• 제목/요약/키워드: hydraulic influence

검색결과 450건 처리시간 0.029초

Influence of spatial variability on unsaturated hydraulic properties

  • Tan, Xiaohui;Fei, Suozhu;Shen, Mengfen;Hou, Xiaoliang;Ma, Haichun
    • Geomechanics and Engineering
    • /
    • 제23권5호
    • /
    • pp.419-429
    • /
    • 2020
  • To investigate the effect of spatial variability on hydraulic properties of unsaturated soils, a numerical model is set up which can simulate seepage process in an unsaturated heterogeneous soil. The unsaturated heterogeneous soil is composed of matrix sand embedded with a small proportion of clay for simulating the heterogeneity. Soil-water characteristic curve and unsaturated hydraulic conductivity curve of the unsaturated soil are expressed by Van Genuchten model. Hydraulic parameters of the matrix sand are considered as random fields. Different autocorrelation lengths (ACLs) of hydraulic parameter of the matrix sand and different proportions of clay are assumed to investigate the influence of spatial variability on the equivalent hydraulic properties of the heterogeneous soil. Four model sizes are used in the numerical experiments to investigate the influence of scale effects and to determine the sizes of representative volume element (RVE) in the numerical simulations. Through a number of Monte Carlo simulations of unsaturated seepage analysis, the means and the coefficients of variations (COVs) of the equivalent hydraulic parameters of the heterogeneous soil are calculated. Simulations show that the ACL and model size has little influence on the means of the equivalent hydraulic parameters, but they have a large influence on the COVs of the equivalent hydraulic parameters. The size of an RVE is mainly affected by the ACL and the proportion of heterogeneity. The influence of spatial variability on the hydraulic parameters of the heterogeneous unsaturated soil can be used as a guidance for geotechnical reliability analysis and design related to unsaturated soils.

수목 식재에 따른 하천내 수리학적 영향 평가 (Assesment of Hydraulic Influence by Tree Planting in River)

  • 권택훈;최승용;한건연
    • 환경영향평가
    • /
    • 제19권5호
    • /
    • pp.511-525
    • /
    • 2010
  • Understanding of the hydraulics of flow over vegetation is very important to support the management of fluvial processes. The objective of this study is to assess the effects of hydraulic influence by tree planting in a compound channel with vegetated floodplain. This study analyzes the influence of tree planting on hydraulic features in Young-river in Munkyung city using HEC-RAS and RMA-2 model. The study results showed that there is a rise in water surface elevation and decrease in velocity near vegetated area. It is also ascertained that only negligible effects was seen within the feasible range of freeboard for the existing levees. However, as hydraulic features can vary depending on the aspect of flood inundation during each flood period, it is necessary to accumulate data through continuous data collecting.

물의 염도가 압축벤토나이트의 수리전도도에 미치는 영향 (Influence of Water Salinity on the Hydraulic Conductivity of Compacted Bentonite)

  • 조원진;김진섭;최종원
    • 방사성폐기물학회지
    • /
    • 제9권4호
    • /
    • pp.199-206
    • /
    • 2011
  • 다양한 건조밀도를 가진 압축벤토나이트의 수리전도도에 물의 염도가 미치는 영향이 조사되었다. 압축벤토나이트의 수리전도도는 벤토나이트의 건조밀도가 상대적으로 낮은 경우에만, 염도가 증가함에 따라 증가하였으며, 염도의 증가에 따른 수리전도도의 증가 정도는 벤토나이트의 건조밀도가 낮을수록 더 현저하였다. 건조밀도가 1.0 $Mg/m^3$ 및 1.2 $Mg/m^3$ 인 압축벤토나이트의 경우, 0.4 M NaCl 용액의 수리전도도는 탈염수의 경우에 비해 각각 7배 및 3배가 증가하였다. 그러나 1.4 $Mg/m^3$ 보다 큰 건조밀도를 가진 압축벤토나이트의 경우에는, 수리전도도에 미치는 염도의 영향이 크지 않았으며, NaCl의 농도가 0.04 M에서 0.4 M 인 범위에서는 거의 일정한 값을 유지하였다. 벤토나이트 시편을 탈염수로 미리 포화시키는 것은 수리전도도에 큰 영향을 미치지 않았다.

Piping현상 발생에 미치는 투수계수비와 침투유속의 영향에 대한 연구 (The Influence of K-ratio and Seepage Velocity on Piping Occurrence)

  • 허경한;장옥성
    • 한국방재학회 논문집
    • /
    • 제8권2호
    • /
    • pp.129-138
    • /
    • 2008
  • 차수성이 요구되는 제체나 댐체에 대하여 안정성을 판단하고자 할 경우 파이핑 현상발생 여부를 검토한다. 제체나 댐체는 층 다짐을 수행하면서 축조되므로 투수성은 수평방향 투수계수($k_x$)와 연직방향 투수계수($k_y$)가 서로 다른 이방성이 될 수 있다. 본 연구에서는 여러 가지 투수계수 비(k-ratio=$k_y/k_x$k)에 따른 침투해석을 수행하여 유출동수경사와 침투유속을 파악하고, 이론식에 의한 한계동수경사와 경험식에 의한 한계유속과 각각 비교.검토하여 파이핑에 미치는 영향을 검토하였다. 연구결과 투수계수 비는 한계동수경사 개념으로 파이핑 현상발생에 대한 안정성을 검토할 경우 매우 중요한 요소로 작용하나, 한계유속 개념에 대해서는 상대적으로 중요도가 매우 낮은 것으로 확인되었다.

Influence of the Francis Turbine location under vortex rope excitation on the Hydraulic System Stability

  • Alligne, S.;Nicolet, C.;Allenbach, P.;Kawkabani, B.;Simond, J.J.;Avellan, F.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.286-294
    • /
    • 2009
  • Hydroelectric power plants are known for their ability to cover variations of the consumption in electrical power networks. In order to follow this changing demand, hydraulic machines are subject to off-design operation. In that case, the swirling flow leaving the runner of a Francis turbine may act under given conditions as an excitation source for the whole hydraulic system. In high load operating conditions, vortex rope behaves as an internal energy source which leads to the self excitation of the system. The aim of this paper is to identify the influence of the full load excitation source location with respect to the eigenmodes shapes on the system stability. For this, a new eigenanalysis tool, based on eigenvalues and eigenvectors computation of the nonlinear set of differential equations in SIMSEN, has been developed. First the modal analysis method and linearization of the set of the nonlinear differential equations are fully described. Then, nonlinear hydro-acoustic models of hydraulic components based on electrical equivalent schemes are presented and linearized. Finally, a hydro-acoustic SIMSEN model of a simple hydraulic power plant, is used to apply the modal analysis and to show the influence of the turbine location on system stability. Through this case study, it brings out that modeling of the pipe viscoelastic damping is decisive to find out stability limits and unstable eigenfrequencies.

마이크로 용적형 수차의 측면누설손실이 성능에 미치는 영향 (Influence of Side Leakage Loss on the Performance of a Micro Positive Displacement Hydraulic Turbine)

  • 최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.291-295
    • /
    • 2006
  • Recently, greenhouse effect by $CO_2$ gas emitted by use of fossil fuel causes earth environmental problem. As a countermeasure of the global warming. micro hydropower under 100kW becomes the focus of attention for its clean and renewable energy sources. Newly developed micro positive displacement hydraulic turbine shows high efficiency and good applicability for the micro hydropoewer. The purpose of this study is to clarify the influence of leakage loss and effective head on the performance of the positive displacement hydraulic turbine for the further improvement of the turbine performance. The results show that the turbine. with a smaller side clearance. has much higher efficiency than that with bigger side clearance and it can sustain the high efficiency under the wider range of operation conditions. The turbine torque is proportional to the effective head and independent of the flow rate. The leakage is also dependent on the effective head but nearly independent of the flow rate.

국내 시설농업단지의 수리지질 특성을 고려한 인공함양 민감도 분석 : 수리전도도 및 주입정과 양수정의 이격거리 (Sensitivity Analysis of Artificial Recharge in Consideration of Hydrogeologic Characteristics of Facility Agricultural Complex in Korea : Hydraulic Conductivity and Separation Distance from Injection Well to Pumping Well)

  • 최정찬;강동환
    • 한국환경과학회지
    • /
    • 제28권9호
    • /
    • pp.737-749
    • /
    • 2019
  • In this study, the sensitivity analysis of hydraulic conductivity and separation distance (distance between injection well and pumping well) was analyzed by establishing a conceptual model considering the hydrogeologic characteristics of facility agricultural complex in Korea. In the conceptual model, natural characteristics (topography and geology, precipitation, hydraulic conductivity, etc.) and artificial characteristics (separation distance from injection well to pumping well, injection rate and pumping rate, etc.) is entered, and sensitivity analysis was performed 12 scenarios using a combination of hydraulic conductivity ($10^{-1}cm/sec$, $10^{-2}cm/sec$, $10^{-3}cm/sec$, $10^{-4}cm/sec$) and separation distance (10 m, 50 m, 100 m). Groundwater drawdown at the monitoring well was increased as the hydraulic conductivity decreased and the separation distance increased. From the regression analysis of groundwater drawdown as a hydraulic conductivity at the same separation distance, it was found that the groundwater level fluctuation of artificial recharge aquifer was dominantly influenced by hydraulic conductivity. In the condition that the hydraulic conductivity of artificial recharge aquifer was $10^{-2}cm/sec$ or more, the radius of influence of groundwater level was within 20 m, but In the condition that the hydraulic conductivity is $10^{-3}cm/sec$ or less, it is confirmed that the radius of influence of groundwater increases sharply as the separation distance increases.