JSI TRIGA fuel rod reactivity worth experiments for validation of Serpent-2 and RAPID fuel burnup calculations

  • Anze Pungercic;Alireza Haghighat;Luka Snoj
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3405-3424
    • /
    • 2024
  • Reactivity worth of fuel rods at the JSI TRIGA research reactor was measured. Differently burned fuel rods were chosen to validate fuel burnup calculations. Two methods of measuring reactivity worth of fuel rods are used, traditional method is compared to newly introduced method using fuel rods swapping. Connection between both methods is described theoretically and the theory is validated experimentally. Fuel rod worth calculated using the newly introduced fuel rod swap method was within 1σ of worth measured using the traditional method. In addition to the recently performed experiments, weekly measurements of reactor core reactivity throughout the operational history are used for validation. The measured data were used to validate the fuel burnup and core criticality calculations. Fuel burnup calculations are performed using three different computer codes: the deterministic TRIGLAV, the Monte Carlo Serpent-2, and the hybrid RAPID. Great agreement was observed for Serpent-2 and RAPID by simulating fuel rod worth and its burnup, indicating that the fuel burnup and criticality calculations are accurate and that reactivity changes due to small burnup differences on the order of 10 pcm can be accurately simulated. In addition it was shown using ex-core detectors and large fission chamber that detector response changes due to fuel swapping are evident for fuel rod burnup differences of 20 MWd/kg. Fuel burnup calculations were further validated on excess reactivity measurements for three mixed TRIGA cores. The calculated burnup reactivity coefficient ΔρBU using Serpent-2 and RAPID was within 1σ of the measurements, showing both codes are capable of calculating burnup for different TRIGA fuel types.

QUANTITATIVE COMPARISON OF PERMEABILITY IN THE ADHESIVE INTERFACE OF FOUR ADHESIVE SYSTEMS (열순환 후 상아질 접착 계면의 수분 투과성 변화에 대한 정량적 분석)

  • Chang, Ju-Hea;Yi, Kee-Wook;Kim, Hae-Young;Lee, In-Bog;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • The purpose of this study was to perform quantitative comparisons of water permeable zones in both the adhesive and the hybrid layer before and after thermo cycling in order to assess the integrity of the bonding interface. Twenty eight flat dentin surfaces were bonded with a light-cured composite resin using one of four commercial adhesives [OptiBond FL (OP), AdheSE (AD), Clearfil SE Bond (CL). and Xeno III (XE)]. These were sectioned into halves and subsequently cut to yield 2-mm thick specimens; one specimen for control and the other subjected to thermocycling for 10,000 cycles. After specimens were immersed in ammoniacal silver nitrate for 24 h and exposed to a photo developing solution for 8 h, the bonded interface was analyzed by scanning electron microscopy (SEM) and wavelength dispersive spectrometry (WDS) at five locations per specimen. Immediately after bonding. the adhesive layer of OP showed the lowest silver uptake, followed by CL, AD. and XE in ascending order (p < 0.0001); the hybrid layer of CL had the lowest silver content among the groups (p = 0.0039). After thermocycling, none of the adhesives manifested a significant increase of silver in either the adhesive or the hybrid layer. SEM demonstrated the characteristic silver penetrated patterns within the interface. It was observed that integrity of bonding was well maintained in OP and CL throughout the thermocycling process. Adhesive-tooth interfaces are vulnerable to hydrolytic degradation and its permeability varies in different adhesive systems, which may be clinically related to the restoration longevity.

The Study on Characteristic Composition of As in a-Se with X-ray Detection Sensor using $CaWO_4/a-Se$ (다층구조($CaWO_4/a-Se$) 기반의 X선 검출센서에서 a-Se에 첨가된 As의 특성비 연구)

  • Choe, Jang-Yong;Lee, Dong-Gil;Sin, Jeong-Uk;Kim, Jae-Hyeong;Nam, Sang-Hee;Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.432-435
    • /
    • 2002
  • The ultimate study of this research is to improve the properties of digital X-ray receptor based on amorphous selenium. There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. But each two systems have strength and weakness. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. ln this study, we investigated the electrical characteristic of multi-layer$(CaWO_4+a-Se)$ as a photoconductor according to the changing iodine composition ratio. The iodine composition ratio of a-Se compound is classified into 5 different kinds which have 30ppm, 100ppm, 300ppm, 500ppm, 700ppm and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 700ppm iodine showed good characteristic of $2.53nA/cm^2$ dark current and $479nC/cm^2{\cdot}mR$ net charge at $3V/{\mu}m$.

  • PDF