선혜;김익주;정용재
    • 보존과학회지
    • /
    • 제29권1호
    • /
    • pp.25-33
    • /
    • 2013
  • 전통 단청 교착제인 젤라틴(아교)의 물성에 따른 단청 도막의 성능을 평가하고자 직접 추출하거나 시판되는 아교 및 젤라틴 5종을 선정하고 수분반응성과 촉진내후성을 실험하였다. 실험결과, 겔 강도가 높은 1종의 젤라틴 단청 도막에서는 아교 대체 재료인 아크릴산 에스테르 수지 도막보다 수분 흡수율이 높고 촉진 내후성 시험 후에도 밀착성이 높았을 뿐만 아니라 젤라틴 도막보다 내수성이 우수하였다.

지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구 (A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy)

  • 손원득;박경순
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

Hygroscopic Properties of Light-Frame Wall with Different Assemblies

  • Kim, Se-Jong;Park, Chun-Young;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제34권2호
    • /
    • pp.22-29
    • /
    • 2006
  • On purpose to reduce accumulated moisture and to prevent moisture condensation in a light-frame wall, thermal characteristics and moisture behaviors were investigated for four different wall assemblies; a) typical wall, b) addition of vapor retarder between the insulation and the gypsum board, c) addition of air gap for natural ventilation behind the siding, d) composition with b) and c). Each wall was tested under two climate conditions; 1) $20^{\circ}C$, 50% RH (indoor) and $30^{\circ}C$, 85% RH (outdoor), 2) $30^{\circ}C$, 85% RH (indoor) and $20^{\circ}C$, 50% RH (outdoor).The results showed that the typical wall assembly had poor resistance against moisture intrusion from the inside of building. Outdoor and indoor humidity caused the moisture condensations on the inside of the siding and the back surface of the sheathing respectively. The addition of a vapor retarder did not give significant improvement in preventing the moisture intrusion.

신소재 복합재료를 이용한 우주용 카메라 구조의 고안정화 설계에 관한 연구 (Study on spaceborne telescope structure with high stability using new composite materials)

  • EUNG-SHIK LEE;SUN-HEE WOO
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.132-136
    • /
    • 2003
  • A Multi-Spectral Camera (MSC) is the payload of KOMPSAT-2 which is designed for earth imaging in visible and near-Infrared region on a sun-synchronous orbit. The telescope in the MSC is a Ritchey-Chretien type with large aperture. The telescope structure should be well stabilized and the optical alignment should be kept steady so that best images can be achieved. However, the MSC is exposed to adverse thermal environment on the orbit which can give impacts on optical performance. Metering structure which is exposed to adverse space environment should have tight requirement of low thermal expansion and hygroscopic stability. In order to meet those stability requirements in addition to fundamental structural ones telescope structure was designed with newly developed graphite-cyanate composite which has high tensile modulus, high thermal conductivity and low moisture absorption compared with conventional graphite-epoxy composite. In this paper, space-borne telescope structure with new composite material will be presented and fulfillment of stability requirements will be verified with designed structure.

  • PDF

저습도 사이클 조건에서의 라이너지와 골판지의 물성 (Physical Properties of Linerboard and Corrugated Fiberboard at the Cyclic Condition of Low Humidity)

  • 윤혜정;이학래;진성민;최익선
    • 펄프종이기술
    • /
    • 제39권2호
    • /
    • pp.38-44
    • /
    • 2007
  • The hygroscopic property of paper is important for convertability and end use performance. When the board and corrugated fiberboard are exposed to low relative humidity, a trouble of score (or crease) cracking could occur. In this study, we evaluated the moisture content and mechanical properties of linerboard and corrugated board at the cyclic condition of low humidity to prevent a score crack trouble. As the relative humidity decreased from 50% to 38% and 25%, the moisture content of linerboard decreased about 7% to 6% and 4%. At low humidity, most of mechanical properties were improved except for strain. The linerboard exposed at 25% RH showed a remarkable reduction of strain by 11%. At the same relative humidity, linerboard and corrugated fiberboard showed the different property values depending on moisture hysteresis.