• 제목/요약/키워드: hydroxyapatite (HA)

검색결과 243건 처리시간 0.026초

콜라겐 코팅된 결정화 하이드록시아파타이트 담체를 이용한 골아세포의 성장 (The Effect of Collagen Coating in Crystallized Hydroxyapatite Scaffold)

  • 김태곤;박원용;김용하;김연정;최식영
    • Archives of Plastic Surgery
    • /
    • 제36권3호
    • /
    • pp.247-253
    • /
    • 2009
  • Purpose: Hydroxyapatite(HA) has been widely used due to its chemical similarity to bone and good biocompatibility. HA is composed of macropores and micropores. Too much irregularities of the micropores are ineffective against the adhesion and proliferation of osteoblast. Many efforts have been tried to overcome these drawbacks. HA crystal coating on the irregular surface of HA scaffold, crystallized HA, is one of the method to improve cell adhesion. Meanwhile, the collagen has been incorporated with HA to create composite scaffold that chemically resembles the natural extracellular matrix components of bone. The authors proposed to examine the effect of collagen - coated crystallized HA on the adhesion and proliferation of osteoblast. Method: HA powder containing $10{\mu}m$ pore size was manufactured as 1 cm pellet size. For the making crystallized HA, 0.1 M EDTA solution was used to dissolve HA powder and heated $100^{\circ}C$ for 48 hours. Next, the crystallized HA pellets were coated with collagen (0.1, 0.5, and 1%). The osteoblasts were seeded into HA pellets and incubated for the various times (1, 5, and 9 days). After the indicating days, methylthiazol tetrazolium (MTT) assay was performed for cell proliferation and alkaline phosphatase (ALP) activty was measured for bone formation. Result: In SEM study, the surface of crystallized HA pellet was more regular than HA pellet. MTT assay showed that the proliferation of osteoblasts increased in a collagen dose - dependent and time - dependent manner and had a maximum effect at 1% collagen concentration. ALP activity also increased in a collagen dose - dependent manner and had a highest effect at 1% collagen concentration. Conclusion: These data showed that crystallization and collagen coating of HA was effective for osteoblast proliferation and ALP activity. Therefore, our results suggest that crystallized - HA scaffold with collagen coating is may be a good strategy for tissue engineering application for bone formation.

Second intercomparison on electron paramagnetic resonance (EPR) retrospective dosimetry in Korea using hydroxyapatite

  • HyoJin Kim;Jae Seok Kim;Byeong Ryong Park;Seongjae Jang;Han-Ki Jang;Ki-Taek Han;Hoon Choi;Jeongin Kim;In Jung Kim;Yunho Kim;Wi-Ho Ha;Jungil Lee;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4576-4582
    • /
    • 2023
  • The Korea retrospective dosimetry (KREDOS)-electron paramagnetic resonance (EPR) group undertook an intercomparison investigation utilizing hydroxyapatite. This analysis involved four institutions: the Korea Institute of Radiological and Medical Sciences, Dongnam Institute of Radiological and Medical Sciences, Korean Association for Radiation Application, and Radiation Health Institute of Korea Hydro & Nuclear Power. Following the irradiation of the hydroxyapatite sample, the recorded build-up was analyzed. To validate the reliability of the EPR dosimetry findings and enhance its operational performance, a hydroxyapatite dose-response curve was plotted and dosimetry was performed for a blind sample. The proficiency of each laboratory was assessed by employing an interlaboratory comparison methodology. This involved a comparative analysis of the measurement results by calculating the relative bias, z-score, and En value. The results submitted by the participating laboratories demonstrated satisfactory ratings for doses of 1.006, 3.999, and 6.993 Gy. Following the second intercomparison, efforts to optimize their hydroxyapatite-EPR dosimetry systems are underway in the participating laboratories. The current assessment of hydroxyapatite dose yielded the foundational data required to establish the parameters of dental dosimetry. In future, the third intercomparison experiment will be conducted for exploring other materials.

Anti-inflammatory effect of new calcium hydroxide paste containing silicon-substituted hydroxyapatite in lipopolysaccharide-stimulated macrophages

  • Roh, Ji-Yeon;Kim, Ki-Rim
    • 한국치위생학회지
    • /
    • 제18권4호
    • /
    • pp.423-432
    • /
    • 2018
  • Objectives: Calcium hydroxide, a root canal temporary sealer, has long been used and it has anti-bacterial and anti-inflammatory activity. To investigate the properties of a newly developed calcium hydroxide paste comprising silicon-substituted hydroxyapatite (Si-HA), we examined the anti-inflammatory activity of the new calcium hydroxide paste in RAW 264.7 macrophages stimulated by lipopolysaccharide (LPS), which causes infection of the root canal. Methods: The test materials, including Calcipex II as control group and the newly developed TRC paste, were extracted from cell culture media and then diluted for experiment. In LPS-stimulated RAW 264.7 cells, the cytotoxicity and nitric oxide (NO) production of test materials were measured by MTT assay and Griess reagents, respectively. Also, the expression of the inducible nitric oxide synthase (iNOS) was assessed by western blotting. Results: The IC50 values of Calcipex II and TRC paste were $17.6mg/m{\ell}$ and $13.5mg/m{\ell}$, respectively. The level of NO, increased by LPS, was dose-dependently inhibited more by TRC paste than Calcipex II treatment. In addition, iNOS expression was decreased by 71% and 92% at concentrations of $2mg/m{\ell}$ and $20mg/m{\ell}$ of TRC paste, respectively. Conclusions: We demonstrated that the Si-HA calcium hydroxide paste has a slightly improved anti-inflammatory property and further studies are needed before clinical recommendations are proposed.

Setting Behavior and Drug Release from Brushite Bone Cement prepared with Granulated Hydroxyapatite and β-Tricalcium Phosphate

  • Son, Yeong-Jun;Lee, In-Cheol;Jo, Hyun-Ho;Chung, Tai-Joo;Oh, Kyung-Sik
    • 한국세라믹학회지
    • /
    • 제56권1호
    • /
    • pp.56-64
    • /
    • 2019
  • Calcium phosphate bone cement was prepared to contain antibiotics for release after setting using granulated ${\beta}$-tricalcium phosphate (${\beta}$-TCP) and hydroxyapatite (HA). Gentamicin sulfate (GS) solution was infiltrated within the interconnected pores of the granule to avoid affecting the setting reaction and for protection of GS during the setting. Consequently, the setting time and the temperature increase were not affected, regardless of the loading of GS. The release of the GS from the cement was estimated by measuring the concentration at regular intervals from the cement dipped solution. The ${\beta}$-TCP granule loaded with GS exhibited the saturation of accumulative concentration at 16 h. In contrast, the HA granule with GS exhibited steady increase in accumulative concentration of over $10{\mu}g/ml$ at 144 h. Thus, the granulated cement could release the GS greater than the minimum inhibitory concentration of staphylococcus during the prescription peroid of the oral antibiotics.

레이저 소결 적층 시스템을 이용한 3차원 수산화인회석 인공지지체 제작에 관한 연구 (A Study on Fabrication of 3D Hydroxyapatite Scaffolds Using a Laser Sintering Deposition System)

  • 최승혁;사민우;김종영
    • 한국기계가공학회지
    • /
    • 제21권4호
    • /
    • pp.70-76
    • /
    • 2022
  • Calcium-phosphate-based bioceramics are promising biomaterials for scaffolds because they can assist in bone regeneration. In this study, a laser sintering deposition system was developed, and 3D hydroxyapatite (HA) scaffolds were fabricated. The main process conditions of the HA scaffolds were laser power, table velocity, and laser focal distance. As the laser power increased, the line width, line height, and layer thickness also increased. Further, the line width, line height, and layer thickness decreased as the table velocity increased. As the laser focal distance increased, the line width increased, but the line height and layer thickness decreased. The fabricated green scaffolds were sintered at 1050 ℃ and 1150 ℃. The sintered scaffolds had a uniform and continuous interconnected shape, with pore sizes ranging from 850 to 950 ㎛ having 53% porosity. The compressive strength of the scaffolds decreased from 0.72 MPa (1050 ℃) to 0.53 MPa (1150 ℃). The biocompatibility of the scaffolds was investigated by analyzing the adhesion of osteoblast-like MG-63 cells cultured on the surfaces of the scaffolds. The results indicate that the scaffold sintered at 1050 ℃ had good mechanical and biological properties compared to that at 1150 ℃.

Adhesion of Plasma Spray Coated Hydroxyapatite Film on the Two-Step Anodized Dental Implant

  • Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 춘계학술발표회 논문집
    • /
    • pp.126-126
    • /
    • 2012
  • In this study, adhesion of plasma spray coated hydroxyapatite film on the two-step anodized dental implant was investigated. The plasma spray was carried out on the dental implant after two step anodization. The adhesion of coated HA film was investigated by FE-SEM after fatigue test. In the case of two-step anodized implant showed a good adhesion between implant and coated film.

  • PDF

Medial Wall Orbital Reconstruction using Unsintered Hydroxyapatite Particles/Poly L-Lactide Composite Implants

  • Park, Hojin;Kim, Hyon-Surk;Lee, Byung-Il
    • 대한두개안면성형외과학회지
    • /
    • 제16권3호
    • /
    • pp.125-130
    • /
    • 2015
  • Background: Poly-L-lactide materials combined with hydroxyapatite (u-HA /PLLA) have been developed to overcome the drawbacks of absorbable materials, such as radiolucency and comparably less implant strength. This study was designed to evaluate the usefulness of u-HA/PLLA material in the repair of orbital medial wall defects. Methods: This study included 10 patients with pure medial wall blow-out fractures. The plain radiographs were taken preoperatively, immediately after, and 2 months after surgery. The computed tomography scans were performed preoperatively and 2 months after surgery. Patients were evaluated for ease of manipulation, implant immobility, rigidity and complications with radiologic studies. Results: None of the patients had postoperative complications, such as infection or enophthalmos. The u-HA/PLLA implants had adequate rigidity, durability, and stable position on follow-up radiographic studies. On average, implants were thawed 3.4 times and required 14 minutes of handling time. Conclusion: The u-HA/PLLA implants are safe and reliable for reconstruction of orbital medial wall in terms of rigidity, immobility, radiopacity, and cost-effectiveness. These thin yet rigid implants can be useful where wide periosteal dissection is difficult due to defect location or size. Since the u-HA/PLLA material is difficult to manipulate, these implants are not suitable for use in complex 3-dimensional defects.

Nano-Hydroxyapatite Modified by Grafting Polylactide and its Tissue Engineering Application

  • Zhuang, Xiuli;Zhang, Peibiao;Qiu, Xueyu;Chen, Xuesi;Jing, Xiabin
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.182-182
    • /
    • 2006
  • PLLA grafted Hydroxyapatite / polylactide (g-HA/PLA) composites were prepared by three grafting methods. The modified particles (p-HA) were dispersed more uniformly in the PLLA matrix than pure n-HA. The p-HA/PLLA composites exhibited better mechanical properties and thermal stability than the n-HA/PLLA composites. The composites also demonstrated improved cell compatibility due to the good biocompatibility of the HAP nanoparticles and the more uniform distribution of the PLLA-grafted HAP nanoparticles on the film surface. All of these results indicated that the p-HAP/PLLA nano-composites might have a promising medical application in bone repair and in bone tissue-engineering.

  • PDF

Comparative study on long-term stability in mandibular sagittal split ramus osteotomy: hydroxyapatite/poly-ʟ-lactide mesh versus titanium miniplate

  • Park, Young-Wook;Kang, Hyun-Sik;Lee, Jang-Ha
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.8.1-8.6
    • /
    • 2019
  • Background: Resorbable devices have recently been adopted in the field of orthognathic surgery with controversies about their postoperative skeletal stability. Hence, we determined the long-term skeletal stability of unsintered hydroxyapatite/poly-ʟ-lactic acid (HA/PLLA) mesh for osteofixation of mandibular sagittal split ramus osteotomy (SSRO), and compared it with that of titanium miniplate. Methods: Patients were divided into resorbable mesh and titanium miniplate fixation groups. A comparative study of the change in the mandibular position was performed with preoperative, 1-day, 6-month, and 2-year postoperative lateral cephalograms. Results: At postoperative 6 months-compared with postoperative 1 day, point B (supra-mentale) was significantly displaced anteriorly in the titanium-fixation group. Moreover, at postoperative 2 years-compared with postoperative 6 months, point B was significantly displaced inferiorly in the titanium-fixation. However, the HA/PLLA mesh-fixation group did not show any significant change with respect to point B postoperatively. Conclusions: The HA/PLLA mesh-fixation group demonstrated superior long-term skeletal stability with respect to the position of mandible, when compared with the titanium-fixation group.