• 제목/요약/키워드: hydrophilic support

검색결과 25건 처리시간 0.025초

Current Evidence for Spinal Opioid Selection in Postoperative Pain

  • Bujedo, Borja Mugabure
    • The Korean Journal of Pain
    • /
    • 제27권3호
    • /
    • pp.200-209
    • /
    • 2014
  • Background: Spinal opioid administration is an excellent option to separate the desirable analgesic effects of opioids from their expected dose-limiting side effects to improve postoperative analgesia. Therefore, physicians must better identify either specific opioids or adequate doses and routes of administration that result in a mainly spinal site of action rather than a cerebral analgesic one. Methods: The purpose of this topical review is to describe current available clinical evidence to determine what opioids reach high enough concentrations to produce spinally selective analgesia when given by epidural or intrathecal routes and also to make recommendations regarding their rational and safety use for the best management of postoperative pain. To this end, a search of Medline/Embase was conducted to identify all articles published up to December 2013 on this topic. Results: Recent advances in spinal opioid bioavailability, based on both animals and humans trials support the theory that spinal opioid bioavailability is inversely proportional to the drug lipid solubility, which is higher in hydrophilic opioids like morphine, diamorphine and hydromorphone than lipophilic ones like alfentanil, fentanyl and sufentanil. Conclusions: Results obtained from meta-analyses of RTCs is considered to be the 'highest' level and support their use. However, it's a fact that meta-analyses based on studies about treatment of postoperative pain should explore clinical surgery heterogeneity to improve patient's outcome. This observation forces physicians to use of a specific procedure surgical-based practical guideline. A vigilance protocol is also needed to achieve a good postoperative analgesia in terms of efficacy and security.

지지체 특성이 정삼투막 성능에 미치는 영향 (Effect of Support Membrane Property on Performance of Forward Osmosis Membrane)

  • 정보름;김종학;김범식;박유인;송두현;김인철
    • 멤브레인
    • /
    • 제20권3호
    • /
    • pp.235-240
    • /
    • 2010
  • 본 연구의 목적은 각기 다른 특성을 갖는 지지체에 따른 정삼투막의 성능을 비교 빛 평가하는 것이다. 계변 중합을 통하여 소수성 지지체인 폴리술폰(PSf)과 상대적으로 친수성 지지체인 폴리에테르술폰(PES)의 표변에 폴리아미드 활성층을 갖는 정삼투막을 제조하여 투과유량과 역확산을 비교하였다. PSf 정삼투막과 PES 정삼투막의 투과유량은 $4.36\;L/m^2hr$$17.8\;L/m^2hr$으로 PES를 지지체로 하는 정삼투막이 투과성능이 더 우수함을 알 수 있었으며, 이를 통해 지지체의 친수성과 정삼투 공정에서의 투과성능 간에 관련성이 존재함을 확인할 수 있었다. 또한 막의 두께가 앓아질수록 정삼투 공정에서 막의 투과유량은 증가하였다.

비닐-나노실리카볼 화합물의 클리어코트 특성 연구 (Synthesis of Vinyl-nano Silica Ball Composite : Its Application to Clearcoat)

  • 김봉겸;박건희;이용화;노승만;이재우;박승규
    • 공업화학
    • /
    • 제21권6호
    • /
    • pp.670-675
    • /
    • 2010
  • 나노실리카볼 입자를 합성하고 표면에 비닐기를 부여하는 합성 연구를 통해 다양한 크기로 조절이 된 유-무기하이브리드 입자인 비닐-나노실리카볼이 합성되었다. 다양한 크기의 비닐-나노실리카볼 입자를 상업적으로 적용되고 있는 아크릴-멜라민 클리어코트에 후첨시키고 경화시켰을 때, 클리어코트의 광택도 증가 및 유지 특성에 대해 연구하였다. 실리카볼 입자가 250 nm 정도인 경우 Matting effect에 의한 광택도 감소가 관측되었으나 20~30 nm로 작아지면 광택도 유지 효과가 약 7%까지 증가하였다. 나노실리카볼 대신 상업용 친수 실리카 Aerosil 200 (Hydrophilic fumed silica, 평균입도 12 nm, Degussa)을 사용하여 비닐- fumed 실리카 화합물을 합성하여 클리어코트에 적용하면 광택도 유지 효과가 약 2% 정도만 증가하였다.

해양관광 정책의 융복합적 접근에 관한 연구 (Convergence Approach of the Marine Tourism Policy)

  • 이정철
    • 디지털융복합연구
    • /
    • 제15권2호
    • /
    • pp.233-238
    • /
    • 2017
  • 최근 해양관광의 행태는 다양해지고 있지만 해안지역의 개발은 시설의 확충, 천연자원의 개발, 관광자원 개발 등 융복합적 산업의 개발이라는 어려움으로 정책 추진의 어려움을 겪고 있다. 본 연구는 관광객과 어촌어항이 함께 할 수 있는 융복합적인 측면에서 정책의 접근이 필요하다는 연구의 목적을 가지고 접근하였다. 본 연구에서는 해양관광산업과 관련된 정책을 조사하였으며, 해안지역과 어촌어항 지역 개발과 관련된 법령들을 조사하였다. 그리고 이를 바탕으로 융복합적 정책의 접근을 위한 문제점과 개발방안을 제시하였다. 해양관광 정책의 융복합적 접근 방안으로는 첫째, 해양관광자원 개발은 자연 보호 보전을 우선으로 하는 관광자원이 개발이 되어야 한다. 둘째, 지역 주민의 삶을 우선으로 하고 같이 참여할 수 있도록 법령의 개선과 지역 조례 등을 활용한 관리가 필요하다. 특히 '어촌 체험 마을' 등 현재 진행되고 있는 지원 사업 등을 통한 성공적인 모델을 발굴해야 한다.

셀룰로오스에 의한 지지체 친수화가 압력지연삼투막 성능에 미치는 영향 (Hydrophilizing Effect of Support on PRO Membrane Performance through Cellulose Solution Treatment)

  • 최명호;구기갑;임정애;김범식
    • 멤브레인
    • /
    • 제23권6호
    • /
    • pp.425-431
    • /
    • 2013
  • 본 연구의 목적은 지지체의 친수화가 압력지연삼투(Pressure retarded osmosis, PRO)막의 투과특성에 미치는 영향에 대해서 알아보고자 하였다. 소수성 지지체인 폴리에스테르를 친수성 고분자인 셀룰로오스 용액을 사용하여 친수화도를 조절하였다. 지지체의 친수화 특성만을 파악하기 위해서 지지층 없이 동일한 활성층을 사용하여 PRO 막 투과 특성을 비교하였다. 사용된 활성층은 1,4-dioxane과 cellulose tri-acetate (CTA, 13 wt%)를 사용하여 제조하였으며, $5kgf/cm^2$ 압력 하에서 행한 PRO 성능 평가의 경우 투과도가 친수화된 지지체를 사용한 경우와 친수화되지 않은 경우에 각각 $1.2L/m^2hr$$0.8L/m^2hr$로 친수화된 지지체를 사용할 경우 약 50% 투과량이 증가되는 특성을 보였다. 그러나 셀룰로오스 농도 변화에 따른 지지체의 친수화도 증가가 투과량 변화를 가져오지는 않았다. 이는 지지체를 친수화하기 위해 사용된 셀룰로오스의 농도가 증가함에 따라 지지체의 기공이 막히는 현상에 기인한 것으로 보인다. 이러한 결과를 통해 정삼투공정에서 투과유량을 높이기 위해서는 지지체로서 친수성 소재를 사용하여 분리막을 제조함과 동시에 지지체 기공을 유지하는 것이 중요함을 확인하였다.

Nano-scale Probe Fabrication Using Self-assembly Technique and Application to Detection of Escherichia coli O157:H7

  • Oh, Byung-Keun;Lee, Woochang;Lee, Won-Hong;Park, Jeong-Woo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권4호
    • /
    • pp.227-232
    • /
    • 2003
  • A self-assembled monolayer of protein G was fabricated to develop an immunosensor based on surface plasmon resonance (SPR), thereby improving the performance of the antibodybased biosensor through immobilizing the antibody molecules (lgG). As such, 11-mercaptoundecanoic acid (11-MUA) was adsorbed on a gold (Au) support, while the non-reactive hydrophilic surface was changed through substituting the carboxylic acid group (-COOH) in the 11-MUA molecule using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrocholide (EDAC). The formation of the self-assembled protein G layer on the Au substrate and binding of the antibody and antigen were investigated using SPR spectroscopy, while the surface topographies of the fabricated thin films were analyzed using atomic force microscopy (AFM). A fabricated monoclonal antibody (Mab) layer was applied for detecting E. coli O157:H7. As a result, a linear relationship was achieved between the pathogen concentration and the SPR angle shift, plus the detection limit was enhanced up to 10$^2$ CFU/mL.

Desalting enhancement for blend polyethersulfone/polyacrylonitrile membranes using nano-zeolite A

  • Mansor, Eman S.;Jamil, Tarek S.;Abdallah, Heba;Youssef, H.F.;Shaban, Ahmed M.;Souaya, Eglal R.
    • Membrane and Water Treatment
    • /
    • 제10권6호
    • /
    • pp.451-460
    • /
    • 2019
  • Thin film composite membranes incorporated with nano-sized hydrophilic zeolite -A were successfully prepared via interfacial polymerization (IP) on porous blend PES/PAN support for water desalination. The thin film nanocomposite membranes were characterized by SEM, contact angle and performance test with 7000 ppm NaCl solution at 7bar. The results showed that the optimum zeolite loading amount was determined to be 0.1wt% with permeate flux 29LMH.NaCl rejection was improved from 69% to 92% compared to the pristine polyamide membrane where the modified PA surface was more selective than that of the pristine PA. In addition, there was no significant change in the permeate flux of the thin film nanocomposite membrane compared with that of the pristine PA in spite of the formation of the dense polyamide layer. The stability of the polyamide layer was investigated for 15 days and the optimized membrane presented the highest durability and stability.

Cytotoxicity and biocompatibility of high mol% yttria containing zirconia

  • Gulsan Ara Sathi Kazi;Ryo Yamagiwa
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.52.1-52.11
    • /
    • 2020
  • Objectives: Yttria-stabilized tetragonal phase zirconia has been used as a dental restorative material for over a decade. While it is still the strongest and toughest ceramic, its translucency remains as a significant drawback. To overcome this, stabilizing the translucency zirconia to a significant cubic crystalline phase by increasing the yttria content to more than 8 mol% (8YTZP). However, the biocompatibility of a high amount of yttria is still an important topic that needs to be investigated. Materials and Methods: Commercially available 8YTZP plates were used. To enhance cell adhesion, proliferation, and differentiation, the surface of the 8YTZP is sequentially polished with a SiC-coated abrasive paper and surface coating with type I collagen. Fibroblast-like cells L929 used for cell adherence and cell proliferation analysis, and mouse bone marrow-derived mesenchymal stem cells (BMSC) used for cell differentiation analysis. Results: The results revealed that all samples, regardless of the surface treatment, are hydrophilic and showed a strong affinity for water. Even the cell culture results indicate that simple surface polishing and coating can affect cellular behavior by enhancing cell adhesion and proliferation. Both L929 cells and BMSC were nicely adhered to and proliferated in all conditions. Conclusions: The results demonstrate the biocompatibility of the cubic phase zirconia with 8 mol% yttria and suggest that yttria with a higher zirconia content are not toxic to the cells, support a strong adhesion of cells on their surfaces, and promote cell proliferation and differentiation. All these confirm its potential use in tissue engineering.

메조스케일 전산모사를 통한 술폰화 폴리이미드의 수화채널 형성 연구 (Investigation of Water Channel Formation in Sufonated Polyimides Via Mesoscale Simulation)

  • 박치훈;이소영;이창현
    • 멤브레인
    • /
    • 제27권5호
    • /
    • pp.389-398
    • /
    • 2017
  • 연료전지용 고분자 전해질막에 있어서 가장 중요한 특성인 수소이온 전달 능력은 내부에서 형성되는 수화채널의 분포 및 형상에 큰 영향을 받게 된다. 비과불화탄소계인 탄화수소계 전해질막의 경우, 과불화탄소계 전해질막인 나피온에 비하여 이러한 수화채널이 약하게 형성되는 것으로 알려져 있으며 따라서 상대적으로 낮은 이온전달 성능을 나타내는 것으로 보고되고 있다. 본 연구에서는 컴퓨터를 이용한 전산모사 기술의 하나인 메조스케일 전산모사 기술을 이용하여 탄화수소계 연료전지용 전해질막인 술폰화 폴리이미드의 가습조건에서의 수화채널 형성 및 상분리 현상을 관찰하였다. 이를 통하여 술폰화 폴리이미드 내부에서 물분자 비드는 친수성 영역 전체에 걸쳐서 고르게 분포되며 명확한 수화 클러스터는 높은 술폰화도에서만 형성되는 것이 관찰되었다. 또한, 술폰화 폴리이미드 모델은 저가습 상태에서 수화 채널을 형성하는데에 나피온 모델에 비하여 더 어렵다는 것이 관찰되었다. 이러한 결과들은 비과불화불소계인 탄화수소계 전해질막의 수화채널 형성에 대한 기존 이론을 명확하게 뒷받침하고 있으며, 술폰화 폴리이미드의 전도도 경향도 잘 설명을 하고 있다. 따라서 메조스케일 전산 모사 기술은 연료전지용 전해질막의 상분리 현상 및 수화채널을 분석하고 이온전도 특성을 규명하는 데에 있어서 매우 효과적인 기술이 될 수 있다는 것을 확인하였다.

염화비닐의 요중 대사물질인 thiodiglycolic acid의 분석을 위한 전처리 조건 (Pretreatment method of urinary thiodiglycolic acid as metabolite of vinyl chloride)

  • 홍주연;김치년;정재훈;장정환;노재훈
    • 한국산업보건학회지
    • /
    • 제9권1호
    • /
    • pp.23-40
    • /
    • 1999
  • The analysis of thiodiglycolic acid in urine has been used as an index of biological exposure to vinyl chloride. Unfortunately thiodiglycolic acid has a strong hydrophilic character, because it has two carboxylic groups, so that it can only be extracted with organic solvent with a great difficulty. Underivatized thiodiglycolic acid tends to tail because of non-specific interaction with the inert support. Therefore, esterification is the obvious first choice for derivatization of thiodiglycolic acid, particularly for gas chromatography. In this study, the focus of interest is to compare two method of esterifications (methylation and silylation). Methylation is to make the methyl ester of thiodiglycolic acid by reaction with diazomethane. Silylation is to make the trimethylsilyl ester of thiodiglycolic acid by reaction with N-trimethylsily-ldiethylamine. The results and conclusions are as the following: 1. The detection limit (sensitivity) of methylated thiodiglycolic acid was $5.00{\mu}g/m{\ell}$ and silylated thiodiglycolic acid was $3.07{\mu}g/m{\ell}$ by gas chromatography with flame ionization detector. 2. The optimal liquid-liquid extraction of thiodiglycolic acid was as following: To each of the tubes, $15m{\ell}$ of urine, concentrated sulfuric acid (pH 1 - 2) and 5 gsodium sulfate were added. The samples was extracted three times with $5m{\ell}$ ethylacetate each time. 3. The methylated thiodiglycolic acid was more stable than silylated thiodiglycolic acid in extractional solvent which contained humidity. 4. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.07324 in methylated thiodiglycolic acid with external standard calibration, and 0.07033 in methylated thiodiglycolic acid with internal standard calibration. 5. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.10914 in silylated thiodiglycolic acid with external standard calibration, and 0.13602 in silylated thiodiglycolic acid with internal standard calibration. From the above results, the analysis of methylated thiodiglycolic acid was more sensitive (limit of detection) than silylated thiodiglycolic acid by gas chromatography. However, the methylated thiodiglycolic acid was stable in the humidity and was separated sharply on chromatogram. Also, analysis of methylated thiodiglycolic acid was more precise (pooled coefficient of variation for 4 days) than silylated thiodiglycolic acid. In conclusion, it is established that the analysis of methylated thiodiglycolic acid is appropriate for biological monitoring of exposure to vinyl chloride.

  • PDF