• 제목/요약/키워드: hydraulic structures design

검색결과 218건 처리시간 0.022초

The conditional risk probability-based seawall height design method

  • Yang, Xing;Hu, Xiaodong;Li, Zhiqing
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권6호
    • /
    • pp.1007-1019
    • /
    • 2015
  • The determination of the required seawall height is usually based on the combination of wind speed (or wave height) and still water level according to a specified return period, e.g., 50-year return period wind speed and 50-year return period still water level. In reality, the two variables are be partially correlated. This may be lead to over-design (costs) of seawall structures. The above-mentioned return period for the design of a seawall depends on economy, society and natural environment in the region. This means a specified risk level of overtopping or damage of a seawall structure is usually allowed. The aim of this paper is to present a conditional risk probability-based seawall height design method which incorporates the correlation of the two variables. For purposes of demonstration, the wind speeds and water levels collected from Jiangsu of China are analyzed. The results show this method can improve seawall height design accuracy.

EXPERIMENTAL INVESTIGATION OF PRESSURE FLUCTUATIONS ON THE BED OF FLIP BUCKET SPILLWAYS

  • KAVIANPOUR M.R.;POURHASAN M.A.
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회(1)
    • /
    • pp.590-591
    • /
    • 2005
  • Hydrodynamic pressure fluctuations and their roles on the design of hydraulic structures has been the subject of many investigations. The studies showed that turbulent pressure fluctuations may cause serious damages to hydraulic structures. In case of high velocity flows, separation of flow from the boundary also causes the local pressure to drop and as a result, the resultant pressure fluctuations may trigger cavitation. Sever hydrodynamic pressures are also associated with the vibration of structures. Therefore, in this work, experiments were performed to determine the intensity of pressure fluctuations and their distribution along the bed of a ski-jump flip bucket. Experiments were completed on a physical model at the Institution of Water Research of Iran. The results consist of the statistical characteristics of pressure fluctuations, its maximum, minimum, and r.m.s values along the bed of the bucket. The spectral analysis of pressure fluctuations which is useful for the instability analysis of such structures is also provided. It is hoped that the present results will help the designer of such structures.

  • PDF

Seismic probabilistic risk assessment of weir structures considering the earthquake hazard in the Korean Peninsula

  • Alam, Jahangir;Kim, Dookie;Choi, Byounghan
    • Earthquakes and Structures
    • /
    • 제13권4호
    • /
    • pp.421-427
    • /
    • 2017
  • Seismic safety evaluation of weir structure is significant considering the catastrophic economical consequence of operational disruption. In recent years, the seismic probabilistic risk assessment (SPRA) has been issued as a key area of research for the hydraulic system to mitigate and manage the risk. The aim of this paper is to assess the seismic probabilistic risk of weir structures employing the seismic hazard and the structural fragility in Korea. At the first stage, probabilistic seismic hazard analysis (PSHA) approach is performed to extract the hazard curve at the weir site using the seismic and geological data. Thereafter, the seismic fragility that defines the probability of structural collapse is evaluated by using the incremental dynamic analysis (IDA) method in accordance with the four different design limit states as failure identification criteria. Consequently, by combining the seismic hazard and fragility results, the seismic risk curves are developed that contain helpful information for risk management of hydraulic structures. The tensile stress of the mass concrete is found to be more vulnerable than other design criteria. The hazard deaggregation illustrates that moderate size and far source earthquakes are the most likely scenario for the site. In addition, the annual loss curves for two different hazard source models corresponding to design limit states are extracted.

월파조건에서 경사제 항내측 사면에 거치된 테트라포드의 안정성 실험 (Experiments on Stability of Tetrapods on Rear Slope of Rubble Mound Structures under Wave Overtopping Condition)

  • 김영택;이종인
    • 한국해안·해양공학회논문집
    • /
    • 제33권6호
    • /
    • pp.357-366
    • /
    • 2021
  • 본 연구에서는 항내측 피복재의 안정성에 대한 단면수리실험을 수행하였다. 국내 항만 및 어항설계기준에서는 항내측 피복재의 중량산정 방법으로 상치콘크리트가 설치되지 않은 조건에 대하여 항내측 일부구간(최저설계 정수면에서 0.5 H 깊이까지)을 항외측 피복재와 동일 중량비의 피복재를 사용하도록 설계 도표로 제시하고 있다. 국내에 설계되는 대부분의 경사식 구조물은 상치콘크리트가 설치되어 있으며, 이에 대한 안정중량 산정 방법이 필요하다. van der Meer(1999)가 제시한 안정계수(Nod = 0.5)를 기준으로 피복재(테트라포드)의 안정성을 검토하였으며, 항외측 피복재의 0.8배에 해당하는 중량의 피복재를 항내측에 거치할 경우 안정성을 확보할 수 있는 것으로 나타났다.

DEVELOPMENT OF A FLOOD PROTECTION SYSTEM BY THE USE OF MODEL TESTS

  • Knoblauch Helmut;Goekler Gottfried;Heigerth Guenther
    • Water Engineering Research
    • /
    • 제3권1호
    • /
    • pp.45-55
    • /
    • 2002
  • The Szentgotthard Flood Protection Project is located in the southeasters part of Austria, very close to the Hungarian border and to the Hungarian town of Szentgotthard situated near the Junction of the rivers Lafnitz and Raab. During heavy rainstorms, this area has always been liable to severe floodings, affecting the town itself and upstream reaches, where major industrial and commercial development is planned. In order to solve these problems, several solutions have been developed by means of a series of model tests performed at the hydraulic laboratory of the Technical University of Graz, Austria. The model was constructed to scales 1:75 (lengths) and 1:25 (heights). This trebled scale allowed greater accuracy in the measurement of discharge depths. The results from the model tests have led to the following proposals: - Construction of a flood relief trough with an inflow section 3.5 km upstream of the junction of the rivers Lafnitz and Raab. - Use of a former river bed for the flood relief trough. - Design of a lowered embankment crest section to pass one-third of the maximum flood flow of the river Lafnitz. - Connection of the flood relief trough to the Lahnbach stream, a tributary of the river Raab.

  • PDF

제방의 손상 유형 및 보수보강 (Damage Types of Levee and its Maintenance and Repair)

  • 문대호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.144-169
    • /
    • 2010
  • In 2002, property loss caused by failure or leakage of existing river levee structures was about 1.8 trillion in Korean Won, and furthermore in which damages of river structures are getting more severe due to characteristics of extremely extraordinary rain such as torrential rain in the locality or guerrilla heavy rain. In this regards, this paper collects and analyzes those damage records and costs for repair by statistic method, and moreover categorizes the causes of failure, erosion and overtopping of levee structures in large and small scale rivers threatened frequently by typhoon and heavy rainfall. It is believed that the results from the analyses can be used as a basic source in developing criteria of standards for design, construction, maintenance and inspection(or diagnosis) of hydraulic structures such as levee and drain conduit.

  • PDF

Computer aided reinforcement design of RC structures

  • An, Xuehui;Maekawa, Koichi
    • Computers and Concrete
    • /
    • 제1권1호
    • /
    • pp.15-30
    • /
    • 2004
  • In this study, a design process for reinforced concrete structures using the nonlinear FEM analysis is developed. Instead of using the nonlinear analysis to evaluate the required performance after design process, the nonlinear analysis is applied before designing the reinforcement arrangement inside the RC structures. An automatic reinforcement generator for computer aided reinforcement agreement is developed for this purpose. Based on a nonlinear FEM program for analyzing the reinforced concrete structure, a smart fictitious material model of steel, is proposed which can self-adjust the reinforcement to the required amount at the cracking location according to the load increment. Using this tool, the reinforcement ratio required at design load level can be decided automatically. In this paper, an example of RC beam with opening is used to verify the proposed process. Finally, a trial design process for a real size underground RC LNG tank is introduced.

Application of Hybrid Structural System Using Coupled Vibration Control Structure and Seismic Isolated Structure in High-Rise Building

  • Nakajima, Shunsuke
    • 국제초고층학회논문집
    • /
    • 제10권3호
    • /
    • pp.219-227
    • /
    • 2021
  • This building is a forty-eight story, 170 meters high multiple dwelling house with Dual Frame System (DFS), a coupled vibration system connecting two independent structures with hydraulic dampers. Generation of large deformation between two structures during earthquakes contributes to make the hydraulic dampers effective. To improve the aseismic performance more, this building adopts DFS hybrid system that consists of DFS and base isolation system. About typical floors, columns and beams are constructed with LRV precast concrete method that shorten the construction period greatly by integrating column-beam joints in column members.

방조제 축조 예정지반의 지진에 의한 액상화 거동 평가 (A Study on the Evaluation of Dynamic Behavior and Liquefaction Cau8ed by Earthquake of Sea Dike Structures on the Ground)

  • 도덕현;장병욱;고재만
    • 한국농공학회지
    • /
    • 제35권2호
    • /
    • pp.43-56
    • /
    • 1993
  • The laboratory tests are performed on how the liquefaction potential of the sea dike structures on the saturated sand or silty sand seabed could be affected due to earthquake before and after construction results are given as follows ; 1. Earthquake damages to sea dike structures consist of lateral deformation, settlement, minor abnormality of the structures and differential settlement of embankments, etc. It is known that severe disasters due to this type of damages are not much documented. Because of its high relative cost of the preventive measures against this type of damages, the designing engineer has much freedom for the play of judgement and ingenuity in the selection of the construction methods, that is, by comparing the cost of the preventive design cost at a design stage to reconstruction cost after minor failure. 2. The factors controlling the liquefaction potential of the hydraulic fill structure are magnitude of earthquake(max. surface velocity), N-value(relative density), gradation, consistency(plastic limit), classification of soil(G & vs), ground water level, compaction method, volumetric shear stress and strain, effective confining stress, and primary consolidation. 3. The probability of liquefaction can be evaluated by the simple method based on SPT and CPT test results or the precise method based on laboratory test results. For sandy or silty sand seabed of the concerned area of this study, it is said that evaluation of liquefaction potential can be done by the one-dimensional analysis using some geotechnical parameters of soil such as Ip, Υt' gradation, N-value, OCR and classification of soils. 4. Based on above mentioned analysis, safety factor of liquefaction potential on the sea bed at the given site is Fs =0.84 when M = 5.23 or amax= 0.12g. With sea dike structures H = 42.5m and 35.5m on the same site Fs= 3.M~2.08 and Fs = 1.74~1.31 are obtained, respectively. local liquefaction can be expected at the toe of the sea dike constructed with hydraulic fill because of lack of constrained effective stress of the area.

  • PDF