• Title/Summary/Keyword: humidity condition

Search Result 1,057, Processing Time 0.021 seconds

Deformation of Flush Door Depending on Core Construction Under the Change of Environmental Condition (환경 노출 조건 하에서 심재구성에 따른 플러쉬문의 변형)

  • Jang, Sang Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.38-44
    • /
    • 2003
  • This study was carried out to evaluate the feasibility of using HDF as surface panels as well as core materials for flush door manufacturing. Six core constructions were developed and applied to manufacture door specimens and conventional skin door specimen was also manufactured for comparison. Door specimens were tested under changing interior environmental condition for 3~4 months during winter and summer seasons. During the test period, deformation of doors were measured weekly, and temperature and relative humidity of testing area were also recorded. From this study, it was concluded that HDF can be used to manufacture quality flush doors and core construction developed in this study showed good quality compared to conventional skin door. Deformation of doors increased as temperature and relative humidity of the surrounding environment increased. Flush doors generally showed less deformation than skin doors, and evaluated to be stable and good quality when compared to skin door.

An Experimental Study on Measure to Moisture Contents of Concrete (콘크리트 내부의 수분함유량 측정에 관한 실험적연구)

  • Park, Won-Sup;Kim, Heung-Youl;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.428-433
    • /
    • 2008
  • The strength capacity properties of concrete are much influenced by water content which has a significant effect on concrete spalling, especially, in high temperature areas. Therefore, the properties of the material's shall be closely examined first by measuring the water content in each material in order to analyze Concrete Fire Characteristics, and a reliable measuring method shall be presented in order to derive the following influence. The method used to measure the water content within concrete is mainly divided into 4 types; ASTM method, Nuclear Magnetic method, Ultrasonic measurement method, Radio Wave method, etc. It is essential to use a reliable measuring method for each experiment. In this experiment, we measured the water content and humidity of concrete by two methods; Relative/Absolute humidity method using VISALA HM44 measuring equipment which is easily measurable compared with other methods regardless of the shape of the experimental model, and a water content measuring experiment using ASTM C 566. If the aggregates are under the condition that their surface is dry but in saturation, there is no change of water content according to concrete curing methods. However if the aggregates are absolutely dry, the water content is significantly changed according to concrete curing methods.

  • PDF

A study on the steady-state and dynamic performance of polymer electrolyte fuel cells under various external humidification conditions (고분자 전해질 연료전지의 외부가습 조건에 따른 정상상태 및 비정상상태 성능특성 연구)

  • Lee, Yong-Taek;Kim, Bo-Sung;Kim, Yong-Chan;Choi, Jong-Min;Ko, Jang-Myoun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3407-3412
    • /
    • 2007
  • The performance characteristics of the polymer electrolyte fuel cells (PEFCs) were investigated under various humidification conditions at steady-state and transient conditions. The PEFC studied in this study was characterized by I-V curves in potentiostatic mode. The I-V curves representing steady-state performance were obtained from OCV to 0.25V, and the dynamic performance responses were obtained at some points of voltages. The anodic external humidification was applied and the humidity was controlled from 20% to 100%. The effects of relative humidity of hydrogen were measured with the dry air at the cathode. At high voltage region, the performance at high temperature was higher, but at low voltage region, low temperature condition showed the higher performance. The dynamic responses were observed at the instant when the voltage of the PEFC was changed. It was observed that the performance reached steady-state earlier with the increase of temperature.

  • PDF

Analysis on Living Factor and Actual State of Indoor Thermal Environment in Apartment Units during Winter (아파트의 겨울철 실내온열환경 실태와 생활요인 분석)

  • Choi, Yoon-Jung;Jeong, Youn-Hong
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.97-105
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor thermal environment in apartment units and to analyze the relationship between the living factors and indoor thermal elements. The field surveys consisted of measurements of physical elements and observations of living factors. In addition, the residents of 20 apartment units were interviewed to survey their subjective response. Field surveys were carried out from January to March 2007. Measuring elements were air temperature, globe temperature, and relative humidity. The results showed that the average of indoor temperature for the houses was $21.2{\sim}27.2^{\circ}C$, while 4 houses exceeded the comfort zone. The average of globe temperature for the houses was $21.3{\sim}27.5^{\circ}C$, while 6 houses exceeded the comfort zone. The mean relative humidity was $19.5{\sim}58.8%$, which is a relatively dry condition. The residents' average clothing value was $0.39{\sim}0.89$ clo(average 0.68 clo). The average thermal sensation vote on each room was $4.2{\sim}4.8$, which is 'neutral' to 'slightly warm'. Living factors had significant effect on indoor temperature in regression analysis were ventilation time(outdoor air exchange), opening time of door through balcony, and gas cooker use time.

Numerical study of heat and mass transfer around an evaporative condenser tube by multi-zone method (다중 영역법을 이용한 증발식 응축관 주위의 열 및 물질전달 해석)

  • ;;Yun, In-Chul;Yoo, Je-In
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3317-3328
    • /
    • 1995
  • The objective of the present study is to predict the characteristics of heat and mass transfer around an evaporative condenser. Numerical calculations have been performed using multi-zone method to investigate heat transfer rate and evaporation rate with the variation of inlet condition(velocity, relative humidity and temperature) of the moist air, the flow rate of the cooling water and the shape of the condenser tube. From the results it is found that the profile of heat flux is the same as that of evaporation rate since heat transfer along the gas-liquid interface is dominated by the transport of latent heat in association with the vaporization(evaporation) of the liquid film. The evaporation rate and heat transfer rate is increased as mass flow rate increases or relative humidity and temperature decrease respectively. But the flow rate of the cooling water hardly affect the evaporation rate and heat flux along the gas-liquid interface. The elliptic tube which the ratio of semi-minor axis to semi-major axis is 0.8 is more effective than the circular tube because the pressure drop is decreased. But the evaporation rate and heat flux shown independency on the tube shape.

An Experimental Study on Understanding of Production Mechanism of a Mist from Fin-Tube Heat Exchanger (핀-튜브 열교환기에서의 습증기 발생 메커니즘의 파악을 위한 실험적 연구)

  • Park, S.K.;Yoon, S.H.;Kim, K.K.;Kim, M.H.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.595-604
    • /
    • 2001
  • As an improvement in the standard of living and economic growth, the demand for air conditioning equipment is increasing rapidly. Nowadays, air conditioning equipments are being used for industry, large building, house and car. There equipments were concentrated on improving heat efficiency of economic aspects while thy design heat exchanger for cooling and heating. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore, the user demand air of high class and quality. In this experimental study, to acquire elementary data for development of heat exchanger which be able to supply air of high quality, that is to say, possess a restraint effect of mist generation. We estimate an effect on cooling plate quality, supply air velocity, supply air temperature, cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

Effect of Storage Temperature and Humidity on the Quality Stability of Potatoes (감자의 품질안정성에 대한 저장 온.습도의 영향)

  • 권중호;변명우
    • Food Science and Preservation
    • /
    • v.2 no.2
    • /
    • pp.243-249
    • /
    • 1995
  • Potatoes, Irish cobbler, were subject to quality evaluation from the physiological and physicochemical points of view during storage under different temperatures and relative humidities for 11 months. Quality criteria were sprouting, rotting, weight changes, moisture, total sugar, reducing sugar and vitamin C. Low temperature condition(LT, 2∼4$^{\circ}C$, 80% RH) was enough to preserve Potatoes for 11 months, but it was indicated to be limitations that the increase in reducig sugar as well as sprouting by about 3.3 to 6.7% occurred from the 3rd month of storage. Meanwhile, pit temperature(PT, 3∼15$^{\circ}C$, 75∼85% RH), room temperature(RT, 7∼17$^{\circ}C$, 80∼95% RH) and ambient temperature(AT, 2∼25$^{\circ}C$, 62∼72 RH) were shown infeasible conditions for the storage of potatoes mainly due to the increase In sprouting-rate and subsequent quality-loss after 3 months of storage. Based on the results, it proposed that more economical conditions, ranging 10 to 15$^{\circ}C$ and about 80% RH following sprout inhibition treatment should be used for the long-term storage of potatoes.

  • PDF

A Study on the Estimate of Thermal Environment and the Subjective Responses of the Aged during Summer in the Welfare Facilities -Focused on the Welfare Facilities for the Aged in Taegu- (노인복지시설의 하절기 실내 온열환경과 노인의 주관적 반응평가에 관한 연구 -대구광역시 소재 노인복지시설을 중심으로)

  • 이형우;홍원화
    • Journal of the Korean housing association
    • /
    • v.13 no.2
    • /
    • pp.23-29
    • /
    • 2002
  • The purpose of this study was to find out the present condition of indoor thermal environment and to investigate the environmental needs of the elderly through the measurement of outdoor and indoor physical thermal environment elements and the questionary survey of the response to thermal environment in two welfare facilities for the aged in Taegu during summer in 2001. The 38 residents among the total of 134 residents were asked to record their feelings. The result of this study was as follows. The indoor thermal environment in the facilities subjected leer this study was seemed to be comfortable comparatively. But the values of mean indoor temperature measured were about 1.6-1.8$^{\circ}C$ higher than that of a existing domestic research suggested as thermal comfort zones for the elderly during summer, and most residents fe1t somewhat hot in inner space. And the value of indoor relative humidity in one facility was out from the range of comfort humidity(40-70%). Also there were differences by the geographical location between the two.

Study on the Long-term Change of Urban Climate in Daegu (대구의 장기적 도시기후 변동에 관한 연구)

  • 김해동
    • Journal of Environmental Science International
    • /
    • v.12 no.7
    • /
    • pp.697-704
    • /
    • 2003
  • Through data analysis using the meteorological data during 40 years(1961∼2000) for 2 stations(Daegu and Chupungnyong), we studied the present condition and long-term trends in urban climatic environments of Daegu. It was found that there was about 1.5$^{\circ}C$ rise in annual mean temperature of Daegu from 1961 to 2000. On the other hand, that of Chupungnyung was not more than 0.4$^{\circ}C$ for the same period. The regional disparity in temperature changes has been caused by the difference of urban effects on climate between two regions. In particular, the urban warming appears more significant in winter season. There was about 3$^{\circ}C$ rise in annual mean daily minimum temperature of winter season(Dec.∼Feb.) in Daegu. As the result, the number of winter days continuously decreased from 115 days(1961) to 75 days(2000). The long-term trends of relative humidity were also studied to exame the effects of urbanization on climate in Daegu. It was found that there was about 7% decrease in relative humidity of Daegu during past 40 years(1961∼2000). On the other side, the decrease of Chupungnyung was not more than 2% for the same period. The long-term trends of the other climatic factors(fog days, tropical night days, etc) were also studied in this study.

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.