• 제목/요약/키워드: hydraulic conditions

검색결과 1,248건 처리시간 0.025초

소파안벽의 수리학적 성능에 관한 실험적 연구 (An Experimental Study on the Hydraulic Performance of Wave Dissipating Quay Walls)

  • 김인철;이태환
    • 한국해안해양공학회지
    • /
    • 제12권4호
    • /
    • pp.195-202
    • /
    • 2000
  • 최근에 항내 정온도를 향상시키고 월파량을 저감시키기 위하여 구조물 내에 공극을 두어 파의 에너지를 감쇠시키는 방법이 널리 행해지고 있다. 본 연구에서는 소파구조물 중에서 슬릿케이슨, 이글루블록 및 중공블록을 선택하여 이들의 수리학적 성능을 비교·검토하기 위하여 수리모형실험을 수행하였다. 평상파 조건에서 소파효과는 슬릿케이슨이 가장 양호한 결과를 보여주며, 설계파 조건에서 월파량의 저감효과는 슬릿케이슨과 이글루블록은 비슷하나 중공블록은 다소 저감효과가 떨어지는 경향을 보여주고 있다.

  • PDF

회파블록케이슨 방파제의 수리학적 성능에 관한 실험적 연구 (Experimental Study on Hydraulic Performance of Perforated Caisson Breakwater with Turning Wave Blocks)

  • 김인철;박기철
    • 한국해양공학회지
    • /
    • 제33권1호
    • /
    • pp.61-67
    • /
    • 2019
  • Recently, a perforated caisson breakwater with turning wave blocks was developed to improve the water affinity and public safety of a rubble mound armored by TTP. In this study, hydraulic model tests were performed to examine the hydraulic performance of a non-porous caisson and new caisson breakwater with perforated blocks for attacking waves in a small fishery harbor near Busan. The model test results showed that the new caisson was more effective in dissipating the wave energy under normal wave conditions and in reducing the wave overtopping rates under design wave conditions than the non-porous caisson. It was found that the horizontal wave forces acting on the perforated caisson were slightly larger than those on the non-porous caisson because of the impulsive forces on the caisson with the turning wave blocks.

Comparative study of CFD and 3D thermal-hydraulic system codes in predicting natural convection and thermal stratification phenomena in an experimental facility

  • Audrius Grazevicius;Anis Bousbia-Salah
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1555-1562
    • /
    • 2023
  • Natural circulation phenomena have been nowadays largely revisited aiming to investigate the performances of passive safety systems in carrying-out heat removal under accidental conditions. For this purpose, assessment studies using CFD (Computational Fluid Dynamics) and also 3D thermal-hydraulic system codes are considered at different levels of the design and safety demonstration issues. However, these tools have not being extensively validated for specific natural circulation flow regimes involving flow mixing, temperature stratification, flow recirculation and instabilities. In the present study, an experimental test case based on a small-scale pool test rig experiment performed by Korea Atomic Energy Research Institute, is considered for code-to-code and code-to-experimental data comparison. The test simulation is carried out using the FLUENT and the 3D thermal-hydraulic system CATHARE-2 codes. The objective is to evaluate and compare their prediction capabilities with respect to the test conditions of the experiment. It was observed that, notwithstanding their numerical and modelling differences, similar agreement results are obtained. Nevertheless, additional investigations efforts are still needed for a better representation of the considered phenomena.

유압공급장치의 동특성에 관한 연구 (Study of the dynamic characteristics of a hydraulic power supply)

  • 이성래
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.1172-1177
    • /
    • 1993
  • Dynamic characteristics of a hydraulic power supply are studied theoretically and computationally. The transfer function between the supply pressure and the load flow is derived considering relief valve dynamics, accumulator dynamics, and flow line dynamics. Frequency responses and time responses are obtained in many conditions using the transfer function and nonlinear mathematical model respectively.

  • PDF

유량지속곡선을 이용한 수문특성별 한강수계 총량관리 단위유역의 오염기여도 추정 (Estimation of Pollution Contribution TMDL Unit Watershed in Han-River according to hydrological characteristic using Flow Duration Curve)

  • 김동영;윤춘경;이한필;최재호;황하선
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.497-509
    • /
    • 2019
  • After the Total Maximum Daily Loads(TMDLs) was applied, it became beyond the limit of concentration management. However, it does not adequately reflect the characteristics of various watersheds, and causes problems with local governments because of the standard flow set. Thus, in this study, the Han River system is organized into four groups in estimating the Pollution Contribution by applying the Flow Duration Curve(FDC) created by the daily flow of data from the HSPF. And the method of this study is expected to be valuable as basic data for the TMDLs. As a result, Group I contains the main watersheds with no large hydraulic structures and tributary watersheds. There is no specificity in the FDC and the Pollution Contribution is estimated as rainfall runoff. Group II contains watersheds near the city where the FDC is maintained above a certain level during the Low Flow Conditions and the Pollution Contribution is estimated as the discharge flow of large scale point pollution facilities. Group III contains the main watersheds in which the large hydraulic structures are installed and FDC is curved in the Low Flow Conditions. So the Pollution Contribution is estimated as the water quality of the large hydraulic structures. Group IV contains the upstream in mainstream watersheds in which the large hydraulic structures are installed and the FDC is disabled before the Low Flow Conditions. As the flow is concentrated in the High Flow Conditions, the non-point pollution sources are estimated as the Pollution Contribution.

회동수원지의 정수처리 공정을 위한 DAF pilot plant 운영 성능평가 (Operation evaluation of DAF pilot plant for water treatment process in Hoedong Reservoir)

  • 맹민수;;김동현;신귀암;독고석
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.463-471
    • /
    • 2020
  • A 1,000 ㎥/d DAF(dissolved air flotation) pilot plant was installed to evaluate the performance of the floating process using the Nakdong River. Efficiency of various DAF operations under different conditions, such as hydraulic loading rate, coagulant concentration was evaluated in the current research. The operation conditions were evaluated, based on the removal or turbidity, TOC(total organic carbon), THMFP(trihalomethane formation potential), Mn(manganese), and Al(aluminum). Also, particle size analysis of treated water by DAF was performed to examine the characteristics of particles existing in the treated water. The turbidity removal was higher than 90%, and it could be operated at 0.5 NTU or less, which is suitable for the drinking water quality standard. Turbidity, TOC, and THMFP resulted in stable water quality when replacing the coagulant from alum to PAC(poly aluminum chloride). A 100% removal of Chl-a was recorded during the summer period of the DAF operations. Mn removal was not as effective as where the removal did not satisfy the water quality standards for the majority of the operation period. Hydraulic loading of 10 m/h, and coagulant concentrations of 40 mg/L was determined to be the optimal operating conditions for turbidity and TOC removal. When the coagulant concentration increases, the Al concentration of the DAF treated water also increases, so coagulant injection control is required according to the raw water quality. Particle size distribution results indicated that particles larger than 25 ㎛ showed higher removal rates than smaller particles. The total particel count in the treated water was 2,214.7 counts/ml under the operation conditions of 10 m/h of hydraulic loading rate and coagulant concentrations of 60 mg/L.

Monitoring of Cleanliness Level in Hydraulic Systems: Obtaining Reliable On-Line data

  • 홍정희;마이크 데이
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권2호
    • /
    • pp.28-38
    • /
    • 2012
  • Monitoring of system cleanliness levels and counting of particulate contaminant are fundamental to achieving hydraulic system reliability as any departure from the specified cleanliness level is often a precursor to future failures. On-line monitoring of cleanliness levels has the advantage of giving data both very quickly and accurately as environmental influences are eliminated. In this way, corrective actions can be promptly implemented. Most on-line instruments are sensitive to system conditions to a greater or lesser extent, but Automatic Particle Counters (APCs) working on light extinction principles are especially sensitive to the presence of optical interfaces caused by such conditions as fluid mixtures, emulsions, free water and air bubbles. These conditions give erroneous data and can result in drawing incorrect conclusions, wasting maintenance time and ultimately, reduced user confidence in cleanliness monitoring. This paper describes such conditions and shows how the correct selection of the analysis technique can result in reliable cleanliness level data.

발전설비 통풍기 날개각 제어작동기 신뢰성평가 모델 개발 (A development of reliability evaluation model for power plant fan pitch blade control actuator)

  • 손태하;허준영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3259-3263
    • /
    • 2007
  • This paper describes the proceedings of creating countermeasures after analysis and maintenance be able to conduct operation safely in a power plant. in order to operate the power plant in a stable and reliable way, the best condition of the govemor system can be maintained through the response characteristic analysis of the control device for the pitch blade control hydraulic actuator. The fan pitch blade control hydraulic actuator of a 500MW large-scale boiler is frequently operated under normal operation conditions. Common problems or malfunctions of the pitch blade control hydraulic actuators leads to the decline of boiler thermal efficiency and unexpected power plant trip. The inlet and outlet gas can be controlled by using the fan pitch blade control hydraulic actuator in order to regulate the internal pressure of the furnace and control the frequency in the power plant facility which utilizes soft coals as a power source.

  • PDF

ABS 유압 장치의 유충 현상에 관한 연구 (A Study on the Pressure Surge of ABS Hydraulic System)

  • 김병우;송창섭
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.140-147
    • /
    • 2001
  • The solenoid valve in ABS hydraulics, modulator is a two directional on-off valve and is controlled by around 100Hz high speed pulse width modulation. When the inlet valve is switched from open state to closed state, there are braking force degration, noise and vibration due to pressure surge phenomena in the hydraulic line and wheel cylinder. In this study, identifies pressure surge phenomenon in the braking process of a ABS, and investigates the way to reduce the phenomenon. For the purpose theoretical analysis on the pressure surge in the closed state hydraulic line, characteristic curve method based on wave equation was utilized. During this analysis, we could find pressure surge characteristics change due to hydraulic line change and PWM control conditions. In conclusion, by using the results of this study for the pressure surge prediction and reduction method, we could expect braking performance enhancement in Anti-Lock Braking System.

  • PDF

RLSM 방법을 이용한 전기 유압 서보 시스템의 파라미터 추정에 관한 연구 (A Study on the Parameters Estimation of Electro-Hydraulic Servo Systems Using RMSM)

  • 김병우;허진
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1510-1514
    • /
    • 2011
  • In this paper, linear discrete model of the electro-hydraulic servo system are made for parameters estimation. The parameters of electro-hydraulic servo system are estimated using the recursive least square method. Persistent excitation conditions are studied in order to estimate parameters of electro-hydraulic servo system to real values and parameters estimation affections are studied due to the forgetting factors variation. As the results, An parameter estimation method has been synthesized for minimizing the error between reference and error.