• Title/Summary/Keyword: hydraulic head

검색결과 378건 처리시간 0.025초

SMART 연구로 주냉각재펌프의 검증시험 (Qualification Test of a Main Coolant Pump for SMART Pilot)

  • 박상진;윤의수;오형우
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.858-865
    • /
    • 2006
  • SMART Pilot is a multipurpose small capacity integral type reactor. Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of $310^{\circ}C$ and 14.7MPa. Thus MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In present wort a test apparatus to simulate real operating situations of the reactor has been designed and constructed to test MCP. And then functional tests, performance tests, and endurance tests have been carried out upon a prototype MCP. Canned motor characteristics, homologous head/torque curves, coast-down curves, NPSH curves and lift-time performance variations were obtained from the qualification test as well as hydraulic performance characteristics of MCP.

자연 구릉지에서 지표하 흐름의 수치해석 (Numerical Analysis of Subsurface Flow in a Hillslope)

  • 최은호;남선우
    • 물과 미래
    • /
    • 제24권1호
    • /
    • pp.109-117
    • /
    • 1991
  • 포화-비포화 영역에서 transient흐름 해석을 위해 유체의 연속방정식과 Darcy 법칙으로부터 다공질 매체에서의 흐름 지배방정식을 유도하였다. 수치해는 가중잔차원리에 입각한 Galerkin 유한요소법으로 구하며, 시간도함수항에는 유한차분법을 적용하였다. 해석에서는 실제 자연상태에서 발생되는 부정호우자료를 이용하고 이때의 지표하 흐름 해석에 필요한 강우 주상도는 제 손실성분을 고려한 초과우량 추정모형으로부터 얻었다. 비포화 토양에서의 흐름을 고려하기 위해 투수계수, 압력수두 및 체적함수비의 상호 함수관계를 이용하였다. 모형은 대칭인 2차원으로서 비등방성, 이질 토층으로 구성하였다.

  • PDF

수소생산용 원자로에서 동심축 이중관형 1차 고온가스덕트의 예비 구조정산 (Preliminary Structural Sizing of the Co-axial Double-tube Type Primary Hot Gas Duct for the Nuclear Hydrogen Reactor)

  • 송기남;김용완
    • 한국압력기기공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.1-6
    • /
    • 2008
  • Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source for nuclear hydrogen generation. The VHTR can produce hydrogen from heat and water by using a thermo-chemical process or from heat, water, and natural gas by steam reformer technology. A co-axial double-tube primary hot gas duct (HGD) is a key component connecting the reactor pressure vessel and the intermediate heat exchanger (IHX) for the VHTR. In this study, a preliminary design analysis for the primary HGD of the nuclear hydrogen system was carried out. These preliminary design activities include a determination of the size, a strength evaluation and an appropriate material selection. The determination of the size was undertaken based on various engineering concepts, such as a constant flow velocity model, a constant flow rate model, a constant hydraulic head model, and finally a heat balanced model.

  • PDF

청송 양수발전소 시공사례 (A Case Study on the Chungsong Pumped-storage power station Construction)

  • 홍창수;이현구;도종열
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.169-178
    • /
    • 2006
  • The pumped-storage power system is the one of the hydroelectric power systems, generating electricity with hydraulic head difference. In this system, the electricity is produced during the hours of peak demand by using water that has been pumped into an upper reservoir from a lower reservoir during the hours of low demand. Generally, the system consists of an under-ground power house and tunnels such as the headrace, pressure, and tailrace tunnels. The Chungsong pumped-storage power station is the sixth one In the pumped-storage power station in Korea. Both the regional self-government and the population of chungsong -Goon had made a great effort to draw this power station construction into this area. The proposed Chungsong pumped-power station construction project was accepted by the central government as a part of the national electricity plan for the first time in Korea.

  • PDF

끝틈새가 터보펌프 인듀서의 성능에 미치는 영향 (Effect of Tip Clearance on the Performance of a Turbopump Inducer)

  • 홍순삼;김진선;최창호;김진한
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.558-563
    • /
    • 2004
  • Experiments were performed to see the effect of radial tip clearance on a turbopump inducer, which has two blades with inlet tip blade angle of 7.8 degree and tip solidity of 2.7. Hydraulic and cavitation tests were done for three cases of tip clearance ratio, that is, 0.026, 0.053, and 0.079. With increase in the tip clearance, inducer head and pressure on the inducer tip decreased. Attached cavitation and cavitation surge were found in the cavitation tests. In the attached cavitation one cell rotated at the same rotational speed as that of the inducer. Cavitation performance deteriorated with increase in the tip clearance. The level of casing vibration increased in the cavitation condition and the level was very high when the attached cavitation appeared.

  • PDF

Correction and Experimental Verification of Velocity Circulation in a Double-blade Pump Impeller Outlet

  • Kai, Wang;Qiong, Liu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권4호
    • /
    • pp.311-317
    • /
    • 2015
  • It is difficulty to calculate velocity circulation in centrifugal pump impeller outlet accurately. Velocity circulations of a double-blade pump impeller outlet were calculated with Stodola formula, Weisner formula and Stechkin formula. Simultaneously, the internal flow of impeller for the double-blade pump were measured with PIV technology and average velocity circulations at the 0.8, 1.0 and 1.2 times of design flow were obtained. All the experimental values were compared with the above calculation values at the three conditions. The results show that calculation values of velocity circulations with Weisner formula is close to the experimental values. On the basis of the above, velocity circulations of impeller outlet were corrected. The results of experimental verification show that the corrected calculation errors, whose maximum error is 3.65%, are greatly reduced than the uncorrected calculation errors. The research results could provide good references for establishment of theoretical head and multi-condition hydraulic optimization of double-blade pumps.

끝틈새가 터보펌프 인듀서의 성능에 미치는 영향 (Effect of Tip Clearance on the Performance of a Turbopump Inducer)

  • 홍순삼;김진선;최창호;김진한
    • 한국유체기계학회 논문집
    • /
    • 제9권1호
    • /
    • pp.19-24
    • /
    • 2006
  • Experiments are carried out to investigate the effect of radial tip clearance on a turbopump inducer, which has two blades with inlet tip blade angle of 7.8 degree and tip solidity of 2.7. Hydraulic and cavitation tests are performed for three cases of tip clearance ratio, that is, 0.026, 0.053, and 0.079. With increase in the tip clearance, inducer head and pressure on the inducer tip decrease. Attached cavitation and cavitation surge are observed in the cavitation tests. In the attached cavitation one cell rotates at the same rotational speed as that of the inducer. Cavitation performance deteriorates with increase in the tip clearance. The level of casing vibration increases in the cavitation condition and the level is very high when the attached cavitation appears.

양배수용 사류펌프 내 삼차원 유동에 대한 수치적 연구 (Numerical Study on Three-Dimensional Flow in a Mixed-Flow Pump for Irrigation and Drainage)

  • 김진혁;안형진;김광용
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.17-22
    • /
    • 2010
  • In this paper, numerical study on a mixed-flow pump for irrigation and drainage has been performed based on three-dimensional viscous flow analysis. Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model are discretized by finite volume approximations and solved by the commercial CFD code ANSYS CFX-11.0. A structured grid system is constructed in the computational domain, which has O-type grids near the blade surfaces and H/J-type grids in other regions. The numerical results were validated with experimental data for the heads and efficiencies at different flow coefficients. The efficiency at the design flow coefficient is evaluated with the variation of two geometric variables related to area of discharge and length of the vane in the diffuser. The results show that efficiency of the mixed-flow pump at the design flow coefficient is improved by the modifications of the geometry.

Optimal Design of Two-Dimensional Cascade with Shock-Free Inflow Criterion

  • Muis, Abdul;Sutikno, Priyono;Soewono, Aryadi;Hartono, Firman
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권4호
    • /
    • pp.362-369
    • /
    • 2016
  • The shock-free inflow criterion applied in the development of two-dimensional cascade for turbomachinery design. The developed cascade analysis with potential flow calculation through a panel method has been used to determine the shock-free inflow condition. The combination between cascade analysis and PSO (particle swarm optimization) algorithm provides an opportunity to develop a diagram of a two-dimensional parameter cascade at various airfoil shapes. Analytical equations have been derived from the diagram that will facilitate the turbomachinery designer in applying the shock-free inflow criterion on their developed cascade. This method has been used to develop the very low head axial hydraulic turbine and provides excellent results of numerical and actual prototype performances.

Improving the Genetic Algorithm for Maximizing Groundwater Development During Seasonal Drought

  • Chang, Sun Woo;Kim, Jitae;Chung, Il-Moon;Lee, Jeong Eun
    • 지질공학
    • /
    • 제30권4호
    • /
    • pp.435-446
    • /
    • 2020
  • The use of groundwater in Korea has increased in recent years to the point where its extraction is restricted in times of drought. This work models the groundwater pumping field as a confined aquifer in a simplified simulation of groundwater flow. It proposes a genetic algorithm to maximize groundwater development using a conceptual model of a steady-state confined aquifer. Solving the groundwater flow equation numerically calculates the hydraulic head along the domain of the problem; the algorithm subsequently offers optimized pumping strategies. The algorithm proposed here is designed to improve a prior initial groundwater management model. The best solution is obtained after 200 iterations. The results compare the computing time for five simulation cases. This study shows that the proposed algorithm can facilitate better groundwater development compared with a basic genetic algorithm.