• Title/Summary/Keyword: humidity condition

Search Result 1,057, Processing Time 0.027 seconds

The Study on the Properties of Polymer Emulson Modified Mortar -Effects of Polyacrylicacid Ester and Polystyrene Modified Mortar- (고분자에말죤의 첨가에 따른 시멘트모르터의 특성에 관한 연구 -Polyacrylicacid Ester 및 Polystyrene 에말죤의 첨가영향-)

  • 김창은;최강순
    • Journal of the Korean Ceramic Society
    • /
    • v.12 no.4
    • /
    • pp.9-18
    • /
    • 1975
  • Polymer emulsion was used as the admixture for the purpose of increasing the mechanical properties of cement mortar. The effect of polymer emulsion admixture on compressive strength and tensile strength and chemical resistance, relative humidity on compressive and tensile strength, sand particles on water absorption were studied. The results were as follows. 1. Polymer emulson modified mortar cured under 95% of realative humidity showed lower strength than the mortar cured at dry condition. 2. The maximum strength was attained at 10~20% of polystyrene and polyacrylic acid ester polymer-cement mortar. 3. The modified mortar (sand size rate (-9+35)mech:(-35+60)mech=4 : 1) was 1.5 times lower than the modified mortar (1 : 1) in water absorption. 4. Compared with the ordinary mortar, the modified mortar showed 2~3 times greater chemical resistance for 5% HCl or 5% H2SO4.

  • PDF

An Experimental Study on Understanding of Production Mechanism of a Mist from Fin Adhesion heat Exchanger (핀 부착 열교환기에서 습증기(mist)발생 메커니즘의 파악을 위한 실험적 고찰)

  • 최권삼
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.146-152
    • /
    • 2000
  • As an improvement in the standard of living and economic growth the demand for air conditioning equipment is increasing rapidly. Nowadays air conditioning equipments are being used for industry large building house and car. Thess equipments was concentrated on improving heat efficiency of economic aspects while they design heat exchanger for cooling and heating,. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore the user demand air of high class and quality. In this experimental study to acquire elementary data for development of heat exchanger which be able to supply air of high quality that is to say possess a restraint effect of mist generation. We estimate an effect on cooling plate kind supply air velocity supply air temperature cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

Vegetation Pattern and Successional Sere in the Forest of Mt. Odae (오대산 삼림식생의 패턴과 천이계열)

  • 변두원;이호준;김창호
    • The Korean Journal of Ecology
    • /
    • v.21 no.3
    • /
    • pp.283-290
    • /
    • 1998
  • The vegetation pattern of Mt. Odae based on the soil humidity gradient showed 3 types: (1) the forest of Pinus densiflora under the mesic or xeric conditions of the low altitudinal area, (2) the forest of Acer including A. mono, A. pseudo-sieboldianum and Tilia amurensis under the submesic or subxeric conditions and (3) the forest of Quercus including Q. mongolica of the higher elevational area and Q. variabilis of the lower elevational area under the xeric condition. Water content, organic matter and total nitrogen of soil were relatively low in Pinus densiflora and Quercus variabilis communities while they were relatively high in Betula platyphylla var. japonica and Quercus mongolica communities. According to the result of cluster analysis based on similarity indices of the communities, the proposed successional sere in the forest vegetation of Mt. Odae was as follows. P. densiflora community $\longrightarrow$ P. densiflore + Q. mongolica community $\longrightarrow$ Q. mongolica + A. pseudo-sieboldianum community. P. densiflora community $\longrightarrow$ P. densiflora + Q. variabilis community $\longrightarrow$ Q. variabilis community $\longrightarrow$ Q. mongolica + Q. variabilis community $\longrightarrow$ Q. mongolica + A. pseudo-sieboldianum community.

  • PDF

Theoretical Analysis of a Recuperative Refrigeration Dehumidifier (열회수 냉각 제습기의 이론적 해석)

  • Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.1
    • /
    • pp.48-54
    • /
    • 2014
  • A refrigeration dehumidifier with a recuperative heat exchanger is theoretically analyzed. The recuperative heat exchanger is located between the two air streams from and to the dehumidifying coil, and reduces the sensible heat load in dehumidification process. A simple model is developed to predict performance of the dehumidifier. The model predicts that the recuperative heat exchanger is effective especially in the low humidity condition, where the sensible heat load is relatively large. It is predicted that, by adopting a recuperative heat exchanger, a maximum 30~110% increase in COP is possible for indoor air at $27^{\circ}C$, and 40~60% relative humidity.

Stacking Durability Analysis of Fruit , Packaging Boxes by Creep (크리이프에 의한 과실 포장입자의 층적 내구성 분석)

  • 박종민;권순홍;권순구;김만수
    • Journal of Biosystems Engineering
    • /
    • v.21 no.2
    • /
    • pp.191-197
    • /
    • 1996
  • Allowable stacking duration of the corrugated fiberboard boxes being widely used for packaging fruits and vegetables was analyzed by the creep behavior and the cumulative load correction factor for the boxes. The stacking boxes were assumed to be stored at a nearly constant temperature and relative humidity condition. When the stacking duration was short period, the stacking height determined by two methods showed a little difference between them, but almost no difference was shown as the stacking duration was longer. Allowable stacking duration was rapidly decreased with the increase of static load applied on the stacking boxes, and allowable stacking duration of Box A was estimated the longer than that of Box B. A model of allowable stacking duration for the corrugated fiberboard box was developed as a function of the stacking load and the ambient relative humidity.

  • PDF

A Study On the Property and Influence Factor in Measuring of the Dynamic Stiffness of Damping Materials (바닥충격음 완충재의 동탄성계수 특성 및 측정 영향인자)

  • Kim, Kyoung-Woo;Choi, Hyon-Jung;Kang, Jae-Sik;Yang, Kwan-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1256-1259
    • /
    • 2006
  • The purpose of this study was to investigate the current status and influence factor in measuring the dynamic stiffness of damping materials. The property of the dynamic stiffness of damping materials was tested and analysed in condition such as the size of test samples and the change of relative humidity in heating chamber. Test results showed that the dynamic stiffness of after-heating was lower than that of before-heating in most samples and the change of relative humidity in heating chamber got little influence of the dynamic stiffness. The resonant frequency of test sample decreased $2{\sim}7Hz$ as the decrease of the size of sample. Because it was increased that total mass per unit area of sample, the change of dynamic stiffness had little influence.

  • PDF

An Experimental Study on the Characteristics of Train-Wind in Underground Shopping Center Connected to Subway Station (지하도 상가와 지하 역사 연계구에서 열차풍 발생 특성에 관한 실험적 연구)

  • Hwang, In-Ju;Lee, Hong-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.82-87
    • /
    • 2005
  • The characteristics of train-wind in the underground shopping center(UGSC) connected to subway station is investigated by field measurement for the case of train movement such as arrival and departure, etc. Also air curtain installed at the pass way between underground shopping center and subway station were considered as the parameter in order to analysis the effect on indoor air quality and thermal condition. The measurement data such as velocity, relative humidity, wind-pressure were plotted as quantity variation with time scale. The train-wind affected wind velocity, air pressure and relative humidity at the connecting area of underground shopping center and subway station, and the variation was about 4.5 m/s, 8%, 40 Pa. Also the result showed that the air curtain is not proper to reduce influence of train-wind

  • PDF

Desalting Method for Removing $Cl^-$ Ions from the Exacavated Irons Objects (출토 철제 유물의 탈염 처리 방법 고찰)

  • Moon, Whan-Suk;Hwang, Jin-Ju;Jung, Young-Dong
    • 보존과학연구
    • /
    • s.17
    • /
    • pp.1-19
    • /
    • 1996
  • Desalting methods for chloride ions from the excavated iron objects were studied. These methods were compared with room temperature and heating condition of treating solution. During the Desalting treatments the $Cl^-$concentration of the solution were measured regularly and the plotted for $Cl^-$concentrations the square root of time, heating methods showed that the $Cl^-$ ions are more extracted. For the desalting treatments these plots were found to be flattening line, it was showed the changing second solution. Also, the changing solution in the room temperation detected less $Cl^-$ ions of heating treatment solution. As the examination for the relative humidity has compared for desalting objects during 8 days, it was showed a re-corroded appearance of R.H90%. As it did not detected a $Cl^-$ ions of re-corroded section, these phenomena were showed the naturally occuring corrosion of the objects in the high relative humidity.

  • PDF

Analysis of Environment Control Capability Wintering Beehouse in Young Area (용인지역 저온양봉사의 환경조절성능 분석(농업시설))

  • 이석건;김란숙;이현우;이종원
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.302-307
    • /
    • 2000
  • The wintering honey bee chambers were constructed and inside environment factors were analyzed to provide high technology for efficient wintering of honeybee colonies. As a result of this study, inside air temperature of yongin chamber under the wide range of outside temperature condition was found to be appropriated for wintering of bee, and inside temperature of beehive was about 2$^{\circ}C$ higher than the air temperature in the chamber. The fan operation schedule did not control the high temperature down properly in the chamber, It was necessary to find a new fan operation schedule to be able to provide the optimum temperature for wintering honey bee colonies. inside humidity variation of Yongin chamber was very much depended on outside humidity.

  • PDF

A Study on the engineering Properties of Repairing Epoxy-Mortar According to Hardener types for Structures under Underwater and Humidity (수중 및 습윤 환경구조물 보수용 에폭시 모르타르의 경화제 종류에 따른 공학적 특성에 관한 연구)

  • Park Duk Jun;Park Sang Hun;Lee Dae Kyung;Bae Kee Sun;Kim Jin Man;Back Sin Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.277-280
    • /
    • 2005
  • Epoxy-mortar composites have been wildly used as finishing and repairing materials in the construction because of their excellent properties. Conventional epoxy-mortars and concretes have an inferior applicability and cost performance ratio due to the two component mixing of the epoxy resin and hardener. In this study, we examined the engineering effect of compressive strength and flexible strength according to the various epoxy-hardener in underwater and humidity environment, and evaluated the hardener types and physical effect of Epoxy mortar using cement binder in underwater and air condition. In this study, it was clarified that the engineering properties of repairing epoxy-motars were effected by the type of hardener.

  • PDF