• Title/Summary/Keyword: housing with window and without window

Search Result 7, Processing Time 0.022 seconds

Prediction of Reduction Rates of Daylight Illuminance for Blind Conditions in a Small Office (소규모 사무실의 블라인드 조건에 따른 주광조도 감소비율 예측)

  • Gu, Renyan
    • Land and Housing Review
    • /
    • v.12 no.2
    • /
    • pp.79-89
    • /
    • 2021
  • This simulation based study analyzed the horizontal daylight distribution on the floor and ceiling of a small office space based on window orientations and interior window blind positions. South and north facing windows were each tested without window blinds and with window blinds at 45° and 180° (horizontal). The study showed that the illuminance value was highest 1m from the window. On the floor and ceiling, the difference in illuminance value was the greatest and least in December and June, respectively. The indoor illuminance value was highest when there was no window blind and under south-facing conditions. The greatest illuminance difference occurred between window blinds positioned at 45° and 180°. Under north-facing conditions, windows without blinds or with blinds at 45° had the least impact on indoor illuminance with illuminance being more evenly distributed.

Effect of Stocking Density on Chicken Meat Grades and PSE Incidence in Broiler House with or without Window (유창 및 무창계사의 사육 밀도에 따른 닭고기 등급 및 PSE육 출현에 미치는 영향)

  • Chae, H.S.;Kang, H.S.;Yoo, Y.M.;Jang, A.;Jeong, S.G.;Ham, J.S.;Ahn, C.N.
    • Korean Journal of Poultry Science
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • This study was performed to evaluate the effect of the level of stocking density of housing with or without window on chicken meat quality. The incidence of $1^+$ grade of whole chicken housed with window significantly influenced by stocking density. The incidence of $1^+$ grade chicken at high stocking density ($0.050\;m^2$/head), standard stocking density ($0.066\;m^2$/head), and low stocking density ($0.083\;m^2$/head) was 26, 52, and 66%, respectively. Breast muscle of chicken housed with window and with low stocking density showed higher incidence of $1^+$ grade than high stocking density. Also minor and severe PSE (pale, soft, extractive) incidence of chicken meat were showed 4% each, while the $1^+$ grade chicken was not appeared at low density. In chicken thigh, the incidence rate was not affected by stocking density. In chicken housed without window, the incidence of $1^+$ grade chicken in high, standard, and low stocking density was 18, 8, and 46%, respectively. Also, the incidence of $1^+$ grade chicken breast was 2.6 times higher than the chicken in low stocking density. However, incidence of $1^+$ grade thigh was not affected by the stocking density. These results suggest that high stocking density significantly reduced the incidence of $1^+$ grade chicken meat regardless of housing with or without window.

A Study on the amount of Co gas in the kitchen related to facility enviromental condition and fuel management (부엌공기 중에 함유되어 있는 가스량과 부엌 구조시설 연료관리와의 관계에 대한 연구)

  • 장명욱
    • Journal of the Korean Home Economics Association
    • /
    • v.8 no.1
    • /
    • pp.146-158
    • /
    • 1970
  • It is a matter of amazing to realize that contamination of air by fuel gas in recent daily life at home directly effects to health of Korean housewives. A study in finding the status and the amount of co gas in the kitchen was con-ductedrelating the size of kitchen, door of exit, ventilation window, constraction of built in-brick stove (Boo Tu Mack), fuel management, in order to extend beneficial and improved management of housing. From the result of study, it was pointed out that constractional improvement of built-in-brick stove, heating floor (Ondol), timny, and ventilation window would been emergently needed. Demonstration studies were obtained in finding differences of the amount of co gas respectively in cooking time as 50-55ppm, and in not cooking time as 50-80p,p,m in the kitchen both, original and improved. Definite differences were found depend upon the condition with, without, or direction of the ventilation window. In addition to all above results, significant influence on gas pulling power of Ondol tunnel was shown. Many houses of Apartment house for have middle and low income groups been recognized so poor for health as indicated over 100ppm of co gas if window were not opened because of poor ventilation and weak gas pulling power of Ondol tunnel.

  • PDF

Airborne Sound Insulation Performance of Window and Indoor Noise Level in the Balcony Expanded Apartments

  • Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.61-67
    • /
    • 2015
  • Purpose: The balcony in the apartment is important space not only as a fire escape but also as a buffer for heat and sound insulation. However, with the legalization of balcony expansion for residential apartments in Korea in 2006, many households have eliminated the balcony space altogether to increase the inner space, often without sufficient consideration for the effects on the indoor environment. This study examined the sound insulation performance of exterior-facing windows in enclosed balconies and the changes in the indoor acoustic environment due to expansion to provide a basis for appropriate balcony expansion. The apartments for the field test were chosen where two balcony types can be compared, and the sound insulation performance for the eighteen balcony windows was measured. The windows installed were typical double window with thickness 16 mm or 22 mm. Measurements of the weighted standard sound pressure level difference showed a decrease of about 3 dB in sound insulation performance due to expansion. For common exterior noise levels of 70-85 dB(A), the indoor noise level can exceed 45 dB(A), the limit level regulated in Korea. However, it was found that the sound insulation performance of the window and the quality of the construction have more influence on indoor noise levels than balcony expansion itself.

An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter (차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구)

  • Kim, Jin-Hee;Kim, Young-Tag;Lee, Soo-Yeol;Choi, Won-Ki
    • Land and Housing Review
    • /
    • v.12 no.1
    • /
    • pp.129-137
    • /
    • 2021
  • External shading devices are well known solar control devices that can help reduce the cooling load of commercial buildings. For this study, experiments were conducted to examine the feasibility of shading devices in reducing both the cooling and heating loads. The influence of sky radiant cooling during winter was verified for the external shading device, internal roller blind, and window. Results can be summarized as follows. The temperature difference between the inner and outer surfaces of the window with the external shading device was 11.8℃ compared to 14.6℃ for one without the external shading device. This 2.8℃ difference was due to heat exchange by sky radiation when the surface temperature of the shading device was lower than the ambient outdoor air temperature. The roller blind resulted in a lower temperature of 0.8℃ compared to the average temperature of the window's air cavity. This was due to heat exchange by sky radiation of the roller blind surfaces. Without shading devices, the outside surface temperature of the window is about 3℃ higher. The study also found that when external shading devices were installed on both the southwest and southeast sides, the outside surface temperature of the windows were lower on the southwest side than the southeast side.

Design of a low frequency, high power acoustic transducer to use in the echo sounder (어군탐지기용 저주파.고출력 음향 변환기의 설계)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • A low frequency, high power hydroacoustic transducer with 7 tonpilz piston elements assembled in a circular array suitable for marine application, such as the transmission of underwater information and the development of new fisheries resources in the deep sea zone was designed. A modified Mason's model was applied to monitor and to simulate the transducer behavior at each step during the fabrication. The in air, and in water constructed tonpilz transducer was tested experimentally and numerically by changing the size and the type of the material for head, tail and acoustic window. Also, the developed transducer was excited by pulse signals and the received waveform was analyzed. The resonance peaks in the transmitting voltage response(TVR) of a single tonpilz element without housing were observed at 11.33kHz in air and 10.93kHz in air and 10.93 kHz in water, respectively, with the overall electrical-acoustic efficiency of 43.7%. The value of TVR of single tonpilz element with aluminum housing in water was 129.87dB re 1 $\mu$Pa/V at 12.25 kHz with the frequency bandwith of 2.15 kHz and half beam angle of 30.2$^{\circ}$at -3dB.The resonance peaks in the transmitting voltage response of the 7 element circular transducer were observed at 11.50 kHz in air and 11.45 kHz in water, respectively. The value of TVR in water 144.84 dB re 1$\mu$Pa/V at 11.5kHz with the frequency bandwith of 4.25 kHz and the half beam angle of $22.3^{\circ} $ at -3dB.Reasonable agreement between the experimental measurements and the theoretical predictions for the directivity patterns, TVRs and the impedance characteristics of the designed transducer was achieved.

  • PDF

The Effects of Eco-Friendly Consumer Education on Ecological Footprint (환경 친화적 소비자 교육이 생태 발자국에 미치는 영향)

  • Yoon, Yeo-Chan;Choi, Don-Hyung
    • Hwankyungkyoyuk
    • /
    • v.20 no.2
    • /
    • pp.67-77
    • /
    • 2007
  • The purpose of this study is to investigate the change in ecological footprint made by the eco-friendly consumer education program, and ultimately, to help the high school students, future consumers, have eco-friendly attitude. This study will be contributed to helping them to understand the importance of the eco-friendly consumption and the seriousness of the environmental problems arising from their bad consumption habit, to get interested in the environmental problems in daily lives, and to reduce the ecological footprint through the eco-friendly habit acquired when young. This study is designed to have 60 high school students experience the eco-friendly consumer education program for 10 months and compare the levels of each ecological footprint though two different Questionnaires in five sections: housing, food, transportation, purchase, and waste. The program used in this research consists of three parts: eco-friendly attitude education for consumers, eco-friendly citizen education for consumers, and eco-friendly resource management education for consumers. The data are analyzed by SPSS Window 10.0 program. The findings are as follows: First. The eco-friendly consumer education is more likely to help the students develop critical thought and eco-friendly attitude, unlike the economy-related consumer education. Second. The level of ecological footprint is significantly decreased in the group with the eco-friendly consumer education program. compared to the group without it. Third. Experiencing the eco-friendly consumer education program helps the students have the positive attitude on ecology and lead an environmentally sustainable consumer life. The results show that eco-friendly consumer education can make a contribution to raising the good citizens who have eco-friendly attitude and behavior, lead sustainable consumer life, and try to reduce the level of ecological footprint.

  • PDF