• Title/Summary/Keyword: hybrid connection

Search Result 217, Processing Time 0.02 seconds

Characteristics of Hybrid-Type SFCL according to the Parallel Connection of Secondary Windings (2차권선의 병렬연결에 따른 하이브리드형 초전도 한류기의 특성)

  • Hwang, Jong-Sun;Cho, Yong-Sun;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.208-211
    • /
    • 2006
  • We have analyzed operating characteristics of hybrid-type superconducting fault current limiter (SFCL) according to the parallel connection of secondary windings with $YBa_{2}Cu_{3}O_{7}$ (YBCO) films. The turn ratio between the primary and secondary windings of each reactor was 63:21. Hybrid-type SFCL using a transformer with parallel reactors could reduce the unbalanced quench caused by differences of the critical current density between YBCO films. We found that hybrid-type SFCL having parallel connection induced simultaneous quench between the superconducting elements. The quench-starting point at this time was almost same. When the applied voltage was 200V, the limiting current in the hybrid-type SFCL with a serial connection was lowered to 34 percent than that in the SFCL with a parallel connection. In the meantime, when the voltage generated in the superconducting elements was the same, the current value in the parallel connection was 60 percent less than in the serial connection. The voltage generated in the primary winding also showed the similar behavior. In conclusion, we found that the fault current was limited more effectively in the SFCL with the serial connection but the power burden of the superconducting elements was reduced in the parallel connection.

  • PDF

Experimental study on the hybrid shear connection using headed studs and steel plates

  • Baek, Jang-Woon;Yang, Hyeon-Keun;Park, Hong-Gun;Eom, Tae-Sung;Hwang, Hyeon-Jong
    • Steel and Composite Structures
    • /
    • v.37 no.6
    • /
    • pp.649-662
    • /
    • 2020
  • Although several types of rigid shear connectors have been developed particularly to increase load-carrying capacity, application is limited due to the complicated details of such connection. In this study, push-out tests were performed for specimens with hybrid shear connectors using headed studs and shear plates to identify the effects of each parameter on the structural performance of such shear connection. The test parameters included steel ratios of headed stud to shear plate, connection length, and embedded depth of shear plates. The peak strength and residual strength were estimated using various shear transfer mechanisms such as stud shear, concrete bearing, and shear friction. The hybrid shear connectors using shear plates and headed studs showed large load-carrying capacity and deformation capacity. The peak strength was predicted by the concrete bearing strength of the shear plates. The residual strength was sufficiently predicted by the stud shear strength of headed studs or by shear friction strength of dowel reinforcing bars. Further, the finite element analysis was performed to verify the shear transfer mechanism of the connection with hybrid shear connector.

Architectures and Connection Probabilities forWireless Ad Hoc and Hybrid Communication Networks

  • Chen, Jeng-Hong;Lindsey, William C.
    • Journal of Communications and Networks
    • /
    • v.4 no.3
    • /
    • pp.161-169
    • /
    • 2002
  • Ad hoc wireless networks involving large populations of scattered communication nodes will play a key role in the development of low power, high capacity, interactive, multimedia communication networks. Such networks must support arbitrary network connections and provide coverage anywhere and anytime. This paper partitions such arbitrarily connected network architectures into three distinct groups, identifies the associated dual network architectures and counts the number of network architectures assuming there exist N network nodes. Connectivity between network nodes is characterized as a random event. Defining the link availability P as the probability that two arbitrary network nodes in an ad hoc network are directly connected, the network connection probability $ \integral_n$(p) that any two network nodes will be directly or indirectly connected is derived. The network connection probability $ \integral_n$(p) is evaluated and graphically demonstrated as a function of p and N. It is shown that ad hoc wireless networks containing a large number of network nodes possesses the same network connectivity performance as does a fixed network, i.e., for p>0, $lim_{N\to\infty} Integral_n(p)$ = 1. Furthermore, by cooperating with fixed networks, the ad hoc network connection probability is used to derive the global network connection probability for hybrid networks. These probabilities serve to characterize network connectivity performance for users of wireless ad hoc and hybrid networks, e.g., IEEE 802.11, IEEE 802.15, IEEE 1394-95, ETSI BRAN HIPERLAN, Bluetooth, wireless ATM and the world wide web (WWW).

Structural Behavior on Horizontal Connection for Hybrid Precast Concrete Panel (복합 프리캐스트 콘크리트 패널 수평접합부의 구조적 거동)

  • Lee, Sang-Sup;Park, Keum-Sung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.155-162
    • /
    • 2019
  • Hybrid precast concrete panel is a wall element that is able to quickly construct the core wall structure for moderate-rise modular buildings. Hybrid precast concrete panel has unique characteristics which is a pair of C-shaped steel beams combined at the top and bottom of a concrete wall, In this study, an improved anchorage detail for vertical rebar is proposed to ensure the lateral force resistance performance of hybrid precast concrete panel emulating monolithic concrete wall. Also, the structural performance of horizontal connection is investigated experimentally with the bolt spacing parameter. And the behavior of hybrid precast concrete panel with the improved detail is compared with the monolithic concrete wall tested in a previous study. Finally, the required thickness of C-shaped steel beam to eliminate or minimize the deformation in horizontal connection is calculated by prying action equation.

A Study on the Static Behavior of Connection for the Steel-Concrete Hybrid Girder (강-콘크리트 혼합거더 접합부의 정적 거동에 관한 연구)

  • Kim, Moon-Kyum;Lho, Byeong-Cheol;Kim, Jeong-Hoon;Park, Hyun-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.426-429
    • /
    • 2006
  • This paper focuses on the static behavior of prestressed and non-prestressed connections for the steel-concrete hybrid girder. Based on the experimental study, it is found that the girder with non-prestressed connection failed by local concrete failure at the connection area, and the studs are taken out from the concrete. In case of the girder with prestressed joint, the failure of the girder is initiated by the crack at the varying section area. The test results show that the girder with prestressed connection has higher load carrying capacity compare to the girder with non-prestressed connection by 12%. Therefore, the application of prestressing at the concrete-steel connection recommended for the more secure connection.

  • PDF

A study on rotational behaviour of a new industrialised building system connection

  • Moghadasi, Mostafa;Marsono, Abdul Kadir;Mohammadyan-Yasouj, Seyed Esmaeil
    • Steel and Composite Structures
    • /
    • v.25 no.2
    • /
    • pp.245-255
    • /
    • 2017
  • The performance of an Industrialised Building System (IBS) consists of prefabricated reinforced concrete components, is greatly affected by the behaviour of the connection between beam and columns. The structural characteristics parameters of a beam-to-column connection like rotational stiffness, strength and ductility can be explained by load-rotation relationship of a full scale H-subframe under gravitational load. Furthermore, the connection's degree of rigidity directly influences the behaviour of the whole frame. In this research, rotational behaviour of a patented innovative beam-to-column connection with unique benefits like easy installation, no wet work, no welding work at assembly site, using a hybrid behaviour of steel and concrete, easy replacement ability, and compatibility with architecture was investigated. The proposed IBS beam-to-column connection includes precast concrete components with embedded steel end connectors. Two full-scale H-subframes constructed with a new IBS and conventional cast in-situ reinforced concrete system beam-to-column connections were tested under incremental static loading. In this paper, load-rotation relationship and ratio of the rigidity of IBS beam-to-column connection are studied and compared with conventional monolithic reinforced concrete connection. It is concluded that this new IBS beam-to-column connection benefits from more rotational ductility than the conventional reinforced concrete connection. Furthermore, the semi-rigid IBS connection rigidity ratio is about 44% of a full rigid connection.

Development of Hybrid FRP-Concrete Composite Pile Connection (하이브리드 FRP-Concrete 복합말뚝의 연결부의 개발)

  • Lee, Hyoung-Kyu;Park, Joon-Seok
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.4
    • /
    • pp.52-57
    • /
    • 2014
  • Due to the advantageous mechanical properties of the fiber reinforced polymeric plastics(FRP), their application in the construction industries is ever increasing trend, as a substitute of structural steel which is highly vulnerable under hazardous environmental conditions (i.e., corrosion, humidity, etc.). In this study, hybrid FRP-concrete composite pile (HCFFT) connection is suggested. The HCFFT is consisted of pultruded FRP unit module, filament wound FRP which is in the outside of mandrel composed of circular shaped assembly of pultruded FRP unit modules, and concrete which is casted inside of the circular tube shaped hybrid FRP pile. Therefore, pultruded FRP can increase the flexural load carrying capacity, filament wound FRP and concrete filled inside can increase axial load carrying capacity. In the study, connection capacity of HCFFT(small and mid size) is investigated throughout experiments and finite element method. From the results of experiments, we suggested the connection methods about HCFFT pile connection.

A Study on the Moment Resisting Performance of the Hybrid Beam-Column Connection System with Structural Tee (T 형강을 사용한 합성골조 보-기둥 접합부의 휨 저항성능에 관한 연구)

  • 임대성;최광호;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.597-602
    • /
    • 1998
  • The composite systems, consisting of R/C Columns-Steel Beams, are reasonable structures because of their constructional and economical advantages, workability and so on. But, it is difficult to apply the composite systems to actual design due to material dissimilarity and complicate stress flow in the connection. This study aims to propose the hybrid beam-column connection system with structural tee and through experimental research make clear the shear and moment resistance capacity and stress transfer mechanism.

  • PDF

Characteristics of a Hybrid-type SFCL with Serial and Parallel Connection of Secondary Circuit (2차회로의 직.병렬연결에 따른 하이브리드형 초전도 한류기의 특성)

  • Cho, Yong-Sun;Park, Hyoung-Min;Nam, Goung-Hyun;Lee, Na-Young;Han, Tae-Hee;Choi, Choi-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.393-395
    • /
    • 2006
  • We investigated the operational characteristics of the hybrid-type superconducting fault current limiter (SFCL) according to the serial and parallel connections of secondary circuits. The hybrid-type SFCL consists of a transformer, which has a primary winding and several secondary windings with $YBa_2Cu_3O_7$ films connected in series and parallel. In order to increase the capacity of the SFCL, the serial connection between each current limiting unit is necessary. The hybrid-type SFCL with the serial connection in secondary circuits could show superior characteristics than those of the parallel connections in the current limiting and quench time. The resistances generated in the superconducting units were also lowered at the parallel connections. We confirmed that the parallel connection reduced the power burden of each superconducting unit under the same conditions because of the simultaneous quenching between superconducting units.

  • PDF

Friction-based beam-to-column connection for low-damage RC frames with hybrid trussed beams

  • Colajanni, Piero;Pagnotta, Salvatore
    • Steel and Composite Structures
    • /
    • v.45 no.2
    • /
    • pp.231-248
    • /
    • 2022
  • Hybrid Steel-Trussed Concrete Beam (HSTCB) is structural typology suitable for light industrialization. HSTCBs usually cover long span with small depths, which lead to significant amount of longitudinal rebars. The latter make beam-column joints more prone to damage due to earthquake-induced cyclic actions. This phenomenon can be avoided using friction-based BCCs. Friction devices at Beam-to-Column Connections (BCCs) have become promising solutions to reduce the damage experienced by structural members during severe earthquakes. Few solutions have been developed for cast-in-place Reinforced Concrete (RC) and steel-concrete composite Moment Resisting Frames (MRFs), because of the difficulty of designing cost-effective damage-proof connections. This paper proposes a friction-based BCC for RC MRFs made with HSTCBs. Firstly, the proposed connection is described, and its innovative characteristics are emphasized. Secondly, the design method of the connection is outlined. A detailed 3D FE model representative of a beam-column joint fitted with the proposed connection is developed. Several monotonic and cyclic analyses are performed, investigating different design moment values. Lastly, the numerical results are discussed, which demonstrate the efficiency of the proposed solution in preventing damage to RC members, and in ensuring satisfactory dissipative capacity.