• 제목/요약/키워드: human-to-human (H2H)

검색결과 3,601건 처리시간 0.046초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

다시마 분말과 밥을 첨가한 햄버거 패티의 품질 특성 (Quality Characteristics of the Hamburger Patties with Sea Tangle (Laminaria japonica) Powder and/or Cooked Rice)

  • 오현경;임현숙
    • 한국축산식품학회지
    • /
    • 제31권4호
    • /
    • pp.570-579
    • /
    • 2011
  • 본 연구는 생리활성이 높은 다시마와 소비를 촉진해야 할 쌀을 이용하여 햄버거 패티가 지닌 고에너지, 고지방 및 고콜레스테롤의 문제점을 해결하면서 건강기능성이 향상된 패티를 개발하고자 수행되었다. 표준패티는 지방을 첨가하지 않는 재료 조성으로 제조하였고, 세 종류의 실험패티는 표준패티 재료 중 육류의 2.5%를 다시마 분말로 대체한 패티 L과 육류의 25% 또는 50%를 동 분말을 함유한 밥으로 대체한 패티 LI과 LII이었다. 이들 세 종류의 실험패티에 대해 일반성분과 나트륨 및 콜레스테롤 함량을 분석했고, 품질 특성을 측정했으며, 관능성과 기호도를 평가했다. 실험패티의 일반성분은 표준패티와 크게 달라졌다. 즉 탄수화물 함량은 L은 낮았으나 LI과 LII는 높았고, 조지방과 콜레스테롤 함량은 세 실험패티 모두 낮았는데 LII와 LI은 더욱 낮았으며, 조단백 함량은 LI과 LII만 낮았다. 회분과 나트륨 함량은 세 실험패티 모두 높았는데 이중에서도 L이 가장 높았다. 실험패티의 품질특성도 표준패티와 상당히 변화되었다. 즉 가열 후 중량 감소율은 세 실험패티 모두 낮았는데 LII가 가장 낮았으며, 직경 감소율은 세 실험패티 모두 적었고, 반면에 두께 감소율은 L과 LII가 높았다. 색도는 세 실험패티 모두 명도와 적색도가 낮은 반면에 황색도는 높았다. 수분 함량은 세 실험패티 모두 높았는데 특히 LI과 LII가 크게 높았다. pH 값은 세 실험패티 모두 높았다. 경도는 L은 높았으나 반대로 LI과 LII는 낮았다. MDA 함량은 세 실험패티 모두에서 낮았으며, LII, LI 및 L 순으로 낮았다. 패티의 관능평가 결과, LI과 LII는 표준패티에 비해 대칭성, 색상, 윤기, 경도 및 다즙성이 우수하였고, 향미, 이취, 고소함, 느끼함, 맛, 이미 등 6개 항목을 같았다. 패티의 기호도 평가에서는 세 실험패티 모두 표준패티에 비해 윤기가 높았고, 이외에 전체 풍미를 포함한 11개 항목은 동일하였다. 이들 패티를 이용하여 제작한 버거의 기호도 역시 전체 풍미를 비롯한 10개 항목은 모두 차이를 보이지 않았다. 이러한 본 연구결과는 패티 재료 중 육류의 2.5%를 다시마 분말로 대체하거나 25% 또는 50%를 동 분말을 함유한 밥으로 대체하면 패티의 수분 함량은 높아지고, 에너지와 지방 및 콜레스테롤 함량은 낮아지며, 품질 특성에 긍정적인 효과가 있고 또한 관능성이나 기호도에 바람직한 영향을 끼친다는 점을 확인해주었다. 이러한 결과는 다시마 분말이나 동 분말을 함유한 밥을 이용한 건강기능성 패티의 개발이 매우 긍정적이며 가능성이 높음을 알려준다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

백국과 황국 추출물의 항산화활성 및 항유전독성 효과 (Antioxidative and Antigenotoxic Activity of White and Yellow Chrysanthemum morifolium Ramat Extracts)

  • 이현정;김민정;박재희;박은주
    • 한국식품영양과학회지
    • /
    • 제41권3호
    • /
    • pp.289-294
    • /
    • 2012
  • 백국 및 황국의 물 및 용매 추출물의 항산화 효과를 측정하기 위해 총 페놀함량, DPPH radical 소거능과 SOD 유사활성을 측정하였다. 그 결과 총 페놀함량은 국화물추출물에서는 국화종류와 추출온도에 따른 차이가 없었으며, 용매추출물에서는 아세톤<에탄올<메탄올 추출물 순으로 유의적으로 높은 함량을 나타내었다. DPPH radical 소거능은 백국물추출물에서는 추출온도가 높을수록 증가하였으며, 황국물추출물에서는 $25^{\circ}C$에서 가장 높은 DPPH radical 소거능을 나타내었고, 모든 온도에서 황국물추출물이 백국물추출물보다 유의적으로 높은 DPPH radical 소거능을 나타내었다. 용매별 비교에서는 백국과 황국 모두 에탄올추출물에서 가장 높은 DPPH radical 소거능을 나타내었다. 또한 물추출물과 반대로 용매추출물에서는 백국이 황국보다 DPPH radical 소거능이 유의적으로 높은 것으로 나타났다. SOD 유사활성은 물추출물에서는 백국보다 황국에서 높은 활성을 나타내었으며, 용매추출물에서는 아세톤 및 에탄올추출물에서 백국보다 황국에서 유의적으로 높은 SOD 유사활성을 나타낸 반면, 메탄올추출물은 황국보다 백국에서 유의적으로 높은 SOD 유사활성을 나타내었다. 한편 국화용매추출물의 산화적 스트레스에 의한 DNA 손상 보호효과를 보기 위해 국화용매추출물을 50 ${\mu}g/mL$의 농도로 백혈구에 처리한 후 200 ${\mu}M$ $H_2O_2$로 DNA 손상을 유도한 결과, 백국과 황국 용매추출물 모두에서 에탄올추출물의 DNA 손상 억제율이 가장 높은 것으로 나타났다. 백국추출물과 마찬가지로 황국추출물에서도 DNA 손상 보호효과는 DPPH radical 소거능과 같은 경향을 나타내어, DPPH radical의 소거 활성을 증가시키는 물질이 산화적 스트레스에 대한 DNA 손상 보호 효과에도 기여하는 것으로 보인다. 이상의 결과에서 색에 따른 국화의 물 및 용매추출물의 항산화 활성 및 항유전독성을 확인하였으며, 이 결과들은 기능성 제품 개발을 위한 천연물 소재로서 국화의 활용성에 대한 기초자료로 제시될 수 있을 것이다.

오만둥이(Styela plicata)의 항유전독성 및 대장암 억제효과에 관한 연구 (Antigenotoxic and Anticarcinogenic Effects of Styela plicata)

  • 서보영;김정미;이승철;박은주
    • 한국식품영양과학회지
    • /
    • 제38권7호
    • /
    • pp.839-845
    • /
    • 2009
  • 오만둥이는 우리나라의 전통적인 수산식품으로써 찜 또는 찌개류로 조리하여 널리 이용하여 왔다. 본 연구에서는 오만둥이의 기능성 소재로서의 기능적 특성을 파악하기 위하여 오만둥이 추출물의 항산화 활성 및 항유전독성 활성을 in vitro 방법으로 측정하였다. 또한 대장암에 대한 예방효과를 알아보기 위하여 DMH로 대장암을 유발한 SD 쥐를 이용하여 오만둥이를 경구투여한 후 DNA 손상 및 ACF 형성에 미치는 영향을 알아보았다. 그 결과 총항산화능은 모든 추출물에서 대조구에 비해 유의적으로 높은 활성을 나타내었다. 동결건조 한 추출물에서는 메탄올, 에탄올(0.225, 0.219 mM) > 물(0.179 mM) > 아세톤(0.150 mM) 순으로 나타났으며, 신선한 오만둥이에서는 메탄올 추출물(0.215 mM)이 가장 높은 항산화력이 있는 것으로 나타났다. Comet assay에서는 모든 추출물이 $H_2O_2$에 의한 산화적 스트레스에 대항한 DNA 손상억제력을 향상시키는 것으로 나타났으며 특히 동결건조 한 오만둥이에서 메탄올 추출물의 억제력이 가장 높은 것으로 나타났다. 백혈구의 DNA 손상정도는 대조군에 비해 DMH 투여군에서 유의적으로 손상정도가 증가한 반면, DMH+S. placata군에서는 DMH를 주입한 군에 비하여 손상정도가 유의적으로 감소하였다. 또한 ACF의 생성수치가 DMH군에 비하여 DMH+S. placata군에서 유의적으로 감소하는 결과를 나타내었다. 이상의 결과로 미루어 볼 때 오만둥이는 in vitro 뿐만 아니라 대장암을 유발한 쥐에서도 항산화 및 항암효과에 긍정적인 영향을 미치는 것으로 나타나 오만둥이가 대장암을 예방하기 위한 기능성식품 소재로서 가능성을 보여 주었다.

냉동 정어리 조미육의 가공 및 저장중의 품질안정성 (Processing Conditions and Quality Stability of Frozen Seasoned Sardine Meat during Frozen Storage)

  • 이응호;오광수;안창범;이태훈;정영훈
    • 한국수산과학회지
    • /
    • 제20권3호
    • /
    • pp.191-201
    • /
    • 1987
  • 정어리를 효율적으로 이용하기 위하여 각종 조리재료 및 식품가공용 중간소재로 이용할 수 있는 정어리냉동조미육의 가공조건을 구명하고 저장 중의 품질안정성에 대하여 검토하였다. 정어리냉동조미육을 가공하기 위하여 정어리육을 채육한 다음 육에 대하여 대두유의 유화커어드 $20.6\%$, 식염 $0.5\%$, 설탕 $2.0\%$, sodium bicarbonate $0.4\%$, polyphosphosphate $0.2\%$, MSG $0.1\%$ 및 양파가루 $0.3\%$, 마늘가루 $0.1\%$, 생강가루 $0.1\%$, 대두단백질 $3.0\%$, 그리고 저장 중의 지질산화를 방지 할 목적으로 sodium erythortate를 $0.1\%$ 첨가하여 잘 혼합한 후 $-35^{\circ}C$에서 동결시켜 $-20^{\circ}C$에서 저장하는 것이 좋았다. 정어리냉동조미육의 수분함량은 $67\~70\%$, 조단백질 $14\~16\%$, 조지방 $11\~12\%$였으며, 저장 중 제품의 pH는 다소 감소하고 휘발성염기질소는 약간 증가하였으며 생균수는 거의 변화가 없었다. 동결저장 중 과산화물값, 카르보닐값 및 TBA값을 측정한 결과 sodium erythorbate를 첨가한 제품(B)는 지질산화가 효율적으로 억제되었다. 제품의 정미성분 중 IMP는 저장 중 감소하였오 hypoxanthine은 증가하였다. 제품의 유리아미노산은 histidine과 glutamic acid가 대부분을 차지하였고 저장 중 약간 증가하였다. 정어리냉동조미육의 정미성분의 주체는 양적으로 보아 유리아미노산과 핵산관련물질이었고 저장중 총량은 거의 변화가 없었다. 제품의 주요구성지방산은 18:2, 18:1, 16:0 및 18:3 등이있고 저장 중 22:6의 감소율은 제품(B)에서 현저하게 억제되었다. 저장 중 제품 모두 유리드립과 가압드립은 증가하였고 염용성질소는 감소하였다. 텍스튜어는 경도와 질김성이 다소 증가하였으며 탄성과 응집력은 거의 변화가 없었다. 색조는 L값(명도)은 감소하고 b값(황색도)은 약간 증가하였으며 그 변화폭은 표면이 더욱 컸다. 관능검사 결과 제품 모두 저장 120일 동안 품질이 안정하게 유지되었으며 제품(B)의 품질안정성이 가장 우수하였다.

  • PDF

Impact of Low Versus Conventional Doses of Chemotherapy During Transcatheter Arterial Chemo-embolization on Serum Fibrosis Indicators and Survival of Liver Cancer Patients

  • Kong, Wei-Dong;Cao, Jian-Ming;Xu, Jian;Chen, Bo;Yang, Tao;Xu, Tan-Tan;Lu, Guang-Ming;Li, Jun;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권9호
    • /
    • pp.4757-4761
    • /
    • 2012
  • Objectives: To explore the impact of low- vs conventional-dose chemotherapy via transcatheter arterial chemo-embolization (TACE) on serum fibrosis indicators and treatment efficacy of hepatocellular cancer patients (HCC). Materials and Methods: Patients fulfilling the eligibility criteria were assigned to TACE in Group A (with low-dose chemotherapy) or Group B (conventional-dose chemotherapy). Four serum fibrosis related indicators, hyaluronic acid(HA), human pro-collagen type-III (hPC-III), laminin (LN), and collagen type-IV(IV-C) before TACE were compared with the values 7 days after TACE. The response rate and survival time were also compared between the two groups. Results: Fifty patients with HCC were enrolled in this study, including 25 in Group A and 25 in Group B. No significant differences were detected between the two groups in the four indicators before TACE. After TACE, the value of the four serum indicators increased significantly in Group B. However, no significant differences regarding these four indicators were found in Group A after TACE. Significant differences were demonstrated between the two groups after TACE, but median survival time and 1 or 2 year overall survival rates did not differ (P>0.05). Conclusions: Low-, compared with conventional-dose chemotherapy exerts the same impact on the variation of fibrosis related indicators and has no influence on median survival time and survival rate after TACE in HCC patients.

블렌딩 에센션오일의 항균효과 증진 (Improved Antibacterial Effect of Blending Essential Oils)

  • 권필승;김대중;박호
    • 대한임상검사과학회지
    • /
    • 제49권3호
    • /
    • pp.256-262
    • /
    • 2017
  • 식물로부터 유래되는 휘발성 유기 화합물인 에센셜 오일은 인체에 약리효과를 나타낸다고 알려져 있다. 본 연구에서는 화농성 질환과 병독성 질환 비뇨기계통 감염에 나올 수 있는 병원성 세균 Staphylococcus aureus (그람양성알균), Escherichia coli (그람음성막대균), Pseudomonas aeruginosa (그람음성막대균, 극성단모균)을 대상으로 천연 허브 오일 중에 비교적 많이 알려져 있는 라벤더(lavender), 티트리(tea tree), 로즈마리(rosemary), 멜리사(melisa) 4종류의 단일 오일과 비교해, 티트리와 로즈마리, 멜리사를 블렌딩하였을 때 항균력이 상승되는 효과가 있는지 연구하였다. 그 결과 디스크 확산법에서 블렌딩 오일(티트리, 로즈마리, 멜리사)의 경우 단독의 허브오일보다 S. aureus에서18 mm, E. coli 에서 22 mm 와 P. aeruginosa는13 mm의 우수한 항균능력을 확인할 수 있었다. 뿐만 아니라 블렌딩 오일의 경우 최소억제농도(Minimum Inhibitory Concentrations, MIC) 분석에서 S. aureus, E. coli 에서는 0.3125%에서, P. aeruginosa는 1.25%에서 성장억제효과가 확인되었다. 따라서 본 실험에서는 블렌딩 오일이 Oxacillin과 로즈마리, 티트리보다 항균효과가 우수한 것으로 증명되어 단독의 허브오일보다 블렌딩 오일이 우수한 항균력을 나타나는 것을 확인할 수 있었다. 그러므로 허브의 블렌딩을 활용하면 다제 내성균에 대한 항균시너지효과를 발휘할 수 있음을 입증했을 뿐만 아니라 향후 천연보존제와 건강기능성 식품 및 화장품에 활용 가능성을 기대해본다.

인유두종 바이러스의 감염 또는 감염되지 않은 자궁 경부 이형성증에서 p53 및 Ki-67의 발현 (Expression of p53 and Ki-67 in Cervical Dysplasia with Human Papilloma Virus Infection or Non-infection)

  • 최숙경;김태전;홍승복;이훈택
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.178-184
    • /
    • 2004
  • This research focuses on the overall evaluation of tumor protein (p53) and cell growth marker (Ki-67) in their functions as carcinogenic factors in both a HPV-infected group and in a HPV-noninfected group with the precancerous dysplasia of uterine cervix. Histological grades were determined by the H&E staining and the expression level of p53 and Ki-67 were tested by the immunohistochemistry method. The results were as follows. Among the total of 66 cases, p53 (+) was observed in 19 cases (29.0%) from the mild grade group, 22 cases (33.0%) from the moderate grade group, and 19 cases (29.0%) from the severe grade group. The values correlate with the increase of dysplasia intensity in HPV-noninfected group and showed significant correlation (p<0.05), but there were no significant difference from the HPV-infected group. Among a total of 66 cases, the mitotic index of Ki-67 (+) were observed in 19 cases (29.0%) from the mild grade group, 22 cases (33.0%) from the moderate grade group, and 19 cases (29.0%) from the severe grade group. The values were significantly different against dysplasia intensity (p<0.05), but showed no significant difference from HPV infection. After cross comparing the statistical parameters of p53 and ki-67 in their significance, p53 was shown to be statistically significant with Ki-67 while there was no statistically significant difference with Ki-67 (p<0.05). Taken together, tumor protein (p53) and an index of Ki-67 observed in cervical dysplasia and in HPV related dysplasia of cervix uterine did not have any notable significance with HPV infection. The incidence rate of p53, however, had some significant correlation with dysplasia while Ki-67 had no particular statistical significance. As a result, p53 and Ki-67 can be considered as effective diagnostic markers in predicting the disease progression of dysplasia to cervical cancer.

  • PDF

인간 말초혈액 단핵구 유래 수지상세포의 면역반응에 미치는 Gefitinib의 영향 (The Effect of Gefitinib on Immune Response of Human Peripheral Blood Monocyte-Derived Dendritic Cells)

  • 조진훈;김미현;이광하;김기욱;전두수;박혜경;김윤성;이민기;박순규
    • Tuberculosis and Respiratory Diseases
    • /
    • 제69권6호
    • /
    • pp.456-464
    • /
    • 2010
  • Background: Synergistic antitumor effects of the combined chemoimmunotherapy based on dendritic cells have been reported recently. The aim of this study is to search new applicability of gefitinib into the combination treatment through the confirmation of gefitinib effects on the monocyte derived dendritic cells (moDCs); most potent antigen presenting cell (APC). Methods: Immature and mature monocyte-derived dendritic cell (im, mMoDC)s were generated from peripheral blood monocyte (PBMC) in Opti-MEM culture medium supplemented with IL-4, GM-CSF and cocktail, consisting of TNF-${\alpha}$ (10 ng/mL), IL-$1{\beta}$ (10 ng/mL), IL-6 (1,000 U/mL) and $PGE_2$ ($1{\mu}/mL$). Various concentrations of gefitinib also added on day 6 to see the influence on immature and mature MoDCs. Immunophenotyping of DCs under the gefitinib was performed by using monoclonal antibodies (CD14, CD80, CD83, CD86, HLA-ABC, HLA-DR). Supernatant IL-12 production and apoptosis of DCs was evaluated. And MLR assay with $[^3H]$-thymidine uptake assay was done. Results: Expression of CD83, MHC I were decreased in mMoDCs and MHC I was decreased in imMoDCs under gefitinib. IL-12 production from mMoDCs was decreased under $10{\mu}M$ of gefitinib sinificantly. Differences of T cell proliferation capacity were not observed in each concentration of geftinib. Conclusion: In spite of decreased expressions of some dendritic cell surface molecules and IL-12 production under $10{\mu}M$ of gefitinib, significant negative influences of gefitinib in antigen presenting capacity and T cell stimulation were not observed.