• Title/Summary/Keyword: human epididymis protein 4

Search Result 9, Processing Time 0.027 seconds

Tissue CA125 and HE4 Gene Expression Levels Offer Superior Accuracy in Discriminating Benign from Malignant Pelvic Masses

  • Fawzy, Amal;Mohamed, Mohamed R;Ali, Mohamed AM;El-Magied, Mohamed H Abd;Helal, Amany M
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.323-333
    • /
    • 2016
  • Background: Ovarian cancer remains a major worldwide health care issue due to the lack of satisfactory diagnostic methods for early detection of the disease. Prior studies on the role of serum cancer antigen 125 (CA125) and human epididymis protein 4 (HE4) in detecting ovarian cancer presented conflicting results. New tools to improve the accuracy of identifying malignancy are urgently needed. We here aimed to evaluate the diagnostic utility of tissue CA125 and HE4 gene expression in comparison to serum CA125 and HE4 in discriminating benign from malignant pelvic masses. Materials and Methods: One-hundred Egyptian women were enrolled in this study, including 60 epithelial ovarian cancer (EOC) patients and 20 benign ovarian tumor patients, as well as 20 apparently healthy women. Preoperative serum levels of CA125 and HE4 were measured by immunoassays. Tissue expression levels of genes encoding CA125 and HE4 were determined by quantitative real time polymerase chain reaction (qRT-PCR). The diagnostic performance of CA125 and HE4, measured either as mRNA or protein levels, was evaluated by receiver operating characteristic (ROC) curves. Results: The serum CA125+HE4 combination and serum HE4, with area under the curve (AUC) values of 0.935 and 0.932, respectively, performed significantly better than serum CA125 (AUC=0.592; P<0.001). Tissue CA125 and HE4 (AUC=1) performed significantly better than serum CA125 (P<0.001), serum HE4 (P=0.016) and the serum CA125+HE4 combination (P=0.018). Conclusions: Measurement of tissue CA125 and HE4 gene expression not only improves discriminatory performance, but also broadens the range of differential diagnostic possibilities in distinguishing EOC from benign ovarian tumors.

Does Human Epididymis Protein 4 (HE4) Have a Role in Prediction of Recurrent Epithelial Ovarian Cancer

  • Innao, Pedrada;Pothisuwan, Methasinee;Pengsa, Prasit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4483-4486
    • /
    • 2016
  • Background: Despite the fact that ovarian cancer is the seventh most common cancer in women worldwide and the fifth leading cause of cancer death, It is the most common cause of death due to reproductive cancers in Thailand where epithelial ovarian cancer (EOC) is commonly found. According to a Thai statistical analysis in 2010 by the Department of Medical Services, epithelial ovarian cancer was the sixth most common cancer in Thailand from 2001to 2003.The incidence of 5.1 per 100,000 women per year. Human epididymis protein 4 (HE4) is a novo diagnostic tumor marker for EOC. The combination of HE4 and carcinoma antigen 125 (CA 125) is a tool for detecting epithelial ovarian cancer (EOC) better than using CA 125 alone. Therefore, the researcher is interested in HE4 does have a role to predict recurrent epithelial ovarian cancer. Materials and Methods: The patients who had complete response after diagnosed with epithelial ovarian cancer by pathology, FIGO stage 3 or more had been treated through surgery and chemotherapy at the Sunpasitthiprasong Hospital from June 2014 until March 2016. The patients were followed up every three months, using tumor marker (CA 125, HE4,Carcinoma antigen 19-9) together with other checkup methods, such as rectovaginal examination, CXR every year and other imaging as indication. Afterwards, the data was analyzed for the ability of HE4 to detect recurrence of epithelial ovarian cancer. Results: In 47 patients in this study follow-up for 22 months after complete response treatment from surgery and chemotherapy in epithelial ovarian cancer, 23 had recurrent disease and HE4 titer rising. The patients with recurrent epithelial ovarian cancer demonstrated high levels of both HE4 and CA125 with sensitivity of 91.3% and 52.7% respectively, specificity of 87.5% and 95.6% and positive predictive values of 87.5% and 85.7%. HE4 can predict recurrent epithelial ovarian cancer (p-value=0.02242). Comparing HE4 and CA125 in predicting recurrent epithelial ovarian cancer HE4 had more potential than CA125 (p-value =0.8314). Conclusions: The present study showed HE4 to have a role in predicting recurrent epithelial ovarian cancer and HE4 is potentially better than CA125 as a marker for this purpose.

Association of Serum HE4 with Primary Tumor Diameter and Depth of Myometrial Invasion in Endometrial Cancer Patients at Rajavithi Hospital

  • Prueksaritanond, Nisa;Cheanpracha, Patchara;Yanaranop, Marut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1489-1492
    • /
    • 2016
  • Background: Although there are no biomarkers that are routinely used in endometrial cancer (EC) management, many studies have found that serum human epididymis protein 4 (HE4) is superior to cancer antigen 125 (CA125) in the detection of EC. The correlation of HE4 with two prognostic factors for EC, primary tumor diameter (PTD) and depth of myometrial invasion (DMI) may be useful in identifying EC patients at high risk of lymphatic dissemination. Objective: To evaluate the correlation of serum HE4 with PTD and DMI in patients with EC. Materials and Methods: A cross-sectional study was conducted on 70 EC patients who were scheduled for elective surgery at Rajavithi Hospital between 1st September 2013 and 30th May 2014. Preoperative serum levels of HE4 and CA125 were investigated, and then gross measurement of PTD was taken and postoperative pathologic slides were reviewed for DMI including histologic types, grading and staging. Results: Preoperative serum HE4 levels were strongly correlated with PTD (r=0.65, p<0.001) and moderately correlated with DMI (r=0.46, p<0.001). Moreover, serum HE4 levels were significantly elevated in EC patients with PTD >2 cm (p<0.001) and DMI > 50% (p=0.004). The performance of serum HE4 in identifying EC patients at low risk and high risk of lymph node metastasis was significantly better than that of CA125 (AUC 0.88 vs. 0.65, p=0.003). At an optimal cut-off value of 70 pM/L, serum HE4 had a sensitivity of 83.3% and a specificity of 80.0%. Conclusions: In EC patients, preoperative serum HE4 is significantly correlated with PTD and DMI. Serum HE4 levels could be useful in identifying endometrial cancer patients at high risk of lymphatic spread who would benefit from systemic lymphadenectomy at the cut-off value of 70 pM/L.

HE4 as a Serum Biomarker for ROMA Prediction and Prognosis of Epithelial Ovarian Cancer

  • Chen, Wen-Ting;Gao, Xiang;Han, Xiao-Dian;Zheng, Hui;Guo, Lin;Lu, Ren-Quan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.1
    • /
    • pp.101-105
    • /
    • 2014
  • Background and Purpose: Human epididymis protein 4 (HE4) has been suggested to be a novel biomarker of epithelial ovarian cancer (EOC). The present study aimed to evaluate and compare HE4 with the commonly used marker, carbohydrate antigen 125 (CA125), in prediction and therapy-monitoring of EOC. Patients and Methods: Serum HE4 concentrations from 123 ovarian cancer patients and 174 controls were measured by Roche electrochemiluminescent immunoassay (ECLIA). Risk of ovarian malignancy algorithm (ROMA) values were calculated and assessed. In addition, the prospects of HE4 detection for therapy-monitoring were evaluated in EOC patients. Results: The ROMA score could classify patients into high- and low-risk groups with malignancy. Indeed, lower serum HE4 was significantly associated with successful surgical therapy. Specifically, 38 patients with EOC exhibited a greater decline of HE4 compared with CA125. In contrast, elevation of HE4 better predicted recurrence (of 46, 11 patients developed recurrence, and with it increased HE4 serum concentrations) and a poor prognosis than CA125. Conclusions: This study suggests that serum HE4 levels are closely associated with outcome of surgical therapy and disease prognosis in Chinese EOC patients.

Expression of Heat Shock Protein HspA2 in Human Tissues (인간 조직에서 Heat Shock Protein A2 (HspA2) 단백질의 발현)

  • Son, W.Y.;Hwang, S.H.;Han, C.T.;Lee, J.H.;Choi, Y.J.;Kim, S.;Kim, Y.C.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.2
    • /
    • pp.225-230
    • /
    • 1999
  • In mouse, the heat shock protein 70-2 (hsp70-2) is found to have special function in spermatogenesis. Based on the observation, the hypothesis that human hspA2 (human gene; 98.2% amino acid homology with hsp70-2) might have important function in spermatogenesis in human testes was proposed. To test the hypothesis, we examined the expression of hspA2 in human tissues. Expression vector pDMC4 for expression of the human hspA2 protein using pTricHisB (invitrogen, USA) was constructed and the expressed hspA2 protein was cross-reacted with antiserum 2A raised against mouse hsp70-2 protein. Based on the cross-reactivity, we determined the expression level of hspA2 protein in human tissues by western blot analysis using the antiserum 2A. We demonstrated that antiserum 2A antibodies detected human hspA2 protein with specificity which was produced in the E.coli expression system. On Western blot analyses, significant hspA2 expression was observed in testes with normal spermatogenesis, whereas a low level of hspA2 was expressed in testis with Sertoli-cell only syndrome. Also, a small amount of hspA2 was detected in breast, stomach, prostate, colon, liver, ovary, and epididymis. These results demonstrate that the hspA2 protein is highly expressed in male specific germ cells, which in turn suggests that hspA2 protein might playa specific role during meiosis in human testes as suggested in the murine model. However, further studies should be attempted to determine the function of hspA2 protein in human spermatogenesis.

  • PDF

Diagnostic Value of Human Epididymis Protein 4 Compared with Mesothelin for Ovarian Cancer: a Systematic Review and Meta-analysis

  • Lin, Jia-Ying;Qin, Jin-Bao;Li, Xiao-Yan;Dong, Ping;Yin, Bing-De
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.11
    • /
    • pp.5427-5432
    • /
    • 2012
  • Background and Purpose: Ovarian cancer is the leading cause of death among gynecologic cancers because of the lack of effective early detection methods. Accuracies of the human epididymis protein 4 (HE4) and mesothelin in detecting ovarian cancer have never been systematically assessed. The current systematic review aimed to tackle this issue. Methods: MEDLINE, EMBASE, and Cochrane databases were searched (September 1995-November 2011) for studies on the diagnostic performances of HE4 and mesothelin in differentiating ovarian cancer from other benign gynecologic diseases. QUADAS items were used to evaluate the qualities of the studies. Meta-DiSc software was used to handle data from the included studies and to examine heterogeneity. All included studies for diagnostic performance were combined with sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratios (DORs) with 95% confidence intervals (CIs), summary receiver operating characteristic (SROC) curves, and areas under the SROC curves (AUC). Results: A total of 18 studies and 3,865 patients were eligible for the final analysis. The pooled sensitivity estimates for HE4 (74.4%) were significantly higher than those for mesothelin (49.3%). The pooled specificity estimates for mesothelin (94.5%) were higher than those for HE4 (85.8%). The pooled DOR estimates for HE4 (26.22) were higher than those for mesothelin (24.01). The SROC curve for HE4 showed better diagnostic accuracy than that for mesothelin. The PLR and NLR of HE4 were 6.33 (95% CI: 3.58 to 11.18) and 0.27 (95% CI: 0.21 to 0.34), respectively. The PLR and NLR for mesothelin were 11.0 (95% CI: 6.21 to 19.59) and 0.51 (95% CI: 0.42 to 0.62), respectively. The combination of the two tumor markers or their combination with CA-125 increased sensitivity and specificity to different extents. Conclusion: The diagnostic accuracy of HE4 in differentiating ovarian cancer from other benign gynecologic diseases is better than that of soluble mesothelin-related protein. Combinations of two or more tumor markers show more sensitivity and specificity.

Comparison of Diagnostic Accuracies of Serum HE-4 Levels and 3D Power Doppler Angiography Parameters between Benign Endometrial Pathologies and Endometrial Cancer

  • Erenel, Hakan;Bese, Tugan;Sal, Veysel;Demirkiran, Fuat;Arvas, Macit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2507-2511
    • /
    • 2016
  • Purpose: To study the diagnostic accuracies of serum human epididymis protein 4 (HE-4) levels, virtual organ computer-aided analysis (VOCAL) parameters and endometrial volume in endometrial cancer cases. Materials and Methods: One hundred and seven patients (37 with endometrial cancer and 70 with benign endometrial pathology) were included in this study. VOCAL parameters and serum HE-4 levels were compared between the groups. Results: Area under the curve (AUC) values were 0.702, 0.658, 0.706 for vascularization index (VI), the flow index (FI) and the vascularization flow index (VFI), respectively. A cut off value of 0.568 for VI demonstrated 70% sensitivity, 72% specificity, 56% positive predictive value (PPV) and a81% negative predictive value (NPV). A cut off value of 25.8 for showed a senitivith of 70% and a specificity of 58% with aPPV of 46% and NPV of 78%, and with a cut off value of 0.12 for VFI 70%, 69%, 54% and 81%, respectively. The area under the curve for HE-4 was 0.814. A cut off value of 458 pmol/L was predictive of malignancy with 86% sensitivity and 63% specificity. Conclusions: VOCAL parameters and serum HE-4 levels were statistically significantly higher in the endometrial cancer patients. Serum HE-4 levels provided a greater sensitivity compared to power doppler angiography for predicting malignancy or benign endometrial pathology.

Studies on Protein Contents and Enzyme Activities of Human Seminal Plasma (사람정장(精漿)의 단백질농도(蛋白質濃度)와 효소활성도(酵素活性度)에 관한 연구(硏究))

  • Park, Kyu-Hong;Lee, Hee-Yong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.10 no.1
    • /
    • pp.7-24
    • /
    • 1983
  • On the basis of the semen analysis in 66 subjects, they were divided into six different groups: Group I consisted of 16 normal subjects with sperm counts of over 40 ${\times}10^6$/ml and motility of over 40 percent, Group II, 7 subjects with normal sperm counts, but motility of under 40 percent, Group III, 15 oligospermic patients with under 40 ${\times}10^6$/ml, Group IV 14 azoospermic patients, Group V, 10 patients with vasectomy and Group VI, 4 abnormal patients with 2 cases of hypoplastic testis, 1 case of Klinefelter's syndrome and 1 case of testis tumor. After seperation of semen into sperm and seminal plasma by centrifugation, the protein contents and the activities of hyaluronidase, ${\beta}$-N acetylglucosaminidase, ${\beta}$-glucuronidase, arylsulfatase, acrosin and azocoll proteinase in seminal plasma were measured. Vasectomy group has 30 percent less of total protein than normal group. For the comparison of enzyme activities of seminal plasma, it could be assumed that the enzymes in seminal plasma were not contaminated with the enzymes of spermatozoa by testing the enzymes of the seminal plasma from the vasectomy and azoospermic groups. It had been reported that hyaluronidase was only released from spermatozoa, however, the result obtained in this investigation showed that azoospermic and vasectomy group had high specific activities of hyaluronidase. The results indicated that hyaluronidase was not only from the testis but also from the male accessory sexual glands. Oligospermic group (Group III) showed the lowest total activity of hyaluronidase among them. The specific activities of ${\beta}$ -N-acetylglucosaminidase was high in oligospermic group (Group III) and low in vasectomy group (Group V). These results were contradictory with the pattern of hyaluronidase activities. This indicated that the spermatozoa which were stayed in epididymis would increase the activity of this enzyme. The specific activity of ${\beta}$ - glucuronidase was low in oligospermic and vasectomy groups. Group VI including testis tumor had remarkably high arylsulfatase activity. Arylsulfatase, a typical lysosomal enzyme, has been known to be released unusually large amounts from certain tumor cells. Arylsulfatase was also released with high activities from azoospermic and vascetomy group. This result indicated that this enzyme was also released from the sources other than testis. Acrosin, a proteolytic enzyme locating in the sperm acrosome, was not found throughout all the samples of seminal plasma. The activities of azocoll proteinase, a non-specific neutral proteinase was nearly identical in all the groups. This enzyme must have been released from the sources other than testis.

  • PDF

Human Epididymis Protein 4 Reference Intervals in a Multiethnic Asian Women Population

  • Mokhtar, N.M.;Thevarajah, M.;M.A., Noorazmi;M., Isahak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6391-6395
    • /
    • 2012
  • Background: Ovarian cancer is ranked as the fifth most common cause of cancer death in women. In Malaysia, it is the fourth most common cancer in females. CA125 has been the tumor marker of choice in ovarian cancer but its diagnostic specificity in early stages is only 50%. Hence, there is a critical need to identify an alternative tumor marker that is capable of detecting detect ovarian cancer at an early stage. HE4 is a new tumor marker proposed for the early diagnosis of ovarian cancer and disease recurrence. Currently, none of the normal ranges of HE4 quoted in the literature are based on data for a multiethnic Asian population. Therefore, the aim of this study was to determine reference intervals for HE4 in an Asian population presenting in University Malaya Medical Centre, a tertiary reference hospital. Materials and Methods: 300 healthy women were recruited comprising 150 premenopausal and 150 postmenopausal women, aged from 20-76 years. All women were subjected to a pelvic ultrasonograph and were confirmed to be free from ovarian pathology on recruitment. Serum HE4 levels were determined by chemiluminescent microparticle immunoassay (CMIA, Abbott Architect). The reference intervals were determined following CLSI guidelines (C28-A2) using a non-parametric method. Results: The upper limits of the $95^{th}$ percentile reference interval (90%CI) for all the women collectively were 64.6 pmol/L, and 58.4 pmol/L for premenopausal) and 69.0 pmol/L for postmenopausal. The concentration of HE4 was noted to increase with age especially in women who were more than 50 years old. We also noted that our proposed reference limit was lower compared to the level given by manufacturer Abbott Architect HE4 kit insert (58.4 vs 70 pmol/L for premenopausal group and 69.0 vs 140 pmol/L in the postmenopausal group). The study also showed a significant difference in HE4 concentrations between ethnic groups (Malays and Indians). The levels of HE4 in Indians appeared higher than in Malays (p<0.05), while no significant differences were noted between the Malays and Chinese ethnic groups. Conclusions: More data are needed to establish a reference interval that will better represent the multiethnic Malaysian population. Probably a larger sampling size of equal representation of the Malay, Chinese, Indians as well as the other native ethnic communities will give us a greater confidence on whether genetics plays a role in reference interval determination.