• 제목/요약/키워드: hybrid flux

검색결과 246건 처리시간 0.024초

PM Assisted, Brushless Wound Rotor Synchronous Machine

  • Ali, Qasim;Atiq, Shahid;Lipo, Thomas A.;Kwon, Byung-il
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.399-404
    • /
    • 2016
  • This paper presents a new permanent magnet (PM) assisted topology for a recently introduced brushless wound rotor synchronous machine (BL-WRSM) [1]. The BL-WRSM had a dual-inverter configuration for generating a composite magneto motive force (MMF) with a fundamental component and a subharmonic component. The subharmonic component of the MMF is used for brushless excitation of the rotor. In this paper, additional PMs were introduced on the rotor of the BL-WRSM, making it a hybrid BL-WRSM. We also discussed the flux weakening operation for the hybrid BL-WRSM. The hybrid BL-WRSM offered advantages for starting the machine and provided better performance under full-load conditions. The finite element method (FEM) was used to analyze the performance of the hybrid BL-WRSM, and we compared its performance with BL-WRSM. Finally, prototypes were built with and without the PM-assistance, and experiments were conducted to demonstrate their performance.

Study of Lower Hybrid Current Drive for the Demonstration Reactor

  • Molavi-Choobini, Ali Asghar;Naghidokht, Ahmad;Karami, Zahra
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.711-718
    • /
    • 2016
  • Steady-state operation of a fusion power plant requires external current drive to minimize the power requirements, and a high fraction of bootstrap current is required. One of the external sources for current drive is lower hybrid current drive, which has been widely applied in many tokamaks. Here, using lower hybrid simulation code, we calculate electron distribution function, electron currents and phase velocity changes for two options of demonstration reactor at the launched lower hybrid wave frequency 5 GHz. Two plasma scenarios pertaining to two different demonstration reactor options, known as pulsed (Option 1) and steady-state (Option 2) models, have been analyzed. We perceive that electron currents have major peaks near the edge of plasma for both options but with higher efficiency for Option 1, although we have access to wider, more peripheral regions for Option 2. Regarding the electron distribution function, major perturbations are at positive velocities for both options for flux surface 16 and at negative velocities for both options for flux surface 64.

$\cdot$전동 복합기능의 접이식 휠체어 개발 (Development of the Foldable Manual/Power Hybrid Wheelchair)

  • 최영철;이근민;최화순;서영택
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.172-180
    • /
    • 2006
  • Although there existed many types of manual/power hybrid wheelchairs, their use was not widespread because of their inconvenience in converting drive system and in folding frames. To carry a wheelchair in the car or to convert driving methods, some hard work of disassembling or exchanging wheels was required for most of currently available hybrid wheelchairs. In this study, the standard foldable manual wheelchair was reformed to a power wheelchair by installing the newly developed Axial Flux Permanent Magnet(AFPM) type of brush less direct current(BLDC) motor on each rear hub of wheelchair. This wheelchair could be driven by manual or electric power without exchanging. wheels, thus no additional work was needed for carriage or for power conversion. The developed wheelchair was evaluated for durability, stability, maneuverability, cost, and reliability in accordance with the Korean standards. The results indicated that the developed hybrid wheelchair was good enough for commercialization comparing to other imported wheelchairs.

자연유기물을 처리하는 혼합 오존-세라믹 한외여과 시스템에서 물리화학적 특성이 투과플럭스에 미치는 영향 (Physicochemical Effect on Permeate Flux in a Hybrid Ozone-Ceramic Ultrafiltration Membrane Treating Natural Organic Matter)

  • 김정환
    • 멤브레인
    • /
    • 제18권4호
    • /
    • pp.354-361
    • /
    • 2008
  • 자연유기물을 처리하는 혼합 오존-세라믹 한외여과 수처리 시스템에서 막의 운전조건과 처리수의 화학적 조성이 세라믹 막의 투과플럭스에 미치는 영향을 연구하였다. 오존주입량, 막간압력 그리고 교차흐름속도를 포함한 운전조건의 영향을 관찰한 결과, 막의 투과플럭스는 오존주입량과 교차흐름속도가 증가할수록 그리고 막간압력이 감소할수록 증가하였다. 오존주입으로 인한 막오염의 감소는 교차여과에서 오존기체방울에 의해 발생하는 오염물질의 물리적인 역수송보다는 촉매 금속산화물로 이루어진 세라믹막 표면에서 발생하는 오존과 자연유기물간의 화학반응에 의한 영향에 더욱 의존할 수 있음을 확인하였다. 그러나 이와 같은 막오염의 감소는 상대적으로 높은 막간압력을 적용 시 줄어드는 경향을 나타내었다. 모델 자연유기물을 이용하여 실험한 결과, 높은 pH에서는 칼슘의 첨가로 인해 투과플럭스가 급격하게 감소하였으나 상대적으로 낮은 pH에서는 투과플럭스 감소에 대한 칼슘의 효과는 저하되었다. 혼합 오존-세라믹만 시스템에서 연속적인 오존주입은 세라믹막 표면에서 발생하는 촉매오존산화에 의한 자연유기물의 분해로 운전 초기 막의 투과플럭스의 감소 후 궁극적으로는 막의 투과플럭스를 회복시킬 수 있음을 확인할 수 있었다.

핵연료집합체 지지격자의 혼합날개 형상이 임계열유속에 미치는 영향 (Effect of Mixing Vane Shapes of Spacer Grids in Nuclear Fuel Assembly on Critical Heat Flux)

  • 신창환;추연준;문상기;천세영;전태현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2396-2401
    • /
    • 2007
  • Freon CHF experiments are carried out to investigate the CHF enhancements by mixing vane shapes of spacer grids in nuclear fuel assembly. The experiments were performed for a wide range mass flux, 50$\sim}$3000 kg/$m^2s$. Three kinds of spacer grids in 5${\times}$5 rod bundles are tested: no mixing vane grids, hybrid mixing vane grids, and split mixing vane grids. The CHF performances are compared along with the data belong to the PWR operating conditions based on a water equivalence through a fluid-to-fluid modeling method. The average of the data in this range is 16.4% for 37 data of hybrid vane grid and 12.5% for 24 data of split vane. In the lower mass flux, however, the split vane grid shows slightly higher performance than the hybrid vane grid.

  • PDF

하수 2차 처리수 재이용을 위한 hybrid 응집-UF 막분리 공정의 적용 (Application of Coagulation-UF Hybrid Membrane Process for Reuse of Secondary Effluent)

  • 이철우;손정기;손인식;한승우;강임석
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.605-612
    • /
    • 2005
  • The objective of this study was to evaluate the factors affecting the optimization of coagulation hybrid UF membrane processes for the reuse of secondary effluent from sewage treatment plant. The experimental results obtained from the UF membrane process showed that organic colloids in the size range of $0.2{\mu}m{\sim}1.0{\mu}m$ caused the most substantial influence on the fouling of UF membrane. When using a coagulation pretreatment to UF membrane, alum dosage of 50mg/L resulted in the least reduction in membrane permeate flux. Also, for the rapid mixing process, in-line mixer type was more efficient for organic removal than back mixer type. Therefore, it may be concluded that coagulation-UF hybrid membrane process comparing to UF alone process showed not only higher removal efficiency of organic matter, but also substantial improvement of permeate flux of UF membrane.

Design of Linear Transverse Flux Machine for Stelzer Machine using Equivalent Magnet Circuit and FEM

  • Jeong, Sung-In
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1596-1603
    • /
    • 2018
  • This paper presents the new design and validation process of the linear transverse flux machine of the stelzer machine for hybrid vehicle application. A linear transverse flux machine is a novel electric machine that has higher force density and power than conventional electric machine. The process concentrates on 2-dimensional and 3-dimensional analysis using equivalent magnetic circuit method considering leakage elements and it is verified by finite element analysis. Besides the force characteristics of all axis of each direction are analyzed. The study is considered by dividing the transverse flux electric excited type and the transverse flux permanent magnet excited type. Additionally three-dimensional analysis in this machine is accomplished due to asymmetric structure with another three axes. Finally, it suggests the new design and validation process of linear transverse flux machine for stelzer machine.

Modeling and Experimental Validation of 5-level Hybrid H-bridge Multilevel Inverter Fed DTC-IM Drive

  • Islam, Md. Didarul;Reza, C.M.F.S.;Mekhilef, Saad
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.574-585
    • /
    • 2015
  • This paper aims to improve the performance of conventional direct torque control (DTC) drives proposed by Takahashi by extending the idea for 5-level inverter. Hybrid cascaded H-bridge topology is used to achieve inverter voltage vector composed of 5-level of voltage. Although DTC is very popular for its simplicity but it suffers from some disadvantages like- high torque ripple and uncontrollable switching frequency. To compensate these shortcomings conventional DTC strategy is modified for five levels voltage source inverter (VSI). Multilevel hysteresis controller for both flux and torque is used. Optimal voltage vector selection from precise lookup table utilizing 12 sector, 9 torque level and 4 flux level is proposed to improve DTC performance. These voltage references are produced utilizing a hybrid cascaded H-bridge multilevel inverter, where inverter each phase can be realized using multiple dc source. Fuel cells, car batteries or ultra-capacitor are normally the choice of required dc source. Simulation results shows that the DTC drive performance is considerably improved in terms of lower torque and flux ripple and less THD. These have been experimentally evaluated and compared with the basic DTC developed by Takahashi.

다중 퍼지제어기를 이용한 유도전동기의 직접 토크제어 (Direct Touque Control of Induction Motor Using Multi Fuzzy Controller)

  • 문주희;고재섭;최정식;강성준;장미금;백정우;정동화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.585-586
    • /
    • 2010
  • An induction motor operated with a conventional direct self controller(DSC) shows a sluggish response during startup and under changes of torque command. Fuzzy logic controller(FLC) is used in conjunction with DSC to minimize these problems. A FLC chooses the switching states based on a set of fuzzy variables. Flux position, error in flux magnitude and error in torque are used as fuzzy state variables. Fuzzy rules are determinated by observing the vector diagram of flux and currents. This paper proposes hybrid FLC for direct torque control(DTC) of induction motor drives. This controller is controlled speed using hybrid FLC. The performance of the proposed induction motor drive with hybrid FLC is verified by analysis results at various operation conditions.

  • PDF

Procedural steps for reliability evaluation of ultrasonically welded REBCO coated conductor lap-joints under low cycle fatigue test condition

  • Michael De Leon;Mark Angelo Diaz;Hyung-Seop Shin
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권4호
    • /
    • pp.28-31
    • /
    • 2023
  • This study presents a comprehensive procedure for the low cycle fatigue test of ultrasonically welded (UW) coated conductor (CC) lap-joints. The entire process is examined in detail, from the robust fabrication of the UW REBCO CC joints to the reliability testing under a low number of repeated cycle fatigue conditions. A continuous Ic measurement system enables real-time monitoring of Ic variations throughout the fatigue tests. The study aims to provide a step-by-step procedure that involves joint fabrication, electromechanical property (EMP) tests under uniaxial tension for stress level determination, and subsequent low-cycle fatigue tests. The joints are fabricated using a hybrid method that combines UW with adding In-Sn soldering, achieving a flux-free hybrid welding approach (UW-HW flux-free). The selected conditions for the low cycle fatigue tests include a stress ratio of R=0.1 and a frequency of 0.02 Hz. The results reveal some insights into the fatigue behavior, irreversible changes, and cumulative damage in the CC joints.