• Title/Summary/Keyword: hydration structure

Search Result 288, Processing Time 0.025 seconds

An Experimental Study on Cooling of Hydration Heat of Mass Concrete Structure using Pulsating Heat Pipe in Summer Season (진동형 히트 파이프를 이용한 하계 매스 콘크리트의 수화열 냉각에 관한 실험적 고찰)

  • Yang, Tae-Jin;Kim, Jeong-Hoon;Kim, Jong-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.51-57
    • /
    • 2007
  • In process of reinforced concrete (RC) box structure. the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete. this paper reports results of hydration heat control in mass concrete structure using the pulsating heat pipe. There were three RC box molds($1.2{\times}l.8{\times}2.4m^3$) which shows a difference as compared with each other. One was not equipped with pulsating heat pipe. The others were equipped with pulsating heat pipe. All of them were cooled with natural air convection. The pulsating heat pipe was composed of serpentine type copper pipe with 10 turns (outer diameter: 4mm. inner diameter: 2.8mm). The working fluid was R-22 and its charging ratio was 40% by volume. The conditions such as the number of turns. the length and the pitch of the pulsating heat pipe and the size of concrete structure were changed. Based on these experiments, it was confirmed that this construction method using pulsating heat pipe was effective to remove hydration heat of mass concrete structure and thus it was possible to prevent harmful thermal crack and construction Period and costs of concrete structure would be cut down.

A Study on the Hydration Ratio and Autogenous Shrinkage of Low Water/cement Ratio Paste (저물시멘트비 페이스트의 시멘트수화율 및 자기수축에 관한 연구)

  • Hyeon, Cheol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.385-390
    • /
    • 2002
  • Autogenous shrinkage of concrete has been defined as decrease in volume due to hydration cement, not due to other causes such as evaporation, temperature change and external load and so on. For ordinary concretes, autogenous shrinkage is so little compared to the other deformations that it has been dignored. It has recently been proved, however, that autogenous shrinkage considerably increase with decrease in water to cement ratio. And it has been reported that cracking can be caused by autogenous shrinkage, when high- strength concretes were used. In this study, we propose an analytical system to represent autogenous shrinkage in cement paste in order to control crack due to autogenous shrinkage. The system is composed with the hydration model and pore structure model. Contrary to the usual assumption of uniform properties in the hydration progress, the hydration model to refine Tomosawa's represents the situation that inner and outer products are made in cement paste. The pore structure model is based upon the physical phenomenon of ion diffusion in cement paste and chemical phenomenon of hydration in cement particle. The proposed model can predict the pore volume ratio and the pore structure in cement paste under variable environmental conditions satisfactorily The autogenous shrinkage prdiction system with regard to pore structure development and hydration at early ages for different mix-proportions shows a reasonable agreement with the experimental data.

  • PDF

Analysis of Heat of Hydration and Thermal Stresses in Mass Concrete (매스 콘크리트의 수화열과 온도 응력 해석)

  • 박영진;김진근;전상은;방기성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.281-286
    • /
    • 1999
  • Nonlinear temperature distribution induced by the hydration heat generates thermal stress in mass concrete. At early ages, such thermal stress may induce thermal cracks in the structure which can affect on the durability and safety of the structure. Up to now, a lot of works have focused on the prediction of temperature distribution and thermal stress in the structure. In most of such works, however, the inside of structure was considered as adiabatic state to predict temperature distribution and the thermal stress. And due to the lacks of appropriate analysis models after crack, there was little research on the crack occurrence. This paper deals with the prediction of the temperature distribution in the structure using the rate of hydration heat generation and also estimates the behavior of structure before and after cracking due to hydration heat using crack band model.

  • PDF

Reduction of Hydration Heat in Division-Placed Mass Concrete Considering the Difference of Setting Time in Super Retarding Agents (초지연제의 응결시간차에 따라 분할타설된 매스 콘크리트의 수화열 저감)

  • Gi, Suck;Pei, Zheng-Lie;Hwang, Yin-Seong;Yoon, Chi-Whan;Kim, Gi-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.805-808
    • /
    • 2002
  • This study is designed to reduction of hydration heat of 4 layer division-placed mass concrete considering the difference of setting time of super retarding agent. According to the results, peak temperature of plain concrete by hydration heat show $63^{\circ}C$ around the age of 1 days. Hydration heat is lowest in the bottom layer, and highest in the middle of 3rd layer from the bottom. Hydration heat of mock up structure, which is division-placed at the same interval of 1 and 2 days by setting time difference of super retarding agent, is highest in the bottom layer because after peak temperature of 4th layer, hydration reaction progresses in order of 3rd, 2nd and 1st layer. But in mock up structure which is division-placed at the various interval. peak temperature by hydration heat is reduced by about $13^{\circ}C$, compared with plain concrete because after first peak hydration heat of 4th layer (plain concrete), hydration reaction progresses after the drop of hydration heat in order of 3rd, 2nd and 1st layer.

  • PDF

Micromechanics based Models for Pore-Sructure Formation and Hydration Heat in Early-Age Concrete (초기재령 콘크리트의 세공구조 형성 및 발영특성에 관한 미시역학적 모델)

  • 조호진;박상순;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.123-128
    • /
    • 1999
  • Recently, as a performance based design concept is introduced, assurance of expected performances on serviceability and safety in the whole span of life is exactly requested. So, quantitative assessments about durability related properties of concrete in early-age long term are come to necessary, Especially in early age, deterioration which affects long-term durability performance can be occurred by hydration heat and shrinkage, so development of reasonable hydration heat model which can simulate early age behavior is necessary. The micor-pore structure formation property also affects shrinkage behavior in early age and carbonations and chloride ion penetration characteristic in long term, So, for the quantitative assessment on durability performance of concrete, modelings of early age concrete based on hydration process and micor-pore structure formation characteristics are important. In this paper, a micromechanics based hydration heat evolution model is adopted and a quantitative model which can simulate micro-pore structure development is also verified with experimental results. The models can be used effectively to simulate the early-age behavior of concrete composed of different mix proportions.

  • PDF

Study on the Mechanical Extraction Properties of Tobacco Stem Biomass (담배 주맥 바이오매스의 압착추출특성 연구)

  • Sung, Yong-Joo;Han, Young-Lim;Rhee, Moon-Soo
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.40 no.2
    • /
    • pp.65-72
    • /
    • 2008
  • This work evaluated the extractability of tobacco stem biomass for the papermaking type Reconstituted Tobacco Sheet(RTS). The effects of the soaking conditions on the hydration of stem biomass and the effects of the hydrated state on the mechanical extraction were investigated. In order to simulate the mechanical expression process of a papermaking type RTS mill, for example, the screw press process, the novel mechanical pressing analyzer was developed for this study. The hydration of stem biomass by soaking process was greatly affected by the soaking time and the soaking temperature. The longer soaking time and the higher soaking temperature resulted in the higher hydrated stem biomass. Since the higher hydrated stem had more combined water in the inner structure and resulted in the more flexible structure, the higher hydrated stem leaded to the more compressed filter cake and the higher water contents in the filter cake after the mechanical pressing. The pilot pulping experiments showed the difference in hydration and extractability between burley and bright tobacco stem. The bulkier structure of the burley stem resulted in the faster hydration by pilot pulping and leaded to the larger reduction in water soluble components. And the hydration process showed the major influence on the separation efficiency of water soluble components.

A study of structure modeling of the stratum corneum on the hydration (보습상태에서 피부각질의 구조 모델링에 관한 연구)

  • Kim, Jeong-Lae;Kim, Hye-Ju
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.3
    • /
    • pp.31-36
    • /
    • 2017
  • We are made up to the variation of the structure modeling of the stratum corneum by the skin on the hydration. The given skin structure is consist of the control level of the intercellular route and transcellular route, and is confirmed to the variation of the modeling for algorithm. Hydration condition is consisted to modeling by the size, form and combination, that skin impedance is appeared to result the value of measurement by the several layer such as forms of ${\xi}-R-SC-RH$, ${\xi}-R-SL-RH$, ${\xi}-R-SG-RH$, ${\xi}-R-SS-RH$ and ${\xi}-R-SB-RH$. Hydration condition is showed to the alteration difference value of S-Corneum, S-Lucidum, S-Granulosum, S-Spinosum and S-Basale. And, composition condition was constructed with the alteration modeling that was established to separate the division parts for conversion system. We will be possible to progress the improvement effectiveness of the skin and to consist of the continuous hydration control system for functional on the skin. We will be possible to progress the improvement effectiveness of the skin and to consist of the continuous penetration control system for functional energy on the skin.

The Control of Hydration Heat by Using Liquefied Nitrogen in Mass Concrete Structures (액화질소를 이용한 매스 콘크리트 구조물의 수화열 제어)

  • Yang, In-Hwan;Eo, Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1151-1156
    • /
    • 2000
  • Temperature rise and restraint condition in mass concrete structures may induce the cracks at early ages. The method to prevent the cracks induced by heat of hydration has become the major concern in mass concrete structure. Therefore, the purpose of this study is to propose a method to control heat of hydration in mass concrete structures by using cryogenic liquefied nitrogen. The method in this study was applied to actual mass concrete structure to prevent the occurrence of thermal cracks at early ages. The surface observation of structure during more than one month shows that there are seldom cracks. This represent that the method in the study is effective in the control of heat of hydration.

  • PDF

A Counterplan of temperature crack control by a heat of hydration of Subway concrete box structure concerned External Temperature (대기온도를 고려한 지하철 콘크리트 Box 구조물의 수화열에 의한 온도균열제어 대책)

  • Roh, Hyun-Sup;Kim, Eun-Kyum;Yang, Sin-Chu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.581-584
    • /
    • 2007
  • The subway concrete box structure can`t establish expansion joint because of animal power delivery of the subway rail. In this case, As increase of structure volume, it is subjected to cause temperature crack. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, examined a condition of temperature crack occurrence by a heat of hydration concerned external temperature from analysing by a three dimensional finite element method.

  • PDF